期刊文献+
共找到5,782篇文章
< 1 2 250 >
每页显示 20 50 100
Enhancing Energy Efficiency with a Dynamic Trust Measurement Scheme in Power Distribution Network
1
作者 Yilei Wang Xin Sun +4 位作者 Guiping Zheng Ahmar Rashid Sami Ullah Hisham Alasmary Muhammad Waqas 《Computers, Materials & Continua》 SCIE EI 2024年第3期3909-3927,共19页
The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the e... The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the edge convergence layer and the end sensing layer,with the former using intelligent fusion terminals for real-time data collection and processing.However,the influx of multiple low-voltage in the smart grid raises higher demands for the performance,energy efficiency,and response speed of the substation fusion terminals.Simultaneously,it brings significant security risks to the entire distribution substation,posing a major challenge to the smart grid.In response to these challenges,a proposed dynamic and energy-efficient trust measurement scheme for smart grids aims to address these issues.The scheme begins by establishing a hierarchical trust measurement model,elucidating the trust relationships among smart IoT terminals.It then incorporates multidimensional measurement factors,encompassing static environmental factors,dynamic behaviors,and energy states.This comprehensive approach reduces the impact of subjective factors on trust measurements.Additionally,the scheme incorporates a detection process designed for identifying malicious low-voltage end sensing units,ensuring the prompt identification and elimination of any malicious terminals.This,in turn,enhances the security and reliability of the smart grid environment.The effectiveness of the proposed scheme in pinpointing malicious nodes has been demonstrated through simulation experiments.Notably,the scheme outperforms established trust metric models in terms of energy efficiency,showcasing its significant contribution to the field. 展开更多
关键词 IIoT trusted measure energy efficient
下载PDF
Energy-Efficient Approaches for a Machine Tool Building in a University through Field Measurement and Energy Modelling
2
作者 Kusnandar Win-Jet Luo +2 位作者 Indra Permana Fu-Jen Wang Gantulga Bayarkhuu 《Energy Engineering》 EI 2023年第6期1387-1399,共13页
The heating,ventilating,and air conditioning(HVAC)system consumes nearly 50%of the building’s energy,especially in Taiwan with a hot and humid climate.Due to the challenges in obtaining energy sources and the negativ... The heating,ventilating,and air conditioning(HVAC)system consumes nearly 50%of the building’s energy,especially in Taiwan with a hot and humid climate.Due to the challenges in obtaining energy sources and the negative impacts of excessive energy use on the environment,it is essential to employ an energy-efficient HVAC system.This study conducted the machine tools building in a university.The field measurement was carried out,and the data were used to conduct energymodelling with EnergyPlus(EP)in order to discover some improvements in energy-efficient design.The validation between fieldmeasurement and energymodelling was performed,and the error rate was less than 10%.The following strategies were proposed in this study based on several energy-efficient approaches,including room temperature settings,chilled water supply temperature settings,chiller coefficient of performance(COP),shading,and building location.Energy-efficient approaches have been evaluated and could reduce energy consumption annually.The results reveal that the proposed energy-efficient approaches of room temperature settings(3.8%),chilled water supply temperature settings(2.1%),chiller COP(5.9%),using shading(9.1%),and building location(3.0%),respectively,could reduce energy consumption.The analysis discovered that using a well-performing HVAC system and building shading were effective in lowering the amount of energy used,and the energy modelling method could be an effective and satisfactory tool in determining potential energy savings. 展开更多
关键词 energy-EFFICIENT energy modelling field measurement BEMS machine tools building
下载PDF
A Moored Underwater Energy Conservation System for Profiling Measurement 被引量:5
3
作者 龚德俊 陈永华 +2 位作者 李思忍 徐永平 姜静波 《China Ocean Engineering》 SCIE EI 2007年第3期541-548,共8页
There is a need to obtain the hydrologic data including ocean current, wave, temperature and so on in the South China Sea. A new profiling instrument which does not suffer from the damage due to nature forces or incid... There is a need to obtain the hydrologic data including ocean current, wave, temperature and so on in the South China Sea. A new profiling instrument which does not suffer from the damage due to nature forces or incidents caused by passing ships, is under development to acquire data from this area. This device is based on a taut single point mid-water mooring system. It incorporates a small, instrumented vertically profiling float attached via an electromechanical cable to a winch integral with the main subsurface flotation. On a pre-set schedule, the instrument float with sensors is winched up to the surface if there is no ship passing by, which is defined by an on-board miniature sonar. And it can be. inunediately winched down to a certain depth if the sonar sensor finds something is coming. Since, because of logistics, the area can only be visited once for a long time and a minimum of 10 times per day profiles are desired, energy demands are severe. To respond to these concerns, the system has been designed to conserve a substantial portion of the potential energy lost during the ascent phase of each profile and subsequently use this energy to pull the instrument down. Compared with the previous single-point layered measuring mode, it is advanced and economical. At last the paper introduces the test in the South China Sea. 展开更多
