期刊文献+
共找到147篇文章
< 1 2 8 >
每页显示 20 50 100
OPD-ScanⅢ及IOL-Master 700测量白内障术前角膜曲率和水平角膜直径的比较
1
作者 郭晓娜 陆惠 +2 位作者 寇豆 于璐 凌宇 《眼科新进展》 CAS 北大核心 2024年第5期391-395,共5页
目的比较OPD-ScanⅢ与IOL-Master 700在角膜曲率(平坦曲率K1与陡峭曲率K2)及水平角膜直径(WTW)测量上的差异性及一致性。方法选取2021年10月至2022年9月在航天中心医院眼科行白内障手术的患者268例328眼(右眼164例,左眼164例)。采用OPD-... 目的比较OPD-ScanⅢ与IOL-Master 700在角膜曲率(平坦曲率K1与陡峭曲率K2)及水平角膜直径(WTW)测量上的差异性及一致性。方法选取2021年10月至2022年9月在航天中心医院眼科行白内障手术的患者268例328眼(右眼164例,左眼164例)。采用OPD-ScanⅢ及IOL-Master 700仪器分别检测患者左右眼的K1、K2以及WTW值并进行分析比较。采用配对t检验进行参数比较;Pearson相关分析检测参数间的相关性;Bland-Altman以及组内相关系数(ICC)分析确定两种仪器相关参数测量的一致性。结果在左右眼参数的测量中,OPD-ScanⅢ测得的K1及K2值均大于IOL-Master 700,WTW值均低于IOL-Master 700的测量值,差异均有统计学意义(均为P<0.001)。OPD-ScanⅢ在左右眼中测得的K1、K2及WTW值与IOL-Master 700所测得的对应值均呈正相关,差异均有统计学意义(均为P<0.001)。两种仪器K1、K2及WTW值在95%一致性界限外的比例均在5%以内,但95%界限内差值绝对值均接近或超过了1.0 D,存在较大的临床偏差。ICC分析证实两种仪器左右眼测量K1及K2值一致性均极好(ICC>0.90)。两种仪器测得的WTW差值与K2值均显著相关(均为P<0.05)。WTW正偏差范围外有5例(83.33%)样本IOL-Master 700测得的K 2在47.03以上。结论OPD-ScanⅢ及IOL-Master 700在测量K1、K2及WTW上存在偏差,临床应用中不可互相替代。IOL-Master 700测得的WTW值大于OPD-ScanⅢ,当其测量的K2≥47.03时,所获得的WTW值参考价值可能有限。 展开更多
关键词 OPD-ScanⅢ iol-master 700 角膜曲率 角膜水平直径
下载PDF
IOL-Master在不同公式下对轴性高度近视眼术后屈光准确度评估 被引量:7
2
作者 臧晶 陈立伦 +6 位作者 鲍炯琳 王文娟 周斌兵 朱宇东 李青 林文雄 孙丽 《眼科新进展》 CAS 北大核心 2016年第6期554-558,共5页
目的应用IOL-Master通过不同人工晶状体计算公式,分析轴性高度近视眼患者行白内障手术后目标屈光和实际屈光的符合程度,评价不同人工晶状体计算公式的准确度。方法收集2013年1月至2014年4月在我院行白内障手术的轴性高度近视患者66例(... 目的应用IOL-Master通过不同人工晶状体计算公式,分析轴性高度近视眼患者行白内障手术后目标屈光和实际屈光的符合程度,评价不同人工晶状体计算公式的准确度。方法收集2013年1月至2014年4月在我院行白内障手术的轴性高度近视患者66例(100眼),将其按眼轴长度(axial length,AL)分为三组,组1为26 mm≤AL〈28 mm(54眼),组2为28≤AL〈30 mm(28眼),组3为AL≥30 mm(18眼);按角膜曲率(K)分为四组,组1为≤42.00 D(17眼),组2为〉42.00~44.00 D(27眼),组3为〉44.00~46.00 D(48眼),组4为〉46.00 D(8眼)。术前均采用Haigis、SRK/T、Holladay I及Hoffer Q公式进行人工晶状体度数计算。应用IOL-Master的部分相干干涉测量(partial coherence interferometry,PCI)技术计算人工晶状体度数。分析Haigis、SRK/T、Holladay I及Hoffer Q四种计算公式所预估的术后目标屈光度与术后6个月的实际屈光度符合程度。结果按AL分组,组1中,四种公式对术后实际屈光的预测准确度一样,四种方法之间比较,差异无统计学意义(P〉0.05);组2中,SRK/T公式的目标屈光与实际屈光的差值最小,准确度最高,四种方法之间比较,差异有统计学意义(P〈0.05);组3中,Haigis公式的目标屈光与实际屈光的差值最小,准确度最高,四种方法之间比较,差异有统计学意义(P〈0.05)。按角膜曲率分组,各组中四种方法之间比较,差异无统计学意义(P〉0.05)。结论利用IOL-Master对长眼轴进行人工晶状体度数计算时,Haigis公式具有相对稳定的准确度,而随着患者眼轴的增加,准确度逐渐下降。 展开更多
关键词 轴性高度近视 人工晶状体计算公式 iol-master Haigis公式 SRK/T公式
下载PDF
IOL-Master测量硅油眼轴长精确性的研究 被引量:11
3
作者 谢安明 张坚 《国际眼科杂志》 CAS 2008年第9期1842-1843,共2页
