The reliable and intelligent propulsion pressurization system is one of the key technologies of new Chinese generation launch vehicles; a high reliability design is an important guarantee for the success of launching....The reliable and intelligent propulsion pressurization system is one of the key technologies of new Chinese generation launch vehicles; a high reliability design is an important guarantee for the success of launching. This paper analyzes the domestic and overseas liquid launch vehicles in the area of propulsion pressurization systems, based on comprehensive analysis, demonstrating the reliable and intelligent propulsion pressurization system of the Long March 7(Simplified as LM-7) has been raised. By applying a full chain redundancy design, setting proper pressure control bandwidth and control mode reconstruction under extreme fault conditions, the reliability and adaptability of the propulsion pressurization system has enhanced significantly. In addition, the complete system has been verified by the first two flights of LM-7.展开更多
Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure t...Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice.展开更多
文摘The reliable and intelligent propulsion pressurization system is one of the key technologies of new Chinese generation launch vehicles; a high reliability design is an important guarantee for the success of launching. This paper analyzes the domestic and overseas liquid launch vehicles in the area of propulsion pressurization systems, based on comprehensive analysis, demonstrating the reliable and intelligent propulsion pressurization system of the Long March 7(Simplified as LM-7) has been raised. By applying a full chain redundancy design, setting proper pressure control bandwidth and control mode reconstruction under extreme fault conditions, the reliability and adaptability of the propulsion pressurization system has enhanced significantly. In addition, the complete system has been verified by the first two flights of LM-7.
基金This study was funded by Major Science and Technology Projects of Jiangxi Provincial Science and Technology Department(20152ACG70009).
文摘Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice.