Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate...Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well.展开更多
Objective:This study was to compare 5 field conformal technique to the intensity modulated radiotherapy (IMRT) 8 fields technique in boosting locally advanced cancer cervix cases after external beam radiotherapy with ...Objective:This study was to compare 5 field conformal technique to the intensity modulated radiotherapy (IMRT) 8 fields technique in boosting locally advanced cancer cervix cases after external beam radiotherapy with respect to target volume coverage and dose to normal tissues. Methods:We conducted a single institutional comparative dosimetric analysis of 10 patients with cancer cervix who was presented to radiotherapy department in National Cancer Institute, Cairo in period between June 2012 to September 2012 and received a CRT boost in the place of planned brachytherapy after large field pelvic radiotherapy (PRT) with concurrent chemotherapy were retrospectively identified. All tumors were situated in the low central pelvis. Two plans were done for every patient; one using the 8 fields IMRT and the second one using 5 fields' 3DCRT the two techniques were then compared using dose volume histogram (DVH) analysis for the PTV, bladder, rectum and both femoral heads. Results:Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both plans while it was demonstrates that the 8 fields IMRT technique carried less doses reaching OARs (rectum, bladder, both femoral heads). Conclusion:From the present study, it is concluded that IMRT technique spared more efficiently OARs than CRT technique but both techniques covered the PTV adequately so whenever possible IMRT technique should be used.展开更多
Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of tw...Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of two different treatment regimens for locally advanced nasopharyngeal carcinoma. Methods: From 2014 to 2017, 150 cases of stage III and 68 cases of stage IVA nasopharyngeal carcinoma were treated. Of these, 137 received conventional radiotherapy plus chemotherapy, and 81 received intensity-modulated radiotherapy plus chemotherapy. Chemotherapy was given either as induction, concurrent or adjuvant therapy. Survival rates were calculated according to Kaplan Meier and compared with the Log-rank test. The RTOG or EORTC criteria were used to assess acute and late toxicities. Results: The median follow-up time was 21.5 months, and the 2-year locoregional relapse-free survival, distant metastases-free survival, and overall survival rates in the conventional radiotherapy plus chemotherapy group were 76%, 71% and 77%, respectively;in the intensity-modulated radiotherapy plus chemotherapy group, they were 97%, 84%, and 100%, respectively. The difference in survival between the two groups was significant (χ<sup>2</sup> = 5.06, P = 0.028). The incidence of grade 2 and 3 xerostomia one year after radiotherapy was 45.1% and 30.9% versus 33.3% and 0%. Conclusion: Compared with conventional radiotherapy plus chemotherapy, intensity-modulated radiotherapy plus chemotherapy offers better locoregional relapse-free survival and overall survival in patients with stage III and IVA nasopharyngeal carcinoma, and may significantly reduce the occurrence of radiation-induced xerostomia.展开更多
BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent ...BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent recurrence after liver cancer resection.However,there are multiple RT techniques available,and the differ-ential effects of these techniques in preventing postoperative liver cancer re-currence require further investigation.AIM To assess the advantages and disadvantages of various adjuvant external RT methods after liver resection based on overall survival(OS)and disease-free survival(DFS)and to determine the optimal strategy.METHODS This study involved network meta-analyses and followed the PRISMA guidelines.The data of qualified studies published before July 10,2023,were collected from PubMed,Embase,the Web of Science,and the Cochrane Library.We included relevant studies on postoperative external beam RT after liver resection that had OS and DFS as the primary endpoints.The magnitudes of the effects were determined using risk ratios with 95%confidential intervals.The results were analyzed using R software and STATA software.RESULTS A total of 12 studies,including 1265 patients with hepatocellular carcinoma(HCC)after liver resection,were included in this study.There was no significant heterogeneity in the direct paired comparisons,and there were no significant differences