目的:比较IOL-Master与A超测量硅油填充眼轴长的准确性,探讨两种临床应用特点。方法:分析14例玻璃切割术后硅油填充眼分别采取A超和IOL-Master测量眼轴长度。结果:A超测得硅油眼轴长分别为仰卧位22.48±5.19mm,坐位25.10±4.19m... 目的:比较IOL-Master与A超测量硅油填充眼轴长的准确性,探讨两种临床应用特点。方法:分析14例玻璃切割术后硅油填充眼分别采取A超和IOL-Master测量眼轴长度。结果:A超测得硅油眼轴长分别为仰卧位22.48±5.19mm,坐位25.10±4.19mm;IOL-Master测得硅油眼轴长为26.32±4.16mm。不同体位A超测量硅油眼轴长度有显著差异(t=-6.27,P<0.01),用IOL-Master和A超两种方法测量硅油眼眼轴长度有显著统计学差异(t=-6.08,P<0.01)。结论:A超和IOL-Master用于正常眼轴长的测量都具有精确性高的特点,IOL-Master采用非接触方法更为简便;对硅油填充眼测量时A超受体位及屈光介质声学性质影响而差异显著,而IOL-Master可克服声学测量缺陷,对于硅油填充眼轴长测量更为准确。因此临床上应根据个体情况选择不同的测量方法以准确测量眼轴长度。 展开更多
关键词 iol-master 硅油眼 眼轴长
下载PDF
光学生物测量仪SW-9000与IOL-Master测量青少年眼球生物学参数的对比 被引量:3
4
作者 杨晓艳 李丽华 +2 位作者 陈晓琴 刘春燕 陈松 《眼科新进展》 CAS 北大核心 2019年第4期346-349,共4页
目的比较SW-9000和IOL-Master测量青少年眼轴长度(axial length,AL)、角膜曲率及角膜直径的准确性和一致性。方法选取来我院进行验光配镜的青少年患者101例,分别在自然瞳孔下进行SW-9000和IOL-Master测量,主要分析AL、角膜平坦曲率(flat... 目的比较SW-9000和IOL-Master测量青少年眼轴长度(axial length,AL)、角膜曲率及角膜直径的准确性和一致性。方法选取来我院进行验光配镜的青少年患者101例,分别在自然瞳孔下进行SW-9000和IOL-Master测量,主要分析AL、角膜平坦曲率(flattest keratometry,FK)、角膜陡峭曲率(steepest keratometry,SK)、角膜水平直径(白到白距离;white to white,WTW)等生物学参数指标在两种测量方法之间的一致性和相关性。应用组内相关系数(intraclass correlation coefficient,ICC)和Bland-Altman一致性分析来评估两种检查设备的可靠性和一致性。结果两种测量方法测得的AL、FK、SK、WTW平均差值分别为0.09 mm、-0.08 D、-0.22 D、0.12 mm。两种测量方法测量的95%一致性界限范围,AL为0.56 mm,FK为1.38 D,SK为1.81 D,WTW为3.28 mm;其中WTW的范围最宽。2种仪器所测结果进行ICC分析,结果显示,AL、FK、SK、WTW的相关系数分别为0.997、0.987、0.983和0.179。结论 SW-9000测量AL、角膜曲率与IOL-Master的测量结果具有较高的一致性,SW-9000测量AL略长于IOL-Master,角膜曲率略平坦于IOL-Master;角膜直径的测量两者一致性较差。 展开更多
关键词 眼生物学参数 SW-9000 iol-master 青少年
下载PDF
IOL-Master与A型超声测量前房深度和眼轴长度比较及其相关性 被引量:5
5
作者 徐海燕 金玉梅 +2 位作者 李辉 胡伯越 姜茹欣 《协和医学杂志》 2012年第2期200-203,共4页
目的了解IOL-Master生物测量仪的准确性及可靠性。方法对北京协和医院92例患者161眼分别用IOL-Master和A型超声测量前房深度及眼轴长度,同时用IOL-Master及电脑验光仪测量角膜曲率。结果 IOL-Master和A型超声对前房深度的测量值分别为(2... 目的了解IOL-Master生物测量仪的准确性及可靠性。方法对北京协和医院92例患者161眼分别用IOL-Master和A型超声测量前房深度及眼轴长度,同时用IOL-Master及电脑验光仪测量角膜曲率。结果 IOL-Master和A型超声对前房深度的测量值分别为(2.94±0.19)和(2.77±0.13)mm,两种方法比较差异有统计学意义(P<0.001),但两种测量方法无显著相关性(r=0.012,P>0.05)。IOL-Master和A型超声对眼轴长度的测量值分别为(24.10±2.36)和(23.91±2.13)mm,两种方法比较差异有统计学意义(P<0.01),且两种测量方法具有显著相关性(r=0.983,P<0.001)。IOL-Master和电脑验光仪测量角膜曲率分别为(44.38±1.66)和(44.12±1.62)D,两种方法比较差异有统计学意义(P<0.001)。结论 IOL-Master与A型超声均可用于眼前节相关参数测量,基于光学原理基础,IOL-Master测量前房深度和眼轴长度具有良好的可靠性和准确性,为临床生物测量提供了新的选择。 展开更多
关键词 iol-master A型超声 前房深度 眼轴长度
下载PDF
IOL-Master在Oxane HD填充眼眼轴测量中的应用 被引量:2
6
作者 吴敏 肖丽波 +2 位作者 胡竹林 薛黎萍 李云琴 《眼科新进展》 CAS 北大核心 2014年第11期1049-1051,共3页
