期刊文献+
共找到188,956篇文章
< 1 2 250 >
每页显示 20 50 100
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
1
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Clinical Outcome of Internal Fixation and Fusion in the Treatment of Spinal Fractures by Paraspinal Muscular Space Approach
2
作者 Yafei Zhao Qiushuang Ma +3 位作者 Meng Zhang Shengwang Li Yannan Li Chenguang Tian 《Journal of Clinical and Nursing Research》 2024年第7期10-15,共6页
Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Ho... Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Hospital of TCM from October 2022 to April 2024 were selected as the study subjects and were randomly divided into the control group(n=52)and the observation group(n=52)according to the random number table method.The control group was treated with the conventional approach of internal fixation surgery,and the observation group was treated with the paraspinal muscular interspace approach of internal fixation fusion.The two groups’general data,surgical indexes,pain,lumbar spine function,and postoperative complications were observed.Results:The baseline data of the two groups of patients were not statistically significant(all P>0.05)while the intraoperative bleeding,the first postoperative time getting up from bed,and the length of hospital stay of the patients in the observation group were shorter than that of the control group(all P=0.000<0.001),and the duration of the operation was longer than that of the control group(t=2.644,P=0.010<0.05);at 3 months postoperatively,the VAS scores of the patients in the observation group were significantly lower than those in the control group(t=10.768,P=0.000<0.001),and the JOA score was higher than that of the control group(t=6.498,P=0.000<0.001);the total complication rate of patients in the observation group(3/5.77%)was significantly lower than that of the control group(12/23.08%)(χ^(2)=6.310,P=0.012<0.05).Conclusion:In the treatment of spinal fracture patients,compared with the conventional approach to internal fixation surgery,the paraspinal muscular gap approach to internal fixation and fusion treatment is less traumatic,postoperative lumbar spine function recovery is faster,and can reduce the incidence of postoperative complications. 展开更多
关键词 Paraspinal muscular interspace approach fixation and fusion Spinal fracture
下载PDF
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
3
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Mechanism of internal thermal runaway propagation in blade batteries 被引量:3
4
作者 Xuning Feng Fangshu Zhang +3 位作者 Wensheng Huang Yong Peng Chengshan Xu Minggao Ouyang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第2期184-194,I0005,共12页
Blade batteries are extensively used in electric vehicles,but unavoidable thermal runaway is an inherent threat to their safe use.This study experimentally investigated the mechanism underlying thermal runaway propaga... Blade batteries are extensively used in electric vehicles,but unavoidable thermal runaway is an inherent threat to their safe use.This study experimentally investigated the mechanism underlying thermal runaway propagation within a blade battery by using a nail to trigger thermal runaway and thermocouples to track its propagation inside a cell.The results showed that the internal thermal runaway could propagate for up to 272 s,which is comparable to that of a traditional battery module.The velocity of the thermal runaway propagation fluctuated between 1 and 8 mm s^(-1),depending on both the electrolyte content and high-temperature gas diffusion.In the early stages of thermal runaway,the electrolyte participated in the reaction,which intensified the thermal runaway and accelerated its propagation.As the battery temperature increased,the electrolyte evaporated,which attenuated the acceleration effect.Gas diffusion affected thermal runaway propagation through both heat transfer and mass transfer.The experimental results indicated that gas diffusion accelerated the velocity of thermal runaway propagation by 36.84%.We used a 1D mathematical model and confirmed that convective heat transfer induced by gas diffusion increased the velocity of thermal runaway propagation by 5.46%-17.06%.Finally,the temperature rate curve was analyzed,and a three-stage mechanism for internal thermal runaway propagation was proposed.In Stage I,convective heat transfer from electrolyte evaporation locally increased the temperature to 100℃.In Stage II,solid heat transfer locally increases the temperature to trigger thermal runaway.In StageⅢ,thermal runaway sharply increases the local temperature.The proposed mechanism sheds light on the internal thermal runaway propagation of blade batteries and offers valuable insights into safety considerations for future design. 展开更多
