期刊文献+
共找到760,678篇文章
< 1 2 250 >
每页显示 20 50 100
Insight Into the Separation-of-Variable Methods for the Closed-Form Solutions of Free Vibration of Rectangular Thin Plates
1
作者 Yufeng Xing Ye Yuan Gen Li 《Computer Modeling in Engineering & Sciences》 SCIE EI 2025年第1期329-355,共27页
The separation-of-variable(SOV)methods,such as the improved SOV method,the variational SOV method,and the extended SOV method,have been proposed by the present authors and coworkers to obtain the closed-form analytica... The separation-of-variable(SOV)methods,such as the improved SOV method,the variational SOV method,and the extended SOV method,have been proposed by the present authors and coworkers to obtain the closed-form analytical solutions for free vibration and eigenbuckling of rectangular plates and circular cylindrical shells.By taking the free vibration of rectangular thin plates as an example,this work presents the theoretical framework of the SOV methods in an instructive way,and the bisection–based solution procedures for a group of nonlinear eigenvalue equations.Besides,the explicit equations of nodal lines of the SOV methods are presented,and the relations of nodal line patterns and frequency orders are investigated.It is concluded that the highly accurate SOV methods have the same accuracy for all frequencies,the mode shapes about repeated frequencies can also be precisely captured,and the SOV methods do not have the problem of missing roots as well. 展开更多
关键词 Separation-of-variable method Rayleigh quotient nodal line eigenvalue equation bisection method
下载PDF
Structural Modal Parameter Recognition and Related Damage Identification Methods under Environmental Excitations: A Review
2
作者 Chao Zhang Shang-Xi Lai Hua-Ping Wang 《Structural Durability & Health Monitoring》 EI 2025年第1期25-54,共30页
Modal parameters can accurately characterize the structural dynamic properties and assess the physical state of the structure.Therefore,it is particularly significant to identify the structural modal parameters accordi... Modal parameters can accurately characterize the structural dynamic properties and assess the physical state of the structure.Therefore,it is particularly significant to identify the structural modal parameters according to the monitoring data information in the structural health monitoring(SHM)system,so as to provide a scientific basis for structural damage identification and dynamic model modification.In view of this,this paper reviews methods for identifying structural modal parameters under environmental excitation and briefly describes how to identify structural damages based on the derived modal parameters.The paper primarily introduces data-driven modal parameter recognition methods(e.g.,time-domain,frequency-domain,and time-frequency-domain methods,etc.),briefly describes damage identification methods based on the variations of modal parameters(e.g.,natural frequency,modal shapes,and curvature modal shapes,etc.)and modal validation methods(e.g.,Stability Diagram and Modal Assurance Criterion,etc.).The current status of the application of artificial intelligence(AI)methods in the direction of modal parameter recognition and damage identification is further discussed.Based on the pre-vious analysis,the main development trends of structural modal parameter recognition and damage identification methods are given to provide scientific references for the optimized design and functional upgrading of SHM systems. 展开更多
关键词 Structural health monitoring data information modal parameters damage identification AI method
下载PDF
Effects of spatial heterogeneity on pseudo-static stability of coal mine overburden dump slope,using random limit equilibrium and random finite element methods:A comparative study
3
作者 Madhumita Mohanty Rajib Sarkar Sarat Kumar Das 《Earthquake Engineering and Engineering Vibration》 2025年第1期83-99,共17页
Sudden and unforeseen seismic failures of coal mine overburden(OB)dump slopes interrupt mining operations,cause loss of lives and delay the production of coal.Consideration of the spatial heterogeneity of OB dump mate... Sudden and unforeseen seismic failures of coal mine overburden(OB)dump slopes interrupt mining operations,cause loss of lives and delay the production of coal.Consideration of the spatial heterogeneity of OB dump materials is imperative for an adequate evaluation of the seismic stability of OB dump slopes.In this study,pseudo-static seismic stability analyses are carried out for an OB dump slope by considering the material parameters obtained from an insitu field investigation.Spatial heterogeneity is simulated through use of the random finite element method(RFEM)and the