in the inclusion or exclusion criteria,intervention measures,or outcome indicators,meeting the assumptions of heterogeneity and transitivity.OS analysis revealed that patients who underwent stereotactic body radiotherapy(SBRT)after resection had longer OS than those who underwent intensity modulated radiotherapy(IMRT)or 3-dimensional conformal RT(3D-CRT).DFS analysis revealed that patients who underwent 3D-CRT after resection had the longest DFS.Patients who underwent IMRT after resection had longer OS than those who underwent 3D-CRT and longer DFS than those who underwent SBRT.CONCLUSION HCC patients who undergo liver cancer resection must consider distinct advantages and disadvantages when choosing between SBRT and 3D-CRT.IMRT,a RT technique that is associated with longer OS than 3D-CRT and longer DFS than SBRT,may be a preferred option.展开更多
For a patient suffering from non-metastatic prostate cancer,the individualized recommendation of radiotherapy has to be the fruit of a multidisciplinary approach in the context of a Tumor Board,to be explained careful...For a patient suffering from non-metastatic prostate cancer,the individualized recommendation of radiotherapy has to be the fruit of a multidisciplinary approach in the context of a Tumor Board,to be explained carefully to the patient to obtain his informed consent.External beam radiotherapy is now delivered by intensity modulated radiotherapy,considered as the gold standard.From a radiotherapy perspective,low-risk localized prostate cancer is treated by image guided intensity modulated radiotherapy,or brachytherapy if patients meet the required eligibility criteria.Intermediate-risk patients may benefit from intensity modulated radiotherapy combined with 4e6 months of androgen deprivation therapy;intensity modulated radiotherapy alone or combined with brachytherapy can be offered to patients unsuitable for androgen deprivation therapy due to co-morbidities or unwilling to accept it to preserve their sexual health.High-risk prostate cancer,i.e.high-risk localized and locally advanced prostate cancer,requires intensity modulated radiotherapy with long-term(≥2 years)androgen deprivation therapy with luteinizing hormone releasing hormone agonists.Post-operative irradiation,either immediate or early deferred,is proposed to patients classified as pT3pN0,based on surgical margins,prostate-specific antigen values and quality of life.Whatever the techniques and their degree of sophistication,quality assurance plays a major role in the management of radiotherapy,requiring the involvement of physicians,physicists,dosimetrists,radiation technologists and computer scientists.The patients must be informed about the potential morbidity of radiotherapy and androgen deprivation therapy and followed regularly during and after treatment for tertiary prevention and evaluation.A close cooperation is needed with general practitioners and specialists to prevent and mitigate side effects and maintain quality of life.展开更多
AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC ...AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT. V20 (2A 21.49 Gy vs 7F 24.59 Gy and 9F 24.16 Gy) and V30 (2A 9.73 Gy vs 5F 12.61 Gy, 7F 11.5 Gy and 9F 11.37 Gy) of lungs in VMAT were lower than in c-IMRT, but low doses to lungs (V5 and Vl0) were increased. V30 (1A 48.12 Gy vs 5F 59.2 Gy, 7F 58.59 Gy and 9F 57.2 Gy), V40 and V50 of heart in VMAT was lower than in c-IMRT. MUs in VMAT plans were significantly reduced in comparison with c-IMRT, maximum doses to the spinal cord and mean doses of lungs were similar between the two techniques. NTCP of spinal cord was 0 for all cases. NTCP of lungs and heart in VMAT were lower than in c-IMRT. The advantage of VMAT plan was enhanced by doubling the arc. CONCLUSION: Compared with c-IMRT, VMAT, especial- ly the 2A, slightly improves the OAR dose sparing, such as lungs and heart, and reduces NTCP and MU with a better PTV coverage.展开更多
