期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Primary intratracheal schwannoma misdiagnosed as severe asthma in an adolescent:A case report 被引量:1
1
作者 Hui-Rong Huang Pei-Qiang Li Yi-Xin Wan 《World Journal of Clinical Cases》 SCIE 2021年第17期4388-4394,共7页
BACKGROUND Primary intratracheal schwannoma is an extremely rare type of benign airway tumor,especially in adolescents.The presenting symptoms are typically prolonged cough and wheezing that can be misdiagnosed as ast... BACKGROUND Primary intratracheal schwannoma is an extremely rare type of benign airway tumor,especially in adolescents.The presenting symptoms are typically prolonged cough and wheezing that can be misdiagnosed as asthma in adolescent patients.CASE A 16-year-old adolescent girl admitted to a local hospital with symptoms of an irritating cough and wheezing was diagnosed with bronchial asthma and treated with budesonide and formoterol.Over the next year,the patient's wheezing and coughing symptoms gradually worsened and the antiasthma treatment was ineffective.One week prior to this admission,the patient developed dyspnea after catching a cold and was transferred to our hospital with a diagnosis of severe asthma.However,chest computed tomography and bronchoscopy showed a mass in the trachea.Primary intratracheal schwannoma was diagnosed by biopsy.Her symptoms were relieved by endoscopic resection by electrosurgical snaring combined with argon plasma coagulation.No relapse occurred during an 18 mo follow-up.CONCLUSION Primary intratracheal schwannoma should be considered in the differential diagnosis in adolescents with recurrent asthma-like attacks. 展开更多
关键词 intratracheal schwannoma ADOLESCENT Severe asthma MISDIAGNOSIS Endoscopic resection Case report
下载PDF
气管插管致声带后份溃疡1例
2
作者 肖淑芬 徐静 《中国耳鼻咽喉头颈外科》 2012年第9期490-490,共1页
气管插管喉损伤主要有喉黏膜损伤、喉水肿、损伤性喉肉芽肿、环杓关节脱位及喉神经麻痹等[1],但因气管插管引起双侧声带后份对称性溃疡者,未见报道。我院近遇1例,报道如下。
关键词 插管法 气管内(Intubation intratracheal) 创伤和损伤(Wounds and Injuries) 喉(Larynx) 手术后并发症(Postoperative Complications)
下载PDF
多次反复气管插管导致声门下狭窄1例 被引量:1
3
作者 黄亚萍 黄振云 刘大波 《中国耳鼻咽喉头颈外科》 CSCD 2013年第10期559-560,共2页
近年来,有关儿童因气管内插管导致医源性声门下狭窄的报道甚少。我科收住1例4月余龄患儿,因先后反复插管7次,致医源性声门下狭窄,最终因呼吸困难行气管切开术,现报道如下。
关键词 插管法 气管内(Intubation intratracheal) 喉狭窄(Laryngostenosis stenosis) 声门(Glottic)
下载PDF
Changes in peak inspiratory flow rate and peak airway pressure with endotracheal tube size during chest compression 被引量:2
4
作者 Jung Wan Kim Jin Woong Lee +4 位作者 Seung Ryu Jung Soo Park InSool Yoo Yong Chul Cho Hong Joon Ahn 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2020年第2期97-101,共5页
BACKGROUND:Adequate airway management plays an important role in high-quality cardiopulmonary resuscitation(CPR).Airway management is usually performed using an endotracheal tube(ETT)during CPR.However,no study has as... BACKGROUND:Adequate airway management plays an important role in high-quality cardiopulmonary resuscitation(CPR).Airway management is usually performed using an endotracheal tube(ETT)during CPR.However,no study has assessed the effect of ETT size on the fl ow rate and airway pressure during CPR.METHODS:We measured changes in peak inspiratory fl ow rate(PIFR),peak airway pressure(Ppeak),and mean airway pressure(Pmean)according to changes in ETT size(internal diameter 6.0,7.0,and 8.0 mm)and with or without CPR.A tidal volume of 500 mL was supplied at a rate of 10 times per minute using a mechanical ventilator.Chest compressions were maintained at a constant compression depth and speed using a mechanical chest compression device(LUCAS2,mode:active continuous,chest compression rate:102±2/minute,chest compression depth 2–2.5 inches).RESULTS:The median of several respiratory physiological parameters during CPR was significantly different according to the diameter of each ETT(6.0 vs.8.0 mm):PIFR(32.1 L/min[30.5–35.3]vs.28.9 L/min[27.5–30.8],P<0.001),Ppeak(48.84 cmH2O[27.46–52.11]vs.27.45 cmH2O[22.53–52.57],P<0.001),and Pmean(18.34 cmH2O[14.61–21.66]vs.13.66 cmH2O[8.41–19.24],P<0.001).CONCLUSION:The changes in PIFR,Ppeak,and Pmean were related to the internal diameter of ETT,and these values tended to decrease with an increase in ETT size.Higher airway pressures were measured in the CPR group than in the no CPR group. 展开更多