random limit equilibrium method(RLEM)and a comparative study is presented.Combinations of horizontal and vertical spatial correlation lengths were considered for simulating isotropic and anisotropic random fields within the OB dump slope.Seismic performances of the slope have been reported through the probability of failure and reliability index.It was observed that the RLEM approach overestimates failure probability(P_(f))by considering seismic stability with spatial heterogeneity.The P_(f)was observed to increase with an increase in the coefficient of variation of friction angle of the dump materials.Further,it was inferred that the RLEM approach may not be adequately applicable for assessing the seismic stability of an OB dump slope for a horizontal seismic coefficient that is more than or equal to 0.1. 展开更多
关键词 coal mine overburden dump slope random limit equilibrium method random finite element method seismic slope stability spatial heterogeneity
下载PDF
Hollow cerium nanoparticles synthesized by one-step method for multienzyme activity to reduce colitis in mice
4
作者 Lin Mi Kai Zhang +3 位作者 Jian-Xia Ma Jian-Feng Yao Yi-Li Tong Zhi-Jun Bao 《World Journal of Gastroenterology》 2025年第5期94-104,共11页
BACKGROUND Inflammatory bowel disease(IBD)is a common chronic intestinal inflammatory disease.High oxidative stress is a treatment target for IBD.Cerium oxide(CeO2)nanomaterials as nanozymes with antioxidant activity ... BACKGROUND Inflammatory bowel disease(IBD)is a common chronic intestinal inflammatory disease.High oxidative stress is a treatment target for IBD.Cerium oxide(CeO2)nanomaterials as nanozymes with antioxidant activity are potential drugs for the treatment of colitis.AIM To synthesize hollow cerium(H-CeO2)nanoparticles by one-step method and to validate the therapeutic efficacy of H-CeO2 in IBD.METHODS H-CeO2 was synthesized by one-step method and examined its characterization and nanoenzymatic activity.Subsequently,we constructed dextran sulfate so-dium(DSS)-induced colitis in mice to observe the effects of H-CeO2 on colonic inflammation.The effects of H-CeO2 on colon inflammation and reactive oxygen species(ROS)levels in IBD mice were detected by hematoxylin and eosin staining and dichlorofluorescein diacetate staining,respectively.Finally,the biological sa-fety of H-CeO2 on mice was evaluated by hematoxylin and eosin staining,blood routine,and blood biochemistry.RESULTS H-CeO2 nanoparticles prepared by the one-step method were uniform,monodi-sperse and hollow.H-CeO2 had a good ability to scavenge ROS,∙OH and∙OOH.H-CeO2 reduced DSS-induced decreases in body weight and colon length,colonic epithelial damage,inflammatory infiltration,and ROS accumulation.H-CeO2 administration reduced the disease activity index of DSS-induced animals from about 8 to 5.H-CeO2 had no significant effect on body weight,total platelet count,hemoglobin,white blood cell,and red blood cell counts in healthy mice.No significant damage to major organs was observed in healthy mice following H-CeO2 administration.CONCLUSION The one-step synthesis of H-CeO2 nanomaterials had good antioxidant activity,biosafety,and inhibited deve-lopment of DSS-induced IBD in mice by scavenging ROS. 展开更多
关键词 Inflammatory bowel disease Nanozymes Hollow cerium nanoparticles One-step method Cerium oxide biosafety
下载PDF
Retrospective comparative study of different surgical methods for gastric ulcer perforation:Efficacy and postoperative complications
5
作者 Yu-Fan Pang Liang Shu Cheng-Wei Xia 《World Journal of Gastrointestinal Surgery》 2025年第2期154-160,共7页
BACKGROUND Gastric ulcer perforation is a critical condition that can lead to significant morbidity and mortality if not promptly addressed.It is often the result of chronic peptic ulcer disease,which is characterized... BACKGROUND Gastric ulcer perforation is a critical condition that can lead to significant morbidity and mortality if not promptly addressed.It is often the result of chronic peptic ulcer disease,which is characterized by a breach in the gastric wall due to ulceration.Surgical intervention is essential for managing this life-threatening complication.However,the optimal surgical technique remains debatable among clinicians.Various methods have been employed,including simple closure,omental patch repair,and partial gastrectomy,each with distinct advantages and disadvantages.Understanding the comparative efficacy and postoperative outcomes of these techniques is crucial for improving patient care and surgical decision-making.This study addresses the need for a comprehensive analysis in this area.AIM To compare the efficacy and postoperative complications of different surgical