期刊文献+
共找到33篇文章
< 1 2 >
每页显示 20 50 100
Dynamic Contrast-Enhanced Perfusion MR Imaging Measurements of Endothelial Permeability: Differentiation between Atypical and Typical Meningiomas 被引量:10
1
作者 Law M Zagzag D +2 位作者 Golfinos JG Knopp EA Johnson G 《中国神经肿瘤杂志》 2003年第3期149-149,共1页
BACKGROUND: AND PURPOSE: The measurement of relative cerebral blood volume (rCBV) and the volume transfer constant (K(trans)) by means of dynamic contrast-enhanced (DCE) perfusion MR imaging (pMRI) can be useful in ch... BACKGROUND: AND PURPOSE: The measurement of relative cerebral blood volume (rCBV) and the volume transfer constant (K(trans)) by means of dynamic contrast-enhanced (DCE) perfusion MR imaging (pMRI) can be useful in characterizing brain tumors. The purpose of our study was to evaluate the utility of these measurements in differentiating typical meningiomas and atypical meningiomas. METHODS: Fifteen patients with pathologically confirmed typical meningiomas and seven with atypical meningiomas underwent conventional imaging and DCE pMRI before resection.rCBV measurements were calculated by using standard intravascular 展开更多
关键词 MR in DCE Dynamic Contrast-Enhanced Perfusion MR imaging measurements of Endothelial Permeability Differentiation between Atypical and Typical Meningiomas of
下载PDF
In-line imaging measurements of particle size,velocity and concentration in a particulate two-phase flow 被引量:11
2
作者 Xiaozhen Chen Wu Zhou +2 位作者 Xiaoshu Cai Mingxu Su Hailong Liu 《Particuology》 SCIE EI CAS CSCD 2014年第2期106-113,共8页
A novel method is developed for in-line measurements of particle size, velocity and concentration in a dilute, particulate two-phase flow based on trajectory image processing. The measurement system consists of a comm... A novel method is developed for in-line measurements of particle size, velocity and concentration in a dilute, particulate two-phase flow based on trajectory image processing. The measurement system consists of a common industrial CCD camera, an inexpensive LED light and a telecentric lens. In this work, the image pre-processing steps include stitching, illumination correction, binarization, denoising, and the elimination of unreal and defocused particles. A top-hat transformation is found to be very effective for the binarization of images with non-uniform background illumination. Particle trajectories measured within a certain exposure time are used to directly obtain particle size and velocity. The particle concentration is calculated by using the statistics of recognized particles within the field of view. We validate our method by analyzing experiments in a gas-droplet cyclone separator. This in-line image processing method can significantly reduce the measurement cost and avoid the data inversion process involved in the light scattering method. 展开更多
关键词 In-line measurements Particle trajectory Image processing Multi-parameters
原文传递
Machine Vision Based Measurement of Dynamic Contact Angles in Microchannel Flows 被引量:5
3
作者 Valtteri Heiskanen Kalle Marjanen Pasi Kallio 《Journal of Bionic Engineering》 SCIE EI CSCD 2008年第4期282-290,共9页
When characterizing flows in miniaturized channels, the determination of the dynamic contact angle is important. By measuring the dynamic contact angle, the flow properties of the flowing liquid and the effect of mate... When characterizing flows in miniaturized channels, the determination of the dynamic contact angle is important. By measuring the dynamic contact angle, the flow properties of the flowing liquid and the effect of material properties on the flow can be characterized. A machine vision based system to measure the contact angle of front or rear menisci of a moving liquid plug is described in this article. In this research, transparent flow channels fabricated on thermoplastic polymer and sealed with an adhesive tape are used. The transparency of the channels enables image based monitoring and measurement of flow variables, including the dynamic contact angle. It is shown that the dynamic angle can be measured from a liquid flow in a channel using the image based measurement system. An image processing algorithm has been developed in a MATLAB environment. Images are taken using a CCD camera and the channels are illuminated using a custom made ring light. Two fitting methods, a circle and two parabolas, are experimented and the results are compared in the measurement of the dynamic contact angles. 展开更多
关键词 digital image processing machine vision MICROFLUIDICS microchannel flow dynamic contact angle image based measurement
下载PDF
AUTOMATED IMAGE MATCHING WITH CODED POINTS IN STEREOVISION MEASUREMENT 被引量:1
4
作者 Dong Mingli Zhou Xiaogang +2 位作者 Zhu Lianqing LU Naiguang Sun Yunan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第3期453-456,共4页