Radiation oncology is one of the three major treatment modalities to manage cancer patient cares,and is a discipline mainly driven by technology and medical devices.Modern radiation treatments have become fairly compl...Radiation oncology is one of the three major treatment modalities to manage cancer patient cares,and is a discipline mainly driven by technology and medical devices.Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing the sparing of normal organ structures.Recently,different forms of linear accelerators/radioactive source based machines have been invented and developed with the aim of providing improved treatments and more treatment options.Besides linear accelerators(Linac)that have been undergoing constant improvement and advancement and can deliver fairly complicated dose distribution patterns,imaging systems,computer information and calculation systems have been more and more integrated into radiotherapy processes.To bring radiotherapy to a potentially higher level,many institutions have either acquired or started to consider particle therapy,especially proton therapy.The complexity of modern radiotherapy demands in-depth understanding of radiation physics and machine engineering as well as computer information systems.This paper is intended to provide an introductory description of radiation oncology and related procedures,and to provide an overview of the current status of medical devices in radiotherapy in the United States of America.This paper covers the radiation delivery systems,imaging systems,treatment planning systems,record and verify systems,and QA systems.展开更多
Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing th...Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing the sparing of normal organ structures.Recently,different forms of linear accelerators/radioactive source based machines have been invented and developed with the aim of providing improved treatments and more treatment options.Besides linear accelerators(Linac)that have been undergoing constant improvement and advancement and can deliver fairly complicated dose distribution patterns,imaging systems,computer information and calculation systems have been more and more integrated into radiotherapy processes.To bring radiotherapy to a potentially higher level,many institutions have either acquired or started to consider particle therapy,especially proton therapy.The complexity of modern radiotherapy demands in-depth understanding of radiation physics and machine engineering as well as computer information systems.This paper is intended to provide an introductory description of radiation oncology and related procedures,and to provide an overview of the current status of medical devices in radiotherapy in the United States of America.This paper covers the radiation delivery systems,imaging systems,treatment planning systems,record and verify systems,and QA systems.展开更多
Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformit...Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. Methods There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd),展开更多
Background The role of internal mammary nodes (IMN) irradiation for breast cancer patients after mastectomy remains controversial. This study aimed to compare different techniques for radiation of the chest wall (C...Background The role of internal mammary nodes (IMN) irradiation for breast cancer patients after mastectomy remains controversial. This study aimed to compare different techniques for radiation of the chest wall (CW) and IMN post-mastectomy for left-breast cancer patients in terms of dose homogeneity within planning target volume (PTV) and dose to critical structures.Methods Thirty patients underwent CT simulation, while CW, IMN, left lung, heart and contralateral breast were contoured. Three three-dimensional conformal radiotherapy (3D-CRT) techniques, namely, standard tangents, partially wide tangents (PWT), and modified PWT techniques plus intensity modulated radiotherapy (IMRT) technique have been used to radiate CW and IMN. In addition to the target coverage and dose homogeneity, we also evaluated the dose to the critical structures including heart, left lung and contralateral breast.Results All three 3D-CRT techniques provided satisfactory coverage regarding total PTV. The PWT and the modified PWT gave better coverage of IMN PTV with V47.5 of (96.83±4.56)% and (95.19±3.90)% compared to standard tangents ((88.16±7.77)%), P 〈0.05. The standard tangents also contributed the biggest IMN VD105%, VD110%, VD115% and VD120%. The lowest mean dose of the heart was achieved by the modified PWT ((8.47±2.30) Gy), compared with PWT ((11.97±3.54)Gy) and standard tangents ((11.18±2.53) Gy). The mean dose of lung and contralateral breast with the modified PWT was significantly lower than those with PWT. Comparing IMRT with the modified PWT, both techniques provided satisfactory coverage. The conformity indexes (CI) with IMRT (CI1: 0.71±0.02; CI2: 0.64±0.02) were better than those with the modified PWT (CI1: 0.50±0.02; CI2: 0.45±0.02). The mean dose, V5, V10 and V5-10 of heart and left lung with the modified PWT were significantly lower than those with the IMRT. The mean dose and VD2% of contralateral breast with the modified PWT were not significantly different from the IMRT (P=0.868 and P=0.212).Conclusions No single technique provides both the best CW and IMN coverage with minimum lung and heart dose.The modified PWT technique can be used as a clinical tool for the treatment of the left-sided post-mastectomy breast cancer patients to provide homogeneous target coverage while maintaining Iow doses to normal tissue.展开更多
