期刊文献+
共找到4,547篇文章
< 1 2 228 >
每页显示 20 50 100
Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism 被引量:2
1
作者 Merve Bozkurt Gencer Hikmet Basmak +1 位作者 Erdogan Yasar Ozkan Onal 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第12期1876-1881,共6页
AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A t... AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group. 展开更多
关键词 CATARACT trifocal toric intraocular lens bifocal toric intraocular lens STEREOPSIS SATISFACTION
下载PDF
Optical quality of toric intraocular lens implantation in cataract surgery 被引量:9
2
作者 Xian-Wen Xiao Jing Hao +1 位作者 Hong Zhang Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第1期66-71,共6页
AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D ... AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P 】0.05), except the residual refractive cylinder(P 【0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery. 展开更多
关键词 optical quality analysis system toric intraocular lens ASTIGMATISM
下载PDF
Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker 被引量:2
3
作者 Javed Hussain Farooqui Archana Koul +1 位作者 Ranjan Dutta Noshir Minoo Shroff 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第5期703-706,共4页
AIM: To compare the accuracy of two different methods of preoperative marking for toric intraocular lens(IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for t... AIM: To compare the accuracy of two different methods of preoperative marking for toric intraocular lens(IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia.·METHODS: Toric IOLs were implanted in 180 eyes of110 patients. One group(55 patients) had preoperative marking of both eyes done with bubble marker(ASICO AE-2791TBL) and the other group(55 patients) with pendulum marker(Rumex 誖 3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop(version 7.0). Amount of alignment error(in degrees) induced in each group was measured.· RESULTS: Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83 ±2.31 in the pendulum marker group(P =0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3(P =0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5(P =0.612).·CONCLUSION: Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform. 展开更多
关键词 toric intraocular lens pendulum marker bubble marker
下载PDF
Combination of Toric and multifocal intraocular lens implantation in bilateral cataract patients with unilateral astigmatism 被引量:1
4
作者 Jing-Li Liang Fang Tian +1 位作者 Hong Zhang He Teng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第12期1766-1771,共6页
AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Tori... AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Toric and monofocal IOL implantation.METHODS: All the 30 patients with unilateral astigmatism suffered bilateral cataract were randomly divided into two groups: Toric plus multifocal IOL group and Toric plus monofocal IOL group. Uncorrected and corrected visual acuity at distance (5.0 m), intermediate distance (0.6 m), and near (0.33 m), contrast sensitivity, and stereopsis were assessed 6mo after surgery. Patients were also surveyed for visual disturbances and spectacle dependence.RESULTS: Binocular uncorrected visual acuity (LogMAR) of Toric/multifocal IOL eyes at distance, intermediate, near were 0.05±0.05, 0.24±0.10, and 0.14±0.06 respectively. The values of Toric plus monofocal IOL eyes were 0.06±0.07, 0.26±0.08, and 0.37±0.10 respectively. These values did not indicate significant differences between two groups with exception of near visual acuity. In the photopic condition (with or without glare), the contrast sensitivity of multifocal IOL eyes was significant lower than the monofocal IOL eyes in 18 cpd. In the mesopic condition, the contrast sensitivity of multifocal group was significant lower than monofocal group in 12 cpd, and in mesopic glare condition, this significant difference was found both in 6 cpd and 12 cpd. The stereopsis of Toric/multifocal IOL eyes decreased slightly (100±80 seconds of arc, t=2.222, P=0.136). Mean near vision for patient satisfaction was statistically significantly higher in Toric/multifocal IOL group patients versus than that in Toric/monofocal IOL group (80% vs 25.5%, P=0.000). Visual disturbance was not noticed in either group.CONCLUSION: Although the combination of Toric and multifocal IOL implantation results in compromising stereoacuity, it can still provide patients with high levels of spectacle freedom and good overall binocular visual acuity. 展开更多
关键词 toric MULTIFOCAL intraocular lens binocular cataract unilateral astigmatism
下载PDF
Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity 被引量:1
5
作者 Teresa Ferrer-Blasco Alberto Dominguez-Vicent +3 位作者 Santiago Garcia-Lazaro Maria Amparo Diez-Ajenjo Jose F.Alfonso Jose J.Esteve-Taboada 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1139-1144,共6页