A coding-based method to solve the image matching problems in stereovision measurement is presented. The solution is to add and append an identity ID to the retro-reflect point, so it can be identified efficiently und... A coding-based method to solve the image matching problems in stereovision measurement is presented. The solution is to add and append an identity ID to the retro-reflect point, so it can be identified efficiently under the complicated circumstances and has the characteristics of rotation, zooming, and deformation independence. Its design architecture and implementation process in details based on the theory of stereovision measurement are described. The method is effective on reducing processing data time, improving accuracy of image matching and automation of measuring system through experiments. 展开更多
关键词 Coded point Image matching Stereovision measurement
下载PDF
Laser triangulation measurement of the level in a coal silo 被引量:2
5
作者 Sun Jiping Jiang Jing 《Mining Science and Technology》 EI CAS 2011年第6期881-884,共4页
Laser triangulation theory was used to develop a novel contact-free method for measuring the coal level in a silo under harsh environmental conditions found in coal mines, such as the presence of dense dust, high humi... Laser triangulation theory was used to develop a novel contact-free method for measuring the coal level in a silo under harsh environmental conditions found in coal mines, such as the presence of dense dust, high humidity, and low illumination. A laser source and a camera were mounted at the top of the silo. The laser spot projected into the silo was imaged by the camera. The pinhole imaging principle allows the level to be found from the lateral shift of the spot image on the sensor. A pre-calibrated look-up table of the coal depth versus spot position was used to obtain the depth. The measurement accuracy depends on the step size used during pre-calibration. The actual application of a device designed according to these principles shows that it is easy to implement. The detection of the coal level in a silo at the low illumination level found in coal mines is demonstrated. 展开更多
关键词 Laser triangulation measurement Coal level of coal silo Image segmentation Look-up table
下载PDF
Recent Developments of Image Based Measurement Methods for Application to Transonic Flows in Industrial Wind Tunnels
6
作者 J.KOMPENHANS J.AGOCS +16 位作者 Y.EGAMI R.ENGLER U.FEY H.FRAHNERT K.de GROOT U.HENNE T.KIRMSE C.KLEIN F.KLINGE R.KONRATH L.KOOP H.MATTNER D.OTTER D.PALLEK W.SACHS A.SCHRDER B.STASICKI 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2006年第2期114-125,共12页
The experimental investigation of unsteady complex flow fields in wind tunnels requires advanced measurement techniques. The most important of such image based measurement techniques are those for the measurement of p... The experimental investigation of unsteady complex flow fields in wind tunnels requires advanced measurement techniques. The most important of such image based measurement techniques are those for the measurement of planar flow velocity fields, planar pressure distribution, model location and deformation, model temperature and quantitative high speed flow visualization. The applications as carried out by DLR range from low speed flows to transonic flows, from high lift configurations to propellers and rotors, from wake vortex investigations in catapult facilities and water towing tanks to investigations of vortex break down phenomena on delta wings. The capability to use image based measurement techniques in transonic flows requires dedicated technical developments and experienced scientists due to the special environment of a transonic wind tunnel. In this paper an overview of the state-of-the art of the application of image based measurement techniques in transonic flows as performed by DLR's Institute of Aerodynamics and Flow Technology will be given. 展开更多
关键词 industrial wind tunnel transonic flow image based measurement techniques pressure sensitive paint particle image velocimetry model deformation measurement techniques THERMOGRAPHY non-standard video techniques
下载PDF
Rapid Measurement of Short Fiber Content on Hertel Sample
7
作者 何晓峰 刘文耀 徐守东 《Journal of Donghua University(English Edition)》 EI CAS 2006年第1期125-129,共5页
This paper offers a new method of measuring short fiber content of cotton fibers. The method is composed of two parts: one is Hertel sampling and the other is image testing. With the help of fiber mixer, a thin and ev... This paper offers a new method of measuring short fiber content of cotton fibers. The method is composed of two parts: one is Hertel sampling and the other is image testing. With the help of fiber mixer, a thin and even cotton net is obtained on which we can get Hertel sample by using a sliver clamp. The near micro optical mechanism consists of one large area CCD and one lens with long focus. This mechanism is able to measure every cotton fiber of the test beard accurately and makes it possible to measure accumulating fibers’ amounts. On this base we can calculate short fiber content of cotton, and the experiment results show that this method is efficient. 展开更多
关键词 cotton fiber short fiber content Hertel sampling image measurement fibrogram