关键词 energy conservation profiling measurement hydrologic data moored underwater system security and continuity
下载PDF
Rough law energy and measurement of ■-decomposition rough law 被引量:2
4
作者 Shunliang Huang Huafeng Yang Kaiquan Shi 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2010年第1期62-66,共5页
By employing function one-direction S-rough sets and rough law generation method based on function S-rough sets, ^-f-decomposition law and ^-F-decomposition rough law are proposed, and the measurement of rough law var... By employing function one-direction S-rough sets and rough law generation method based on function S-rough sets, ^-f-decomposition law and ^-F-decomposition rough law are proposed, and the measurement of rough law variation in the process of rough law ^-F-decomposition is researched. The concepts of law energy and attdbute ^-f-interference degree are presented, which make the variation of rough law become measurable. ^-f-decomposition law energy characteristic theorem, ^-f- decomposition law energy inequality theorem, ^-F-decomposition rough law energy characteristic theorem, and ^-f-decomposition law energy mean value theorem are presented. 展开更多
关键词 function one-direction S-rough sets measurement ^-f-decomposition law F-decomposition rough law attribute ^-f-interference degree rough law energy.
下载PDF
Measurement of Secondary Electron Energy Spectra of Polymethyl Methacrylate 被引量:1
5
作者 Ming Weng Wan Liu +2 位作者 Ming Yin Fang Wang Meng Cao 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第4期108-112,共5页
We report on a novel and convenient method of measuring secondary electron spectra for insulators in a secondary electron yield measurement system with a planar grid analyzer configuration and a metal mesh probe. In t... We report on a novel and convenient method of measuring secondary electron spectra for insulators in a secondary electron yield measurement system with a planar grid analyzer configuration and a metal mesh probe. In this measurement, the planar grid is negatively biased to force some emitted secondary electrons to return to the sample surface and to neutralize charges accumulated on the sample during the previous beam irradiation. The surface potential of the sample is then measured by use of a metal mesh probe. The grid bias for neutralization corresponding to the zero surface potential is determined based on the linear relationship between the surface potential and the grid bias. Once the surface potential equals zero, the secondary electron spectra of polymethyl methacrylate(PMMA) are studied experimentally by measuring the -curve and then fitting it to Everhart's formula. The measurement results show that the peak energy and the full width at half maximum of the spectra are 4.26 eV and 14.06 eV, respectively. 展开更多
关键词 SE In measurement of Secondary Electron energy Spectra of Polymethyl Methacrylate
下载PDF
Simultaneous Measurements of Rainfall Intensity, Low Energy Neutrons and Gamma Radiation in Sao Jose Dos Campos, SP, Brazil 被引量:1
6
作者 Marcelo Pego Gomes Inacio Malmonge Martin +4 位作者 Mauro Angelo Alves Bogos Nubar Sismanoglu Marco Antonio S. Ferro Marcos Pinto Flavio Antonio 《Journal of Environmental Science and Engineering(B)》 2013年第11期643-647,共5页
The article aims to study the possible correlation between the presence and intensity of rainfall X- and T-radiation and low energy neutrons at one specific location in S[io Jos6 dos Campos, SP, Brazil. Monitoring of ... The article aims to study the possible correlation between the presence and intensity of rainfall X- and T-radiation and low energy neutrons at one specific location in S[io Jos6 dos Campos, SP, Brazil. Monitoring of these parameters was carried out from end February to half of June 2013 just in Physics Department of ITA (Technological Institute of Aeronautics). By correlating the data of measurements of intensity of X and ),-radiations with the rainfall it has been found that this meteorological parameter had a significant influence on the background of these radiation profile. A possible reason for this fact is associated with the presence of radon gas in the environment that is dragged to the surface during the occurrences of local rainfall. In relation neutrons, it was possible to note that the rainfall has small influence on this parameter measures. 展开更多
关键词 X- and y-radiation low energy neutron rainfalls experimental measurements.
