Three-dimensional(3D)printing is a highly automated platform that facilitates material deposition in a layer-by-layer approach to fabricate pre-defined 3D complex structures on demand.It is a highly promising techniqu...Three-dimensional(3D)printing is a highly automated platform that facilitates material deposition in a layer-by-layer approach to fabricate pre-defined 3D complex structures on demand.It is a highly promising technique for the fabrication of personalized medical devices or even patient-specific tissue constructs.Each type of 3D printing technique has its unique advantages and limitations,and the selection of a suitable 3D printing technique is highly dependent on its intended application.In this review paper,we present and highlight some of the critical processes(printing parameters,build orientation,build location,and support structures),material(batch-to-batch consistency,recycling,protein adsorption,biocompatibility,and degradation properties),and regulatory considerations(sterility and mechanical properties)for 3D printing of personalized medical devices.The goal of this review paper is to provide the readers with a good understanding of the various key considerations(process,material,and regulatory)in 3D printing,which are critical for the fabrication of improved patient-specific 3D printed medical devices and tissue constructs.展开更多
BACKGROUND An intrauterine device(IUD)is a contraceptive device placed in the uterine cavity and is a common contraceptive method for Chinese women.However,an IUD may cause complications due to placement time,intraute...BACKGROUND An intrauterine device(IUD)is a contraceptive device placed in the uterine cavity and is a common contraceptive method for Chinese women.However,an IUD may cause complications due to placement time,intrauterine pressure and other factors.Ectopic IUDs are among the most serious complications.Ectopic IUDs are common in the myometrium and periuterine organs,and there are few reports of ectopic IUDs in the urinary bladder,especially in the anterior wall.CASE SUMMARY A 52-year-old woman was hospitalized due to a urinary bladder foreign body found via abdominal ultrasound and computed tomography(CT)examination.The patient had a 2-year history of recurrent abdominal distension and lower abdominal pain,accompanied by frequent urination,urgency,dysuria and other discomfort.Ultrasound examination revealed foreign bodies in the bladder cavity,with calculus on the surface of the foreign bodies.CT revealed a circular foreign body on the anterior wall of the urinary bladder,suggesting the possibility of an ectopic IUD.After laparoscopic exploration,an annular IUD was found in the anterior wall of urinary bladder,and an oval calculus with a diameter of approximately 2 cm was attached to the surface of the bladder cavity.The IUD and calculus were successfully and completely removed.The patient recovered well after surgery.CONCLUSION Abdominal ultrasound and CT are effective methods for detecting ectopic IUDs.The IUD is located in the urinary bladder and requires early surgical treatment.The choice of surgical method is determined by comprehensively considering the depth of the IUD in the bladder muscle layer,the situation of complicated calculus,the situation of intravesical inflammation and medical technology and equipment.展开更多
Objective To explore and investigate a new treatment of releasing the risks and pain in removing intrauterine devices (IUD) from postmenopausal women. Methods Totally 240 postmenopausal women who needed to remove IU...Objective To explore and investigate a new treatment of releasing the risks and pain in removing intrauterine devices (IUD) from postmenopausal women. Methods Totally 240 postmenopausal women who needed to remove IUD were randomly divided into 3 groups. Group A (n =80) were preoperatively treated with 20 g/L vaginal testosterone propionate cod liver oil ointment (1 g/d) over a 2-week span of period, and vaginal misoprostol (200 μg) was one-time used at 2-3 h before operation. Group B (n =80) were treated with oral estradiol valerate (3 mg/d) from 7 d before operation. Other 80 women (group C) were treated with vaginal cod liver oil ointment (1 g/d) over a 2-week span of period before the operation day. The degree of cervical relaxation, operational difficulty, blood loss volume, the length of operation time and visual analogue scales (VAS) were evaluated, also the serum estradiol, testosterone and endometrial thickness were measured before and after medication. Results The degree of cervical relaxation, operational difficulty, blood loss, the length of operation time and VAS in group A were significantly better than those group C (P〈0.01), whiles its blood loss volume was less than group B (P〈0.05) and there were no significant differences in serum estradiol, testosterone and endometrial thickness before and after medication. Conclusion Preoperative vaginal testosterone propionate combined with misoprostol would reduce the operational difficulties/risks and release the suffering of patients. The study may represent a safe and effective alternative to remove IUD in postmeno- pausal women.展开更多
