This paper presents the studying results of the sodium ion sensor device based on the SnO_2/ITO glass structure in the detection of rinsing solution for contact lenses.The selective membrane contains poly (vinyl chlor...This paper presents the studying results of the sodium ion sensor device based on the SnO_2/ITO glass structure in the detection of rinsing solution for contact lenses.The selective membrane contains poly (vinyl chloride) (PVC),bis (2-ethylhexyl) sebacate (DOS),(12-crown-4) methylmalonate (B12C4),and sodium tetrakis (4-fluoropbenyl) borate dehydrate (NaTFBD). The final weight ratios are PVC:DOS:B12C4:NaTFBD=33:66:2:2.In this condition,the sensor has performances with linear sensitivity,short response time,good repeatability and selectivity.The sensor was used to measure the rinsing solution for the contact lenses.Because the experimental results show close to the accurate value for four commercial products,this sensor can preliminary be used in detecting the rinsing solution for the contact lenses.Using this structure and sodium-sensing membrane to construct the sodium sensor is proven successfully in this application.展开更多
A cobalt-iron alloy thin-film electrode-based electrochemical hydrogen-phosphate-ion sensor was prepared by electrodepositing on an Au-coated Al2O3 substrate from an aqueous solution of metal-salts. The use of a cobal...A cobalt-iron alloy thin-film electrode-based electrochemical hydrogen-phosphate-ion sensor was prepared by electrodepositing on an Au-coated Al2O3 substrate from an aqueous solution of metal-salts. The use of a cobalt-iron alloy electrode greatly improved the hydrogen-ion sensor response performance, i.e., the sensor worked stably for more than 7 weeks and showed a quick response time of several seconds. Among the cobalt and iron alloy systems tested, the electrodeposited Co58Fe42 thin-film electrode showed the best EMF response characteristics, i.e., the sensor exhibited a linear potentiometric response to hydrogen-phosphate ion at the concentration range between 1.0 × 10–5 and 1.0 × 10–2 M with the slope of –43 mV/decade at pH 5.0 and at 30℃. A sensing mechanism of the Co-based potentiometric hydrogen-phosphate ion sensor was proposed on the basis of results of instrumental analysis.展开更多
Conductive inks based on graphene materials have received significant attention for the fabrication of a wide range of printed and flexible devices.However,the application of graphene fillers is limited by their restr...Conductive inks based on graphene materials have received significant attention for the fabrication of a wide range of printed and flexible devices.However,the application of graphene fillers is limited by their restricted mass production and the low concentration of their suspensions.In this study,a highly concentrated and conductive ink based on defect-free graphene was developed by a scalable fluid dynamics process.A high shear exfoliation and mixing process enabled the production of graphene at a high concentration of 47.5 mg mL^(−1)for graphene ink.The screen-printed graphene conductor exhibits a high electrical conductivity of 1.49×10^(4)S m^(−1)and maintains high conductivity under mechanical bending,compressing,and fatigue tests.Based on the as-prepared graphene ink,a printed electrochemical sodium ion(Na^(+))sensor that shows high potentiometric sensing performance was fabricated.Further,by integrating a wireless electronic module,a prototype Na^(+)-sensing watch is demonstrated for the real-time monitoring of the sodium ion concentration in human sweat during the indoor exercise of a volunteer.The scalable and efficient procedure for the preparation of graphene ink presented in this work is very promising for the low-cost,reproducible,and large-scale printing of flexible and wearable electronic devices.展开更多
A novel and simple fluorescent molecular sensor,1-pyrenecarboxaldehyde thiosemicarbazone(Hpytsc),was synthesized.Its higher sensitivity and selectivity to mercury(Ⅱ) ion were studied through absorption and emissi...A novel and simple fluorescent molecular sensor,1-pyrenecarboxaldehyde thiosemicarbazone(Hpytsc),was synthesized.Its higher sensitivity and selectivity to mercury(Ⅱ) ion were studied through absorption and emission channels.The UV-vis spectra show that the increasing mercury(Ⅱ) ion concentrations result in the decreasing absorption intensity.The fluorescence monomer emission of Hpytsc is enhanced upon binding mercury(Ⅱ) ion,which should be due to the 1:1 complex formation between Hpytsc and metal ion.展开更多