Aim:This study was performed to assess the extent of interfraction uterine motion during radiotherapy for cervical cancer and uterine body carcinoma while maintaining a strict bladder filling protocol.Methods:Twenty-f...Aim:This study was performed to assess the extent of interfraction uterine motion during radiotherapy for cervical cancer and uterine body carcinoma while maintaining a strict bladder filling protocol.Methods:Twenty-four patients with cervical cancer or uterine body carcinoma who were treated on a linear accelerator,were recruited.During the course of external beam radiotherapy,cone beam computed tomographic scans were taken,once at the start of treatment and then weekly until the completion of the radiotherapy course.Patients were instructed to maintain a strict bladder filling protocol.After negating the effect of patient’s setup error by offline cone beam computed tomographic imaging,the position of the uterus was defined in the clinical target volume.Then the position of the uterus was compared in the following weekly scans.The position of the uterus was also correlated with the position and the filling of the bladder.This change in uterus position was measured separately in the anterioposterior(AP),superioinferior(SI),and lateral directions.Results:According to calculations based on weekly imaging,The mean values of shift in AP,SI,and lateral directions were respectively 0.67,0.29,and 0.23 The mean extent of motion in the uterine position on a daily basis for individual patients ranged from-2.28 to+1.3 in AP,-0.56 to+0.71 in SI,and from-0.6 to+0.45 in lateral directions.Conclusion:At least once a week cone beam computed tomography might be necessary to minimize the geometrical miss and deliver the planned doses to the target tissue and normal structure provide best results with minimum toxicity by maintaining a bladder volume of about 100 mL and an empty rectum during the whole course of treatment.The daily anatomical shift and contour of the patients maintaining a bladder volume of approximately 100 mL with an empty rectum may result in asymmetrical conforming to the planning target volume and hence appropriate and adequate planning target volume margins are required.展开更多
Nasopharyngeal carcinoma is a unique cancer in the head and neck region.It has a very distinct geographic variation of incidence with more than ten times difference in incidence in high risk population compared with l...Nasopharyngeal carcinoma is a unique cancer in the head and neck region.It has a very distinct geographic variation of incidence with more than ten times difference in incidence in high risk population compared with low-risk population.No other head and neck cancer has this large worldwide variation of incidence.It remained commonest cancer in young male adults below the age of 50 in southern China.展开更多
文摘Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well.
文摘Objective:This study was to compare 5 field conformal technique to the intensity modulated radiotherapy (IMRT) 8 fields technique in boosting locally advanced cancer cervix cases after external beam radiotherapy with respect to target volume coverage and dose to normal tissues. Methods:We conducted a single institutional comparative dosimetric analysis of 10 patients with cancer cervix who was presented to radiotherapy department in National Cancer Institute, Cairo in period between June 2012 to September 2012 and received a CRT boost in the place of planned brachytherapy after large field pelvic radiotherapy (PRT) with concurrent chemotherapy were retrospectively identified. All tumors were situated in the low central pelvis. Two plans were done for every patient; one using the 8 fields IMRT and the second one using 5 fields' 3DCRT the two techniques were then compared using dose volume histogram (DVH) analysis for the PTV, bladder, rectum and both femoral heads. Results:Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both plans while it was demonstrates that the 8 fields IMRT technique carried less doses reaching OARs (rectum, bladder, both femoral heads). Conclusion:From the present study, it is concluded that IMRT technique spared more efficiently OARs than CRT technique but both techniques covered the PTV adequately so whenever possible IMRT technique should be used.