关键词 Cardiopulmonary resuscitation intratracheal intubation Airway pressure
下载PDF
Improving endotracheal tube tolerance with intracufflidocaine: a meta-analysis of randomized controlled trials
5
作者 CHEN Wei SUN Pengling +3 位作者 YANG Liye PU Jun YUAN Hongbin TIAN Mouli 《Journal of Medical Colleges of PLA(China)》 CAS 2013年第5期302-312,共11页
Objective: The aim of this study was to compare the efficacy in alleviating the endotracheal tube related discomfort and the safetyof intracufflidocaine (in different forms) with air and/or normal saline (NS) dur... Objective: The aim of this study was to compare the efficacy in alleviating the endotracheal tube related discomfort and the safetyof intracufflidocaine (in different forms) with air and/or normal saline (NS) during general anesthesia with tracheal intubation. Methods: Cochrane Central Register of Controlled Trials, PubMed and Embase were searched for relevant studies. Thirteen randomized, controlled trials involving 1 010 patients were ultimately identified. A meta-analysis of all randomized controlled trials fulfilling the predefined criteria was performed. Random-effect model and subgroup studies were used when significant heterogeneity existed among those trials. Results: Compared with air and NS, intracufflidocaine could significantly alleviate the severity of sore throat at different time points (15min, 30min, lh, 2h, 3h, 6h, 12h and 24h aiter extubation) and the occurrence of cough, restlessness, postoperative nausea and vomiting, dysphonia and hoarseness. Besides intracufflidocaine brought about a significant prolongation of spontaneous ventilation time. It was worth mentioning that, compared withlidocaine or its hydrochloride form, alkalinized lidocainewas much more efficient in reducing the severity of sore throat and prolonging spontaneous ventilation time. Conclusion: The present meta-analysis indicates that intracuttlidocaine can significantly improve endotracheal tube tolerance and this improvement can be strengthened by alkalinization of lidocaine. 展开更多
关键词 Intubation intratracheal Lidocaine administration Anesthesia recovery period
下载PDF
Angle Effect to Dropping of Dew in Closed Suction Catheters
6
作者 Kazuto Doi Mayumi Doi +3 位作者 Yukoh Yaegashi Katsuhisa Imoto Masaru Ando Junichi Kadota 《Health》 2018年第6期719-729,共11页
Intratracheal aspiration in a patient on ventilation is generally performed using a catheter. Of late, closed suction systems have been used more frequently than open systems. To remove tracheal secretions through the... Intratracheal aspiration in a patient on ventilation is generally performed using a catheter. Of late, closed suction systems have been used more frequently than open systems. To remove tracheal secretions through the intratracheal tube, catheter suction is used, and the suction catheter may be of the closed- or open-type. The catheters are cleaned by flushing with sterile 0.9% saline, resulting in dropping of dew. This phenomenon is caused by some factors: influence of flow, clogging of the suction tube, problem of manipulation of flushing and angle between the intubation tube and the connection port. But this dropping has not yet been investigated. In this study, we focused at this angle and we used the test lung which is simulated machine on behalf of patient. We consider two situations adult and child, also two