The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation funct...The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation function,sensitivity to estrogen and progesterone,cell proliferation,and immune response of the endometrium.Studies on the morphology of endometrium indicate that the use of Cu-IUDs can affect the number and binding capacity of estrogen and progesterone receptors in the endometrium and reduce the response of the endometrium to estrogen and progesterone.The use of Cu-IUDs can also affect the proliferation of endometrial cells,suggesting that the aseptic inflammation caused by Cu-IUDs may differ from chronic infectious or noninfectious inflammation;this highlights that the use of Cu-IUDs provides protection against endometrial proliferative diseases.The use of Cu-IUDs increases local endometrial angiogenesis,bleeding tendency,and fibrinolytic activity,which can result in prolonged menstruation or abnormal uterine bleeding.Additionally,the use of Cu-IUDs can cause the infiltration of numerous lymphocytes,monocytes,macrophages,and other inflammatory cells around the endometrial gland and changes in endometrial immune function,immune cell function,and the number and type of immune molecules.Cu-IUD-induced decidual injury significantly increases the invasiveness of trophoblasts,further affecting the aberrant expression of their growth-,angiogenesis-,and invasion-related factors and improving the formation of the placenta.Moreover,the endometrial damage caused by Cu-IUD placement before embryo transfer can improve both clinical pregnancy and live birth rates;however,specific changes in the immune system after Cu-IUD use as well as its effects on future pregnancies require further investigation.展开更多
Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface...Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface area of Cu-IUDs on cell toxicity.Methods Cu-IUDs were incubated in 10% FBS-DMEM/F12 culture medium at 37 ℃ for 24 h. The extracts were analyzed by flame atomic absorption spectrometer and were then diluted into different concentrations with culture medium. Finally, cytotoxicity of these original and diluted extracts on CHO-K1 cells was detected by cell counting kit-8 (CCK-8) assay.Results The viabilities of cells treated with the original extracts of six Cu-IUDs (TCu220C bulb, TCu220C, GCu220, GCu300, Yuangong Cu270 and Yuangong Ⅱ- 300) were all below 10% and the cupric ion concentrations in these extracts were 28.22 mg/L, 31.80 mg/L, 92.80 mg/L, 99.74 mg/L, 114.90 mg/L and 119.20 mg/L, respectively. After these original extracts were diluted, significant differences in cytotoxicity were exhibited. IUDs with larger copper surface areas (GCu300 and Yuangong Ⅱ-300) showed more cytotoxicity than those with smaller areas (GCu220 and Yuangong Cu270) respectively; When different shapes of Cu-IUDs were compared, TCu220C bulb showed lower cytotoxicity than TCu220C, and GCu300 exhibited higher toxicity than Yuangong Ⅱ-300; TCu220C displayed significantly lower cytotoxicity than GCu220 due to their differences in frames.Conclusion We presented evidence on the cytotoxic effects of copper ions released from Cu-IUDs on CHO-K1 cells and found that shape, frame together with copper surface area of Cu-IUDs had obvious influence on the cytotoxicity.展开更多
Objective: The aim of this study was to describe the use of the postpartum intrauterine device in the maternity ward of the Ratoma communal medical center in Conakry. Methods: This was a descriptive cross-sectional st...Objective: The aim of this study was to describe the use of the postpartum intrauterine device in the maternity ward of the Ratoma communal medical center in Conakry. Methods: This was a descriptive cross-sectional study carried out between July 1<sup>st</sup> 2015 and June 30 2016, i.e. a duration of one year. Results: A total of 551 patients received advice on various contraceptive methods. Most of this advice was given in the post-partum period (40.2%) and during antenatal care (39.1%). Of the patients advised, 87 (15.8%) used the intrauterine device. The majority of users (93%) were married and uneducated (63.2%), and 39.1% were poor. The majority (56.3%) of intra-uterine devices were inserted in the immediate post-partum period. The majority of women had no adverse events either during the first six weeks (n = 57;65.5%) or at 3<sup>rd</sup> months (n = 75;86.2%) or 6<sup>th</sup> months (n = 76;87.4%) after