In this paper, the edge detection for a medical image is performed based on Sobel operator, and the bounding box is obtained, by which the effective medical sub-image is extracted. Then, the centroid and the normalize...In this paper, the edge detection for a medical image is performed based on Sobel operator, and the bounding box is obtained, by which the effective medical sub-image is extracted. Then, the centroid and the normalized central moments of the medical sub-image are calculated, and the rotation angle a is obtained by minimizing the second-order central moment based on its rotation invariance. Finally, the whole medical image is rotated around the centroid by --a to correct the tilted image. F^rthermore, inspired by the uniformity degree of the image, the rotation angle ct is revised, which achieves a better correction effect and performance. The experimental results show that the proposed algorithms are fairly reliable and accurate for the determination of tilt angles, and are practical and effective tilt correction techniques.展开更多
In this paper a millimeter-wave (MMW) squint indirect holographic method is presented, which is suitable for imaging with a large field-of-view. The proposed system employs the squint operation mode to remove the ba...In this paper a millimeter-wave (MMW) squint indirect holographic method is presented, which is suitable for imaging with a large field-of-view. The proposed system employs the squint operation mode to remove the background and twin- image interferences, which achieves a similar effect to off-axis holography but leaves out the large-aperture quasi-optical component. The translational scanning manner enables a large field of view and ensures the image uniformity, which is difficult to realize in off-axis holography. In addition, a corresponding imaging algorithm for the presented scheme is developed to reconstruct the image from the recorded hologram. Some imaging results on typical objects, obtained with electromagnetic simulation, demonstrate good performance of the imaging scheme and validate the effectiveness of the image reconstruction algorithm.展开更多
基金supported by Foundation of 11th Five-year Plan for Key Construction Academic Subject (Optics) of Hunan Province,PRCScientific Research Fund of Hunan Provincial Education Department, PRC (No. 06C581)
文摘In this paper, the edge detection for a medical image is performed based on Sobel operator, and the bounding box is obtained, by which the effective medical sub-image is extracted. Then, the centroid and the normalized central moments of the medical sub-image are calculated, and the rotation angle a is obtained by minimizing the second-order central moment based on its rotation invariance. Finally, the whole medical image is rotated around the centroid by --a to correct the tilted image. F^rthermore, inspired by the uniformity degree of the image, the rotation angle ct is revised, which achieves a better correction effect and performance. The experimental results show that the proposed algorithms are fairly reliable and accurate for the determination of tilt angles, and are practical and effective tilt correction techniques.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.11174280,60990323,and 60990320)the Knowledge Innovation Program of the Chinese Academy of Sciences (Grant No.YYYJ-1123)
文摘In this paper a millimeter-wave (MMW) squint indirect holographic method is presented, which is suitable for imaging with a large field-of-view. The proposed system employs the squint operation mode to remove the background and twin- image interferences, which achieves a similar effect to off-axis holography but leaves out the large-aperture quasi-optical component. The translational scanning manner enables a large field of view and ensures the image uniformity, which is difficult to realize in off-axis holography. In addition, a corresponding imaging algorithm for the presented scheme is developed to reconstruct the image from the recorded hologram. Some imaging results on typical objects, obtained with electromagnetic simulation, demonstrate good performance of the imaging scheme and validate the effectiveness of the image reconstruction algorithm.