关键词 Lithium-ion battery Blade battery Thermal runaway internal thermal runaway propagation
下载PDF
Microfluidic-oriented synthesis of enriched iridium nanodots/carbon architecture for robust electrocatalytic nitrogen fixation 被引量:1
5
作者 Hengyuan Liu Xingjiang Wu +2 位作者 Yuhao Geng Xin Li Jianhong Xu 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第3期544-555,共12页
Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-... Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-products.However,the chemical inertness of nitrogen and poor activated capacity on catalyst surface usually produce low ammonia yield and faradic efficiency.Herein,the microfluidic technology is proposed to efficiently fabricate enriched iridium nanodots/carbon architecture.Owing to in-situ co-precipitation reaction and microfluidic manipulation,the iridium nanodots/carbon nanomaterials possess small average size,uniform dispersion,high conductivity and abundant active sites,producing good proton activation and rapid electrons transmission and moderate adsorption/desorption capacity.As a result,the as-prepared iridium nanodots/carbon nanomaterials realize large ammonia yield of 28.73 μg h^(-1) cm^(-2) and faradic efficiency of 9.14%in KOH solution.Moreover,the high ammonia yield of 11.21 μg h^(-1) cm^(-2) and faradic efficiency of 24.30%are also achieved in H_(2)SO_(4) solution.The microfluidic method provides a reference for large-scale fabrication of nano-sized catalyst materials,which may accelerate the progress of electrocatalytic NRR in industrialization field. 展开更多
关键词 Iridium nanodots CARBON Microfluidic technology Efficient synthesis Electrocatalytic nitrogen fixation
下载PDF
Endoscopic polidocanol foam sclerobanding for the treatment of grade Ⅱ-Ⅲ internal hemorrhoids:A prospective,multi-center,randomized study 被引量:2
6
作者 Chun-Ying Qu Fei-Yu Zhang +10 位作者 Yi Zhang Ming-Ming Li Zheng-Hong Li Mei-Hong Cai Lei-Ming Xu Feng Shen Wen Wang Wu-Lian Lin Feng-Yu Gao Hao Zhang Guang-Yu Chen 《World Journal of Gastroenterology》 SCIE CAS 2024年第27期3326-3335,共10页
BACKGROUND Endoscopic rubber band ligation(ERBL)is a nonsurgical technique for the treatment of symptomatic internal hemorrhoids but is limited by recurrence and post-procedural pain.AIM To evaluate satisfaction,long-... BACKGROUND Endoscopic rubber band ligation(ERBL)is a nonsurgical technique for the treatment of symptomatic internal hemorrhoids but is limited by recurrence and post-procedural pain.AIM To evaluate satisfaction,long-term recurrence,and post-procedural pain in managing internal hemorrhoids using a combination of polidocanol foam sclerotherapy and ERBL.METHODS This was a prospective,multicenter,randomized study.A total of 195 consecutive patients diagnosed with grade II-III internal hemorrhoids were enrolled from four tertiary hospitals and randomly divided into a cap-assisted endoscopic polidocanol foam sclerobanding(EFSB)or an ERBL group.All patients were followed-up for 12 months.Symptom-based severity and post-procedural pain were assessed using a hemorrhoid severity score(HSS)and a visual analog scale(VAS).Continuous variables were reported as medians and interquartile range.RESULTS One hundred and ninety-five patients were enrolled,with 98 in the EFSB group.HSS was lower in the EFSB group than in the ERBL group at 8 weeks[4.0(3.0-5.0)vs 5.0(4.0-6.0),P=0.003]and 12-month[2.0(1.0-3.0)vs 3.0(2.0-3.0),P<0.001]of follow-up.The prolapse recurrence rate was lower in the EFSB group at 12 months(11.2%vs 21.6%,P=0.038).Multiple linear regression analysis demonstrated that EFSB treatment[B=-0.915,95%confidence interval(CI):−1.301 to−0.530,P=0.001]and rubber band number(B=0.843,95%CI:0.595-1.092,P<0.001)were negatively and independently associated with the VAS score 24 hours post-procedure.The median VAS was lower in the EFSB group than in the ERBL[2.0(1.0-3.0)vs 3.0(2.0-4.0),P<0.001].CONCLUSION Cap-assisted EFSB provided long-term satisfaction and effective relief from the recurrence of prolapse and pain 24 hours post-procedure. 展开更多