IUD insertion. Most users remained complication-free throughout the follow-up period (n = 76;87.4% at 6<sup>th</sup> weeks and 3<sup>rd</sup> months, and n = 77;88.5% at 6<sup>th</sup> months). The continuation rate was 89.7% at 6 weeks and 3<sup>rd</sup> months, and 87.4% at 6<sup>th</sup> months after insertion. The majority of users (87.0%) were satisfied with the care they received. Conclusion: This study showed very few complications among intrauterine device users, and high continuation and satisfaction rates. The intrauterine device is a long-acting, effective, reversible and safe contraceptive that can be used by most women for birth spacing in Guinea, where women do not regularly visit health facilities.展开更多
Objective To study the patent situation of medical device industry in China based on patent data.Methods The analysis function of the patent search software incoPat was used to analyze the patent situation from two pe...Objective To study the patent situation of medical device industry in China based on patent data.Methods The analysis function of the patent search software incoPat was used to analyze the patent situation from two perspectives:The overall situation and the technical level.Results and Conclusion At present,China’s medical device industry is developing rapidly under the leadership of enterprises as the main body of innovation,but only 16%of patents are authorized.In addition,the technology distribution of medical device industry is mainly related to diagnostic,surgical and identification medical devices and implantable devices,accounting for 59%of the main technology distribution,and their technical effects are mainly related to improving convenience,reducing complexity,and improving safety.The quality of patents related to medical device industry in China is low,the technology distribution is not rich enough,and the level of technical efficacy is low.展开更多
文摘Three-dimensional(3D)printing is a highly automated platform that facilitates material deposition in a layer-by-layer approach to fabricate pre-defined 3D complex structures on demand.It is a highly promising technique for the fabrication of personalized medical devices or even patient-specific tissue constructs.Each type of 3D printing technique has its unique advantages and limitations,and the selection of a suitable 3D printing technique is highly dependent on its intended application.In this review paper,we present and highlight some of the critical processes(printing parameters,build orientation,build location,and support structures),material(batch-to-batch consistency,recycling,protein adsorption,biocompatibility,and degradation properties),and regulatory considerations(sterility and mechanical properties)for 3D printing of personalized medical devices.The goal of this review paper is to provide the readers with a good understanding of the various key considerations(process,material,and regulatory)in 3D printing,which are critical for the fabrication of improved patient-specific 3D printed medical devices and tissue constructs.
文摘BACKGROUND An intrauterine device(IUD)is a contraceptive device placed in the uterine cavity and is a common contraceptive method for Chinese women.However,an IUD may cause complications due to placement time,intrauterine pressure and other factors.Ectopic IUDs are among the most serious complications.Ectopic IUDs are common in the myometrium and periuterine organs,and there are few reports of ectopic IUDs in the urinary bladder,especially in the anterior wall.CASE SUMMARY A 52-year-old woman was hospitalized due to a urinary bladder foreign body found via abdominal ultrasound and computed tomography(CT)examination.The patient had a 2-year history of recurrent abdominal distension and lower abdominal pain,accompanied by frequent urination,urgency,dysuria and other discomfort.Ultrasound examination revealed foreign bodies in the bladder cavity,with calculus on the surface of the foreign bodies.CT revealed a circular foreign body on the anterior wall of the urinary bladder,suggesting the possibility of an ectopic IUD.After laparoscopic exploration,an annular IUD was found in the anterior wall of urinary bladder,and an oval calculus with a diameter of approximately 2 cm was attached to the surface of the bladder cavity.The IUD and calculus were successfully and completely removed.The patient recovered well after surgery.CONCLUSION Abdominal ultrasound and CT are effective methods for detecting ectopic IUDs.The IUD is located in the urinary bladder and requires early surgical treatment.The choice of surgical method is determined by comprehensively considering the depth of the IUD in the bladder muscle layer,the situation of complicated calculus,the situation of intravesical inflammation and medical technology and equipment.
