期刊文献+
共找到6,925篇文章
< 1 2 250 >
每页显示 20 50 100
Simultaneous determination of some trace metal impurities in high-purity sodium tungstate using coprecipitation and inductively coupled plasma atomic emission spectrometry 被引量:3
1
作者 MAXiaoguo KUANGTongchun LIUQianjun 《Rare Metals》 SCIE EI CAS CSCD 2004年第3期193-196,共4页
A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements... A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%. 展开更多
关键词 analytical chemistry trace metal determination inductively coupled plasmaatomic emission spectrometry (ICP-AES) coprecipitation sodium tungstate
下载PDF
Determination of micro yttrium in an ytterbium matrix by inductively coupled plasma atomic emission spectrometry and wavelet transform 被引量:2
2
作者 MAXiaoguo 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期137-141,共5页
In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong inte... In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods. 展开更多
关键词 analytical chemistry trace analysis inductively coupled plasma atomicemission spectrometry (ICP-AES) wavelet transform spectral interference correction YTTRIUM YTTERBIUM
下载PDF
Atomic Emission Spectrometry of Inductively Coupled Plasma with Sample Introduction by Electrothermal Vaporization
3
作者 Huang Min , Jiang Zucheng Zeng Yun’ e (Department of Chemistry, Wuhan University, Wuhan) Present address, Center of Material Research and Testing, Wuhan University of Technology, Wuhan. To Whom correspondence should be addressed. 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1991年第1期27-31,共5页
A system is described in which a graphite furnace electrothermal vaporization device is employed for the introduction of microlitre liquid sample into an inductively coupled argon plasma. The technique provides a pico... A system is described in which a graphite furnace electrothermal vaporization device is employed for the introduction of microlitre liquid sample into an inductively coupled argon plasma. The technique provides a picogram detection limit and an adequate precision with a relative standard deviation of 4%. Mechanism of analyte condensation in transport process is explored. As an application, the technique combined with DDTC/CCl4 extraction is used to enrich and determine non- rare earth impurities in highly pure La2O3. 展开更多
关键词 Electrothermal sample introduction inductively coupled plasma Optical emis-sion spectrometry
下载PDF
The determination of 52 elements in marine geological samples by an inductively coupled plasma optical emission spectrometry and an inductively coupled plasma mass spectrometry with a high-pressure closed digestion method 被引量:13
4
作者 GAO Jingjing LIU Jihua +3 位作者 LI Xianguo YAN Quanshu WANG Xiaojing WANG Hongmin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第1期109-117,共9页
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud... An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples. 展开更多
关键词 marine geological sample high-pressure closed digestion method inductively coupled plasma optical emission spectrometry inductively coupled plasma mass spectrometry major element minor element trace element
下载PDF
A Perspective of Laser Sampling for Inductively Coupled Plasma-Atomic Emission Spectro metry for Rock and Mineral Analysis
5
作者 Lin Shoulin Peng ZhaofengChina University of Geosciences , Wuhan 430074 《Journal of Earth Science》 SCIE CAS CSCD 1992年第1期120-128,共9页
The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp... The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well. 展开更多
关键词 continuous laser sampling complete laser vaporization of samples inductively coupled plasma-atomic emission spectrometry solid sample liquid sample rock and mineral analysis .
下载PDF
Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry 被引量:10
6
作者 XIE Hualin HUANG Kelong +1 位作者 NIE Xidu TANG Yougen 《Rare Metals》 SCIE EI CAS CSCD 2007年第3期286-291,共6页
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ... A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect standard addition method
下载PDF
Quantification of Trace Amounts of Impurities in High Purity Cobalt by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:3
7
作者 Hua Lin XIE Xi Du NIE You Gen TANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1077-1080,共4页
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ... An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 High resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect spectral interference internal standards.