目的分析应用IOL-Master测量重硅油Oxane HD填充眼眼轴长度的效果。方法收集2011年5月至2013年5月在我院就诊的36例(36眼)重硅油Oxane HD填充眼患者,分别应用A超和IOL-Master进行眼轴测量,并进行人工晶状体度数测算,在重硅油取出联合... 目的分析应用IOL-Master测量重硅油Oxane HD填充眼眼轴长度的效果。方法收集2011年5月至2013年5月在我院就诊的36例(36眼)重硅油Oxane HD填充眼患者,分别应用A超和IOL-Master进行眼轴测量,并进行人工晶状体度数测算,在重硅油取出联合超声乳化白内障摘出人工晶状体植入术后1个月应用A超和IOL-Master进行第二次眼轴测量,3个月时进行屈光检查,对两种检查的结果进行对比分析。结果术前眼轴长度A超测量为(26.3±3.6)mm,IOL-Master测量为(26.2±3.7)mm;术后1个月眼轴长度A超测量为(26.2±3.6)mm,IOL-Master测量为(26.2±3.7)mm。术前术后A超测量结果之间、IOL-Master测量结果之间,以及术前IOL-Master测量结果与术后A超测量结果之间差异均无统计学意义(均为P〉0.05),而术前A超测量结果与术后IOL-Master测量结果差异有统计学意义(P=0.030),A超测量结果较IOL-Master测量结果眼轴较长。术前IOL Master测量的人工晶状体度数预估术后屈光状态为-0.36~0.08(-0.11±0.13)D,术后3个月等效球镜度为-0.41~0.11(-0.11±0.14)D。用IOL-Master计算的预计术后屈光度与术后真实屈光度比较差异无统计学意义(P〉0.05)。结论对于重硅油Oxane HD填充眼的眼轴测量,应首选IOL-Master测量,对于屈光间质混浊、患者无法固视而不能进行IOL-Master检查的患者眼轴可采用A超测量。 展开更多
关键词 iol-master A超 眼轴 重硅油填充眼 Oxane HD
下载PDF
超声生物显微镜与IOL-Master测量人眼睫状沟直径的比较性研究 被引量:2
7
作者 宁琳 孔珺 +1 位作者 史铭宇 张劲松 《国际眼科杂志》 CAS 2008年第11期2271-2273,共3页
目的:比较分析超声生物显微镜(ultrasound biomicroscopy,UBM)与IOL-Master测量人眼睫状沟直径的差异,为更准确地计算有晶状体眼后房型人工晶状体植入术(phakicposterior chamber intraocular lens,PPCIOL)也称为可植入的接触镜(implant... 目的:比较分析超声生物显微镜(ultrasound biomicroscopy,UBM)与IOL-Master测量人眼睫状沟直径的差异,为更准确地计算有晶状体眼后房型人工晶状体植入术(phakicposterior chamber intraocular lens,PPCIOL)也称为可植入的接触镜(implantable contact lens,ICL)的直径提供客观依据(以下简称ICL),从而有效减少术后并发症。方法:选取植入ICL术后1mo的高度近视眼患者32例(60眼)和正视对照组人群28例(48眼),分别作为实验组和对照组,对照组要求排除任何眼科手术史。应用UBM分别测量实验组和对照组的睫状沟直径;应用IOL-Master测量实验组和对照组的角膜横径即水平白到白的距离(whitetowhite,W-W),将所得的数据进行统计学分析。结果:植入ICL后1mo患者的UBM测得的睫状沟直径与IOL-Master测得的W-W值比较其差异有统计学意义(t=2.023,1.988;P<0.05);健康人眼的UBM测得的睫状沟直径与IOL-Maste测得的W-W值比较其差异有统计学意义(P<0.05);ICL术后患者与健康眼的UBM测得的睫状沟直径值比较其差异无统计学意义;二者的IOL-Master测得的W-W值比较其差异也无统计学意义。结论:UBM可以作为测量人眼睫状沟直径的工具;应用IOL-Master眼外测得W-W值与UBM测得的睫状沟直径值是有区别的,我们更倾向于应用UBM测得的值;人眼是存在解剖变异的,这些变异会增加ICL植入的危险性。 展开更多
关键词 超声生物显微镜 iol-master 睫状沟直径 角膜横径
下载PDF
IOL-Master在人工晶状体屈光度计算中的精确性研究 被引量:5
8
作者 陈伟 张广斌 +1 位作者 毛祖红 何雪洪 《眼外伤职业眼病杂志》 北大核心 2008年第7期530-532,共3页
目的评价IOL-Master在人工晶状体屈光度计算中的临床应用价值。方法对160眼白内障分别运用IOL-Master与A型超声波测量眼轴,术后1月、3月行屈光检查。结果IOL-Master测量眼轴:22<L≤24.5mm组平均轴长为(23.75±0.56)mm,24.5<L... 目的评价IOL-Master在人工晶状体屈光度计算中的临床应用价值。方法对160眼白内障分别运用IOL-Master与A型超声波测量眼轴,术后1月、3月行屈光检查。结果IOL-Master测量眼轴:22<L≤24.5mm组平均轴长为(23.75±0.56)mm,24.5<L≤26mm组平均轴长为(25.21±0.61)mm,L>26.0mm组平均轴长为(28.87±0.58)mm。A型超声波测量眼轴,上述3个组平均轴长依次为:(23.68±0.81)mm,(25.01±0.90)mm,(29.33±1.02)mm。术后1月,L>26.0mm组,A超组和IOL-Master组的平均等效球镜屈光度误差为(1.449±0.723)D及(0.875±0.682)D(P<0.001)。术后3月,L>26.0mm组,A超组和IOL-Master组的平均等效球镜屈光度误差为(1.345±0.714)D及(0.865±0.683)D(P<0.001)。结论IOL-Master在人工晶状体屈光度计算方面具有极高的临床应用价值。 展开更多