文摘Objective To explore and investigate a new treatment of releasing the risks and pain in removing intrauterine devices (IUD) from postmenopausal women. Methods Totally 240 postmenopausal women who needed to remove IUD were randomly divided into 3 groups. Group A (n =80) were preoperatively treated with 20 g/L vaginal testosterone propionate cod liver oil ointment (1 g/d) over a 2-week span of period, and vaginal misoprostol (200 μg) was one-time used at 2-3 h before operation. Group B (n =80) were treated with oral estradiol valerate (3 mg/d) from 7 d before operation. Other 80 women (group C) were treated with vaginal cod liver oil ointment (1 g/d) over a 2-week span of period before the operation day. The degree of cervical relaxation, operational difficulty, blood loss volume, the length of operation time and visual analogue scales (VAS) were evaluated, also the serum estradiol, testosterone and endometrial thickness were measured before and after medication. Results The degree of cervical relaxation, operational difficulty, blood loss, the length of operation time and VAS in group A were significantly better than those group C (P〈0.01), whiles its blood loss volume was less than group B (P〈0.05) and there were no significant differences in serum estradiol, testosterone and endometrial thickness before and after medication. Conclusion Preoperative vaginal testosterone propionate combined with misoprostol would reduce the operational difficulties/risks and release the suffering of patients. The study may represent a safe and effective alternative to remove IUD in postmeno- pausal women.
文摘The use of copper-containing intrauterine devices(Cu-IUDs)is a safe,effective,and long-term contraceptive method.Here,we review the effects of Cu-IUDs on subsequent pregnancy and the morphology,local coagulation function,sensitivity to estrogen and progesterone,cell proliferation,and immune response of the endometrium.Studies on the morphology of endometrium indicate that the use of Cu-IUDs can affect the number and binding capacity of estrogen and progesterone receptors in the endometrium and reduce the response of the endometrium to estrogen and progesterone.The use of Cu-IUDs can also affect the proliferation of endometrial cells,suggesting that the aseptic inflammation caused by Cu-IUDs may differ from chronic infectious or noninfectious inflammation;this highlights that the use of Cu-IUDs provides protection against endometrial proliferative diseases.The use of Cu-IUDs increases local endometrial angiogenesis,bleeding tendency,and fibrinolytic activity,which can result in prolonged menstruation or abnormal uterine bleeding.Additionally,the use of Cu-IUDs can cause the infiltration of numerous lymphocytes,monocytes,macrophages,and other inflammatory cells around the endometrial gland and changes in endometrial immune function,immune cell function,and the number and type of immune molecules.Cu-IUD-induced decidual injury significantly increases the invasiveness of trophoblasts,further affecting the aberrant expression of their growth-,angiogenesis-,and invasion-related factors and improving the formation of the placenta.Moreover,the endometrial damage caused by Cu-IUD placement before embryo transfer can improve both clinical pregnancy and live birth rates;however,specific changes in the immune system after Cu-IUD use as well as its effects on future pregnancies require further investigation.