关键词 internal hemorrhoids Endoscopic therapy Polidocanol foam SCLEROTHERAPY Rubber band ligation Sclerobanding
下载PDF
Increased dependence on nitrogen-fixation of a native legume in competition with an invasive plant 被引量:1
7
作者 Meixu Han Haiyang Zhang +12 位作者 Mingchao Liu Jinqi Tang Xiaocheng Guo Weizheng Ren Yong Zhao Qingpei Yang Binglin Guo Qinwen Han Yulong Feng Zhipei Feng Honghui Wu Xitian Yang Deliang Kong 《Plant Diversity》 SCIE CAS CSCD 2024年第4期510-518,共9页
Suppression of roots and/or their symbiotic microorganisms,such as mycorrhizal fungi and rhizobia,is an effective way for alien plants to outcompete native plants.However,little is known about how invasive and native ... Suppression of roots and/or their symbiotic microorganisms,such as mycorrhizal fungi and rhizobia,is an effective way for alien plants to outcompete native plants.However,little is known about how invasive and native plants interact with the quantity and activity of nutrient-acquisition agents.Here a pot experiment was conducted with monoculture and mixed plantings of an invasive plant,Xanthium strumarium,and a common native legume,Glycine max.We measured traits related to root and nodule quantity and activity and mycorrhizal colonization.Compared to the monoculture,fine root quantity(biomass,surface area)and activity(root nitrogen(N)concentration,acid phosphatase activity)of G.max decreased in mixed plantings;nodule quantity(biomass)decreased by 45%,while nodule activity in Nfixing via rhizobium increased by 106%;mycorrhizal colonization was unaffected.Contribution of N fixation to leaf N content in G.max increased in the mixed plantings,and this increase was attributed to a decrease in the rhizosphere soil N of G.max in the mixed plantings.Increased root quantity and activity,along with a higher mycorrhizal association was observed in X.strumarium in the mixed compared to monoculture.Together,the invasive plant did not directly scavenge N from nodule-fixed N,but rather depleted the rhizosphere soil N of the legume,thereby stimulating the activity of N-fixation and increasing the dependence of the native legume on this N source.The quantity-activity framework holds promise for future studies on how native legumes respond to alien plant invasions. 展开更多
关键词 Mycorrhizal strategy Nitrogen depletion Plant invasion Root nutrient acquisition strategy Symbiotic nitrogen fixation
下载PDF
Flow Regimes in Bubble Columns with and without Internals: A Review 被引量:1
8
作者 Ayat N.Mahmood Amer A.Abdulrahman +3 位作者 Laith S.Sabri Abbas J.Sultan Hasan Shakir Majdi Muthanna H.Al-Dahhan 《Fluid Dynamics & Materials Processing》 EI 2024年第2期239-256,共18页
Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflo... Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflow regimes established in bubble columns.Some effort is also provided to introduce relevant definitions pertaining to thisfield,namely,that of“void fraction”and related(local,chordal,cross-sectional and volumetric)variants.Experimental studies involving different parameters that affect design and operating conditions are also discussed in detail.In the second part of the review,the attention is shifted to cases with internals of various types(perfo-rated plates,baffles,vibrating helical springs,mixers,and heat exchanger tubes)immersed in the bubble columns.It is shown that the presence of these elements has a limited influence on the global column hydrodynamics.However,they can make the homogeneousflow regime more stable in terms of transition gas velocity and transi-tion holdup value.The last section is used to highlight gaps which have not beenfilled yet and future directions of investigation. 展开更多
关键词 HYDRODYNAMICS flow regime bubble column heat-exchanging internals
下载PDF
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation 被引量:2
9
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 Point-of-care ultrasound Bedside ultrasound internal jugular vein Right atrial pressure Central venous pressure
