Background:Saccades are often observed on video head impulse tests(vHIT)in patients with Meniere's Disease(MD)and Vestibular Migraine(VM).However,their saccadic features are not fully described.Objective:This stud...Background:Saccades are often observed on video head impulse tests(vHIT)in patients with Meniere's Disease(MD)and Vestibular Migraine(VM).However,their saccadic features are not fully described.Objective:This study aims to identify the saccades characteristics of MD and VM.Methods:75 VM patients and 103 definite unilateral MD patients were enrolled in this study.First raw saccades were exported and analyzed.The VM patients were divided into left and right based on their ears,while the MD patients were separated into affected and unaffected subgroups based on their audiograms and symptoms.Results:The MD patients have more saccades on the affected side(85%vs.69%),and saccade velocity is more consistent than the contralateral side(shown by the coefficient of variation).The saccades occurrence rates on both sides are similar in VM(77%vs.76%),as are other saccadic parameters.The MD patients have more significant inter-aural differences than the VM patients,manifested in higher velocity(p-value 0.000),earlier arriving(p-value 0.010),and more time-domain gathered(p-value 0.003)on the affected side.Conclusions:Bilateral saccades are commonly observed in MD and VM.In contrast to MD,saccades on VM are subtle,scattered,and late-arrived.Furthermore,the MD patients showed inconsistent saccadic distribution with more velocity-uniform saccades on the affected side.展开更多
Objective:Saccades accompanied by normal gain in video head impulse tests(vHIT)are often observed in patients with vestibular migraine(VM).However,they are not considered as an independent indicator,reducing their uti...Objective:Saccades accompanied by normal gain in video head impulse tests(vHIT)are often observed in patients with vestibular migraine(VM).However,they are not considered as an independent indicator,reducing their utility in diagnosing VM.To better understand clinical features of VM,it is necessary to understand raw saccades data.Methods:Fourteen patients with confirmed VM,45 patients with probable VM(p-VM)and 14 agematched healthy volunteers were included in this study.Clinical findings related to spontaneous nystagmus(SN),positional nystagmus(PN),head-shaking nystagmus(HSN),caloric test and vHIT were recorded.Raw saccades data were exported and numbered by their sequences,and their features analyzed.Results:VM patients showed no SN,PN or HSN,and less than half of them showed unilateral weakness(UW)on caloric test.The first saccades from lateral semicircular canal stimulation were the most predominant for both left and right sides.Neither velocity nor time parameters were significantly different when compared between the two sides.Most VM patients(86%)exhibited small saccades,around 35%of the head peak velocity,with a latency of 200e400 ms.Characteristics of saccades were similar in patients with p-VM.Only four normal subjects showed saccades,all unilateral and seemingly random.Conclusions:Small saccades involving bilateral semicircular canals with a scattered distribution pattern are common in patients with VM and p-VM.展开更多
Objective To compare the performances among three different systems for video head impulse test(vHIT),and to identify an optimal target angle for precisely evaluating the function of vertical semicircular canals in vH...Objective To compare the performances among three different systems for video head impulse test(vHIT),and to identify an optimal target angle for precisely evaluating the function of vertical semicircular canals in vHIT.Methods A two-center prospective study was done.Participants were sit 1.2 m away from the wall in a noise-proved room that dedicated for vHIT experiments.During the comparison experiments,similar settings were ensured in both hospitals,with the same distance to wall and angle of staring.For each equipment,the procedures followed the developers’recommendations.The same examiner performed the comparison between two systems in one location.For the eye-position projects,targets were placed on the wall sequentially at the pre-marked lines for different angles.For the comparison projects,9 and 13 participants were recruited,respectively.Any participant with otologic or vestibular disorders was excluded.A total of 26 healthy participants were recruited in the eye-position experiments,16 of which were further involved in inter-examiner tests.Results Our evaluations of three different systems showed that a new vHIT system,VertiGoggles®ZT-VNG-I(VG)performed as good as the long-tested Otometrics®ICS impulse(Oto)and EyeSeeCam®(ESC).During the comparison,we validated 25-degree,instead of right ahead at 0 degree,is a better place to set the targets when torsion was applied at vertical semicircular canal planes.Conclusion The new VG system is good for clinical practices.Furthermore,we proposed a new protocol to set the targets 25 degrees from right ahead after tilting head 45 degrees to evaluate vertical canals during vHIT.展开更多
Objective:Vestibular dysfunction is a known risk of cochlear implantation(CI).However,the utility of the physical exam to screen CI candidates for vestibular dysfunction is not well-studied.The objective of this study...Objective:Vestibular dysfunction is a known risk of cochlear implantation(CI).However,the utility of the physical exam to screen CI candidates for vestibular dysfunction is not well-studied.The objective of this study is to evaluate the preoperative role of the clinical head impulse test(cHIT)in subjects undergoing CI surgery evaluation.Study Design Setting,and Subjects:We conducted a retrospective review of 64 adult CI candidacy cases between 2017 and 2020 at a tertiary health care center.Methods:All patients underwent audiometric testing and evaluation by the senior author.Patients with an abnormal catch-up saccade contralateral to their worse hearing ear during cHIT were referred for