下载PDF
Study on the Technology of Image Measurement with High Accuracy based on Sobel Operator
8
作者 Zuobing WANG Xiaona SONG 《International Journal of Technology Management》 2015年第2期34-36,共3页
According to the basic problem of industrial production, the paper presents a monocular camera and automatic annotation ranging scheme with a ruler. The scheme eliminates a series of complex operation steps frequently... According to the basic problem of industrial production, the paper presents a monocular camera and automatic annotation ranging scheme with a ruler. The scheme eliminates a series of complex operation steps frequently used for image location of the calibration, image correction, it has simple implementation and has successfully realized precise ranging by using digital image processing technology. From the beginning of the analysis of image edge detection, edge detection principle and some common edge detection operators, and proposes an improved multi-scale edge detection algorithm, then according to the particularity of the edge proposed new edge thinning algorithm, finally mark the target point through the feature extraction, calculate the final results of fault location. 展开更多
关键词 Image Measuring Edge Detection Wavelet Transformation Edge Thinning Feature Extraction
下载PDF
Internal Flow Field Measurement of Gas Turbine Based on Optical Flow Method
9
作者 Chengyang Li 《Journal of Applied Mathematics and Physics》 2022年第6期1910-1917,共8页
The in-cylinder flow field of the internal combustion engine is an important factor affecting the quality and combustion quality of the fuel mixture in the cylinder. In order to calculate the high-precision flow field... The in-cylinder flow field of the internal combustion engine is an important factor affecting the quality and combustion quality of the fuel mixture in the cylinder. In order to calculate the high-precision flow field, the paper presents a flow field calculation method based on the optical flow algorithm. The motion of the point was calculated using the change in pixel intensity within two temporally adjacent frame images. The results show the high accuracy and resolution of the flow field at small displacement conditions. 展开更多
关键词 Optical Flow Method Particle Image Velocity measurement Flow Field Calculation
下载PDF
Image Distortion Metric Based on Total Bounded Variation 被引量:3
10
作者 Cheng Xiaogang An Mingwei Chen Qimei 《China Communications》 SCIE CSCD 2012年第2期79-85,共7页
Image definition measurement plays an important role in various image processing applications.And a reliable objective image definition metrics is critical for evaluating the definition of the restored image.In this p... Image definition measurement plays an important role in various image processing applications.And a reliable objective image definition metrics is critical for evaluating the definition of the restored image.In this paper,a novel image distortion metric based on minimal Total Bounded Variation(TBV) is presented.It is clarified that when the restored image approximates to the original clear image,the smaller the TBV is,the better the definition of the restored image is.Furthermore,the difference between the restored image and the original clear image is the smallest when the TBV is minimum.In numerical results,the TBV of the original clear image,blur image and restored image are presented and compared,and the results demonstrate the validity of the distortion metric proposed. 展开更多
关键词 TBV image definition measurement image restoration evaluation function
下载PDF
New Monitoring Technologies for Overhead Contact Line at 400 km.h-1 被引量:2
11
作者 Chul.Jin Cho Young Park 《Engineering》 SCIE EI 2016年第3期360-365,共6页
Various technologies have recently been developed for high-speed railways, in order to boost commercial speeds from 300 km.h: to 400 km.h-1. Among these technologies, this paper introduces the 400 km-h-1 class curren... Various technologies have recently been developed for high-speed railways, in order to boost commercial speeds from 300 km.h: to 400 km.h-1. Among these technologies, this paper introduces the 400 km-h-1 class current collection performance evaluation methods that have been developed and demonstrated by Korea. Specifically, this paper reports details of the video-based monitoring techniques that have been adopted to inspect the stability of overhead contact line (OCL) components at 400 km.h-1 without direct contact with any components of the power supply system. Unlike conventional OCL monitoring systems, which detect contact wire positions using either laser sensors or line cameras, the developed system measures parameters in the active state by video data. According to experimental results that were obtained at a field-test site established at a commercial line, it is claimed that the proposed mea- surement system is capable of effectively measuring OCL parameters. 展开更多
关键词 High-speed railway Overhead contact lines Condition monitoring Image processing based measurement