AIM: To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses(IOLs) and assess whether its toricity has any impact in its repeatability. METHODS: An exp... AIM: To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses(IOLs) and assess whether its toricity has any impact in its repeatability. METHODS: An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and nontoric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation(Sw) and repeatability limit. RESULTS: The Sw was smaller than 0.011 μm for both lens groups and all Zernike coefficients, and the difference between both groups was smaller than 0.004 μm for all Zernike coefficients. Regarding the repeatability limit, this value was smaller than 0.025 μm for the toric lens group, and smaller than 0.031 μm for the non-toric lens one for all Zernike coefficients. Furthermore, the maximum difference between both lens groups was 0.010 μm. CONCLUSION: The repeatability of the NIMO TR1504 to measure the optical quality is high and independent of the lens toricity. These results reflect that this system is robust and could be used to measure the in-vitro optical quality of either toric or non-toric IOLs. 展开更多
关键词 in-vitro measurements optical quality intraocular lens REPEATABILITY
下载PDF
Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery 被引量:1
6
作者 Lara Buhl Julian Langer +3 位作者 Stefan Kassumeh Thomas C.Kreutzer Wolfgang J.Mayer Siegfried G.Priglinger 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1231-1236,共6页
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL... AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months. 展开更多
关键词 combined phaco-vitrectomy toric intraocular lens rotational stability corneal astigmatism CATARACT vitreoretinal disease
下载PDF
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism
7
作者 Paz Orts-Vila Salvador Aguilar-Corcoles +3 位作者 Cristina Tello-Elordi María Ramos-Alzamora Robert Montés-Mico Pedro Taná-Rivero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第10期1567-1573,共7页
AIM:To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens(IOL)in eyes with low degrees of corneal astigmatism.METHODS:Twenty-six eyes of 22 pat... AIM:To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens(IOL)in eyes with low degrees of corneal astigmatism.METHODS:Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL(FineVision PODFT,PhysIOL s.a.,Liege,Belgium)were enrolled.Phacoemulsification with femtosecond laser,capsular tension ring insertion and intraoperative aberrometry were performed in all cases.All IOLs used showed a cylinder power of 1.00 D.Main outcome measures were refractive error and corrected-distance visual acuity(CDVA)and uncorrected-distance visual acuity(UDVA)values.Eyes were evaluated at 4 mo post-surgery.RESULTS:Totally 50%of eyes showed a spherical equivalent(SE)within±0.13 D and all of them within±0.50 D.The mean SE and refractive cylinder were-0.02±0.23 and-0.16±0.22 D,respectively.Vector analysis revealed that 100%of eyes were within±0.50 D for the SE and cylindrical components(J0 and J45).Refractive changes were not correlated with keratometric changes(P>0.05)showing that the reduction in astigmatism comes from the trifocal toric IOL.Of 81%and 96%of eyes showed UDVA and CDVA of 20/20,respectively.The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.97±0.05 and 0.99±0.02(about 20/20),respectively.CONCLUSION:Our study suggests that the use of this trifocal toric IOL in patients with low amount of astigmatism provides accurate refractive outcomes and enables them to achieve excellent visual acuity. 展开更多
关键词 toric trifocal intraocular lens PHACOEMULSIFICATION CATARACT ASTIGMATISM
下载PDF
Case report:simultaneous femtosecond laser astigmatic keratotomy and toric intraocular lens implantation in femtosecond laser-assisted cataract surgery in a patient with surgically induced high corneal astigmatism
8
作者 Yan Guo Heather Edwards +2 位作者 Mark Woodward Tyrone Curtis Gresham Kayla Morgan 《Annals of Eye Science》 2022年第4期69-76,共8页
Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically... Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty(LTK)in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery(FLACS).This is the first report of both procedures combined simultaneously,with or without history of LTK.Case Description:A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004,with subsequent surgically induced high corneal astigmatism,and with age-related nuclear cataract of both eyes.IOL master demonstrated+7.71 diopters of astigmatism at 163 degree right eye and+3.29 diopters of astigmatism at 4 degree left eye.After extensive discussion of the risks and benefits,the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions(RIs)and toric IOL(Alcon SN6AT9)right eye;FLACS with toric IOL(Alcon SN6AT7)alone left eye.At 2-year follow-up,uncorrected visual acuity was 20/30 right eye,20/25 left eye.His best corrected visual acuity was 20/25(+0.25+1.00 axis 21)right eye and 20/20(plano+0.25 axis 90)left eye;his best corrected near visual acuity was J1+with add+2.50 diopters right eye and left eye.Conclusions:Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery.An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9,in our case,simultaneously,which can achieve an excellent long term visual outcome. 展开更多
