The best stop to shop for innovation The Taipei Innovative Textile Application Show (TITAS 2010),organized by the Taiwan Textile Federation (TTF) will be held at the Taipei World Trade Center on October 13 through 15,...The best stop to shop for innovation The Taipei Innovative Textile Application Show (TITAS 2010),organized by the Taiwan Textile Federation (TTF) will be held at the Taipei World Trade Center on October 13 through 15, 2010. More than 300 exhibitors with 500 booths from all over the world are expected to be part of the annual gathering.展开更多
Experimental research center and research oriented model, is to test basic skills and the application of technology as the main line,to cultivate students’ comprehensive experimental skills, to add professional and t...Experimental research center and research oriented model, is to test basic skills and the application of technology as the main line,to cultivate students’ comprehensive experimental skills, to add professional and technical capacity and integrated design experiment teachingpractice session, and introduce scientifi c research and experimental teaching, training students to scientifi c thinking to teaching model whichanalyze and solve problems. This mode has positive and stimulating effect on comprehensive quality and innovative ability for students usingmodern science and technology to solve practical engineering problems .this paper discusses the research status and the innovative application ofmaterials science experiments and teaching professional research-oriented, and proposes an effective way to improve this kind of new model.展开更多
Integer Ambiguity Resolution(IAR)can significantly improve the accuracy of GNSS Precise Orbit Determination(POD).Traditionally,the IAR in POD is achieved at the Double Differenced(DD)level.In this contribution,we deve...Integer Ambiguity Resolution(IAR)can significantly improve the accuracy of GNSS Precise Orbit Determination(POD).Traditionally,the IAR in POD is achieved at the Double Differenced(DD)level.In this contribution,we develop an Un-Differenced(UD)IAR method for Global Positioning System(GPS)+BeiDou Navigation Satellite System(BDS)+Galileo navigation satellite system(Galileo)+Global'naya Navigatsionnaya Sputnikovaya Sistema(GLONASS)quad-system POD by calibrating UD ambiguities in the raw carrier phase and generating the so-called carrier range.Based on this method,we generate the UD ambiguity-fixed orbit and clock products for the Wuhan Innovation Application Center(IAC)of the International GNSS Monitoring and Assessment System(iGMAS).One-year observations in 2020 from 150 stations are employed to investigate performance of orbit and clock products.Notably,the UD Ambiguity Resolution(AR)yields more resolved integer ambiguities than the traditional DD AR,scaling up to 9%,attributable to its avoidance of station baseline formation.Benefiting from the removal of ambiguity parameters,the computational efficiency of parameter estimation undergoes a substantial 70%improvement.Compared with the float solution,the orbit consistencies of UD AR solution achieve the accuracy of 1.9,5.2,2.8,2.1,and 2.7 cm for GPS,BeiDou-2 Navigation Satellite System(BDS-2),BeiDou-3 Navigation Satellite System(BDS-3),Galileo,and GLONASS satellites respectively,reflecting enhancements of 40%,24%,54%,34%,and 42%.Moreover,the standard deviations of Satellite Laser Ranging(SLR)residuals are spanning 2.5–3.5 cm,underscoring a comparable accuracy to the DD AR solution,with discrepancies below 5%.A notable advantage of UD AR lies in its capability to produce the Integer Recovered Clock(IRC),facilitating Precise Point Positioning(PPP)AR without requiring additional Uncalibrated Phase Delay(UPD)products.To assess the performance of quad-system kinematic PPP based on IRC,a network comprising 120 stations is utilized.In comparison to the float solution,the IRC-based PPP AR accelerates convergence time by 31%and enhance positioning accuracy in the east component by 54%.展开更多
The world record device efficiency of single-junction solar cells based on organic–inorganic hybrid perovskites has reached 25.5%.Further improvement in device power conversion efficiency(PCE)can be achieved by eithe...The world record device efficiency of single-junction solar cells based on organic–inorganic hybrid perovskites has reached 25.5%.Further improvement in device power conversion efficiency(PCE)can be achieved by either optimizing perovskite films or designing novel device structures such as perovskite/Si tandem solar cells.With the marriage of perovskite and Si solar cells,a tandem device configuration is able to achieve a PCE exceeding the Shockley–Queisser limit of single-junction solar cells by enhancing the usage of solar spectrum.After several years of development,the highest PCE of the perovskite/Si tandem