下载PDF
Direct Measurements of the Electron Energy Flux versus Electron Temperature Gradient in Tokamak Discharges
7
作者 K.W.Gentle M.E.Austin P.E.Phillips 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第1期2130-2134,共5页
Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradien... Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradient effects with moderate stiffness. By analyzingperiodic perturbations to an equilibrium, one canmeasure the variations in electron energy flux andelectron temperature gradient over the perturbation cycle, obtaining the flux as a function ofgradient over the range of parameters generated by the perturbation. Although time-dependenttransport analysis is very sensitive to noise in the input data, averaging over many cycles of aperiodic perturbation can provide data of sufficient quality. The analyses presented here are basedon the ECE temperature data with high spatial and temporal resolution and full profile coverage onDIII-D for sawteeth and modulated ECH heating. 展开更多
关键词 tokamak discharges electron energy flux electron temperature gradient direct measurements
下载PDF
Effect of building energy efficiency standards on carbon emission efficiency in commercial buildings
8
作者 Xia Wang Qi Ye +1 位作者 Yan Du Mao Zhou 《Chinese Journal of Population,Resources and Environment》 2024年第3期250-257,共8页
The building sector plays a crucial role in the worldwide shift toward achieving net-zero emissions.Building energy efficiency standards(BEESs)are highly effective policies for reducing carbon emissions.Therefore,expl... The building sector plays a crucial role in the worldwide shift toward achieving net-zero emissions.Building energy efficiency standards(BEESs)are highly effective policies for reducing carbon emissions.Therefore,exploring the provincial variations in carbon emission efficiency(CEE)in the building sector and identifying the effect of BEESs on CEE is crucial.This study focuses on commercial buildings in China and applies a difference in differences model to evaluate the impact of BEESs on the CEE of commercial buildings.The slacks-based measure–data envelopment analysis model is employed to assess the CEE of commercial buildings in 30 Chinese provinces from 2000 to 2019.Furthermore,heterogeneous tests are used to explore how climate characteristics and economic conditions affect the efficiency of BEESs.The results indicate that BEESs positively influence the CEE of commercial buildings.Specifically,a 1%increase in the intensity of BEESs causes a 0.1484%increase in the CEE of commercial buildings.Moreover,the impact of BEESs is particularly pronounced in the southern and western provinces.This study provides valuable scientific evidence for governments to enhance BEESs implementation. 展开更多
关键词 Commercial buildings Carbon emissions efficiency Building energy efficiency standards Slack-based measure–data development analysis Difference in differences
下载PDF
Quantum Nondemolition Measurement of the Collective Motional Energy of Two Trapped Ions
9
作者 ZHENGShi-Biao 《Communications in Theoretical Physics》 SCIE CAS CSCD 2002年第4期479-482,共4页
We propose a quantum nondemolition measurement of the collective motional energy of two trapped ions for the first time.It is based on the excitation of the two ions by two lasers with appropriate frequencies and ampl... We propose a quantum nondemolition measurement of the collective motional energy of two trapped ions for the first time.It is based on the excitation of the two ions by two lasers with appropriate frequencies and amplitudes.The scheme also provides a new possibility of preparing vibrational Fock states and laser cooling. 展开更多
关键词 quantum nondemolition measurement collective motional energy trapped ions
下载PDF
Facing a Problem of Electrical Energy Quality in Ship Networks-measurements, Estimation, Control 被引量:2
10
作者 TomaszTarasiuk JanuszMindykowski XiaoyanXu 《上海海运学院学报》 北大核心 2003年第3期193-199,共7页
In this paper, electrical energy quality and its indices in ship electric networks are introduced, especially the meaning of electrical energy quality terms in voltage and active and reactive power distribution indice... In this paper, electrical energy quality and its indices in ship electric networks are introduced, especially the meaning of electrical energy quality terms in voltage and active and reactive power distribution indices. Then methods of measurement of marine electrical energy indices are introduced in details and a microprocessor measurement-diagnosis system with the function of measurement and control is designed. Afterwards, estimation and control of electrical power quality of marine electrical power networks are introduced. And finally, according to the existing method of measurement and control of electrical power quality in ship power networks, the improvement of relative method is proposed. 展开更多
关键词 船舶 电子网络 电能质量 测量 估计 控制 电气设备
下载PDF
4-27 Energy Loss Measurement of the Low Energy He2+ IonsPenetrating the Hydrogen Plasma Target
11
