期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Resolving double-sided inverse heat conduction problem using calibration integral equation method
1
作者 CHEN Hong-chu 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2100-2108,共9页
In this paper, a novel calibration integral equation is derived for resolving double-sided, two-probe inverse heat conduction problem of surface heat flux estimation. In contrast to the conventional inverse heat condu... In this paper, a novel calibration integral equation is derived for resolving double-sided, two-probe inverse heat conduction problem of surface heat flux estimation. In contrast to the conventional inverse heat conduction techniques, this calibration approach does not require explicit input of the probe locations, thermophysical properties of the host material and temperature sensor parameters related to thermal contact resistance, sensor capacitance and conductive lead losses. All those parameters and properties are inherently contained in the calibration framework in terms of Volterra integral equation of the first kind. The Laplace transform technique is applied and the frequency domain manipulations of the heat equation are performed for deriving the calibration integral equation. Due to the ill-posed nature, regularization is required for the inverse heat conduction problem, a future-time method or singular value decomposition (SVD) can be used for stabilizing the ill-posed Volterra integral equation of the first kind. 展开更多
关键词 inverse heat conduction problem surface heat flux estimation calibration integral equation method
下载PDF
Calibration of Soil Electromagnetic Conductivity in Inverted Salinity Profiles with an Integration Method 被引量:9
2
作者 YAO Rong-Jian YANG Jin-Song LIU Guang-Ming 《Pedosphere》 SCIE CAS CSCD 2007年第2期246-256,共11页
Various calibration methods have been propounded to determine profiles of apparent bulk soil electrical conductivity (ECa) and soil electrical conductivity of a saturated soil paste extract (ECe) or a 1:5 soil water e... Various calibration methods have been propounded to determine profiles of apparent bulk soil electrical conductivity (ECa) and soil electrical conductivity of a saturated soil paste extract (ECe) or a 1:5 soil water extract (EC1:5) using an electromagnetic induction instrument (EM38). The modeled coefficients, one of the successful and classical methods hitherto, were chosen to calibrate the EM38 measurements of the inverted salinity profiles of characteristic coastal saline soils at selected sites of Xincao Farm, Jiangsu Province, China. However, this method required three parameters for each depth layer. An integration approach, based on an exponential decay profile model, was proposed and the model was fitted to all the calibration sites. The obtained model can then be used to predict EC1:5 at a certain depth from electromagnetic measurements made using the EM38 device positioned in horizontal and vertical positions at the soil surface. This exponential decay model predicted the EC1:5 well according to the results of a one-way analysis of variance, and the further comparison indicated that the modeled coefficients appeared to be slightly superior to, but not statistically different from, this exponential decay model. Nevertheless, this exponential decay model was more significant and practical because it depended on less empirical parameters and could be used to perform point predictions of EC1:5 continuously with depth. 展开更多
关键词 coastal saline soils electromagnetic conductivity exponential decay model integration calibration method inverted salinity profiles
下载PDF
Calibration of a rule-based intelligent network simulation model 被引量:1
3
作者 A. A. Memon M. Meng +1 位作者 Y. D. Wong S. H. Lam 《Journal of Modern Transportation》 2016年第1期48-61,共14页
This paper is focused on calibration of an intelligent network simulation model (INS1M) with reallife transportation network to analyse the INSIM's feasibility in simulating commuters' travel choice behaviour unde... This paper is focused on calibration of an intelligent network simulation model (INS1M) with reallife transportation network to analyse the INSIM's feasibility in simulating commuters' travel choice behaviour under the influence of real-time integrated multimodal traveller information (IMTI). A transportation network model for the central and western areas of Singapore was simulated in PARAMICS and integrated with INSIM expert system by means of an application programming interface to form the INSIM. Upon calibration, INSIM was able to realistically present complicated scenarios in which real-time IMTI was provided to commuters and the network performance measures being recorded. 展开更多
关键词 Traffic simulation Integrated travellerinformation. calibration Mode choice
下载PDF
Calibration chain design based on integrating sphere transfer radiometer for SI-traceable on-orbit spectral radiometric calibration and its uncertainty analysis 被引量:1
4
作者 赵维宁 方伟 +2 位作者 孙立微 崔立红 王玉鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期276-283,共8页
In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM)... In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM) and an integrating sphere transfer radiometer(ISTR) was designed in this paper.Depending on the Sun,this chain based on detectors provides precise spectral radiometric calibration and measurement to spectrometers in the reflective solar band(RSB) covering 300–2500 nm with a spectral bandwidth of 0.5–6 nm.It shortens the traditional chain based on lamp source and reduces the calibration uncertainty from 5% to 0.5% by using the cryogenic radiometer in space as a radiometric benchmark and trap detectors as secondary standard.This paper also gives a detailed uncertainty budget with reasonable distribution of each impact factor,including the weak spectral signal measurement with uncertainty of 0.28%.According to the peculiar design and comprehensive uncertainty analysis,it illustrates that the spectral radiance measurement uncertainty of the ISTR system can reach to 0.48%.The result satisfies the requirements of SI-traceable on-orbit calibration and has wider significance for expanding the application of the remote sensing data with high-quality. 展开更多
关键词 SI-traceable calibration on-orbit high-accuracy transfer chain integrating sphere transfer radiometer uncertainty analysis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部