下载PDF
Suppressed Internal Intrinsic Stress Engineering in High-Performance Ni-Rich Cathode Via Multi layered In Situ Coating Structure 被引量:1
10
作者 Jiachao Yang Yunjiao Li +3 位作者 Xiaoming Xi Junchao Zheng Jian Yu Zhenjiang He 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第2期58-66,共9页
LiNi_(x)Co_(y)Al_(z)O_(2)(NCA)cathode materials are drawing widespread attention,but the huge gap between the ideal and present cyclic stability still hinders their further commercial application,especially for the Ni... LiNi_(x)Co_(y)Al_(z)O_(2)(NCA)cathode materials are drawing widespread attention,but the huge gap between the ideal and present cyclic stability still hinders their further commercial application,especially for the Ni-rich LiNi_(x)Co_(y)Al_(z)O_(2)(x>0.8,x+y+z=1)cathode material,which is owing to the structural degradation and particles'intrinsic fracture.To tackle the problems,Li_(0.5)La_(2)Al_(0.5)O_(4)in situ coated and Mn compensating doped multilayer LiNi_(0.82)Co_(0.14)Al_(0.04)O_(2)was prepared.XRD refinement indicates that La-Mn co-modifying could realize appropriate Li/Ni disorder degree.Calculated results and in situ XRD patterns reveal that the LLAO coating layer could effectively restrain crack in secondary particles benefited from the suppressed internal strain.AFM further improves as NCA-LM2 has superior mechanical property.The SEM,TEM,XPS tests indicate that the cycled cathode with LLAO-Mn modification displays a more complete morphology and less side reaction with electrolyte.DEMS was used to further investigate cathode-electrolyte interface which was reflected by gas evolution.NCA-LM2 releases less CO_(2)than NCA-P indexing on a more stable surface.The modified material presents outstanding capacity retention of 96.2%after 100 cycles in the voltage range of 3.0-4.4 V at 1C,13%higher than that of the pristine and 80.8%at 1 C after 300 cycles.This excellent electrochemical performance could be attributed to the fact that the high chemically stable coating layer of Li_(0.5)La_(2)Al_(0.5)O_(4)(LLAO)could enhance the interface and the Mn doping layer could suppress the influence of the lattice mismatch and distortion.We believe that it can be a useful strategy for the modification of Ni-rich cathode material and other advanced functional material. 展开更多
关键词 compensating doped in situ coating multilayer material Ni-rich cathode materials suppressed internal strain
下载PDF
Selective internal radiation therapy segmentectomy:A new minimally invasive curative option for primary liver malignancies? 被引量:1
11
作者 Riccardo Inchingolo Francesco Cortese +5 位作者 Antonio Rosario Pisani Fabrizio Acquafredda Roberto Calbi Riccardo Memeo Fotis Anagnostopoulos Stavros Spiliopoulos 《World Journal of Gastroenterology》 SCIE CAS 2024年第18期2379-2386,共8页
Transarterial radioembolization or selective internal radiation therapy(SIRT)has emerged as a minimally invasive approach for the treatment of tumors.This percutaneous technique involves the local,intra-arterial deliv... Transarterial radioembolization or selective internal radiation therapy(SIRT)has emerged as a minimally invasive approach for the treatment of tumors.This percutaneous technique involves the local,intra-arterial delivery of radioactive microspheres directly into the tumor.Historically employed as a palliative measure for liver malignancies,SIRT has gained traction over the past decade as a potential curative option,mirroring the increasing role of radiation segmentectomy.The latest update of the BCLC hepatocellular carcinoma guidelines recognizes SIRT as an effective treatment modality comparable to other local ablative methods,particularly well-suited for patients where surgical resection or ablation is not feasible.Radiation segmentectomy is a more selective approach,aiming to deliver high-dose radiation to one to three specific hepatic segments,while minimizing damage to surrounding healthy tissue.Future research efforts in radiation segmentectomy should prioritize optimizing radiation dosimetry and refining the technique for super-selective administration of radiospheres within the designated hepatic segments. 展开更多
关键词 Transarterial radioembolization Selective internal radiation therapy Radiation segmentectomy Hepatocellular carcinoma Primary liver malignancies Personalised dosimetry