下载PDF
Direct Determination of Trace Impurities in High Purity Zinc Oxide by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:2
8
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第2期28-32,共5页
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter... The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented. 展开更多
关键词 high purity zinc oxide trace impurities high resolution inductively coupled plasma mass spectrometry spectral interferences microwave digestion
下载PDF
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
9
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents of Mg,Al,Si,Ti,Cr,Mn,Fe,Co,Cu,Ga,As,Se,Cd,Sb,Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry(HR-ICP-MS).The sample was dissolved in HNO3 and... The contents of Mg,Al,Si,Ti,Cr,Mn,Fe,Co,Cu,Ga,As,Se,Cd,Sb,Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry(HR-ICP-MS).The sample was dissolved in HNO3 and HCl by microwave digestion.Most of the spectral interferences could be avoided by measuring in the high resolution mode.The matrix effects because of the presence of excess HCl and nickel were evaluated.Correction for matrix effects was made using Sc,Rh and Tl as internal standards.The optimum conditions for the determination were tested and discussed.The detection limits range from 0.012 to 1.76 μg/g depending on the type of elements.The applicability of the proposed method is also validated by the analysis of high purity nickel reference material(NIST SRM 671).The relative standard deviation(RSD) is less than 3.3%.Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 电感耦合等离子体质谱法 高分辨率模式 痕量元素 高纯镍 镍测定 ICP-MS 最佳工艺条件 相对标准偏差
下载PDF
Determination of Trace Elements in High Purity Gold by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:1
10
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第4期608-612,共5页
Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/... Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/ interference, measurements were acquired in both medium and high resolution modes. The matrix effects due to the presence of excessive HCl and Au were evaluated. The optimum conditions for the determination was tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits range from 0.01ug/g to 0.28ug/g depending on the elements. The method is accurate, quick and convenient. It has been applied to the determination of trace elements in high purity gold with satisfactory results. 展开更多
关键词 high purity gold trace elements high resolution inductively coupled plasma mass spectrometry spectral interferences
下载PDF
Analysis of Cu,Co,V and Zn in Coastal Waters of the East China Sea by Inductively Coupled Plasma Mass Spectrometry(ICP-MS) 被引量:1
11
作者 YANG Rujun NING Yutong +2 位作者 ZHANG Aibin LI Yan SU Han 《Journal of Ocean University of China》 SCIE CAS 2016年第5期825-834,共10页
In this study, a simple method for the simultaneous determination of trace metals(Cu, V, Co, Zn) in coastal seawater using the Mg(OH)2 coprecipitation inductively coupled plasma mass spectrometry(ICP-MS) was developed... In this study, a simple method for the simultaneous determination of trace metals(Cu, V, Co, Zn) in coastal seawater using the Mg(OH)2 coprecipitation inductively coupled plasma mass spectrometry(ICP-MS) was developed. This multi-element method enables the simultaneous extraction of four metals, particularly Co and V. The recoveries of Cu, Co, V and Zn after Mg(OH)2 coprecipitation were 73%, 96%, 94% and 92%, which means that our procedure was well-suited to the determination of these four trace metals. The detection limits were 3.81, 0.18, 6.09 and 1.91 nmol L-1, respectively. Then, applying this method to the simultaneous determination of these four metals in coastal water samples from the East China Sea revealed that the concentrations of Cu, Zn, Co and V were higher in bottom waters compared to water at other depths, and higher concentrations were generally observed at the Yangtze River estuary. Additionally, example vertical profiles of dissolved trace metal concentrations for the East China Sea in spring and autumn are compared. These findings indicate that Zn had the greatest seasonal variation followed by Cu, V and Co. For Zn and Co, the concentrations were higher during spring than during autumn. For Cu and V, the seasonal variation in the concentrations was opposite. 展开更多
关键词 trace metals inductively coupled plasma mass spectrometry Mg(OH)2 co-precipitation East China Sea coastal water
下载PDF
Determination of trace multi-elements in coal fly ash by inductively coupled plasma mass spectrometry 被引量:4
12
作者 谢华林 唐有根 +1 位作者 李玉杰 李立波 《Journal of Central South University of Technology》 EI 2007年第1期68-72,共5页
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with... The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and HF. The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%. 展开更多
关键词 粉煤灰 微波消化 等离子体 光谱测定
下载PDF
Determination of impurity elements in MnZn ferrites by inductively coupled plasma mass spectrometry 被引量:3
13
作者 张萍 符靓 +1 位作者 马俊才 唐有根 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期37-42,共6页
An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+H... An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%. 展开更多
关键词 电感耦合等离子体质谱法 MNZN铁氧体 杂质元素 测定 ICP-MS 相对标准偏差 微波消解 样品消化
下载PDF
Trace amounts of impurities in electrolytic manganese metal by sector field inductively coupled plasma mass spectrometry 被引量:2
14
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2013年第12期3385-3390,共6页