cell has reached 29.5%,which is higher than that of perovskite-and Si-based singlejunction cells.Here,in this review,we will(1)first discuss the device structure and fundamental working principle of both two-terminal(2T)and four-terminal(4T)perovskite/Si tandem solar cells;(2)second,provide a brief overview of the advances of perovskite/Si tandem solar cells regarding the development of interconnection layer,perovskite active layer,tandem device structure,and lightmanagement strategies;(3)third,discuss the challenges and opportunities for further developing perovskite/Si tandem solar cells.This review article,on the one hand,provides a comprehensive understanding to readers on the development of perovskite/Si tandems.On the other hand,it proposes various novel applications that may bring such tandems into the market in a near future.展开更多
Traditional Chinese Medicine(TCM)has been used in prevention and treatment of disease in clinical practice for thousands of years,with an indispensable role of multiple ingredients.Thus,a rapid and effective chemical ...Traditional Chinese Medicine(TCM)has been used in prevention and treatment of disease in clinical practice for thousands of years,with an indispensable role of multiple ingredients.Thus,a rapid and effective chemical ingredients analysis was of necessary to be established for the evaluation of the holistic quality of TCM.As could afford the data with high resolution and high sensitivity,展开更多
Over the past years the International Global Navigation Satellite System(GNSS)Monitoring and Assessment System(iGMAS)Wuhan Innovation Application Center(IAC)dedicated to exploring the potential of multi-GNSS signals a...Over the past years the International Global Navigation Satellite System(GNSS)Monitoring and Assessment System(iGMAS)Wuhan Innovation Application Center(IAC)dedicated to exploring the potential of multi-GNSS signals and providing a set of products and services.This contribution summarizes the strategies,achievements,and innovations of multi-GNSS orbit/clock/bias determination in iGMAS Wuhan IAC.Both the precise products and Real-Time Services(RTS)are evaluated and discussed.The precise orbit and clock products have comparable accuracy with the precise products of the International GNSS Service(IGS)and iGMAS.The multi-frequency code and phase bias products for Global Positioning System(GPS),BeiDou Navigation Satellite System(BDS),Galileo navigation satellite system(Galileo),and GLObal NAvigation Satellite System(GLONASS)are provided to support multi-GNSS and multi-frequency Precise Point Positioning(PPP)Ambiguity Resolution(AR).Compared with dual-frequency PPP AR,the time to first fix of triple-frequency solution is improved by 30%.For RTS,the proposed orbit prediction strategy improves the three dimensional accuracy of predicted orbit by 1 cm.The multi-thread strategy and high-performance matrix library are employed to accelerate the real-time orbit and clock determination.The results with respect to the IGS precise products show the high accuracy of RTS orbits and clocks,4–9 cm and 0.1–0.2 ns,respectively.Using real-time satellite corrections,real-time PPP solutions achieve satisfactory performance with horizontal and vertical positioning errors within 2 and 4 cm,respectively,and convergence time of 16.97 min.展开更多
文摘The best stop to shop for innovation The Taipei Innovative Textile Application Show (TITAS 2010),organized by the Taiwan Textile Federation (TTF) will be held at the Taipei World Trade Center on October 13 through 15, 2010. More than 300 exhibitors with 500 booths from all over the world are expected to be part of the annual gathering.
文摘Experimental research center and research oriented model, is to test basic skills and the application of technology as the main line,to cultivate students’ comprehensive experimental skills, to add professional and technical capacity and integrated design experiment teachingpractice session, and introduce scientifi c research and experimental teaching, training students to scientifi c thinking to teaching model whichanalyze and solve problems. This mode has positive and stimulating effect on comprehensive quality and innovative ability for students usingmodern science and technology to solve practical engineering problems .this paper discusses the research status and the innovative application ofmaterials science experiments and teaching professional research-oriented, and proposes an effective way to improve this kind of new model.
基金supported by the National Natural Science Foundation of China(No.42204017,No.41974027,No.42304019)the special fund of Hubei Luojia Laboratory(220100006)+1 种基金the Sino-German mobility program(Grant No.M-0054),China Postdoctoral Science Foundation(2023M732687)the Fundamental Research Funds for the Central Universities(2042022kf1001).