下载PDF
Relative Impacts of Sea Ice Loss and Atmospheric Internal Variability on the Winter Arctic to East Asian Surface Air Temperature Based on Large-Ensemble Simulations with NorESM2 被引量:1
12
作者 Shengping HE Helge DRANGE +4 位作者 Tore FUREVIK Huijun WANG Ke FAN Lise Seland GRAFF Yvan J.ORSOLINI 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第8期1511-1526,共16页
To quantify the relative contributions of Arctic sea ice and unforced atmospheric internal variability to the “warm Arctic, cold East Asia”(WACE) teleconnection, this study analyses three sets of large-ensemble simu... To quantify the relative contributions of Arctic sea ice and unforced atmospheric internal variability to the “warm Arctic, cold East Asia”(WACE) teleconnection, this study analyses three sets of large-ensemble simulations carried out by the Norwegian Earth System Model with a coupled atmosphere–land surface model, forced by seasonal sea ice conditions from preindustrial, present-day, and future periods. Each ensemble member within the same set uses the same forcing but with small perturbations to the atmospheric initial state. Hence, the difference between the present-day(or future) ensemble mean and the preindustrial ensemble mean provides the ice-loss-induced response, while the difference of the individual members within the present-day(or future) set is the effect of atmospheric internal variability. Results indicate that both present-day and future sea ice loss can force a negative phase of the Arctic Oscillation with a WACE pattern in winter. The magnitude of ice-induced Arctic warming is over four(ten) times larger than the ice-induced East Asian cooling in the present-day(future) experiment;the latter having a magnitude that is about 30% of the observed cooling. Sea ice loss contributes about 60%(80%) to the Arctic winter warming in the present-day(future) experiment. Atmospheric internal variability can also induce a WACE pattern with comparable magnitudes between the Arctic and East Asia. Ice-lossinduced East Asian cooling can easily be masked by atmospheric internal variability effects because random atmospheric internal variability may induce a larger magnitude warming. The observed WACE pattern occurs as a result of both Arctic sea ice loss and atmospheric internal variability, with the former dominating Arctic warming and the latter dominating East Asian cooling. 展开更多
关键词 Arctic sea ice loss warm Arctic–cold East Asia atmospheric internal variability large-ensemble simulation NorESM2 PAMIP
下载PDF
Adaptive Optimal Discrete-Time Output-Feedback Using an Internal Model Principle and Adaptive Dynamic Programming 被引量:1
13
作者 Zhongyang Wang Youqing Wang Zdzisław Kowalczuk 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第1期131-140,共10页
In order to address the output feedback issue for linear discrete-time systems, this work suggests a brand-new adaptive dynamic programming(ADP) technique based on the internal model principle(IMP). The proposed metho... In order to address the output feedback issue for linear discrete-time systems, this work suggests a brand-new adaptive dynamic programming(ADP) technique based on the internal model principle(IMP). The proposed method, termed as IMP-ADP, does not require complete state feedback-merely the measurement of input and output data. More specifically, based on the IMP, the output control problem can first be converted into a stabilization problem. We then design an observer to reproduce the full state of the system by measuring the inputs and outputs. Moreover, this technique includes both a policy iteration algorithm and a value iteration algorithm to determine the optimal feedback gain without using a dynamic system model. It is important that with this concept one does not need to solve the regulator equation. Finally, this control method was tested on an inverter system of grid-connected LCLs to demonstrate that the proposed method provides the desired performance in terms of both tracking and disturbance rejection. 展开更多
关键词 Adaptive dynamic programming(ADP) internal model principle(IMP) output feedback problem policy iteration(PI) value iteration(VI)
下载PDF