methods for the treatment of gastric ulcer perforation.METHODS A retrospective analysis was conducted on 120 patients who underwent surgery for gastric ulcer perforation between September 2020 and June 2023.The patients were divided into three groups based on the surgical method:Simple closure,omental patch repair,and partial gastrectomy.The primary outcomes were the operative success rate and incidence of postoperative complications.Secondary outcomes included the length of hospital stay,recovery time,and long-term quality of life.RESULTS The operative success rates for simple closure,omental patch repair,and partial gastrectomy were 92.5%,95%,and 97.5%,respectively.Postoperative complications occurred in 20%,15%,and 17.5%of patients in each group,respectively.The partial gastrectomy group showed a significantly longer operative time(P<0.001)but the lowest rate of ulcer recurrence(2.5%,P<0.05).The omental patch repair group demonstrated the shortest hospital stay(mean 7.2 days,P<0.05)and fastest recovery time.CONCLUSION While all three surgical methods showed high success rates,omental patch repair demonstrated the best overall outcomes,with a balance of high efficacy,low complication rates,and shorter recovery time.However,the choice of the surgical method should be tailored to individual patient factors and the surgeon’s expertise. 展开更多
关键词 Gastric ulcer perforation Surgical methods Simple closure Omental patch repair Partial gastrectomy Postoperative complications
下载PDF
Electrochemiluminescence immunoassay method underestimates cortisol suppression in ulcerative colitis patients treated with oral prednisone 被引量:1
6
作者 Francesco Manguso Raffaele Bennato +3 位作者 Giovanni Lombardi Assunta Viola Elisabetta Riccio Livio Cipolletta 《World Journal of Gastroenterology》 SCIE CAS 2014年第31期10895-10899,共5页
AIM: To evaluate cortisolemia by using conventional electrochemiluminescence immunoassay (ECLIA) method compared to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in active ulcerative colitis (UC) pa... AIM: To evaluate cortisolemia by using conventional electrochemiluminescence immunoassay (ECLIA) method compared to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in active ulcerative colitis (UC) patients treated with oral prednisone (PD). 展开更多
关键词 CORTISOL immunoassay Liquid chromatography PREDNISONE Tandem mass spectrometry Ulcerative colitis
下载PDF
Precision medicine allergy immunoassay methods for assessing immunoglobulin E sensitization to aeroallergen molecules 被引量:2
7
作者 Florin-Dan Popescu Mariana Vieru 《World Journal of Methodology》 2018年第3期17-36,共20页
Molecular-based allergy diagnosis for the in vitro assessment of a patient immunoglobulin E(IgE) sensitization profile at the molecular level uses allergen molecules(also referred to as allergen components), which may... Molecular-based allergy diagnosis for the in vitro assessment of a patient immunoglobulin E(IgE) sensitization profile at the molecular level uses allergen molecules(also referred to as allergen components), which may be well-defined, highly purified, natural allergen components or recombinant allergens. Modern immunoassay methods used for the detection of specific Ig E against aeroallergen components are either singleplex(such as the fluorescence enzyme immunoassay with capsulated cellulose polymer solid-phase coupled allergens, the enzyme-enhanced chemiluminescence immunoassay and the reversed enzyme allergosorbent test, with liquid-phase allergens), multiparameter(such as the line blot immunoassay for defined partial allergen diagnostics with allergen components coating membrane strips) or multiplex(such as the microarraybased immunoassay on immuno solid-phase allergen chip, and the two new multiplex nanotechnology-based immunoassays: the patient-friendly allergen nanobead array, and the macroarray nanotechnology-based immunoassay used as a molecular allergy explorer). The precision medicine diagnostic work-up may be organized as an integrated "U-shape" approach, with a "top-down" approach(from symptoms to molecules) and a "bottomup" approach(from molecules to clinical implications), as needed in selected patients. The comprehensive and accurate Ig E sensitization molecular profiling, with identification of the relevant allergens, is indicated within the framework of a detailed patient's clinical history to distinguish genuine Ig E sensitization from sensitization due to cross-reactivity(especially in polysensitized patients), to assess unclear symptoms and unsatisfactory response to treatment, to reveal unexpected sensitizations, and to improve assessment of severity and risk aspects in some patients. Practical approaches, such as anamnesis molecular thinking, laboratory molecular thinking and postmolecular anamnesis, are sometimes applied. The component-resolved diagnosis of the specific IgE repertoire has a key impact on optimal decisions making for prophylactic and specific immunotherapeutic strategies tailored for the individual patient. 展开更多