文摘Integer Ambiguity Resolution(IAR)can significantly improve the accuracy of GNSS Precise Orbit Determination(POD).Traditionally,the IAR in POD is achieved at the Double Differenced(DD)level.In this contribution,we develop an Un-Differenced(UD)IAR method for Global Positioning System(GPS)+BeiDou Navigation Satellite System(BDS)+Galileo navigation satellite system(Galileo)+Global'naya Navigatsionnaya Sputnikovaya Sistema(GLONASS)quad-system POD by calibrating UD ambiguities in the raw carrier phase and generating the so-called carrier range.Based on this method,we generate the UD ambiguity-fixed orbit and clock products for the Wuhan Innovation Application Center(IAC)of the International GNSS Monitoring and Assessment System(iGMAS).One-year observations in 2020 from 150 stations are employed to investigate performance of orbit and clock products.Notably,the UD Ambiguity Resolution(AR)yields more resolved integer ambiguities than the traditional DD AR,scaling up to 9%,attributable to its avoidance of station baseline formation.Benefiting from the removal of ambiguity parameters,the computational efficiency of parameter estimation undergoes a substantial 70%improvement.Compared with the float solution,the orbit consistencies of UD AR solution achieve the accuracy of 1.9,5.2,2.8,2.1,and 2.7 cm for GPS,BeiDou-2 Navigation Satellite System(BDS-2),BeiDou-3 Navigation Satellite System(BDS-3),Galileo,and GLONASS satellites respectively,reflecting enhancements of 40%,24%,54%,34%,and 42%.Moreover,the standard deviations of Satellite Laser Ranging(SLR)residuals are spanning 2.5–3.5 cm,underscoring a comparable accuracy to the DD AR solution,with discrepancies below 5%.A notable advantage of UD AR lies in its capability to produce the Integer Recovered Clock(IRC),facilitating Precise Point Positioning(PPP)AR without requiring additional Uncalibrated Phase Delay(UPD)products.To assess the performance of quad-system kinematic PPP based on IRC,a network comprising 120 stations is utilized.In comparison to the float solution,the IRC-based PPP AR accelerates convergence time by 31%and enhance positioning accuracy in the east component by 54%.
基金National Key Research and Development Program of China,Grant/Award Number:2017YFA0206600National Natural Science Foundation of China,Grant/Award Numbers:51773045,21772030,51922032,21961160720。
文摘The world record device efficiency of single-junction solar cells based on organic–inorganic hybrid perovskites has reached 25.5%.Further improvement in device power conversion efficiency(PCE)can be achieved by either optimizing perovskite films or designing novel device structures such as perovskite/Si tandem solar cells.With the marriage of perovskite and Si solar cells,a tandem device configuration is able to achieve a PCE exceeding the Shockley–Queisser limit of single-junction solar cells by enhancing the usage of solar spectrum.After several years of development,the highest PCE of the perovskite/Si tandem cell has reached 29.5%,which is higher than that of perovskite-and Si-based singlejunction cells.Here,in this review,we will(1)first discuss the device structure and fundamental working principle of both two-terminal(2T)and four-terminal(4T)perovskite/Si tandem solar cells;(2)second,provide a brief overview of the advances of perovskite/Si tandem solar cells regarding the development of interconnection layer,perovskite active layer,tandem device structure,and lightmanagement strategies;(3)third,discuss the challenges and opportunities for further developing perovskite/Si tandem solar cells.This review article,on the one hand,provides a comprehensive understanding to readers on the development of perovskite/Si tandems.On the other hand,it proposes various novel applications that may bring such tandems into the market in a near future.
文摘Traditional Chinese Medicine(TCM)has been used in prevention and treatment of disease in clinical practice for thousands of years,with an indispensable role of multiple ingredients.Thus,a rapid and effective chemical ingredients analysis was of necessary to be established for the evaluation of the holistic quality of TCM.As could afford the data with high resolution and high sensitivity,
基金National Natural Science Foundation of China(No.41974027)National Key Research and Development Program of China(2021YFB2501102)Sino-German mobility programme(Grant No.M-0054).
文摘Over the past years the International Global Navigation Satellite System(GNSS)Monitoring and Assessment System(iGMAS)Wuhan Innovation Application Center(IAC)dedicated to exploring the potential of multi-GNSS signals and providing a set of products and services.This contribution summarizes the strategies,achievements,and innovations of multi-GNSS orbit/clock/bias determination in iGMAS Wuhan IAC.Both the precise products and Real-Time Services(RTS)are evaluated and discussed.The precise orbit and clock products have comparable accuracy with the precise products of the International GNSS Service(IGS)and iGMAS.The multi-frequency code and phase bias products for Global Positioning System(GPS),BeiDou Navigation Satellite System(BDS),Galileo navigation satellite system(Galileo),and GLObal NAvigation Satellite System(GLONASS)are provided to support multi-GNSS and multi-frequency Precise Point Positioning(PPP)Ambiguity Resolution(AR).Compared with dual-frequency PPP AR,the time to first fix of triple-frequency solution is improved by 30%.For RTS,the proposed orbit prediction strategy improves the three dimensional accuracy of predicted orbit by 1 cm.The multi-thread strategy and high-performance matrix library are employed to accelerate the real-time orbit and clock determination.The results with respect to the IGS precise products show the high accuracy of RTS orbits and clocks,4–9 cm and 0.1–0.2 ns,respectively.Using real-time satellite corrections,real-time PPP solutions achieve satisfactory performance with horizontal and vertical positioning errors within 2 and 4 cm,respectively,and convergence time of 16.97 min.