下载PDF
Study and application of monitoring plane displacement of a similarity model based on time-series images 被引量:5
12
作者 Xu Jiankun Wang Enyuan +1 位作者 Li Zhonghui Wang Chao 《Mining Science and Technology》 EI CAS 2011年第4期501-505,共5页
In order to compensate for the deficiency of present methods of monitoring plane displacement in similarity model tests,such as inadequate real-time monitoring and more manual intervention,an effective monitoring meth... In order to compensate for the deficiency of present methods of monitoring plane displacement in similarity model tests,such as inadequate real-time monitoring and more manual intervention,an effective monitoring method was proposed in this study,and the major steps of the monitoring method include:firstly,time-series images of the similarity model in the test were obtained by a camera,and secondly,measuring points marked as artificial targets were automatically tracked and recognized from time-series images.Finally,the real-time plane displacement field was calculated by the fixed magnification between objects and images under the specific conditions.And then the application device of the method was designed and tested.At the same time,a sub-pixel location method and a distortion error model were used to improve the measuring accuracy.The results indicate that this method may record the entire test,especially the detailed non-uniform deformation and sudden deformation.Compared with traditional methods this method has a number of advantages,such as greater measurement accuracy and reliability,less manual intervention,higher automation,strong practical properties,much more measurement information and so on. 展开更多
关键词 Plane displacement monitoring Similarity model test Time-series images Displacement measurement
下载PDF
Unsteady flow structure of an airfoil in ground effect 被引量:2
13
作者 钱建林 代钦 《Journal of Shanghai University(English Edition)》 CAS 2010年第3期228-234,共7页
Particle image velocimetry (PIV) experimental results of wake flow structure of a NACA0012 airfoil with small attack angle mounted above water surface are introduced.The experiment was carried out in a small-scale w... Particle image velocimetry (PIV) experimental results of wake flow structure of a NACA0012 airfoil with small attack angle mounted above water surface are introduced.The experiment was carried out in a small-scale wind-wave tunnel.The diameter of wind-wave tunnel test section is 1.7 m (long) × 0.4 m (width) × 0.4 m (height).The flow fields around the airfoil were measured under four diffierent conditions by varying the distance between the airfoil and the water surface.The attack angle of the airfoil was kept 10- during the experiment.For each experimental condition,the time series of particle images was captured to calculate continuous evolution of the velocity fields.The velocity fields were ensemble averaged to get the statistic parameters such as mean velocity and vorticity.Typical instantaneous velocity fields for each case are introduced to show the basic flow structure of wind surface flow separation.The aerodynamic loads acting on the airfoil are analyzed qualitatively according to the mean vorticity distribution in the flow field based on the theory of vorticity aerodynamics.The results indicate that the flow structures and drag/lift force of the airfoil alter remarkably with the changing distance between the airfoil and water surface. 展开更多
关键词 NACA0012 airfoil water surface mean vorticity field particle image velocimetry (PIV) measurement ground effect
下载PDF
Subset-based local vs.finite element-based global digital image correlation:A comparison study 被引量:2
14
作者 Bo Wang Bing Pan 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第5期200-208,共9页
Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most comm... Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most commercial DIC systems employ local DIC algorithm because of its advantages of straight forward principle and higher efficiency. However, several researchers argue that global DIC can provide better displacement results due to the displacement continuity constraint among adjacent elements. As such, thoroughly examining the performance of these two different DIC methods seems to be highly necessary. Here, the random errors associated with local DIC and two global DIC methods are theoretically analyzed at first. Subsequently, based on the same algorithmic details and parameters during analyses of numerical and real experiments, the performance of the different DIC approaches is fairly compared. Theoretical and experimental results reveal that local DIC outperforms its global counterpart in terms of both displacement results and computational efficiency when element (subset) size is no less than 11 pixels. 展开更多
关键词 Digital image correlation Displacement measurement Finite element Subset Subpixel
下载PDF
A convenient look-up-table based method for the compensation of non-linear error in digital fringe projection 被引量:9
15