关键词 iol-master A超 晶状体 人工
下载PDF
IOL-Master测量硅油眼眼轴长的精确度评价 被引量:1
9
作者 王春霞 马立威 +1 位作者 于紫燕 张劲松 《中国医科大学学报》 CAS CSCD 北大核心 2012年第6期536-537,543,共3页
目的评价IOL-Master测量硅油填充眼眼轴长的精确度。方法采用IOL-Master测定玻璃体切割联合眼内硅油填充术3~6个月后行硅油取出术的30例眼的眼轴长度。其中18例在硅油取出同时植入人工晶体(IOL),植入前后分别测量眼轴长。结果硅油取... 目的评价IOL-Master测量硅油填充眼眼轴长的精确度。方法采用IOL-Master测定玻璃体切割联合眼内硅油填充术3~6个月后行硅油取出术的30例眼的眼轴长度。其中18例在硅油取出同时植入人工晶体(IOL),植入前后分别测量眼轴长。结果硅油取出术前后的眼轴平均长度分别为(24.27±3.01)mm和(24.26±2.79)mm,2组间差异无统计学意义。IOL-Master和A超2种方法测量硅油眼的眼轴长度无显著差异。结论 IOL-Master测量硅油眼眼轴长的精确度高,可用于硅油取出联合IOL植入的IOL度数计算。 展开更多
关键词 iol-master 眼轴 硅油眼
下载PDF
IOL-Master测量人工晶体屈光度长期稳定性研究 被引量:2
10
作者 施炜 周欣 《实用老年医学》 CAS 2013年第12期998-999,共2页
目的通过对白内障超声乳化术的术前及术后IOL-Master测量结果及验光结果比较,了解IOLMaster测量人工晶体屈光度长期稳定性。方法对2011年4~10月我院行白内障超声乳化摘除及人工晶状体植入术的年龄相关性白内障11例17眼的白内障进行术前I... 目的通过对白内障超声乳化术的术前及术后IOL-Master测量结果及验光结果比较,了解IOLMaster测量人工晶体屈光度长期稳定性。方法对2011年4~10月我院行白内障超声乳化摘除及人工晶状体植入术的年龄相关性白内障11例17眼的白内障进行术前IOL-Master测量人工晶状体度数,术后8~14月复测并与综合验光仪验光结果比较。结果白内障术后眼轴测量均缩短,与术前相比有显著性差异(P【0.01)。术后实际验光球镜度数与术前IOL-Master计算后预留度数相比均减少,有显著性差异(P【0.01);术后角膜曲率及角膜散光无显著性差异;散光轴向改变,有显著性差异(P【0.05)。结论 IOL-Master仪的测量准确性好,重复性高,为达到最佳术后预期,应在检测预期度数上适当增加度数。 展开更多
关键词 iol-master 人工晶体 屈光度
下载PDF
Comparison of IOL-Master 700 and IOL-Master 500 biometers in ocular biological parameters of adolescents 被引量:5
11
作者 Qiang Shi Guang-Yan Wang +1 位作者 Yu-Hong Cheng Cheng Pei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第7期1013-1017,共5页
AIM:To compare the differences and consistency of IOL-Master 700 biometers applying swept optical coherence tomography with the conventional IOL-Master 500 applying partial coherence interference in terms of the ocula... AIM:To compare the differences and consistency of IOL-Master 700 biometers applying swept optical coherence tomography with the conventional IOL-Master 500 applying partial coherence interference in terms of the ocular biological parameters in adolescents with ametropia.METHODS:A total of 110 adolescents(110 eyes)with ametropia were collected,including 55 males and 55 females;age 10.69±2.81 y.Ocular biological measurements were