文摘Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of two different treatment regimens for locally advanced nasopharyngeal carcinoma. Methods: From 2014 to 2017, 150 cases of stage III and 68 cases of stage IVA nasopharyngeal carcinoma were treated. Of these, 137 received conventional radiotherapy plus chemotherapy, and 81 received intensity-modulated radiotherapy plus chemotherapy. Chemotherapy was given either as induction, concurrent or adjuvant therapy. Survival rates were calculated according to Kaplan Meier and compared with the Log-rank test. The RTOG or EORTC criteria were used to assess acute and late toxicities. Results: The median follow-up time was 21.5 months, and the 2-year locoregional relapse-free survival, distant metastases-free survival, and overall survival rates in the conventional radiotherapy plus chemotherapy group were 76%, 71% and 77%, respectively;in the intensity-modulated radiotherapy plus chemotherapy group, they were 97%, 84%, and 100%, respectively. The difference in survival between the two groups was significant (χ<sup>2</sup> = 5.06, P = 0.028). The incidence of grade 2 and 3 xerostomia one year after radiotherapy was 45.1% and 30.9% versus 33.3% and 0%. Conclusion: Compared with conventional radiotherapy plus chemotherapy, intensity-modulated radiotherapy plus chemotherapy offers better locoregional relapse-free survival and overall survival in patients with stage III and IVA nasopharyngeal carcinoma, and may significantly reduce the occurrence of radiation-induced xerostomia.
基金Supported by The Science and Technology Plan Project of Guangzhou,No.202102010171National Natural Science Foundation。
文摘BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent recurrence after liver cancer resection.However,there are multiple RT techniques available,and the differ-ential effects of these techniques in preventing postoperative liver cancer re-currence require further investigation.AIM To assess the advantages and disadvantages of various adjuvant external RT methods after liver resection based on overall survival(OS)and disease-free survival(DFS)and to determine the optimal strategy.METHODS This study involved network meta-analyses and followed the PRISMA guidelines.The data of qualified studies published before July 10,2023,were collected from PubMed,Embase,the Web of Science,and the Cochrane Library.We included relevant studies on postoperative external beam RT after liver resection that had OS and DFS as the primary endpoints.The magnitudes of the effects were determined using risk ratios with 95%confidential intervals.The results were analyzed using R software and STATA software.RESULTS A total of 12 studies,including 1265 patients with hepatocellular carcinoma(HCC)after liver resection,were included in this study.There was no significant heterogeneity in the direct paired comparisons,and there were no significant differences in the inclusion or exclusion criteria,intervention measures,or outcome indicators,meeting the assumptions of heterogeneity and transitivity.OS analysis revealed that patients who underwent stereotactic body radiotherapy(SBRT)after resection had longer OS than those who underwent intensity modulated radiotherapy(IMRT)or 3-dimensional conformal RT(3D-CRT).DFS analysis revealed that patients who underwent 3D-CRT after resection had the longest DFS.Patients who underwent IMRT after resection had longer OS than those who underwent 3D-CRT and longer DFS than those who underwent SBRT.CONCLUSION HCC patients who undergo liver cancer resection must consider distinct advantages and disadvantages when choosing between SBRT and 3D-CRT.IMRT,a RT technique that is associated with longer OS than 3D-CRT and longer DFS than SBRT,may be a preferred option.
文摘For a patient suffering from non-metastatic prostate cancer,the individualized recommendation of radiotherapy has to be the fruit of a multidisciplinary approach in the context of a Tumor Board,to be explained carefully to the patient to obtain his informed consent.External beam radiotherapy is now delivered by intensity modulated radiotherapy,considered as the gold standard.From a radiotherapy perspective,low-risk localized prostate cancer is treated by image guided intensity modulated radiotherapy,or brachytherapy if patients meet the required eligibility criteria.Intermediate-risk patients may benefit from intensity modulated radiotherapy combined with 4e6 months of androgen deprivation therapy;intensity modulated radiotherapy alone or combined with brachytherapy can be offered to patients unsuitable for androgen deprivation therapy due to co-morbidities or unwilling to accept it to preserve their sexual health.High-risk prostate cancer,i.e.high-risk localized and locally advanced prostate cancer,requires intensity modulated radiotherapy with long-term(≥2 years)androgen deprivation therapy with luteinizing hormone releasing hormone agonists.Post-operative irradiation,either immediate or early deferred,is proposed to patients classified as pT3pN0,based on surgical margins,prostate-specific antigen values and quality of life.Whatever the techniques and their degree of sophistication,quality assurance plays a major role in the management of radiotherapy,requiring the involvement of physicians,physicists,dosimetrists,radiation technologists and computer scientists.The patients must be informed about the potential morbidity of radiotherapy and androgen deprivation therapy and followed regularly during and after treatment for tertiary prevention and evaluation.A close cooperation is needed with general practitioners and specialists to prevent and mitigate side effects and maintain quality of life.