作者 Chen Xiong Jun Yao +1 位作者 Jubing Chen Hong Miao 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第1期49-53,共5页
Although the structured light system that uses digital fringe projection has been widely implemented in three-dimensional surface profile measurement, the measurement system is susceptible to non-linear error. In this... Although the structured light system that uses digital fringe projection has been widely implemented in three-dimensional surface profile measurement, the measurement system is susceptible to non-linear error. In this work, we propose a convenient look-up-table-based (LUT-based) method to compensate for the non-linear error in captured fringe patterns. Without extra calibration, this LUT-based method completely utilizes the captured fringe pattern by recording the full-field differences. Then, a phase compensation map is established to revise the measured phase. Experimental results demonstrate that this method works effectively. 展开更多
关键词 Phase measurement Digital fringe projection Non-linear error compensation Digital image processing
下载PDF
Visual detection method of chamfer Ron the root bottom of textile workpiece roller
16
作者 HU Ling-hao LIU Chang jie +2 位作者 SHI Chun rain FU Lu hua LU Gang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第3期205-213,共9页
Roller is an important workpiece of automatic spinning machine. Only if the chamferR on the root bottom of roller's guide pillar meets processing accuracy requirement can the end face of one roller's guide pillar ma... Roller is an important workpiece of automatic spinning machine. Only if the chamferR on the root bottom of roller's guide pillar meets processing accuracy requirement can the end face of one roller's guide pillar match the correct position of another roller's end face on the guide hole. Therefore, the size of chamfer R on the root bottomof the roller's guide pillar has an important influence on the operating state of automatic spinning machine. In order to achieve the rapid, automatic and precise measurement of chamfer R on the root bottom of roller, an auto detection system }'or roller~ s chamfer based on computer vision technology is proposed. Firstly, the principle of measurement based on computer vision technology is introduced. And then the extraction method of charnfer^s characteristic parameters is presented, which uses image processing technique to obtain these characteristic parameters by means of collected images of roller contour, including extraction of region of interest, extraction of subpixel precise edge, segmentation of arc and line, fittingof geometric primitives, etc. Finally, after experimental verification, the measurement error is within + 5 μm and repeated accuracy is 0.1 pm. The results show that this measurement method is applicable to not only the chamfer on the textile workpiece, but also the workpieces of shaft type with various of sizes. 展开更多
关键词 textile workpiece ROLLER CHAMFER image measurement auto detection
下载PDF
Comparison of TMI and AMSR-E sea surface temperatures with Argo near-surface temperatures over the global oceans 被引量:1
17
作者 CHEN Xingrong LIU Zenghong +1 位作者 SUN Chaohui WANG Haiyan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第3期52-59,共8页
Satellite-derived sea surface temperatures(SSTs) from the tropical rainfall measuring mission(TRMM)microwave imager(TMI) and the advanced microwave scanning radiometer for the earth observing system(AMSR-E) we... Satellite-derived sea surface temperatures(SSTs) from the tropical rainfall measuring mission(TRMM)microwave imager(TMI) and the advanced microwave scanning radiometer for the earth observing system(AMSR-E) were compared with non-pumped near-surface temperatures(NSTs) obtained from Argo profiling floats over the global oceans. Factors that might cause temperature differences were examined, including wind speed, columnar water vapor, liquid cloud water, and geographic location. The results show that both TMI and AMSR-E SSTs are highly correlated with the Argo NSTs; however, at low wind speeds, they are on average warmer than the Argo NSTs. The TMI performs slightly better than the AMSR-E at low wind speeds, whereas the TMI SST retrievals might be poorly calibrated at high wind speeds. The temperature differences indicate a warm bias of the TMI/AMSR-E when columnar water vapor is low, which can indicate that neither TMI nor AMSR-E SSTs are well calibrated at high latitudes. The SST in the Kuroshio Extension region has higher variability than in the Kuroshio region. The variability of the temperature difference between the satellite-retrieved SSTs and the Argo NSTs is lower in the Kuroshio Extension during spring. At low wind speeds, neither TMI nor AMSR-E SSTs are well calibrated, although the TMI performs better than the AMSR-E. 展开更多
关键词 Argo near-surface temperature tropical rainfall measuring mission(TRMM) microwave imager advanced microwave scanning radiometer for the earth observing system sea surface temperature
下载PDF