关键词 Singleplex Multiplex IMMUNOGLOBULIN E SENSITIZATION AEROALLERGENS immunoassays
下载PDF
A New Immunoassay Method by Capillary Electrophoresis with Enhanced Chemiluminescence Detection
8
作者 JiaoNingWANG JiCunREN 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第6期793-796,共4页
This paper described a new immunoassay method by capillary electrophoresis with enhanced chemiluminescence (CL) detection system based on luminol-hydrogen peroxide reaction catalyzed by horseradish peroxides (HRP). Us... This paper described a new immunoassay method by capillary electrophoresis with enhanced chemiluminescence (CL) detection system based on luminol-hydrogen peroxide reaction catalyzed by horseradish peroxides (HRP). Using para-iodophenol as a CL enhancer, the detection limit of about 1×10-12 mol/L for HRP was achieved, which corresponded to 1.32×10-5 U/mL. In optimal conditions, the free HRP-labeled CA125 antibody (Ab*) and the bound enzyme-labeled complex (Ab*-Ag) were well separated by capillary electrophoresis within 4 min. The assay was successfully used to determine the contents of CA125 in human sera, which were associated with ovarian cancer, and the recoveries of the standard addition experiments were 96 to 109 %. 展开更多
关键词 Capillary electrophoresis chemiluminescence detection CA125 immunoassay.
下载PDF
Methodical and pre-analytical characteristics of a multiplex cancer biomarker immunoassay
9
作者 Natalie Hermann Katja Dre?en +2 位作者 Frank A Schildberg Christopher Jakobs Stefan Holdenrieder 《World Journal of Methodology》 2014年第4期219-231,共13页
AIM: To test the methodical and pre-analytical performance of a new multiplex cancer biomarker panel using magnetic beads. METHODS: The MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 comprises... AIM: To test the methodical and pre-analytical performance of a new multiplex cancer biomarker panel using magnetic beads. METHODS: The MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 comprises the tumor markers carcinoembryonic antigen, alpha-fetoprotein, total prostate-specific antigen, cancer antigen 15-3, cancer antigen 19-9, cancer antigen 125, cytokeratine 19-fragment, β-human chorionic gonadotropin, human epididymis protein 4, osteopontin, prolactin, the cell death and angiogenesis markers soluble Fas, soluble Fas-ligand, tumor necrosis factor related apoptosisinducing ligand, vascular endothelial growth factor andthe immunological markers interleukin-6(IL-6), IL-8, tumor necrosis factor-α, transforming growth factor α, fibroblast growth factor-2, macrophage migration inhibitory factor, leptin, hepatocyte growth factor, and stem cell factor. We determined intra- and inter-assay imprecision as well as dilution linearity using quality controls and serum pools. Furthermore, the stability of the 24 biomarkers examined in this panel was ascertained by testing the influence of different storage temperatures and time span before centrifugation.RESULTS: For all markers measured in the synthetic internal quality controls, the intra-assay imprecision ranged between 2.26% and 9.41%, while for 20 of 24 measured markers in the physiological serum pools, it ranged between 1.68% and 12.87%. The inter-assay imprecision ranged between 1.48%-17.12% for 23 biomarkers in synthetic, and between 4.59%-23.88% for 18 biomarkers in physiological quality controls. Here, single markers with very low concentration levels had increased imprecision rates. Dilution linearity was acceptable(70%-130% recovery) for 20 biomarkers. Regarding pre-analytical influencing factors, most markers were stable if blood centrifugation was delayed or if serum was stored for up to 24 h at 4 ℃ and 25 ℃ after centrifugation. Comparable results were obtained in serum and plasma for most markers. However, great changes were observed for single markers.CONCLUSION: MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 assay is a stable and precise method for detection of most biomarkers included in the kit. However, single markers have to be interpreted with care. 展开更多
关键词 Multiplex immunoassay Tumor marker CYTOKINES Cell death markers methodical evaluation
下载PDF
HOMOGENEOUS ENZYME IMMUNOASSAY OF SERUM AFP BY FLUORIMETRIC KINETIC METHOD
10
作者 Qing Ge LI Yi Bing ZHAO Jin Gou XU Xian Zhi HUANG Guo Zhen CHEN Department of Chemistry,Xiamen University,Xiamen,361005 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第4期353-354,共2页