基金Supported by The National Natural Science Foundation of China, No. 30870738
文摘AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT. V20 (2A 21.49 Gy vs 7F 24.59 Gy and 9F 24.16 Gy) and V30 (2A 9.73 Gy vs 5F 12.61 Gy, 7F 11.5 Gy and 9F 11.37 Gy) of lungs in VMAT were lower than in c-IMRT, but low doses to lungs (V5 and Vl0) were increased. V30 (1A 48.12 Gy vs 5F 59.2 Gy, 7F 58.59 Gy and 9F 57.2 Gy), V40 and V50 of heart in VMAT was lower than in c-IMRT. MUs in VMAT plans were significantly reduced in comparison with c-IMRT, maximum doses to the spinal cord and mean doses of lungs were similar between the two techniques. NTCP of spinal cord was 0 for all cases. NTCP of lungs and heart in VMAT were lower than in c-IMRT. The advantage of VMAT plan was enhanced by doubling the arc. CONCLUSION: Compared with c-IMRT, VMAT, especial- ly the 2A, slightly improves the OAR dose sparing, such as lungs and heart, and reduces NTCP and MU with a better PTV coverage.
文摘Radiation oncology is one of the three major treatment modalities to manage cancer patient cares,and is a discipline mainly driven by technology and medical devices.Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing the sparing of normal organ structures.Recently,different forms of linear accelerators/radioactive source based machines have been invented and developed with the aim of providing improved treatments and more treatment options.Besides linear accelerators(Linac)that have been undergoing constant improvement and advancement and can deliver fairly complicated dose distribution patterns,imaging systems,computer information and calculation systems have been more and more integrated into radiotherapy processes.To bring radiotherapy to a potentially higher level,many institutions have either acquired or started to consider particle therapy,especially proton therapy.The complexity of modern radiotherapy demands in-depth understanding of radiation physics and machine engineering as well as computer information systems.This paper is intended to provide an introductory description of radiation oncology and related procedures,and to provide an overview of the current status of medical devices in radiotherapy in the United States of America.This paper covers the radiation delivery systems,imaging systems,treatment planning systems,record and verify systems,and QA systems.
文摘Modern radiation treatments have become fairly complex and involve in utilizing a variety of medical devices to achieve the goal of providing conformal radiation dose coverage to the tumor target(s)while maximizing the sparing of normal organ structures.Recently,different forms of linear accelerators/radioactive source based machines have been invented and developed with the aim of providing improved treatments and more treatment options.Besides linear accelerators(Linac)that have been undergoing constant improvement and advancement and can deliver fairly complicated dose distribution patterns,imaging systems,computer information and calculation systems have been more and more integrated into radiotherapy processes.To bring radiotherapy to a potentially higher level,many institutions have either acquired or started to consider particle therapy,especially proton therapy.The complexity of modern radiotherapy demands in-depth understanding of radiation physics and machine engineering as well as computer information systems.This paper is intended to provide an introductory description of radiation oncology and related procedures,and to provide an overview of the current status of medical devices in radiotherapy in the United States of America.This paper covers the radiation delivery systems,imaging systems,treatment planning systems,record and verify systems,and QA systems.
