期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Impact frequency variation of self-excited oscillation pulsed supercritical carbon dioxide jets
1
作者 SHEN Helian LIU Yong +3 位作者 WEI Jianping QIU Liming LI Haichao DENG Yujie 《Petroleum Exploration and Development》 SCIE 2023年第5期1261-1268,共8页
In order to obtain the impact frequency of resonant coal breaking by self-excited oscillation pulsed supercritical carbon dioxide(SC-CO_(2))jet,large eddy simulation was used to analyze the formation and development p... In order to obtain the impact frequency of resonant coal breaking by self-excited oscillation pulsed supercritical carbon dioxide(SC-CO_(2))jet,large eddy simulation was used to analyze the formation and development process of self-excited oscillation pulsed SC-CO_(2)jet,the variation of jet impact frequency in the nozzle and the free flow field,and the variation of jet impact frequency at different positions in the jet axis and under different cavity lengths.The test device of jet impact frequency was developed,and experiments were performed to verify the conclusions of the numerical simulations.The results show that the frequency of the self-excited oscillation pulsed SC-CO_(2)jet is different in the nozzle and the free flow field.In the nozzle,the frequency generated by the fluid disturbance is the same,and the jet frequency at the exit of the nozzle is consistent with that inside the nozzle.In the free flow field,due to the compressibility of CO_(2),the pressure,velocity and other parameters of SC-CO_(2)jets have obvious fluctuation patterns.This feature causes the impact frequency of the self-excited oscillation pulsed SC-CO_(2)jet to decrease gradually in the axis.Changing the cavity length allows the adjustment of the jet impact frequency in the free flow field by affecting the disturbance frequency of the self-excited oscillation pulsed SC-CO_(2)jet inside the nozzle. 展开更多
关键词 self-excited oscillation plused SC-CO_(2)jet resonant coal-breaking jet impact frequency cavity length
下载PDF
A novel inertia emulator to reduce the rate of change of frequency for power systems with solar PV and battery energy storage
2
作者 R Raja Nivedha Jai Govind Singh Weerakorn Ongsakul 《Clean Energy》 EI CSCD 2023年第4期873-884,共12页
Energy access,climate change and public health issues are some major drivers for the need for renewable sources.However,most renewable sources,excluding large hydro,have zero or negligible rotational inertia,which is ... Energy access,climate change and public health issues are some major drivers for the need for renewable sources.However,most renewable sources,excluding large hydro,have zero or negligible rotational inertia,which is critical to stabilizing the power system after contingency.Therefore,this paper proposes a droop-based inertia emulator to reduce the rate of change of frequency and frequency deviations.The robustness of the controller is analysed by applying various uncertainties and disturbances of power system components that were carried out using DIgSILENT PowerFactory simulations.The obtained results are compared with existing literature and the desired performance shows an improvement in the rate of change of frequency of 34.78%for an IEEE 6-bus system,24.32%for a 12-bus system and 18%for a 39-bus system. 展开更多
关键词 control of the rate of change of frequency low-inertia power system inertia emulator control rate of change of frequency impact of solar PV on frequency control impact of battery storage on inertia and frequency control
原文传递
上一页 1 下一页 到第