taken by IOL-Master 700 and IOL-Master 500 respectively to obtain biological parameters including axial length(AL),mean corneal anterior surface keratometry(K_(m)),anterior chamber depth(ACD),and horizontal corneal diameter(WTW).Paired t-test was used to compare the differences between the two instruments.The intra-group correlation coefficient(ICC)and the Bland-Altman analysis were used to evaluate the consistency of parameter measurements between the two instruments for the four biological parameters.RESULTS:Statistical analysis showed that there was no significant difference in the K_(m)value measured by IOL-Master 700 and IOL-Master 500(t=-1.644,P=0.116).The average differences of the AL,ACD,and WTW distances between the two instruments are 0.028,0.101 and 0.064 mm respectively,and the differences are statistically significant(t=2.644,12.505,3.911,P<0.001).The consistency study results indicated high correlation in the measurement of AL,K_(m),ACD and WTW between the two instruments(ICC=0.994,0.873,0.927,0.912).CONCLUSION:The novel biometric instrument IOL-Master 700 makes no difference with IOL-Master 500 in the measurement of K_(m).There are some differences in the values of AL,ACD,and WTW.However,the two instruments show good consistency in these four biological measurements.The measured values of K_(m)are interchangeable between the instruments.These two types of biometrics can be used as mutual reference in consideration of that the differences in AL,ACD,and WTW measurements are not sufficient to produce clinically meaningful differences. 展开更多
关键词 MYOPIA adolescents axial length iol-master 700 iol-master 500
下载PDF
综合性护理干预在Zeiss IOL-Master系统测量人工晶体度数中的应用 被引量:1
12
作者 冯晓霞 蓝诚红 丘亮辉 《护理实践与研究》 2018年第13期93-94,共2页
目的探讨综合性护理干预应用于Zeiss IOL-Master系统测量人工晶体度数的临床价值。方法从2014年6月至2016年6月随机选取在我院治疗白内障疾病的患者200例作为研究对象,并随机等分为对照组和试验组,对照组采取常规护理干预;试验组采用综... 目的探讨综合性护理干预应用于Zeiss IOL-Master系统测量人工晶体度数的临床价值。方法从2014年6月至2016年6月随机选取在我院治疗白内障疾病的患者200例作为研究对象,并随机等分为对照组和试验组,对照组采取常规护理干预;试验组采用综合性护理干预,比较两组患者依从性、满意率以及干预后检查所需要的时间。结果试验组患者依从率高于对照组(P<0.05),满意率高于对照组(P<0.05),检查时间短于对照组(P<0.05)。结论在Zeiss IOL-Master系统测量人工晶体中采用综合性护理干预不仅能提高患者的依从性和满意度,更利于缩短患者的检查时间。 展开更多
关键词 iol-master系统 人工晶体 综合护理 白内障
下载PDF
IOL-Master与改良A超联合自动角膜曲率仪法测量硅油填充眼轴长的比较
13
作者 马红蕾 韩瑶 +3 位作者 高彦军 段佳良 杨欣 王红霞 《第三军医大学学报》 CAS CSCD 北大核心 2012年第23期2430-2432,共3页