作者 Cheng Rui Zhao Yongtao +7 位作者 Deng Jiachuan Wang Yuyu Zhou Xianming Peng Haibo Lei Yu Liu Shidong Ma Lidong Xiao Jiahao 《IMP & HIRFL Annual Report》 2014年第1期204-204,共1页
The interaction process of ions and plasmas is an important topic in Ion-Beam-Driven High Energy DensityPhysics and Inertial Confinement Fusion research. Due to the strong non-linear effects and the special importance... The interaction process of ions and plasmas is an important topic in Ion-Beam-Driven High Energy DensityPhysics and Inertial Confinement Fusion research. Due to the strong non-linear effects and the special importancein ICF research, more and more emphasis has been given to the investigations for ion beam in low energy rangeand/or for plasma with high intensity[1;2]. Here, we address the newly measured results of the energy loss by slowions penetrating the fully ionized hydrogen plasma target. 展开更多
关键词 energy measurement IonsPenetrating
下载PDF
Experimental Measurements of Neutron Yields and Neutron Emission Rates in Intermediate Energy Heavy, Ion Reactions
12
作者 Li Guisheng Zhang Tianmei Li Zongwei and Su Youwu 《IMP & HIRFL Annual Report》 1996年第1期118-118,共1页
ExperimentalMeasurementsofNeutronYieldsandNeutronEmissionRatesinIntermediateEnergyHeavy,IonReactions¥LiGuish... ExperimentalMeasurementsofNeutronYieldsandNeutronEmissionRatesinIntermediateEnergyHeavy,IonReactions¥LiGuisheng;ZhangTianmei;... 展开更多
关键词 INTERMEDIATE energy Experimental HEAVY EMISSION ION measurements NEUTRON Rates REACTIONS
下载PDF
Improvement of Beam Energy Measurement System for BES-III
13
作者 Jianyong Zhang Xiao Cai +4 位作者 Xiaohu Mochizuki Muchnoi Nickolai Achasov Mikhail Elena Abakumova Harris Fred 《World Journal of Nuclear Science and Technology》 2016年第4期261-283,共23页
The beam energy measurement system is significant and profit for both BES-III detector and BEPC-II accelerator. The detection of the high energy scattering photons is realized by virtue of the Compton backscattering p... The beam energy measurement system is significant and profit for both BES-III detector and BEPC-II accelerator. The detection of the high energy scattering photons is realized by virtue of the Compton backscattering principle. Many advanced techniques and precise instruments are employed to acquire the highly accurate measurement of positron/electron beam energy. During five years’ running period, in order to satisfy the requirement of data taking and enhance the capacity of measurement itself, the upgradation of system is continued, which involves the components reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the usage of electric cooling system for high purity germanium detector, and the refinement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and effective measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III. 展开更多
关键词 LASER HPGe Detector Beam energy measurement
下载PDF
Time Series-, Time-Frequency- and Spectral Analyses of Sensor Measurements in an Offshore Wave Energy Converter Based on Linear Generator Technology
14
作者 Erland Stromstedt Andrej Savin +1 位作者 Olle Svensson Mats Leijon 《Energy and Power Engineering》 2013年第1期70-91,共22页
Inside the second experimental wave energy converter (WEC) launched at the Lysekil research site on the Swedish west coast in March 2009 a number of sensor systems were installed for measuring the mechanical performan... Inside the second experimental wave energy converter (WEC) launched at the Lysekil research site on the Swedish west coast in March 2009 a number of sensor systems were installed for measuring the mechanical performance of the WEC and its mechanical subsystems. One of the measurement systems was a set-up of 7 laser triangulation sensors for measuring relative displacement of the piston rod mechanical lead-through transmission in the direct drive. Two measurement periods, separated by 2.5 month, are presented in this paper. One measurement is made two weeks after launch and another 3 months after launch. Comparisons and correlations are made between different sensors measuring simultaneously. Noise levels are investigated. Filtering is discussed for further refinement of the laser triangulation sensor signals in order to separate noise from actual physical displacement and vibration. Measurements are presented from the relative displacement of the piston rod mechanical lead-through, from magnetic flux in the air gap, mechanical strain in the WEC structure, translator position and piston rod axial displacement and active AC power. Investigation into the measurements in the time domain with close-ups, in the frequency domain with Fast Fourier transform (FFT) and with time-frequency analysis with short time Fourier transform (STFT) is carried out to map the spectral content in the measurements. End stop impact is clearly visible in the time-frequency analysis. The FFT magnitude spectra are investigated for identifying the cogging bandwidth among other vibrations. Generator cogging, fluctuations in the damping force and in the Lorenz forces in the stator are distinguished and varies depending on translator speed. Vibrations from cogging seem to be present in the early measurement period while not so prominent in the late measurement period. Vibration frequencies due to wear are recognized by comparing with the noise at generator standstill and the vibration sources in the generator. It is concluded that a moving average is a sufficient filter in the time domain for further analysis of the relative displacement of the piston rod mechanical lead-through transmission. 展开更多