关键词 High corneal astigmatism[induced by laser thermal keratoplasty(LTK)] femtosecond laser astigmatic keratotomy(FSAK) toric intraocular lens implantation(IOL implantation) femtosecond laser-assisted cataract surgery(FLACS) case report
下载PDF
Association between axial length and toric intraocular lens rotation according to an online toric back-calculator 被引量:1
9
作者 Jennifer L.Patnaik Malik Y.Kahook +4 位作者 John P.Berdahl David R.Hardten Brandie D.Wagner Leonard K.Seibold Brent A.Kramer 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第3期420-425,共6页
AIM: To assess the relationship between axial length(AL) and intraocular lens(IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database.METHODS: Retrospectiv... AIM: To assess the relationship between axial length(AL) and intraocular lens(IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database.METHODS: Retrospective analysis of data collected online via astigmatismfix.com, a freely available online toric back-calculator where surgeons enter pre-and postoperative information to help manage residual postoperative astigmatism.Included records were deemed valid with entry of AL and IOL orientation between January 2017 and March 2019.Rotation was determined by a difference of ≥5° between pre-operative intended IOL orientation and actual post-operative IOL orientation.Frequency and magnitude of rotation are presented with means and associated standard deviation(SD).Linear regression models of this association are presented.RESULTS: Records of 6752 eyes were included in the analysis, of which 74.8% were determined to have a rotated IOL.The magnitude of rotation increased with each millimeter(mm) increase in AL with a mean rotation of 13.3°(SD: 12.8°) for eyes with AL 20-20.9 mm and a maximum mean rotation of 30.6°(SD: 30.3°) among eyes with AL 29-29.9 mm.General linear modeling demonstrated a significant association(P<0.0001) with a parameter estimate of 1.19(standard error: 0.159) and R;of 0.0083.CONCLUSION: Analysis from an online database indicates that toric IOLs inserted into eyes with longer AL are more likely to rotate and to rotate more degrees from the target axis.The findings from this study are clinically relevant for surgeons implanting toric IOLs. 展开更多
关键词 cataract surgery toric lens axial length ROTATION
下载PDF
The Effect of Anterior Corneal Astigmatism Orientation on Toric Intraocular Lens Outcomes
10
作者 Eugene A. Lowry Jonathan Li +4 位作者 Sundeep K. Kasi Seth Blumberg Priya Morjaria Steven Schallhorn Ayman Naseri 《Open Journal of Ophthalmology》 2019年第2期84-93,共10页
Background: It is unclear whether post-operative errors after toric intraocular lens implantation would be more amenable to pre-operative correction with a fixed adjustment or a correction ratio that scales with the m... Background: It is unclear whether post-operative errors after toric intraocular lens implantation would be more amenable to pre-operative correction with a fixed adjustment or a correction ratio that scales with the magnitude of pre-operative astigmatism. Purpose: To investigate the effect of pre-operative anterior corneal astigmatism orientation on outcomes of toric intraocular lens implantation in a large population. Methods: A retrospective cohort study of 625 patients undergoing refractive lens exchange through a superior clear corneal incision with Oculentis M-Plus toric intraocular lens implantation at an Optical Express, Inc. located in the United Kingdom and Ireland. Patients were stratified by axis of astigmatism on automated keratometry as with-the-rule, against-the-rule, or oblique. Analysis of visual acuity and refractive outcomes was performed using American National Standards Institute (ANSI) guidelines on astigmatic corrections with non-vector as well as vector analyses. Analysis was limited to one eye per patient. Results: Patients who had with-the-rule (WTR) astigmatism, compared with oblique and against-the-rule (ATR), had higher vector magnitudes of surgically induced refractive correction (2.89D, 2.55D, 2.42D;p Conclusions: Refractive lens exchange surgery using toric intraocular lenses overcorrected patients who had with-the-rule astigmatism. Degree of overcorrection did not vary with severity of pre-operative astigmatism. Incorporation of axis of astigmatism in lens selection and reduction of astigmatic correction among with-the-rule patients by an absolute value of 0.25D - 0.35D, rather than proportional adjustments, may reduce cylindrical over-correction. 展开更多