目的比较IOL-Master与改良A超在硅油填充眼轴长测量方面的准确性,了解其各自的特性与临床应用价值。方法选取2011年6月至2012年4月在我院行玻璃体切割硅油填充术患者27例(27眼),术前术后分别采用IOL-Master、改良A超联合自动角膜曲率计... 目的比较IOL-Master与改良A超在硅油填充眼轴长测量方面的准确性,了解其各自的特性与临床应用价值。方法选取2011年6月至2012年4月在我院行玻璃体切割硅油填充术患者27例(27眼),术前术后分别采用IOL-Master、改良A超联合自动角膜曲率计法测量眼轴长和角膜曲率,并对结果进行分析比较。结果 IOL-Master测量患者手术前后眼轴长精确度比较接近,差异无统计学意义[(23.84±0.69)mm vs(23.39±0.88)mm,P>0.05];采用改良A超测量患者手术前后眼轴长比较差异无统计学意义[(23.75±0.68)mm vs(23.80±0.78)mm,P>0.05]。采用IOL-Master和改良A超两种方法测量患者手术前后眼轴长差异也无统计学意义(P>0.05)。结论 IOL-Master和改良A超均可较准确对硅油填充眼进行生物学测量,各有优缺点。临床应用时应结合实际情况,有针对性地选择。 展开更多
关键词 iol-master 改良A超 硅油填充眼 眼轴长
下载PDF
IOl-master700和Pentacam测量Kappa角一致性分析
14
作者 卢建群 乐原 +2 位作者 毕娟 罗静 杜慧斌 《中医眼耳鼻喉杂志》 2021年第1期16-18,共3页
目的探讨Pentacam眼前节分析系统与IOL-master 700测量Kappa角的差异性和一致性。方法横断面研究。选取2019年03月01-04月01在乐山市眼科中心性白内障术前检查患者71例(121只眼)。其中男性40例,女性31例;年龄(62±17岁)。分别用Pent... 目的探讨Pentacam眼前节分析系统与IOL-master 700测量Kappa角的差异性和一致性。方法横断面研究。选取2019年03月01-04月01在乐山市眼科中心性白内障术前检查患者71例(121只眼)。其中男性40例,女性31例;年龄(62±17岁)。分别用Pentacam、IOLMaster 700进行X值及Y值测量,采用方差分析及LSD-t比较组间差异性,组内相关系数(ICC)及Bland-Altman法评价仪器的一致性。结果方差分析显示,两种仪器测量X值无统计学意义(F=0.496,P>0.05),Y值无统计学意义(F=0.030,P>0.05),两种仪器各测量值间ICC为0.667、0.689,Cronbach’s Alpha为0.79、0.816,显示两种仪器测量结果可信度好。Bland-Altman分析显示Pentacam与IOLMaster 700测量X值比较,有7/121(5.8%)个点位于95%LoA外,一致性好,差值范围为(-0.19~0.22);Y值测量,有8/121(6.7%)个点位于95%LoA外,一致性好,差值范围为(-0.14~0.15),一致性好。结论两种仪器测量KAPPA角的差异性小,一致性均较好。 展开更多
关键词 iol-master 700 PENTACAM KAPPA角 差异性 重复性
下载PDF
玻璃酸钠滴眼液点眼对中重度干眼及无干眼IOL-Master 700生物测量参数的影响 被引量:12
15
作者 李景兰 叶子 +3 位作者 马天驹 高艺 杨青华 李朝辉 《中华实验眼科杂志》 CAS CSCD 北大核心 2020年第3期186-191,共6页
目的研究玻璃酸钠滴眼液点眼对中重度干眼及无干眼者IOL-Master 700生物测量参数的影响。方法采用非随机对照临床研究方法。招募2018年8月1日至2019年1月1日于解放军总医院第一医学中心眼科门诊就诊的中重度干眼患者作为中重度干眼组,... 目的研究玻璃酸钠滴眼液点眼对中重度干眼及无干眼者IOL-Master 700生物测量参数的影响。方法采用非随机对照临床研究方法。招募2018年8月1日至2019年1月1日于解放军总医院第一医学中心眼科门诊就诊的中重度干眼患者作为中重度干眼组,同期选取无干眼者作为无干眼组,每组各40例,均以右眼为试验眼。所有受试者分别于质量分数0.1%玻璃酸钠滴眼液点眼前、点眼后5、10及15 min行IOL-Master 700生物测量,分析2个组玻璃酸钠点眼前后不同时间眼轴长度(AL)、中央角膜厚度(CCT)、角膜曲率、人工晶状体(IOL)度数的变化。结果中重度干眼组CCT、K1和K2均大于无干眼组,差异均有统计学意义(均P<0.05)。中重度干眼组玻璃酸钠滴眼液点眼后5 min和10 min,AL、CCT及IOL度数较点眼前增大,K1较点眼前减小,差异均有统计学意义(均P<0.05/3);点眼后5 min,17.5%(7/40)中重度干眼患者的IOL度数增大0.5 D。点眼后10 min,22.5%(9/40)的中重度患者IOL度数增大0.5 D或1.0 D。点眼后15 min,各IOL-Master测量参数与点眼前比较,差异均无统计学意义(均P>0.05)。无干眼组点眼后5 min AL和CCT较点眼前增大,IOL度数较点眼前减小,差异均有统计学意义(均P<0.01)。点眼后10 min及15 min,AL和CCT较点眼前增大,差异均有统计学意义(均P<0.05/3),但IOL度数比较差异无统计学意义(均P>0.05)。结论玻璃酸钠滴眼液点眼后5~10 min IOL-Master生物测量中重度干眼患者IOL度数增大,点眼后5 min内无干眼者IOL度数减小,该结果对临床上IOL-Master的正确使用有指导意义。 展开更多