The activity of the Ab-bound enzyme(HRP)changed after immunochemical reaction,and can be indicated by a sensitive fluorimetric kinetic method.The finding set the stage for developing sensitive homogeneous immunoassay.... The activity of the Ab-bound enzyme(HRP)changed after immunochemical reaction,and can be indicated by a sensitive fluorimetric kinetic method.The finding set the stage for developing sensitive homogeneous immunoassay.AFP was measured as an example. 展开更多
关键词 AFP HRP HVA HOMOGENEOUS ENZYME immunoassay OF SERUM AFP BY FLUORIMETRIC KINETIC method
下载PDF
A NOVEL POLYMER ENZYME LINKED IMMUNOASSAY METHOD AND ITS APPLICATIONS
11
作者 Feng LIU Feng Hua LIU +2 位作者 Ren Xi ZHUO Yan Zhuo DENG Yun E ZHEN (Department of Chemistry, Wuhan Univ., Wuhan 430072) 《Chinese Chemical Letters》 SCIE CAS CSCD 1994年第4期325-326,共2页
During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNI... During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNIP-Ab on the membrane increased over 30-fold when compared with the unconjugated Ab.Thus we used this characteristic to develop a novel immunoassay method-polymer enzyme linked immunoassay method: homogeneous antigen-antibody reaction and heterogeneous separation process. When applied for detection of human serum HBsAg, this immunoassay system can detect as little as 1 ng/ml of human serum HBsAg. 展开更多
关键词 ITS A NOVEL POLYMER ENZYME LINKED immunoassay method AND ITS APPLICATIONS
下载PDF
A Review on Sources,Extractions and Analysis Methods of a Sustainable Biomaterial:Tannins 被引量:2
12
作者 Antonio Pizzi Marie-Pierre Laborie Zeki Candan 《Journal of Renewable Materials》 EI CAS 2024年第3期397-425,共29页
Condensed and hydrolysable tannins are non-toxic natural polyphenols that are a commercial commodity industrialized for tanning hides to obtain leather and for a growing number of other industrial applications mainly ... Condensed and hydrolysable tannins are non-toxic natural polyphenols that are a commercial commodity industrialized for tanning hides to obtain leather and for a growing number of other industrial applications mainly to substitute petroleum-based products.They are a definite class of sustainable materials of the forestry industry.They have been in operation for hundreds of years to manufacture leather and now for a growing number of applications in a variety of other industries,such as wood adhesives,metal coating,pharmaceutical/medical applications and several others.This review presents the main sources,either already or potentially commercial of this forestry by-materials,their industrial and laboratory extraction systems,their systems of analysis with their advantages and drawbacks,be these methods so simple to even appear primitive but nonetheless of proven effectiveness,or very modern and instrumental.It constitutes a basic but essential summary of what is necessary to know of these sustainable materials.In doing so,the review highlights some of the main challenges that remain to be addressed to deliver the quality and economics of tannin supply necessary to fulfill the industrial production requirements for some materials-based uses. 展开更多
关键词 TANNINS FLAVONOIDS SOURCES extraction methods analysis methods
下载PDF
A QUENCHING FLUORESCENCE IMMUNOASSAY METHOD FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
13
作者 Feng Ji YAO Pei Hong LI Xiao Da YANG Bo XING Yun Xiang CI (Department of Chemistry,Peking University,100871) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第9期737-738,共2页
A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process ... A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%. 展开更多
关键词 FIA A QUENCHING FLUORESCENCE immunoassay method FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
下载PDF
Monitoring Passive Transfer of Immunity in Neonatal Calves by Measuring Levels of IgG in Blood Using Immunoassay Method and Refractometer Measures of Serum and Colostrum
14
作者 Osman A. Hameed Hussam Mustafa +1 位作者 Abdul Fatah M. Ahmed Mohamed Khidr Taha 《Open Journal of Veterinary Medicine》 2019年第12期194-201,共8页
IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hour... IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure. 展开更多
关键词 COLOSTRUM Passive IMMUNITY Immunoglobulin G (IgG) Failure of Transfer IMMUNITY (FTPI) Radial Immunodiffusion (RID) Turbidimetric immunoassay (TA) REFRACTOMETER (REF) BRIX REFRACTOMETER (Brix) Obione REFRACTOMETER (Obione) IGG Check Calf immunoassay High Quality COLOSTRUM Inadequate Transfer of Passive IMMUNITY (ITPI)
下载PDF
Drilling-based measuring method for the c-φ parameter of rock and its field application 被引量:4
15