A Thorough Evaluation of the Passive Microwave Radiometer Measurements onboard Three Fengyun-3 Satellites 被引量:3
18
作者 Xinran XIA Wenying HE +4 位作者 Shengli WU Disong FU Wei SHAO Peng ZHANG Xiangao XIA 《Journal of Meteorological Research》 SCIE CSCD 2023年第4期573-588,共16页
Microwave Radiometer Imager(MWRI) is a key payload of China’s second generation polar meteorological satellite, i.e., Fengyun-3 series(FY-3). Up to now, 5 satellites including FY-3A(2008), FY-3B(2010), FY-3C(2013), F... Microwave Radiometer Imager(MWRI) is a key payload of China’s second generation polar meteorological satellite, i.e., Fengyun-3 series(FY-3). Up to now, 5 satellites including FY-3A(2008), FY-3B(2010), FY-3C(2013), FY-3D(2018), and FY-3E(2021) have been launched successfully to provide multiwavelength, all-weather, and global data for decades. Much progress has been made on the calibration of MWRI and a recalibrated MWRI brightness temperature(BT) product(V2) was recently released. This study thoroughly evaluates the accuracy of this new product from FY-3B, 3C, and 3D by using the simultaneous collocated Global Precipitation Measurement(GPM)Microwave Imager(GMI) measurements as a reference. The results show that the mean biases(MBEs) of the BT between MWRI and GMI are generally less than 0.5 K and the root mean squares(RMSs) between them are less than1.5 K. The previous notable ascending and descending difference of the MWRI has disappeared. This indicates that the new MWRI recalibration procedure is very effective in removing potential errors associated with the emission of the hot-load reflector. Analysis of the dependence of MBE on the latitude and earth scene temperature shows that MBE decreases with decreasing latitude over ocean. Furthermore, MBE over ocean decreases linearly with increasing scene temperature for almost all channels, whereas this does not occur over land. A linear regression fitting is then used to modify MWRI, which can reduce the MBE over ocean to be within 0.2 K. The standard deviation of error of GMI, FY-3B, and FY-3D MWRI BT data derived by using the three-cornered hat method(TCH) shows that GMI has the best overall performance over ocean except at 10.65 GHz where its standard deviation of error is slightly larger than that of FY-3D. Over land, the standard deviation of error of FY-3D is the lowest at almost all channels except at 89V. MWRI onboard FY-3 series satellites would serve as an important passive microwave radiometer member of the constellation to monitor key surface and atmospheric properties. 展开更多
关键词 Microwave Radiometer Imager(MWRI) Global Precipitation measurement(GPM)Microwave Imager(GMI) brightness temperature(BT) the three-cornered hat method(TCH)
原文传递
Evaluating a satellite-based sea surface temperature by shipboard survey in the Northwest Indian Ocean
19
作者 YANG Guang HE Hailun +2 位作者 WANG Yuan HAN Xiqiu WANG Yejian 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2016年第11期52-58,共7页
A summer-time shipboard meteorological survey is described in the Northwest Indian Ocean. Shipboard observations are used to evaluate a satellite-based sea surface temperature(SST), and then find the main factors th... A summer-time shipboard meteorological survey is described in the Northwest Indian Ocean. Shipboard observations are used to evaluate a satellite-based sea surface temperature(SST), and then find the main factors that are highly correlated with errors. Two satellite data, the first is remote sensing product of a microwave, which is a Tropical Rainfall Measuring Mission Microwave Imager(TMI), and the second is merged data from the microwave and infrared satellite as well as drifter observations, which is Operational Sea Surface Temperature and Sea Ice Analysis(OSTIA). The results reveal that the daily mean SST of merged data has much lower bias and root mean square error as compared with that from microwave products. Therefore the results support the necessary of the merging infrared and drifter SST with a microwave satellite for improving the quality of the SST. Furthermore, the correlation coefficient between an SST error and meteorological parameters, which include a wind speed, an air temperature, a relative humidity, an air pressure, and a visibility. The results show that the wind speed has the largest correlation coefficient with the TMI SST error. However, the air temperature is the most important factor to the OSTIA SST error. Meanwhile,the relative humidity shows the high correlation with the SST error for the OSTIA product. 展开更多
关键词 shipboard survey sea surface temperature Northwest Indian Ocean Tropical Rainfall Measuring Mission Microwave Imager Operational Sea Surface Temperature and Sea Ice Analysis
下载PDF
Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
20
作者 Utkarsh Sharma Jin U.Kang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期910-912,共3页
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with... The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously. 展开更多
关键词 Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部