关键词 干眼 人工泪液 白内障 iol-master 人工晶状体度数
下载PDF
A超与IOL-Master测量老年近视患者眼轴长度精确性比较 被引量:6
16
作者 杜淑芳 张辉 +1 位作者 仲炜 张珍珍 《中国老年学杂志》 CAS CSCD 北大核心 2011年第24期4799-4801,共3页
目的比较光学相干生物测量仪(ZeissIOL-Master)和A超对近视眼眼轴长度测量的精确性,分析引起测量误差的主要原因,为指导临床应用提供参考资料。方法收集2006年5月至2007年8月在我院门诊就诊的部分50~70岁透明晶状体近视人群,根据近视... 目的比较光学相干生物测量仪(ZeissIOL-Master)和A超对近视眼眼轴长度测量的精确性,分析引起测量误差的主要原因,为指导临床应用提供参考资料。方法收集2006年5月至2007年8月在我院门诊就诊的部分50~70岁透明晶状体近视人群,根据近视度数分为4组,即A组:低度近视组(<-3.00 D)30眼,B组:中度近视组(-3.00 D~<-6.00 D)28眼,C组高度近视组(≥-6.00 D~<-10.00 D)28眼,D组超高度近视组(≥-10.00 D)50眼。其中对D组中不适合行角膜屈光手术,又有强烈摘镜愿望的患者称为D1组(21例42眼),行透明晶状体皮质吸出及人工晶状体植入术。术后3个月对所有手术患者进行规范的主觉验光,得出患者术后的屈光状态,并比较两种方法的绝对屈光误差值。结果 <-10.00 D的患者用A超法和IOL-Master法分别测得的眼轴长度差异均无显著性;对≥-10.00 D同一患者同一患眼IOL-Master测得值普遍长于A超,有显著性差异;电脑验光仪和IOL-Master测量角膜曲率结果比较无显著性差异。A超法和IOL-Master法绝对屈光误差在≤±0.50 D患者和≤±1.00 D患者之间比较无显著差异。结论①在<-10.00 D的近视人群中,用A超和IOL-Master两种方法测得的眼轴长度相同;在≥-10.00 D的超高度近视人群中,两种方法测得结果有差异I,OL-Master法平均比A超法长0.28 mm。②行透明晶状体摘除联合人工晶状体植入术的患者用两种方法测得的眼轴长度虽有差异,但术后效果无明显差异。③IOL-Master测量人工晶状体度数准确,有A超生物测量无法比拟的优势,但也有它的局限性,不能完全替代传统超声生物测量。 展开更多
关键词 A超 iol-master 眼轴 近视
下载PDF
应用IOL-Master对大学生近视眼屈光成分的生物学测量研究 被引量:13
17
作者 杜媛媛 张文芳 +4 位作者 律鹏 任婉娜 李玉婷 王万鹏 周然 《国际眼科杂志》 CAS 2013年第5期984-987,共4页
目的:应用IOL-Master测量大学生近视眼的眼轴长度(AL),水平、垂直角膜屈光力(K1,K2),前房深度(ACD)及角膜直径,探讨大学生近视眼各屈光成分值与屈光度的关系以及大学生近视眼的主要成因。方法:大学生近视患者1059例2118眼,经电脑验光按... 目的:应用IOL-Master测量大学生近视眼的眼轴长度(AL),水平、垂直角膜屈光力(K1,K2),前房深度(ACD)及角膜直径,探讨大学生近视眼各屈光成分值与屈光度的关系以及大学生近视眼的主要成因。方法:大学生近视患者1059例2118眼,经电脑验光按等效屈光度分为三组:A组低度近视<-3.00D(738眼),B组中度近视-3.00~-6.00D(989眼),C组高度近视>-6.00D(391眼)。采用光学相干生物测量仪(Zeiss,IOL-Master)测量其AL,K1,K2,ACD及角膜直径,计算眼轴长度与角膜曲率的比值AL/CR,数据采用SPSS18.0统计分析。结果:随着近视屈光度的增加,眼轴长度明显增加,两者之间存在显著相关性(P<0.01),且各组间具有显著差异性(P<0.01);K1在A组与B组间差异无显著性(P>0.05),K2在各组间具有差异性(P<0.05),但K1和K2仅与中度近视的屈光度存在相关性(P<0.05);各组AL与K1、K2呈负相关,且有显著统计学意义(P<0.01);ACD在B组与C组间差异无显著性(P>0.05),低度近视的屈光度与ACD存在显著相关性(P<0.01);角膜直径在各组间无显著性差异(P>0.05),且与屈光度无相关性(P>0.05);AL/CR比值3.183±0.132,近视屈光度与AL/CR比值呈负相关(r=-0.761,P=0.000)。结论:轴性近视是大学生近视的主要类型。大学生中度近视是眼轴与角膜屈光力共同作用所致;ACD对大学生近视屈光度影响较小;角膜直径对大学生近视屈光度无影响。 展开更多
关键词 光学相干生物测量仪 大学生 近视 眼轴长度 水平 垂直角膜屈光力 前房深度 角膜直径
下载PDF
Sirius、IOL-Master和SW-9000测量角膜水平直径的比较研究 被引量:4
18
作者 李岩 李国保 +1 位作者 谌慧 成拾明 《湖北医药学院学报》 CAS 2020年第6期571-575,共5页