关键词 Wave Power Wave energy Converter Linear Generator Sensor measurements Spectral Analysis COGGING Filtering Laser Triangulation Sensor Draw-Wire Sensor Force Transducer Strain Gauges Search Coil Power Generation
下载PDF
Measurement and analysis of airtightness safeguard measures for typical ultra-low energy buildings 被引量:1
15
作者 Yongming Ji Lin Duanmu Songtao Hu 《Energy and Built Environment》 2024年第3期348-363,共16页
Zero-energy buildings constitute an effective means of reducing urban carbon emissions.High airtightness,a typical characteristic of zero-energy building,is closely related to the building’s air infiltration and has ... Zero-energy buildings constitute an effective means of reducing urban carbon emissions.High airtightness,a typical characteristic of zero-energy building,is closely related to the building’s air infiltration and has a signifi-cant impact on the performance of the building envelope,indoor air quality,building energy consumption,and efficient operation of air-conditioning systems.However,thus far,systematic developments in high-airtightness assurance technologies remain scarce.Most existing studies have tested the airtightness of buildings and typical building components;however,in-depth analyses into the formation of infiltration have not been reported.There-fore,for realizing zero-energy buildings,ensuring airtightness is an urgent problem that needs to be addressed.Accordingly,in this study,based on several building airtightness measurement studies,the typical air leakage paths in buildings were summarized,and the causes of typical air leakage components in buildings were further analysed by tracing construction processes.Moreover,targeted measures for airtightness in buildings were estab-lished and applied to practical cases.Lastly,the resulting improved building airtightness was measured and the results show that the airtightness of the measured ultra-low energy consumption buildings ranges from 0.13 h^(−1)to 0.57 h^(−1),with a mean value of 0.32 h^(−1).The effectiveness of the airtightness safeguard measures was verified.This study serves as a basis for the assumption of the air leakage path distribution when simulating building air infiltration and also provides a design reference for improving the construction technologies and airtightness of buildings. 展开更多
关键词 Carbon neutrality AIRTIGHTNESS Safeguard measures Ultra-low energy buildings
原文传递
The electrical parameters measurement system for electrotome output based on Labview 被引量:3
16
作者 Shengjie Yan Yu Zhou +3 位作者 Bowen Yan Dianli Li Chengli Song Zhaohua Chang 《Journal of Biomedical Science and Engineering》 2013年第6期661-668,共8页
An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system... An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system based on personal computer (PC) is developed hereby. It senses voltage and current in isolation from generators with transformers, and then the measured values are amplified, filtered, transformed into single-ended signals and converted to RMS. The detected signals are transformed into digital signals through Data Acquisition Card (DAQ) and the data are processed with quadratic fit in Labview. Finally, the controller completes constant power output. The experiment results indicate that the energy detection system can measure the output parameters precisely and the controller can achieve constant power control. 展开更多
关键词 : energy GENERATOR HIGH-FREQUENCY Electrical PARAMETERS measurement CONSTANT Power
下载PDF
Are energy conservation and emission reduction policy measures effective for industrial structure restructuring and upgrading? 被引量:1
17
作者 Guoxing Zhang Peide Zhang +1 位作者 Jing Xiu Jian Chai 《Chinese Journal of Population,Resources and Environment》 2018年第1期12-27,共16页
The use of energy conservation emission reduction policies to promote industrial restructuring and upgrading and thus facilitate energy conservation and emission reduction is one of the 10 important strategies of envi... The use of energy conservation emission reduction policies to promote industrial restructuring and upgrading and thus facilitate energy conservation and emission reduction is one of the 10 important strategies of environmental management in China. The use of energy conservation emission reduction policies to promote industrial restructuring and upgrading and thus facilitate energy conservation and emission reduction is one of the important strategies of environmental management in China. Based on the systematic collection of 1,195 energy conservation emission reduction policies, we discuss the influence of individual measure and measure synergy of energy conservation and