作者 Bei Jiang Fenglin Ma +5 位作者 Qi Wang Hongke Gao Dahu Zhai Yusong Deng Chuanjie Xu Liangdi Yao 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第1期65-76,共12页
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R... The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters. 展开更多
关键词 Digital drilling Rock crushing zone c-u parameter Measurement method Field application
下载PDF
A comparison study on structure-function relationship of polysaccharides obtained from sea buckthorn berries using different methods:antioxidant and bile acid-binding capacity 被引量:8
16
作者 Qiaoyun Li Zuman Dou +5 位作者 Qingfei Duan Chun Chen Ruihai Liu Yueming Jiang Bao Yang Xiong Fu 《Food Science and Human Wellness》 SCIE CSCD 2024年第1期494-505,共12页
In this study,the structural characters,antioxidant activities and bile acid-binding ability of sea buckthorn polysaccharides(HRPs)obtained by the commonly used hot water(HRP-W),pressurized hot water(HRP-H),ultrasonic... In this study,the structural characters,antioxidant activities and bile acid-binding ability of sea buckthorn polysaccharides(HRPs)obtained by the commonly used hot water(HRP-W),pressurized hot water(HRP-H),ultrasonic(HRP-U),acid(HRP-C)and alkali(HRP-A)assisted extraction methods were investigated.The results demonstrated that extraction methods had significant effects on extraction yield,monosaccharide composition,molecular weight,particle size,triple-helical structure,and surface morphology of HRPs except for the major linkage bands.Thermogravimetric analysis showed that HRP-U with filamentous reticular microstructure exhibited better thermal stability.The HRP-A with the lowest molecular weight and highest arabinose content possessed the best antioxidant activities.Moreover,the rheological analysis indicated that HRPs with higher galacturonic acid content and molecular weight showed higher viscosity and stronger crosslinking network(HRP-C,HRP-W and HRP-U),which exhibited stronger bile acid binding capacity.The present findings provide scientific evidence in the preparation technology of sea buckthorn polysaccharides with good antioxidant and bile acid binding capacity which are related to the structure affected by the extraction methods. 展开更多
关键词 Sea buckthorn Extraction method STRUCTURE Rheological properties Antioxidant activity Bile acid binding capacity
下载PDF
Efficient slope reliability and sensitivity analysis using quantile-based first-order second-moment method 被引量:1
17
作者 Zhiyong Yang Chengchuan Yin +2 位作者 Xueyou Li Shuihua Jiang Dianqing Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第10期4192-4203,共12页
This paper introduces a novel approach for parameter sensitivity evaluation and efficient slope reliability analysis based on quantile-based first-order second-moment method(QFOSM).The core principles of the QFOSM are... This paper introduces a novel approach for parameter sensitivity evaluation and efficient slope reliability analysis based on quantile-based first-order second-moment method(QFOSM).The core principles of the QFOSM are elucidated geometrically from the perspective of expanding ellipsoids.Based on this geometric interpretation,the QFOSM is further extended to estimate sensitivity indices and assess the significance of various uncertain parameters involved in the slope system.The proposed method has the advantage of computational simplicity,akin to the conventional first-order second-moment method(FOSM),while providing estimation accuracy close to that of the first-order reliability method(FORM).Its performance is demonstrated with a numerical example and three slope examples.The results show that the proposed method can efficiently estimate the slope reliability and simultaneously evaluate the sensitivity of the uncertain parameters.The proposed method does not involve complex optimization or iteration required by the FORM.It can provide a valuable complement to the existing approximate reliability analysis methods,offering rapid sensitivity evaluation and slope reliability analysis. 展开更多
关键词 Slope reliability Sensitivity analysis QUANTILE First-order second-moment method(FOSM) First-order reliability method(FORM)
下载PDF
Material point method simulation of hydro-mechanical behaviour in twophase porous geomaterials: A state-of-the-art review 被引量:2
18
作者 Xiangcou Zheng Shuying Wang +1 位作者 Feng Yang Junsheng Yang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第6期2341-2350,共10页