目的:比较Sirius、IOL-Master与SW-9000测量角膜水平直径的相关性和差异性,并对三种仪器的测量结果进行一致性评价。方法:分别使用Sirius、IOL-Master和SW-9000测量80例屈光不正者的角膜水平直径。数据分析采用单因素方差分析、简单线... 目的:比较Sirius、IOL-Master与SW-9000测量角膜水平直径的相关性和差异性,并对三种仪器的测量结果进行一致性评价。方法:分别使用Sirius、IOL-Master和SW-9000测量80例屈光不正者的角膜水平直径。数据分析采用单因素方差分析、简单线性相关及Bland-Altman分析。结果:Sirius、IOL-Master和SW-9000测量的角膜水平直径分别为(11.68±0.35) mm、(11.85±0.35) mm和(12.15±0.73) mm,两两之间测量差值分别为(-0.17±0.08) mm、(-0.48±0.08) mm、(-0.30±0.08) mm,差异均具有统计学意义(P<0.05);Sirius与IOL-Master,Sirius与SW-9000,IOL-Master与SW-9000测量结果均有相关性(r值分别为0.882、0.432、0.502,均P<0.05);Sirius与IOL-Master,Sirius与SW-9000,IOL-Maste与SW-9000测量结果的95%LoA分别为(-0.51~0.16)mm、(-1.8~0.8)mm、(-1.5~0.9) mm。结论:三种仪器测量的角膜水平直径值有一定的相关性,测量结果差异较大,SW-9000测量值最大,IOL-Master测量值次之,Sirius测量值最小,测量结果不能替代使用,应结合临床实践谨慎选择。 展开更多
关键词 Sirius iol-master SW-9000 角膜水平直径 一致性
下载PDF
IOL-Master的临床应用观察 被引量:7
19
作者 钟勇 宋德禄 +1 位作者 金玉梅 许鹏 《国际眼科杂志》 CAS 2008年第6期1181-1183,共3页
目的:比较Zeiss IOL-Master与传统超声生物测量在人工晶状体测量中的准确性,并探讨不同测量方法的临床应用特点。方法:分析2007-11/2008-01在我院行白内障摘除及人工晶状体植入术的患者91例147眼,根据眼轴长度(L)分别分为五组(L≤22mm,2... 目的:比较Zeiss IOL-Master与传统超声生物测量在人工晶状体测量中的准确性,并探讨不同测量方法的临床应用特点。方法:分析2007-11/2008-01在我院行白内障摘除及人工晶状体植入术的患者91例147眼,根据眼轴长度(L)分别分为五组(L≤22mm,22mm<L≤24.5mm,24.5mm<L≤26mm,26mm<L≤28mm,L>28mm),术前分别用ZeissIOL-Master,超声生物测量仪及角膜曲率计测量眼轴长度,角膜曲率和计算人工晶状体度数,并将结果进行比较。结果:用ZeissIOL-Master和超声生物测量仪测得的眼轴长度:L≤22mm组分别为21.69±0.298mm和21.97±0.623mm(P>0.05);22mm<L≤24.5mm组分别为23.15±0.567mm和23.50±1.396mm(P>0.05);24.5mm<L≤26mm组分别为25.16±0.425mm和25.20±0.485mm(P>0.05);26mm<L≤28mm组分别26.88±0.637mm和26.95±0.668mm(P>0.05);L>28mm组分别为31.59±1.852mm和31.22±1.718mm(P>0.05)。两种方法测得的眼轴长度在各组间无显著差异性。用IOL-Master和超声生物测量仪测得的各组的人工晶状体度数:L≤22mm组分别为23.73±1.29D和22.94±1.44D(P>0.05);22mm<L≤24.5mm组分别为20.52±1.47D和20.44±1.51D(P>0.05);24.5mm<L≤26mm组分别14.95±2.81D和15.23±3.00D(P>0.05);L>28mm组分别为-4.28±4.52D和-3.53±4.76D(P>0.05),显示各组间无显著性差异。IOLMaster和角膜曲率计检测到的角膜曲率分别为43.65±1.62和43.70±1.71,两者比较无显著差异(P>0.05)。结论:IOL-Master用于人工晶状体度数的测量具有非接触、精确性高、操作简单、安全可靠和患者容易接受的特点。而传统的超声生物测量要接触患者角膜,对操作者的手法及患者的配合程度要求较高,但在屈光间质混浊明显的患眼测量中则明显较IOL-Master更为准确,因此临床上应根据个体情况选择不同的测量方法及计算公式以获得准确地人工晶状体度数。 展开更多
关键词 IOL—Master 人工晶状体 超声生物测量
下载PDF
IOL-Master应用于人工晶状体测量的研究进展 被引量:6
20
作者 邵珺 朱弼珺 樊莹 《眼科新进展》 CAS 北大核心 2009年第4期315-319,共5页
白内障术前人工晶状体(intraocular lens,IOL)度数测量的精确性直接影响术后屈光结果。IOL-Master是一种较新的非接触性测量IOL度数的手段。本文就IOL-Master测量IOL的原理、应用、优缺点以及最新进展作一综述。
关键词 IOL—Master 前房深度 眼轴 人工晶状体度数
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部