关键词 toric lens ASTIGMATISM CATARACT Surgery Refractive lens Exchange
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
11
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
Modeling monocular form deprivation in rabbits using a simulated-cataract intraocular lens
12
作者 Si-Yi Gu Li-Ming Xu +9 位作者 Wei-Jie Sun Li-Li Liang Lei Lin Han Zou Jing-Yuan Xu Yu Zheng Yuan-Yuan Li Yin-Ying Zhao Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2177-2184,共8页
AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL mater... AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL materials were prepared.The light transmission of the PSF-IOL was measured,and its in vitro biosafety was determined by cell counting kit(CCK)-8 assay using the HLEC-B3 cell line and ARPE-19 cell line.Subsequently,the in vivo safety was determined by implanting the PSF-IOL with 10%wt SiO_(2) into the right eyes of New Zealand white rabbits(PSF-IOL group),and compared with two control groups:contralateral comparison group and normal control(NC)group(Contralateral comparison group:the fellow eye;NC group:a group of binocular normal rabbits without intervention).The flash visual-evoked potentials(F-VEPs)were measured to verify amblyopia.RESULTS:PSFs containing 0,2%,and 10%wt SiO_(2) were successfully constructed.The 0 SiO_(2) PSF was transparent,while the 10%wt SiO_(2) PSF was completely opaque.It was found that PSF did not induce unwanted cytotoxicity in HLECs and ARPE19 cells in vitro.In vitro,PSF-IOL with 10%wt SiO_(2) was also non-toxic,and no significant inflammation or structural changes occurred after four weeks of PSF-IOL implantation.Finally,our IOL-simulated congenital cataract rabbit detected by F-VEPs suggested tentative amblyopia.CONCLUSION:A PSF-IOL that mimics cataracts is created.A novel form deprivation model is created by the IOL-simulated congenital cataract rabbit.It can be developed fast and stable and holds great potential for future study. 展开更多
关键词 monocular deprivation form deprivation intraocular lens congenital cataract AMBLYOPIA
下载PDF
Biocompatibility of light responsive materials prepared for accommodative intraocular lenses manufacturing
13
作者 Chen-Zi Liu Ming-Hao Sun +2 位作者 Wei Dai Lan-Cao Hao Si-Quan Zhu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2167-2176,共10页
AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular le... AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis. 展开更多
关键词 light responsive materials accommodative intraocular lens BIOCOMPATIBILITY bacterial adhesion
下载PDF
Intraocular lens selection in diabetic patients:How to increase the odds for success
14
作者 Arvind Kumar Morya Prateek Nishant +4 位作者 Prasanna Venkatesh Ramesh Sony Sinha Aarti Heda Sarika Salodia Ripunjay Prasad 《World Journal of Diabetes》 SCIE 2024年第6期1199-1211,共13页
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur... The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population. 展开更多
关键词 DIABETICS CATARACT intraocular lens Diabetic retinopathy Diabetes mellitus
下载PDF
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
15
作者 Humberto Carreras-Díaz Josefina Reñones de Abajo +1 位作者 María del Rosario Carreras-Díaz Amalia Lorente-Velázquez 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1322-1330,共9页
AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed inc... AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change. 展开更多
关键词 V4c toric collamer lens corneal astigmatism surgically induced astigmatism corneal coupling
下载PDF
Toric markers-assisted implantation of the scleral-fixated intraocular lens
16
作者 Hu-Ping Song Bing-Yu Tian Jing Peng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第9期1289-1293,共5页