Internal fixator vs external fixator in the management of unstable pelvic ring injuries:A prospective comparative cohort study 被引量:1
14
作者 Mohamed Abo-Elsoud Mostafa I Awad +2 位作者 Mahmoud Abdel Karim Sherif Khaled Mohamed Abdelmoneim 《World Journal of Orthopedics》 2023年第7期562-571,共10页
BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using e... BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures. 展开更多
关键词 internal fixator External fixator UNSTABLE ANTERIOR PELVIC INJURIES
下载PDF
Sustainable nitrogen fixation by bubble discharge plasma:Performance optimization and mechanism
15
作者 Yuankun Ye Xiaoyang Wei +2 位作者 Li Zhang Sen Wang Zhi Fang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第11期692-701,共10页
Sustainable nitrogen fixation driven by renewable energy sources under mild conditions has been widely sought to replace the industrial Haber-Bosch process.The fixation of nitrogen in the form of NO_(x)^(-)and NH_4^(+... Sustainable nitrogen fixation driven by renewable energy sources under mild conditions has been widely sought to replace the industrial Haber-Bosch process.The fixation of nitrogen in the form of NO_(x)^(-)and NH_4^(+)into aqueous solutions using electricity-driven gas-liquid discharge plasma is considered a promising prescription.In this paper,a scalable bubble discharge excited by nanosecond pulse power is employed for nitrogen fixation in the liquid phase.The nitrogen fixation performance and the mechanisms are analyzed by varying the power supply parameters,working gas flow rate and composition.The results show that an increase in voltage and frequency can result in an enhanced NO_(3)^(-)yield.Increases in the gas flow rate can result in inadequate activation of the working gas,which together with more inefficient mass transfer efficiencies can reduce the yield.The addition of O_(2) effectively elevates NO_(3)^(-)production while simultaneously inhibiting NH_4^(+) production.The addition of H_(2)O vapor increases the production of OH and H,thereby promoting the generation of reactive nitrogen and enhancing the yield of nitrogen fixation.However,the excessive addition of O_(2) and H_(2)O vapor results in negative effect on the yield of nitrogen fixation,due to the significant weakening of the discharge intensity.The optimal nitrogen fixation yield was up to 16.5 μmol/min,while the optimal energy consumption was approximately 21.3 MJ/mol in this study.Finally,the mechanism related to nitrogen fixation is discussed through the optical emission spectral(OES) information in conjunction with the simulation of energy loss paths in the plasma by BOLSIG+.The work advances knowledge of the effect of parameter variations on nitrogen fixation by gas-liquid discharge for higher yield and energy production. 展开更多
关键词 Nitrogen fixation Gas-liquid discharge plasma Bubble discharge MECHANISM
下载PDF
Intermittent sliding-lock-knot suture for limbal conjunctival autograft fixation in pterygium surgery:a technique note
16
作者 Ling Zhang Run-Hua Lyu +3 位作者 Jing-Ru Wang Wen-Jian Shi Feng Zheng Ying-Ying Gao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期838-844,共7页
AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive p... AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive patients with primary pterygium who had undergone pterygium excision combined with limbal conjunctival autograft transplantation between March 2021 and March 2022 at our institute were retrospectively analyzed.Primary outcome measures were mean duration of surgery and suture removal,degree of conjunctival hyperemia on postoperative day 1,pain score at suture removal,postoperative symptoms at 6mo,including conjunctival hyperemia,foreign body sensation,and graft stability.RESULTS:Ninety-eight patients underwent monocular surgery and were divided into ISLK(51 eyes)and RI(47 eyes)groups according to the type of conjunctiva autograft fixation method planned.There was no significant difference in mean duration of surgery between the two groups(18.59±2.39min vs 18.15±2.20min,P=0.417);however,compared to the RI group,shorter suture removal times were observed in the ISLK group[0.58min(0.42-0.87)vs 3.00min(2.21-4.15),P<0.001].The degree of conjunctival hyperemia on postoperative day 1 was milder in the ISLK group(P<0.001).Pain scores at suture removal were lower in the ISLK group than in RI group[1(0-3)vs 2(1-4),P<0.001].Postoperative symptoms at 6mo were comparable between the groups(P=0.487),with no recurrence.CONCLUSION:ISLK is an innovative method for limbal conjunctival autograft fixation after pterygium excision.Compared to RI fixation,ISLK facilitates suture removal and reduces discomfort,with comparable surgery duration and less conjunctival hyperemia. 展开更多