基金supported by Public Service Platform of Science and Technology Projects in Data mining of contraceptives monitoring and research of risk assessment model(BM2012062)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘Objective To evaluate the cytotoxicity of six commonly used copper-bearing intrauterine devices (Cu-IUDs) on Chinese hamster ovary (CHO-K1) cells and to investigate the influence of frame, shape and copper surface area of Cu-IUDs on cell toxicity.Methods Cu-IUDs were incubated in 10% FBS-DMEM/F12 culture medium at 37 ℃ for 24 h. The extracts were analyzed by flame atomic absorption spectrometer and were then diluted into different concentrations with culture medium. Finally, cytotoxicity of these original and diluted extracts on CHO-K1 cells was detected by cell counting kit-8 (CCK-8) assay.Results The viabilities of cells treated with the original extracts of six Cu-IUDs (TCu220C bulb, TCu220C, GCu220, GCu300, Yuangong Cu270 and Yuangong Ⅱ- 300) were all below 10% and the cupric ion concentrations in these extracts were 28.22 mg/L, 31.80 mg/L, 92.80 mg/L, 99.74 mg/L, 114.90 mg/L and 119.20 mg/L, respectively. After these original extracts were diluted, significant differences in cytotoxicity were exhibited. IUDs with larger copper surface areas (GCu300 and Yuangong Ⅱ-300) showed more cytotoxicity than those with smaller areas (GCu220 and Yuangong Cu270) respectively; When different shapes of Cu-IUDs were compared, TCu220C bulb showed lower cytotoxicity than TCu220C, and GCu300 exhibited higher toxicity than Yuangong Ⅱ-300; TCu220C displayed significantly lower cytotoxicity than GCu220 due to their differences in frames.Conclusion We presented evidence on the cytotoxic effects of copper ions released from Cu-IUDs on CHO-K1 cells and found that shape, frame together with copper surface area of Cu-IUDs had obvious influence on the cytotoxicity.
文摘Objective: The aim of this study was to describe the use of the postpartum intrauterine device in the maternity ward of the Ratoma communal medical center in Conakry. Methods: This was a descriptive cross-sectional study carried out between July 1<sup>st</sup> 2015 and June 30 2016, i.e. a duration of one year. Results: A total of 551 patients received advice on various contraceptive methods. Most of this advice was given in the post-partum period (40.2%) and during antenatal care (39.1%). Of the patients advised, 87 (15.8%) used the intrauterine device. The majority of users (93%) were married and uneducated (63.2%), and 39.1% were poor. The majority (56.3%) of intra-uterine devices were inserted in the immediate post-partum period. The majority of women had no adverse events either during the first six weeks (n = 57;65.5%) or at 3<sup>rd</sup> months (n = 75;86.2%) or 6<sup>th</sup> months (n = 76;87.4%) after IUD insertion. Most users remained complication-free throughout the follow-up period (n = 76;87.4% at 6<sup>th</sup> weeks and 3<sup>rd</sup> months, and n = 77;88.5% at 6<sup>th</sup> months). The continuation rate was 89.7% at 6 weeks and 3<sup>rd</sup> months, and 87.4% at 6<sup>th</sup> months after insertion. The majority of users (87.0%) were satisfied with the care they received. Conclusion: This study showed very few complications among intrauterine device users, and high continuation and satisfaction rates. The intrauterine device is a long-acting, effective, reversible and safe contraceptive that can be used by most women for birth spacing in Guinea, where women do not regularly visit health facilities.
文摘Objective To study the patent situation of medical device industry in China based on patent data.Methods The analysis function of the patent search software incoPat was used to analyze the patent situation from two perspectives:The overall situation and the technical level.Results and Conclusion At present,China’s medical device industry is developing rapidly under the leadership of enterprises as the main body of innovation,but only 16%of patents are authorized.In addition,the technology distribution of medical device industry is mainly related to diagnostic,surgical and identification medical devices and implantable devices,accounting for 59%of the main technology distribution,and their technical effects are mainly related to improving convenience,reducing complexity,and improving safety.The quality of patents related to medical device industry in China is low,the technology distribution is not rich enough,and the level of technical efficacy is low.