AIM:To evaluate the efficacy of toric intraocular lens markers-assisted implantation of the scleral-fixated intraocular lens(SFIOL).METHODS:From October 2010 to December 2013,all patients who had undergone seconda... AIM:To evaluate the efficacy of toric intraocular lens markers-assisted implantation of the scleral-fixated intraocular lens(SFIOL).METHODS:From October 2010 to December 2013,all patients who had undergone secondary SFIOL implantation were assigned to group 1 and 2,in group 1SFIOL was performed with the assist of radial keratotomy(RK)-marker,and in group 2 SFIOL was performed with the assisted of toric intraocular lens markers(T-and axis markers).Patients' demographic data and information on baseline preoperative visual acuity,indication for surgery and latest postoperative visual acuity were collected and analyzed.The haptic and optic positions were determined by ultrasound biomicroscopy.The optic tilt angle and decentration distance were measured.RESULTS:The study evaluated 43 eyes of 43 patients ranging in age from 3 to 66 y.Group 1 comprised 24 eyes(24 patients) and group 2,19 eyes(19 patients).Uncorrected reoperative acuity was improved on all the eyes postoperatively.The improved postoperative acuity was significantly more in group 2 than that in group 1(1.11 ±0.38 vs 0.82 ±0.45 logMAR;F=4.85,P=0.03).Ultrasonic biomicrograph examination showed that the rate of haptic asymmetry was significantly higher in group 1(42%,10/24) than that in group 2(11%;2/19)(Chi square=3.68,P=0.04).The mean tilted degree in group 1was significantly higher than that in group 2(P=0.04).Mean decentration distance in group 1 was greater than that in group 2(P=0.03).CONCLUSION:During SFIOL the toric markers help the surgeon identify the placement of fixation more precisely than that with the use of RK marker. 展开更多
关键词 scleral fixation intraocular lens APHAKIA toric markers
下载PDF
Clinical Effect Analysis of Posterior Chamber Intraocular Lens Implantation for Correcting High Myopia and Astigmatism
17
作者 Bo Xia Dan Dan Zhao 《Journal of Clinical and Nursing Research》 2024年第8期99-104,共6页
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca... Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety. 展开更多
关键词 Posterior chamber intraocular lens implantation in phakic eyes High myopia ASTIGMATISM Corrective effect
下载PDF
Toric Intraocular Lens vs. Peripheral Corneal Relaxing Incisions to Correct Astigmatism in Eyes Undergoing Cataract Surgery 被引量:9
18
作者 Zhiping Liu Xiangyin Sha +3 位作者 Xuanwei Liang Zhonghao Wang Jingbo Liu Danping Huang 《Eye Science》 CAS 2014年第4期198-203,共6页
Purpose:.To compare toric intraocular lens implantation(ToricIOL).with peripheral corneal relaxing incisions(PCRIs) for astigmatism correction in patients undergoing cataract surgery.Methods: 54 patients(54 eyes) with... Purpose:.To compare toric intraocular lens implantation(ToricIOL).with peripheral corneal relaxing incisions(PCRIs) for astigmatism correction in patients undergoing cataract surgery.Methods: 54 patients(54 eyes) with more than 0.75 diopter(D).of preexisting corneal astigmatism were classified as group A(0.75-1.50D) or group B(1.75-2.50D). The patients were randomized to undergo Toric-IOL or PCRIs in the steep axis with spherical IOL implantation..Log MAR uncorrected visual acuity(Log MAR UCVA), Log MAR best corrected vi sual acuity.(Log MAR BCVA),.error of vector(|EV|), surgery induced refraction correction.(|SIRC |),.and correction rates(CR) were measured 1 month and 6 months postoperatively.Results: At 6 months postoperatively, all 54 eyes had LogMAR BCVA≤0.2. Patients who underwent PCRIs and ToricIOL with Log MAR BCVA≤0.1 showed no significant differences in group A(P=1.00) or in group B(P=0.59). Group A showed no significant differences in Log MAR UCVA(P =0.70), |EV|(P=0.13), |SIRC|(P=0.71), and CR(P=0.56)in patients underwent PCRIs and Toric-IOL. However, group B showed significant differences in Log MAR UCVA(P <0.01), |EV|(P<0.01)), |SIRC|(P<0.01), and CR(P<0.01).The Log MAR UCVA and |EV | between 1 and 6 months showed no significant differences in patients in group A. However, in group B, they are significant differences.Conclusion:.The efficacy and stability of Toric-IOL and PCRIs were equal in low astigmatic patients..Toric-IOL achieved an enhanced effect over PCRIs in higher astigmatic patients.PCRIs had the more refractive regression than Toric-IOL in 6months. 展开更多
关键词 白内障手术 屈光矫正 人工晶体 散光 角膜 切口 松解 眼睛
下载PDF
Considerations in the management of single-piece intraocular lenses outside the capsular bag
19
作者 Anna K Junk 《World Journal of Ophthalmology》 2014年第3期87-91,共5页
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who... AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible. 展开更多
关键词 Cataract surgery Sulcus intraocular lens implant Single piece intraocular lenses Three piece intraocular lenses Posterior capsule tear Cataract surgery complication Pigment dispersion Cystoid macula edema Anterior vitrectomy
下载PDF
Multifocal and extended depth of focus intraocular lenses
20
作者 Georgios Kondylis Olga Klavdianou Sotiria Palioura 《Annals of Eye Science》 2019年第1期13-18,共6页
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number... Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL. 展开更多
关键词 Cataract surgery quality of vision intraocular lens implantation trifocal intraocular lens bifocal intraocular lens
下载PDF
上一页 1 2 228 下一页 到第
使用帮助 返回顶部