期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Determination of zidovudine using anion exchange chromatography with integrated pulsed amperometric detection
1
作者 Yu Chen Yu Xiu Liu +2 位作者 Zhi Dong Chen Mei Lan Chen Yan Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第6期715-718,共4页
A rapid and practical method for direct detection of zidovudine in high performance anion exchange chromatography (HPAEC) has been developed with integrated pulsed amperometric detection (IPAD). Dionex AS18 (250m... A rapid and practical method for direct detection of zidovudine in high performance anion exchange chromatography (HPAEC) has been developed with integrated pulsed amperometric detection (IPAD). Dionex AS18 (250mm × 2mm) and AG18 (50 mm× 2 mm) columns and 11 mmol/L NaOH solution were used for separation. Multi-step potential waveform parameters were optimized to maximize the signal-to-noise ratio (S/N). Utilizing an optimized waveform, the repeatability (intra-day) precision and intermediate (inter-day) precision are obtained with relative standard deviation (RSD) of 1.88, 2.27, respectively. The limit of quantification (LOQ) and limit of detection (LOD) were found to be 9.70, 3.0 ng/mL, respectively, with correlation coefficients of 0.9992 over concentration range 0.01-10 μg/mL. The present method was successfully applied to the determination of zidovudine in human plasma. The recoveries of plasma sample spiked by 0.7 μg/mL, 2.7 μg/mL obtained were 95.3-101.5%, with relative standard deviation (RSD) of 2.54%, 2.21%, respectively. 展开更多
关键词 ZIDOVUDINE AIDS integrated pulsed amperometry High performance anion exchange chromatography PLASMA
原文传递
Determination of lisinopril using anion exchange chromatography with integrated pulsed amperometric detection
2
作者 Yu Xiu Liu Dan Shou +3 位作者 Mei Lan Chen Zhi Dong Chen Pei Min Zhang Yan Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第3期335-338,共4页
A rapid and practical method for direct detection of lisinopril in anion exchange chromatography(AEC) has been developed with integrated pulsed amperometric detection(IPAD).Dionex AS 18(250 mm×2 mm) and AG... A rapid and practical method for direct detection of lisinopril in anion exchange chromatography(AEC) has been developed with integrated pulsed amperometric detection(IPAD).Dionex AS 18(250 mm×2 mm) and AG 18(50 mm×2 mm) columns and 40 mmol/L NaOH solution were used for separation.Multi-step potential waveform parameters were optimized to maximize the signal-to-noise ratio(S/N).Utilizing the optimized waveform,the repeatability(intra-day) precision and intermediate(inter-day) precision were obtained with relative standard deviation(RSD) of 0.74,0.93,respectively.The limit of quantification(LOQ) and limit of detection(LOD) were found to be 0.37,0.12ng/mL,respectively,with the correlation coefficient of 0.9998 over concentration range 0.01-1μg/mL.The present method was successfully applied to the determination of lisinopril in human plasma.The recoveries of plasma sample spiked by 0.2μg/mL,0.8μg/mL lisinopril were 98.31-103.23%with RSD of 1.41%, 0.61%,respectively. 展开更多
关键词 LISINOPRIL integrated pulsed amperometry Anion exchange chromatography Angiotensin converting enzyme inhibitor PLASMA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部