期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A Novel Pipelining Encryption Hardware System with High Throughput and High Integration for 5G
1
作者 Yuntao Liu Zesheng Shen +1 位作者 Shuo Fang Yun Wang 《China Communications》 SCIE CSCD 2022年第6期1-10,共10页
This paper presents a ZUC-256 stream cipher algorithm hardware system in order to prevent the advanced security threats for 5 G wireless network.The main innovation of the hardware system is that a six-stage pipeline ... This paper presents a ZUC-256 stream cipher algorithm hardware system in order to prevent the advanced security threats for 5 G wireless network.The main innovation of the hardware system is that a six-stage pipeline scheme comprised of initialization and work stage is employed to enhance the solving speed of the critical logical paths.Moreover,the pipeline scheme adopts a novel optimized hardware structure to fast complete the Mod(231-1)calculation.The function of the hardware system has been validated experimentally in detail.The hardware system shows great superiorities.Compared with the same type system in recent literatures,the logic delay reduces by 47%with an additional hardware resources of only 4 multiplexers,the throughput rate reaches 5.26 Gbps and yields at least 45%better performance,the throughput rate per unit area increases 14.8%.The hardware system provides a faster and safer encryption module for the 5G wireless network. 展开更多
关键词 encryption hardware system for 5G ZUC-256 stream cipher algorithm pipeline scheme throughput rate integration rate
下载PDF
Optimal Initialization and Starting Approach of Synchronous Condenser Integrated Power Grid
2
作者 Puyu Wang Xing Liu +6 位作者 Qingwen Mou Tao Yuan Tianming Gu Hemin Yang Xiao-Ping Zhang Zhengrong Xiang Chunyi Guo 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期248-260,共13页
Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactiv... Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactive power according to the interconnected grids operating conditions.In this paper,different starting control schemes of a SC integrated power grid are investigated providing four main contributions:1)The principle of reactive power support of the SC on the interconnected power grid is analytically studied,providing the establishment of mathematical models.2)Four different starting control schemes are developed for the initialization and SC integration,i.e.in Scheme 1,a preset initial falling speed is directly utilized without initialization;in Scheme 2,a black start sequential control approach with a static frequency converter(SFC)is proposed;in Scheme 3,PI/PD/PID controllers are respectively applied for the excitation device at the speed-falling stage;in Scheme 4,a pre-insertion approach of an energy absorption component with R/L/RL is utilized to suppress the surges at the SC integration instant.3)The dynamic behaviors of four different starting schemes at specific operating stages are evaluated.4)The success rate of SC integration is analyzed to evaluate starting control performance.Performance of the SC interconnected system with four different starting control schemes is evaluated in the timedomain simulation environment PSCAD/EMTDC^(TM).The results prove the superiority of the proposed starting control approach in Scheme 4. 展开更多
关键词 Black start dynamic behaviors excitation system pre-insertion of energy absorption components starting control schemes static frequency converter(SFC) success rate of integration synchronous condenser(SC)
原文传递
WHU-Grace01s:A new temporal gravity field model recovered from GRACE KBRR data alone 被引量:2
3
作者 Zhou Hao Luo Zhicai Zhong Bo 《Geodesy and Geodynamics》 2015年第5期316-323,共8页
A new temporal gravity field model called WHU-Grace01s solely recovered from Gravity Recovery and Climate Experiment (GRACE) K-Band Range Rate (KBRR) data based on dynamic integral approach is presented in this pa... A new temporal gravity field model called WHU-Grace01s solely recovered from Gravity Recovery and Climate Experiment (GRACE) K-Band Range Rate (KBRR) data based on dynamic integral approach is presented in this paper. After meticulously preprocessing of the GRACE KBRR data, the root mean square of its post residuals is about 0.2 micrometers per second, and seventy-two monthly temporal solutions truncated to degree and order 60 are computed for the period from January 2003 to December 2008. After applying the combi- nation filter in WHU-Grace01s, the global temporal signals show obvious periodical change rules in the large-scale fiver basins. In terms of the degree variance, our solution is smaller at high degrees, and shows a good consistency at the rest of degrees with the Release 05 models from Center for Space Research (CSR), GeoForschungsZentrum Potsdam (GFZ) and Jet Pro- pulsion Laboratory 0PL). Compared with other published models in terms of equivalent water height distribution, our solution is consistent with those published by CSR, GFZ, JPL, Delft institute of Earth Observation and Space system (DEOS), Tongji University (Tongji), Institute of Theoretical Geodesy (ITG), Astronomical Institute in University of Bern (AIUB) and Groupe de Recherche de Geodesie Spatiale (GRGS}, which indicates that the accuracy of WHU-Grace01s has a good consistency with the previously published GRACE solutions. 展开更多
关键词 Temporal gravity field model Gravity Recovery and Climate Experiment (GRACE) Dynamic integral approach K-Band Range rate (KBRR) Satellite gravity Spherical harmonics Equivalent water height Geopotential determination
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部