formal vestibular testing.Outcomes included clinical and formal vestibular results,operated ear with regard to audiometric and vestibular results,and postoperative vertigo.Results:Among all CI candidates,44%(n=28)reported preoperative disequilibrium symptoms.Overall,62%(n=40)of the cHITs were normal,33%(n=21)were abnormal,and 5%(n=3)were inconclusive.There was one patient who presented with a false positive cHIT.Among the patients who endorsed disequilibrium,43%had a positive preoperative cHIT.Fourteen percent of the subjects(n=9)without disequilibrium had an abnormal cHIT.In this cohort,bilateral vestibular impairment(71%)was more common than unilateral vestibular impairment(29%).In 3%of the cases(n=2),surgical management was revisited or altered due to cHIT findings.Conclusion:There is a high prevalence of vestibular hypofunction in the CI candidate population.Self-reported assessments of vestibular function are often not congruent with cHIT results.Clinicians should consider incorporating cHITs as part of the preoperative physical exam to potentially avoid bilateral vestibular dysfunction in a minority of patients.展开更多
In recent years,more than 6 million room temperature vulcanized(RTV)silicone rubber coated cap and pin insulators with high mechanical ratings were used in ultra-high voltage transmission lines in China to improve pol...In recent years,more than 6 million room temperature vulcanized(RTV)silicone rubber coated cap and pin insulators with high mechanical ratings were used in ultra-high voltage transmission lines in China to improve pollution performance.However,the unexpected puncture phenomena of RTV coated insulators were exposed during steep-front impulse voltage tests;for instance,the steep-front impulse voltage test pass rate decreased to less than 50% for 550 kN glass insulators with RTV coatings.The steep-front impulse voltage test is the most effective method used to check the insulation quality of cap and pin insulators・This unexpected phenomenon once caused serious concerns to power utilities.In this paper,several possible factors that affect the puncture of insulators were analyzed.Then,the extent of the decline in the breakdown of the 550 kN glass cap and pin insulators with and without RTV coatings were studied.The initial puncture location was then found,and the developmental process of the arc on the insulator surface in steep-front impulse voltage tests was observed with an ultra-high-speed intensified charge coupled device camera.Lastly,a breakdown mechanism is proposed.The puncture phenomena of a RTV coated insulator in a steep-front impulse voltage test is essentially an electrical breakdown of the internal insulation・The RTV coating induces the close adherence of the arc to the surface of the insulator.Such closeness changes the arc development path on the insulator surface and facilitates easy breakdown in the shed weak part.All these factors result in a significant increase in the breakdown probability of RTV coated insulators in steepfront impulse voltage tests.展开更多
基金supported by grants from National Key Research and Development Program of China-part3(2020YFC2005203)Capital's Funds for Health Improvement and Research(No.2022-1-2023).
文摘Background:Saccades are often observed on video head impulse tests(vHIT)in patients with Meniere's Disease(MD)and Vestibular Migraine(VM).However,their saccadic features are not fully described.Objective:This study aims to identify the saccades characteristics of MD and VM.Methods:75 VM patients and 103 definite unilateral MD patients were enrolled in this study.First raw saccades were exported and analyzed.The VM patients were divided into left and right based on their ears,while the MD patients were separated into affected and unaffected subgroups based on their audiograms and symptoms.Results:The MD patients have more saccades on the affected side(85%vs.69%),and saccade velocity is more consistent than the contralateral side(shown by the coefficient of variation).The saccades occurrence rates on both sides are similar in VM(77%vs.76%),as are other saccadic parameters.The MD patients have more significant inter-aural differences than the VM patients,manifested in higher velocity(p-value 0.000),earlier arriving(p-value 0.010),and more time-domain gathered(p-value 0.003)on the affected side.Conclusions:Bilateral saccades are commonly observed in MD and VM.In contrast to MD,saccades on VM are subtle,scattered,and late-arrived.Furthermore,the MD patients showed inconsistent saccadic distribution with more velocity-uniform saccades on the affected side.
文摘Objective:Saccades accompanied by normal gain in video head impulse tests(vHIT)are often observed in patients with vestibular migraine(VM).However,they are not considered as an independent indicator,reducing their utility in diagnosing VM.To better understand clinical features of VM,it is necessary to understand raw saccades data.Methods:Fourteen patients with confirmed VM,45 patients with probable VM(p-VM)and 14 agematched healthy volunteers were included in this study.Clinical findings related to spontaneous nystagmus(SN),positional nystagmus(PN),head-shaking nystagmus(HSN),caloric test and vHIT were recorded.Raw saccades data were exported and numbered by their sequences,and their features analyzed.Results:VM patients showed no SN,PN or HSN,and less than half of them showed unilateral weakness(UW)on caloric test.The first saccades from lateral semicircular canal stimulation were the most predominant for both left and right sides.Neither velocity nor time parameters were significantly different when compared between the two sides.Most VM patients(86%)exhibited small saccades,around 35%of the head peak velocity,with a latency of 200e400 ms.Characteristics of saccades were similar in patients with p-VM.Only four normal subjects showed saccades,all unilateral and seemingly random.Conclusions:Small saccades involving bilateral semicircular canals with a scattered distribution pattern are common in patients with VM and p-VM.