关键词 intermittent sliding-lock-knot fixation pterygium suture removal
下载PDF
Plasma nitrogen fixation system with dual-loop enhancement for improved energy efficiency and its efficacy for lettuce cultivation
17
作者 韩泽阳 张梦雪 +8 位作者 张頔 何欣 井天军 葛知轩 李玉鸽 朱童 任云鸿 仲崇山 季方 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期82-92,共11页
Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this ... Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this work,we present the development of a compact and automatic PNF system for on-site agricultural applications.The system utilized a gliding-arc discharge as the plasma source and employed a dual-loop design to generate NO_(x)from air and water under atmospheric conditions.Experimental results showed that the system with a dualloop design performs well in terms of energy costs and production rates.Optimal operational parameters for the system were determined through experimentation,resulting in an energy cost of 13.9 MJ mol^(-1)and an energy efficiency of 16 g kWh^(-1)for NO_(3)^(-)production,respectively.Moreover,the concentration of exhausted NO_(x)was below the emission standards.Soilless lettuce cultivation experiments demonstrated that NO_(x)^(-)produced by the PNF system could serve as liquid nitrate nitrogen fertilizer.Overall,our work demonstrates the potential of the developed PNF system for on-site application in the production of green-leaf vegetables. 展开更多
关键词 plasma nitrogen fixation gliding arc soilless cultivation LETTUCE
下载PDF
Correction to:Error Calculation of Large-Amplitude Internal Solitary Waves Within the Pycnocline Introduced by the Strong Stratification Approximation
18
作者 Cunguo Xu Zhan Wang Masoud Hayatdavoodi 《哈尔滨工程大学学报(英文版)》 CSCD 2024年第1期247-247,共1页
In the original publication the third author name is published incorrectly as“Hayatdavoodi Masoud”.The correct author name should be read as“Masoud Hayatdavoodi”.The correct author name is available in this correc... In the original publication the third author name is published incorrectly as“Hayatdavoodi Masoud”.The correct author name should be read as“Masoud Hayatdavoodi”.The correct author name is available in this correction. 展开更多
关键词 STRONG internal CORRECTION
下载PDF
In vitro performance of a biodegradable zinc alloy adjustable-loop cortical suspension fixation for anterior cruciate ligament reconstruction
19
作者 Ting Wang Zhangzhi Shi +7 位作者 Hongyong Zhong Xiangmin Li Jinling Sun Wei Yin Xiaojing Ji Qiang Wang Anqi Zhao Luning Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期887-898,共12页
Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,part... Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,particularly those made from conventional steel or titanium alloys.In this study,a biodegradable Zn-0.45Mn-0.2Mg(ZMM42)alloy with the yield strength of 300.4 MPa and tensile strength of 329.8 MPa was prepared through hot extrusion.The use of zinc alloys in the preparation of cortical suspension fixation buttons was proposed for the first time.After 35 d of immersion in simulated body fluids,the ZMM42 alloy fixation buttons were degraded at a rate of 44μm/a,and the fixation strength was retained(379.55 N)in the traction loops.Simultaneously,the ZMM42 alloy fixation buttons exhibited an increase in MC3T3-E1 cell viability and high antibacterial activity against Escherichia coli and Staphylococcus aureus.These results reveal the potential of biodegradable zinc alloys for use as ligament reconstruction materials and for developing diverse zinc alloy cortical suspension fixation devices. 展开更多
关键词 anterior cruciate ligament reconstruction zinc alloy fixation buttons mechanical property corrosion behavior BIOCOMPATIBILITY
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
20
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部