The material point method(MPM)has been gaining increasing popularity as an appropriate approach to the solution of coupled hydro-mechanical problems involving large deformation.In this paper,we survey the current stat... The material point method(MPM)has been gaining increasing popularity as an appropriate approach to the solution of coupled hydro-mechanical problems involving large deformation.In this paper,we survey the current state-of-the-art in the MPM simulation of hydro-mechanical behaviour in two-phase porous geomaterials.The review covers the recent advances and developments in the MPM and their extensions to capture the coupled hydro-mechanical problems involving large deformations.The focus of this review is aiming at providing a clear picture of what has or has not been developed or implemented for simulating two-phase coupled large deformation problems,which will provide some direct reference for both practitioners and researchers. 展开更多
关键词 Coupled problems Hydro-mechanical behaviour Large deformation Material Point method(MPM)
下载PDF
Extended finite element-based cohesive zone method for modeling simultaneous hydraulic fracture height growth in layered reservoirs 被引量:1
19
作者 Lei Yang Baixi Chen 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第8期2960-2981,共22页
In this study,a fully coupled hydromechanical model within the extended finite element method(XFEM)-based cohesive zone method(CZM)is employed to investigate the simultaneous height growth behavior of multi-cluster hy... In this study,a fully coupled hydromechanical model within the extended finite element method(XFEM)-based cohesive zone method(CZM)is employed to investigate the simultaneous height growth behavior of multi-cluster hydraulic fractures in layered porous reservoirs with modulus contrast.The coupled hydromechanical model is first verified against an analytical solution and a laboratory experiment.Then,the fracture geometry(e.g.height,aperture,and area)and fluid pressure evolutions of multiple hydraulic fractures placed in a porous reservoir interbedded with alternating stiff and soft layers are investigated using the model.The stress and pore pressure distributions within the layered reservoir during fluid injection are also presented.The simulation results reveal that stress umbrellas are easily to form among multiple hydraulic fractures’tips when propagating in soft layers,which impedes the simultaneous height growth.It is also observed that the impediment effect of soft layer is much more significant in the fractures suppressed by the preferential growth of adjoining fractures.After that,the combined effect of in situ stress ratio and fracturing spacing on the multi-fracture height growth is presented,and the results elucidate the influence of in situ stress ratio on the height growth behavior depending on the fracture spacing.Finally,it is found that the inclusion of soft layers changes the aperture distribution of outmost and interior hydraulic fractures.The results obtained from this study may provide some insights on the understanding of hydraulic fracture height containment observed in filed. 展开更多
关键词 Hydraulic fracturing Layered reservoir Simultaneous height growth In situ stress Fracture spacing Extended finite element method(XFEM) Cohesive zone method(CZM)
下载PDF
Deciphering gastric inflammation-induced tumorigenesis through multi-omics data and AI methods 被引量:1
20
作者 Qian Zhang Mingran Yang +3 位作者 Peng Zhang Bowen Wu Xiaosen Wei Shao Li 《Cancer Biology & Medicine》 SCIE CAS CSCD 2024年第4期312-330,共19页
Gastric cancer(GC), the fifth most common cancer globally, remains the leading cause of cancer deaths worldwide. Inflammation-induced tumorigenesis is the predominant process in GC development;therefore, systematic re... Gastric cancer(GC), the fifth most common cancer globally, remains the leading cause of cancer deaths worldwide. Inflammation-induced tumorigenesis is the predominant process in GC development;therefore, systematic research in this area should improve understanding of the biological mechanisms that initiate GC development and promote cancer hallmarks. Here, we summarize biological knowledge regarding gastric inflammation-induced tumorigenesis, and characterize the multi-omics data and systems biology methods for investigating GC development. Of note, we highlight pioneering studies in multi-omics data and state-of-the-art network-based algorithms used for dissecting the features of gastric inflammation-induced tumorigenesis, and we propose translational applications in early GC warning biomarkers and precise treatment strategies. This review offers integrative insights for GC research, with the goal of paving the way to novel paradigms for GC precision oncology and prevention. 展开更多
关键词 Gastric cancer inflammation-induced tumorigenesis multi-omics artificial intelligence network-based methods
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部