types of catheters Eco-Cath and Ty-care. In child case we consider elbow-type suction catheters and Y-connector type. The angle was set at 0&#176;, 20&#176;, 40&#176;, 60&#176;, and 90&#176;, and we observed the difference between Eco-Cath and Ty-care. In adults difference is significant (p 0.001), In 90&#176;between Tracheal intubation and Tracheotomy (p ≈ 0.26). In child difference is significant (p 0.001), In 90&#176;between Tracheal intubation and Tracheotomy (p ≈ 0.15). In child case we observed dependency of angle on various conditions too. The relation of the angle and dew was clarified. 展开更多
关键词 CATHETERS intratracheal INTUBATION Respiration Suction TRACHEOSTOMY VENTILATORS
下载PDF
Digital Intubation without Stylet: Myth or Reality? Case Report
7
作者 Maya Christiam Mauricio Jesús Alberto Melendez Ordoñez +8 位作者 Ismael Bernardo Viveros Peralta Villanueva Verónica Juan José Dosta Herrera Andrea Carolina Jimenez Palacios Jimmy Andersson Delgado Criollo Monserrat Escalante Rodríguez Dalia Fernanda Farrera Rámirez Maribel Méndez Suarez Pedro Sánchez Mata 《Open Journal of Anesthesiology》 2021年第5期156-163,共8页
Digital intubation was discovered as one of the first methods to face a difficult airway without direct laryngoscopy. From the very beginning, this technique has been surrounded by much controversy, mainly because it ... Digital intubation was discovered as one of the first methods to face a difficult airway without direct laryngoscopy. From the very beginning, this technique has been surrounded by much controversy, mainly because it required to be performed by an expert. Nowadays, it remains a useful technique when treating patients with difficult airways, so it is of utmost importance all personnel involved with airway management must know and perfect this technique when scenarios where conventional laryngoscopy or rescue devices for difficult airway are not available or contraindicated. The present work’s main objective is to suggest digital intubation as a safe and effective technique for the management of patients with difficult airways when there are no other devices available. The authors present a successful case of digital intubation on a patient with a difficult airway, demonstrating this technique is useful when performed by expert practitioners and when there is no other equipment available. 展开更多
关键词 Intubation intratracheal OXYGENATION ANESTHESIA Airway Management
下载PDF
气管插管喉部并发症 被引量:1
8
作者 陈浩 孙敬武 万光伦 《国际耳鼻咽喉头颈外科杂志》 2012年第5期262-265,共4页
气管插管被用于解除上呼吸道梗阻、呼吸衰竭时的辅助通气、呼吸道管理和手术麻醉需要,但同时气管插管也可以引起多种喉部并发症,特别是长期插管的患者。本文对气管插管所致喉部并发症的类型、相关因素及防治方法进行综述。
关键词 插管法 气管内(Intubation intratracheal) 喉疾病(Laryngeal Dieases) 喉镜(Laryngoscopy)
原文传递
头颈外科患者围手术期气道管理 被引量:1
9
作者 余琼 胡国华 《国际耳鼻咽喉头颈外科杂志》 2010年第3期159-161,共3页
围手术期发生困难气道,通气无法维持,短时间内就可因缺氧而导致心跳骤停、大脑损害,甚至死亡。各种口、面、头颈部解剖结构异常所致的困难气道在围手术期困难气道患者中占相当高的比例。本文针对头颈外科患者围手术期困难气道的识别... 围手术期发生困难气道,通气无法维持,短时间内就可因缺氧而导致心跳骤停、大脑损害,甚至死亡。各种口、面、头颈部解剖结构异常所致的困难气道在围手术期困难气道患者中占相当高的比例。本文针对头颈外科患者围手术期困难气道的识别与处理以及气道管理做一综述。 展开更多
关键词 围手术期医护(Perioperative Care) 气道阻塞(Airway Obstruction) 插管法 气管内(Intubation intratracheal)
原文传递
Evaluation of high-concentration sevoflurane for induction and nasotracheal intubation without muscle relaxant for infants with different pulmonary blood flow undergoing surgery for congenital heart diseases 被引量:8
10
作者 WANG Kai-yuan WANG Hong-wu XIN Lian-feng WANG Yong-wang XUE Yu-liang 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第24期4144-4148,共5页