文摘Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. Methods There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd),
文摘Background The role of internal mammary nodes (IMN) irradiation for breast cancer patients after mastectomy remains controversial. This study aimed to compare different techniques for radiation of the chest wall (CW) and IMN post-mastectomy for left-breast cancer patients in terms of dose homogeneity within planning target volume (PTV) and dose to critical structures.Methods Thirty patients underwent CT simulation, while CW, IMN, left lung, heart and contralateral breast were contoured. Three three-dimensional conformal radiotherapy (3D-CRT) techniques, namely, standard tangents, partially wide tangents (PWT), and modified PWT techniques plus intensity modulated radiotherapy (IMRT) technique have been used to radiate CW and IMN. In addition to the target coverage and dose homogeneity, we also evaluated the dose to the critical structures including heart, left lung and contralateral breast.Results All three 3D-CRT techniques provided satisfactory coverage regarding total PTV. The PWT and the modified PWT gave better coverage of IMN PTV with V47.5 of (96.83±4.56)% and (95.19±3.90)% compared to standard tangents ((88.16±7.77)%), P 〈0.05. The standard tangents also contributed the biggest IMN VD105%, VD110%, VD115% and VD120%. The lowest mean dose of the heart was achieved by the modified PWT ((8.47±2.30) Gy), compared with PWT ((11.97±3.54)Gy) and standard tangents ((11.18±2.53) Gy). The mean dose of lung and contralateral breast with the modified PWT was significantly lower than those with PWT. Comparing IMRT with the modified PWT, both techniques provided satisfactory coverage. The conformity indexes (CI) with IMRT (CI1: 0.71±0.02; CI2: 0.64±0.02) were better than those with the modified PWT (CI1: 0.50±0.02; CI2: 0.45±0.02). The mean dose, V5, V10 and V5-10 of heart and left lung with the modified PWT were significantly lower than those with the IMRT. The mean dose and VD2% of contralateral breast with the modified PWT were not significantly different from the IMRT (P=0.868 and P=0.212).Conclusions No single technique provides both the best CW and IMN coverage with minimum lung and heart dose.The modified PWT technique can be used as a clinical tool for the treatment of the left-sided post-mastectomy breast cancer patients to provide homogeneous target coverage while maintaining Iow doses to normal tissue.
文摘Aim:This study was performed to assess the extent of interfraction uterine motion during radiotherapy for cervical cancer and uterine body carcinoma while maintaining a strict bladder filling protocol.Methods:Twenty-four patients with cervical cancer or uterine body carcinoma who were treated on a linear accelerator,were recruited.During the course of external beam radiotherapy,cone beam computed tomographic scans were taken,once at the start of treatment and then weekly until the completion of the radiotherapy course.Patients were instructed to maintain a strict bladder filling protocol.After negating the effect of patient’s setup error by offline cone beam computed tomographic imaging,the position of the uterus was defined in the clinical target volume.Then the position of the uterus was compared in the following weekly scans.The position of the uterus was also correlated with the position and the filling of the bladder.This change in uterus position was measured separately in the anterioposterior(AP),superioinferior(SI),and lateral directions.Results:According to calculations based on weekly imaging,The mean values of shift in AP,SI,and lateral directions were respectively 0.67,0.29,and 0.23 The mean extent of motion in the uterine position on a daily basis for individual patients ranged from-2.28 to+1.3 in AP,-0.56 to+0.71 in SI,and from-0.6 to+0.45 in lateral directions.Conclusion:At least once a week cone beam computed tomography might be necessary to minimize the geometrical miss and deliver the planned doses to the target tissue and normal structure provide best results with minimum toxicity by maintaining a bladder volume of about 100 mL and an empty rectum during the whole course of treatment.The daily anatomical shift and contour of the patients maintaining a bladder volume of approximately 100 mL with an empty rectum may result in asymmetrical conforming to the planning target volume and hence appropriate and adequate planning target volume margins are required.
文摘Nasopharyngeal carcinoma is a unique cancer in the head and neck region.It has a very distinct geographic variation of incidence with more than ten times difference in incidence in high risk population compared with low-risk population.No other head and neck cancer has this large worldwide variation of incidence.It remained commonest cancer in young male adults below the age of 50 in southern China.