emission reduction policies respectively. The results show that the energy conservation and emission reduction policies have a significant effect on the overall promotion of industrial upgrading. The financial measures and guidance measures have a positive impact;the financial measures and guidance measures have significantly positive effect; however, the administrative measures, fiscal tax measures, and other economic measures do the opposite; the positive effect of the synergy of guidance measures and financial measures is greater than the negative effect of considering only the synergy of fiscal tax measures and other economic measures, and significantly greater than the negative effect of the synergy of administrative measures, fiscal tax measures, and other economic measures. We should strengthen and emphasize the use of the measure that has positive effect on industrial structure restructuring and upgrading individually and synergistically. 展开更多
关键词 energy conservation and emission reduction policy quantification measure synergy HAC unit rootcointegration
下载PDF
A Novel Bidirectional Interaction Model and Electric Energy Measuring Scheme of EVs for V2G with Distorted Power Loads 被引量:1
18
作者 Jiarui Cui Qing Li +2 位作者 Bin Cao Xiangquan Li Qun Yan 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第3期1789-1806,共18页
With the increasing demand for petroleum resources and environmental issues,new energy electric vehicles are increasingly being used.However,the large number of electric vehicles connected to the grid has brought new ... With the increasing demand for petroleum resources and environmental issues,new energy electric vehicles are increasingly being used.However,the large number of electric vehicles connected to the grid has brought new challenges to the operation of the grid.Firstly,A novel bidirectional interaction model is established based on modulation theory with nonlinear loads.Then,the electric energy measuring scheme of EVs for V2G is derived under the conditions of distorted power loads.The scheme is composed of fundamental electric energy,fundamental-distorted electric energy,distorted-fundamental electric energy and distorted electric energy.And the characteristics of each electric energy are analyzed.Finally,the correctness of the model and energy measurement method is verified by three simulation cases:the impact signals,the fluctuating signals,and the harmonic signals. 展开更多
关键词 Electric vehicles V2G energy metering bidirectional interaction model electric energy measuring scheme
下载PDF
Non-invasive glucose measuring apparatus based on conservation of energy method 被引量:1
19
作者 陈真诚 金星亮 +2 位作者 朱健铭 王弟亚 张婷婷 《Journal of Central South University》 SCIE EI CAS 2009年第6期982-986,共5页
A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardwa... A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardware and software of this apparatus were designed,and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism,and the relationship between convection,evaporation,radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method,using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other,and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A:100%,region B:0%). Accordingly,it is feasible to measure BGL with COEM. 展开更多
关键词 single chip non-invasive measurement blood glucose conservation of energy method
下载PDF
Processing of measurement while drilling data for rock mass characterization 被引量:4
20
作者 Babaei Khorzoughi Mohammad Hall Robert 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2016年第6期989-994,共6页
The information extracted from monitoring of rotary blasthole drills helps to optimize the overall mining operation. Rock hardness, drillability, blastability and specific energy of drilling are examples of parameters... The information extracted from monitoring of rotary blasthole drills helps to optimize the overall mining operation. Rock hardness, drillability, blastability and specific energy of drilling are examples of parameters that have been estimated in the past using measurement while drilling techniques. In order to be able to properly utilize measurement while drilling techniques, it is important to properly collect, analyze and interpret extracted data. This paper deals with processing of measurement while drilling data such as rate of penetration, rotary speed, rotary torque and pulldown force collected from rotary blasthole drills.Different methods are discussed to calculate a true rate of penetration which is the most important monitored drill variable for use in rock mass characterization. Then specific energy of drilling is defined and calculated based on electrical and mechanical inputs and the results are compared. The results show that specific energy of drilling can be estimated using the drill's primary drive systems' electrical responses with good accuracy when compared to values based on mechanical inputs. 展开更多
关键词 measurement while drilling Rotary blasthole drill Specific energy Rate of penetration
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部