Background Inhalational anesthesia with sevoflurane for endotracheal intubation without muscle relaxant is now used widely for pediatric patients. This study assessed the efficacy and safety of induction with high con... Background Inhalational anesthesia with sevoflurane for endotracheal intubation without muscle relaxant is now used widely for pediatric patients. This study assessed the efficacy and safety of induction with high concentration sevoflurane and of nasotracheal intubation without muscle relaxant in infants with increased or decreased pulmonary blood flow (PBF) and undergoing surgery for congenital heart diseases. Methods Fifty-five infants aged 2-12 months, weighing 4.7-10.0 kg, and scheduled for congenital cardiac surgery were enrolled. Subjects were divided into those with increased (IPBF group, n--29) and decreased (DPBF group, n=26) pulmonary blood flow. All infants received inhalational induction with 8% sevoflurane in 100.0% oxygen at a gas flow rate of 6 L/min. Nasotracheal intubation was performed 4 minutes after induction. Sevoflurane vaporization was decreased to 4.0% for placement of a peripheral intravenous line and invasive hemodynamic monitors. Five minutes later, sedatives and muscle relaxant were administered and the vaporizer was adjusted to 2% for maintenance of anesthesia. Bispectral index (BIS) scores, circulatory parameters, satisfactory and successful intubation ratios, adverse reactions, and complications of intubation were recorded. Results Times to loss of lash and pain reflexes were longer for the DPBF group (P 〈0.01). Satisfactory intubation ratios were 93.1% and 61.5% for the I PBF and DPBF groups, respectively (P=0.008). Successful intubation ratios were 96.6% and 76.9% for the IPBF and DPBF groups, respectively (P=0.044). Following sevoflurane inhalation, blood pressures decreased significantly in the IPBF group but remained stable in the DPBF group. BIS scores declined to similar stable values, and a "nadir BIS" was recorded for both groups. No obvious adverse reactions or complications of intubation were noted perioperatively. Conclusions Induction with high concentration sevoflurane, although faster for infants with IPBF, is safe for infants with IPBF or DPBF. However, nasotracheal intubation without muscle relaxant after induction with high concentration sevoflurane is less successful and less satisfactory for infants with DPBF and should be used with caution in this patient group. 展开更多
关键词 anesthetics inhalation infant intubation intratracheal heart defects congenital
原文传递
Sustained release of isoniazid from polylactide microspheres prepared using solid/oil drug loading method for tuberculosis treatment 被引量:6
11
作者 Limei Zhang Ying Li +1 位作者 Yun Zhang Chunyan Zhu 《Science China(Life Sciences)》 SCIE CAS CSCD 2016年第7期724-731,共8页
Polylactide(PLA) microspheres were prepared using the solid-in-oil(S/O) spray-drying method to achieve the sustained release of a hydrophilic drug for the treatment of tuberculosis, via intratracheal instillation. Iso... Polylactide(PLA) microspheres were prepared using the solid-in-oil(S/O) spray-drying method to achieve the sustained release of a hydrophilic drug for the treatment of tuberculosis, via intratracheal instillation. Isoniazid(IN), a low-molecular-weight hydrophilic drug, was used as a model drug. The effects of various sizes of micronized IN powder, different drug/polymer ratios, spray-drying process parameters, and drug-release characteristics were studied to optimize the manufacturing parameters. A high entrapment efficiency(87.3%) was obtained using this method; furthermore, the microspheres were spherical and smooth. They were individually and homogenously distributed, with a mean diameter of 5.6 μm; furthermore, they showed a satisfactory extended sustained-release phase. After administration of the microspheres to rats, pulmonary drug concentrations were maintained at a relatively stable level for up to 4 weeks. 展开更多
关键词 ISONIAZID polylactide microspheres sustained release solid/oil spraying method intratracheal intubation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部