An analytical method, using sector field inductively coupled plasma mass spectrometry(SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in elec... An analytical method, using sector field inductively coupled plasma mass spectrometry(SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in electrolytic manganese metal, was described. At the beginning, the samples were decomposed by HNO3 and H2 SO4, and then analyzed by SF-ICP-MS. Most of the spectral interferences could be avoided by measuring in different mass resolution modes. The matrix effects due to the excess of sulfuric acid and Mn were evaluated. Correction of matrix effects was conducted by using the internal standard elements. The optimum condition for the determination was investigated and discussed. The detection limit is in the range of 0.001 0.169 μg/L. The current method is applied to the determination of trace impurities in electrolytic manganese metal. And experiments show that good results can be obtained much faster, more accurately and conveniently by current method. 展开更多
关键词 电感耦合等离子体质谱法 电解金属锰 微量杂质 基体效应校正 金额 行业 同时测定 质量分辨率
下载PDF
Speciation of Volatile Selenium Species in Plants Using Gas Chromatography/Inductively Coupled Plasma Mass Spectrometry 被引量:1
15
作者 Juris MEIJA Maria MONTES-BAYN +2 位作者 Joseph A CARUSO Danika L LEDUC Norman TERRY 《色谱》 CAS CSCD 北大核心 2004年第1期16-19,共4页
Gas chromatography/inductively coupled plasma mass spectrometry (GC/ICP-MS) coupled with solid phase micro-extraction can provide a simple, extremely selective and sensitive technique for the analysis of volatile sulf... Gas chromatography/inductively coupled plasma mass spectrometry (GC/ICP-MS) coupled with solid phase micro-extraction can provide a simple, extremely selective and sensitive technique for the analysis of volatile sulfur and selenium compounds in the headspace of growing plants. In this work, the technique was used to evaluate the volatilization of selenium in wild-type and genetically-modified Brassica juncea seedlings. By converting toxic inorganic selenium in the soil to less toxic, volatile organic selenium, B. juncea might be useful in bioremediation of selenium contaminated soil. 展开更多
关键词 植物 挥发性硒化合物 含量测定 气相色谱法 电感耦合等离子体质谱法
下载PDF
Uncertainty Evaluation of Simultaneous Determination of Lead, Cadmium and Arsenic in Cosmetics by Inductively Coupled Plasma Mass Spectrometry 被引量:1
16
作者 Cui Xiaojiao Wang Hui +3 位作者 Zhou Peng Zhou Tanchun Cao Xiongjie Hu Yuge 《China Detergent & Cosmetics》 2020年第1期68-74,共7页
This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115I... This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability. 展开更多
关键词 COSMETICS uncertainty inductively coupled plasma mass spectrometry(ICP-MS) heavy metals
下载PDF
Determination of Carbon by Means of Microwave Plasma Torch Atomic Emission Spectrometry
17
作者 ZHANG Han-qi YUAN Xiang-lin +1 位作者 YE Dong-mei ZHAO Xiao-jun and JIN Qin-han (Department Of Chemistry, Jilin University, Changchun, 130023)ZHU Zhi-ping(Department of Chemistry, Northeast Normal University, Changchun, 130024) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1996年第1期32-36,共5页
The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon wa... The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon was 0. 047μg/mL.The method was applied to the analysis for tap water and results were satisfactory. 展开更多
关键词 Microwave plasma torch atomic emission spectrometry CARBON
下载PDF
A Study on Determination of Some Trace Nonmetals by Microwave Induced Plasma Atomic Emission Spectrometry
18
作者 Zhang Jinsheng, Ye Dongmei, Zhang Hanqi and Jin Qinhan (Department of Chemistry, Jilin University, Changchun) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1992年第1期29-30,共2页
In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the res... In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the resonance lines of most nonmetals lie in the vacuum ultraviolet spectral region and the ionic lines of these elements are difficult to be used because the ionization potentials of the elements are very high. And furthermore only He plasma can efficiently excit those ionic resonance lines. The practical application of HeICP-AES to determining the nonmetals is also difficult because its operating and perchace costs are very high. In contrast to HeICPAES, the costs of He microwave induced plasma (MIP)-AES are relatively low, HeMIP has a high excitation capability which can excite ionic lines of various nonmetals and the nonmetals can be determined by HeMIP-AES with a high sensitivity. 展开更多
关键词 Microwave induced plasma atomic emission spectrometry NONMETALS
下载PDF
Studies on Combination of Flow Injection and Microwave Plasma Torch-Atomic Emission Spectrometry
19
作者 YE Dong-mei, ZHAO Jing-hong, ZHANG Han-qi and JIN Qin-han (Department of Chemistry, Jilin University, Changchun, 130023)DONG De-fan (Hebei College of Geology, Shijiazhuang, 050031) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第3期246-247,共2页
Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma syst... Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma systems. Gehlausen et al. determined aqueous fluorine by coupling flow injection analysis (FIA) with HeMIP 展开更多
关键词 Microwave plasma torch Flow injection atomic emission spectrometry
下载PDF
On Line Anion Exchange Preconcentration in Microwave Plasma Torch Atomic Emission Spectrometry
20
《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第1期43-44,共2页
OnLineAnionExchangePreconcentrationinMicrowavePlasmaTorchAtomicEmissionSpectrometryLIANGFeng;ZHANGHan-qiandJ... OnLineAnionExchangePreconcentrationinMicrowavePlasmaTorchAtomicEmissionSpectrometryLIANGFeng;ZHANGHan-qiandJINQin-han(Departm... 展开更多
关键词 Microwave plasma torch atomic emission spectrometry Preconcen-tration
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部