基金supported by grants from the National Science Foundation for Outstanding Young People(No.81922018)the Transformation and Industrialization of Scientific and Technological Achievements in Shanghai(No.18441904000)+3 种基金the National Natural Science Foundation of China(No.81771011)the National Natural Science Foundation of China Young Investigator Program(No.81800907)the Development Fund for Shanghai Talents(No.2017046)the Excellent Personnel Training Plan for the Shanghai Health System(No.2017Q003).
文摘Objective To compare the performances among three different systems for video head impulse test(vHIT),and to identify an optimal target angle for precisely evaluating the function of vertical semicircular canals in vHIT.Methods A two-center prospective study was done.Participants were sit 1.2 m away from the wall in a noise-proved room that dedicated for vHIT experiments.During the comparison experiments,similar settings were ensured in both hospitals,with the same distance to wall and angle of staring.For each equipment,the procedures followed the developers’recommendations.The same examiner performed the comparison between two systems in one location.For the eye-position projects,targets were placed on the wall sequentially at the pre-marked lines for different angles.For the comparison projects,9 and 13 participants were recruited,respectively.Any participant with otologic or vestibular disorders was excluded.A total of 26 healthy participants were recruited in the eye-position experiments,16 of which were further involved in inter-examiner tests.Results Our evaluations of three different systems showed that a new vHIT system,VertiGoggles®ZT-VNG-I(VG)performed as good as the long-tested Otometrics®ICS impulse(Oto)and EyeSeeCam®(ESC).During the comparison,we validated 25-degree,instead of right ahead at 0 degree,is a better place to set the targets when torsion was applied at vertical semicircular canal planes.Conclusion The new VG system is good for clinical practices.Furthermore,we proposed a new protocol to set the targets 25 degrees from right ahead after tilting head 45 degrees to evaluate vertical canals during vHIT.
文摘Objective:Vestibular dysfunction is a known risk of cochlear implantation(CI).However,the utility of the physical exam to screen CI candidates for vestibular dysfunction is not well-studied.The objective of this study is to evaluate the preoperative role of the clinical head impulse test(cHIT)in subjects undergoing CI surgery evaluation.Study Design Setting,and Subjects:We conducted a retrospective review of 64 adult CI candidacy cases between 2017 and 2020 at a tertiary health care center.Methods:All patients underwent audiometric testing and evaluation by the senior author.Patients with an abnormal catch-up saccade contralateral to their worse hearing ear during cHIT were referred for formal vestibular testing.Outcomes included clinical and formal vestibular results,operated ear with regard to audiometric and vestibular results,and postoperative vertigo.Results:Among all CI candidates,44%(n=28)reported preoperative disequilibrium symptoms.Overall,62%(n=40)of the cHITs were normal,33%(n=21)were abnormal,and 5%(n=3)were inconclusive.There was one patient who presented with a false positive cHIT.Among the patients who endorsed disequilibrium,43%had a positive preoperative cHIT.Fourteen percent of the subjects(n=9)without disequilibrium had an abnormal cHIT.In this cohort,bilateral vestibular impairment(71%)was more common than unilateral vestibular impairment(29%).In 3%of the cases(n=2),surgical management was revisited or altered due to cHIT findings.Conclusion:There is a high prevalence of vestibular hypofunction in the CI candidate population.Self-reported assessments of vestibular function are often not congruent with cHIT results.Clinicians should consider incorporating cHITs as part of the preoperative physical exam to potentially avoid bilateral vestibular dysfunction in a minority of patients.
基金supported by the National Natural Science Foundation of China(51577099).
文摘In recent years,more than 6 million room temperature vulcanized(RTV)silicone rubber coated cap and pin insulators with high mechanical ratings were used in ultra-high voltage transmission lines in China to improve pollution performance.However,the unexpected puncture phenomena of RTV coated insulators were exposed during steep-front impulse voltage tests;for instance,the steep-front impulse voltage test pass rate decreased to less than 50% for 550 kN glass insulators with RTV coatings.The steep-front impulse voltage test is the most effective method used to check the insulation quality of cap and pin insulators・This unexpected phenomenon once caused serious concerns to power utilities.In this paper,several possible factors that affect the puncture of insulators were analyzed.Then,the extent of the decline in the breakdown of the 550 kN glass cap and pin insulators with and without RTV coatings were studied.The initial puncture location was then found,and the developmental process of the arc on the insulator surface in steep-front impulse voltage tests was observed with an ultra-high-speed intensified charge coupled device camera.Lastly,a breakdown mechanism is proposed.The puncture phenomena of a RTV coated insulator in a steep-front impulse voltage test is essentially an electrical breakdown of the internal insulation・The RTV coating induces the close adherence of the arc to the surface of the insulator.Such closeness changes the arc development path on the insulator surface and facilitates easy breakdown in the shed weak part.All these factors result in a significant increase in the breakdown probability of RTV coated insulators in steepfront impulse voltage tests.