In order to examine the hydronium ion (proton)-releasing functions in cells, [pH]out (extracellular pH) was measured using an ion image sensor composed of a 2D (two-dimensional) array of potential sensitive pixe...In order to examine the hydronium ion (proton)-releasing functions in cells, [pH]out (extracellular pH) was measured using an ion image sensor composed of a 2D (two-dimensional) array of potential sensitive pixels. Using gastric tissues prepared from the stomach, pH distribution was observed during the histamine stimulation. The 2D distribution of [pH]out in the gastric tissues showed clear differences between the mucosal sides and the serous side. Even before the histamine stimulation, the mucosal side of the gastric mucosa showed a slightly lower pH than that of serous side. In the mucosal side, [pH]out decreased after the onset of the stimulation. The ion image sensor was capable of visualizing [pH]out in the gastric tissues. The present chemical-sensing technique realized a label-free microscopic assessment of the 2D distributions of biologically interesting substances, and consequently, [pH] out imaging via chemical microscopy has a future potential in medical fields for endoscopic analysis of gastric ulcers.展开更多
An electrochemical sensor incorporating a signal enhancement for the determination of lead (II) ions (Pb2+) was designed on the basis of the thrombin-binding aptamer (TBA) as a molecular recog- nition element a...An electrochemical sensor incorporating a signal enhancement for the determination of lead (II) ions (Pb2+) was designed on the basis of the thrombin-binding aptamer (TBA) as a molecular recog- nition element and ionic liquid supported cerium oxide (CeO2) nanoparticles-carbon nanotubes compo- site modification. The composite comprises nanoparticles CeO2, multi-waU carbon nanotubes (MWNTs) and hydrophobic room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIMBF4). The electrochemical sensors were fabricated by immersing the CeOa-MWNTs-EMIMBF4 modified glassy carbon electrode (GCE) into the solution of TBA probe. In the presence of Pb2+, the TBA probe could form stable G-quartet structure by the specific binding interactions between Pb2+ and TBA. The TBA-bound Pb2+ can be electrochemically reduced, which provides a readout signal for quantitative detection of Pb2+. The reduction peak current is linearly related to the concentration of Pb2+ from 1.0 * 10-8 M to 1.0 * 105 M with a detection limit of 5 * 109 M. This work demonstrates that the CeOz-MWNTs-EMIMBF4 nanocomposite modified GCE provides a promising platform for immobi- lizing the TBA probe and enhancing the sensitivity of the DNA-based sensors.展开更多
A piezoelectric sensor responsive to vitamin B 1 was fabricated based on the vitamin B 1 tetraphenylborate ion pair. The general performance characteristics of the sensor are presented here. The proposed sensor sho...A piezoelectric sensor responsive to vitamin B 1 was fabricated based on the vitamin B 1 tetraphenylborate ion pair. The general performance characteristics of the sensor are presented here. The proposed sensor showed a wide working pH range, a good sensitivity and selectivity. The response range is between 1 0×10 -7 -4 9×10 -5 mol/L with a detection limit of 8×10 -8 mol/L at pH 4 0. The selectivity should be attributed to the preferential adsorption of the component ion on the membrane/solution interface. The adsorption behavior of vitamin B 1 on the crystal surface was investigated with a quartz crystal impedance(QCI) system.展开更多
A novel chemiluminescence (CL) sensor for NH4+ combined with flow injection analysis is presented in this paper. It is based on the inhibition effect of NH4+ on the CL reaction between luminol, immobilized electrostat...A novel chemiluminescence (CL) sensor for NH4+ combined with flow injection analysis is presented in this paper. It is based on the inhibition effect of NH4+ on the CL reaction between luminol, immobilized electrostatically on an anion-exchange column, and hypochlorous acid electrogenerated on-line. The sensor responds linearly to NH4+ concentration in 1.0x10(-6)-4.0x10(-9) g/ml range. A complete analysis could be performed in 1 min. The system is stable for 200 determination.展开更多
文摘This paper presents the studying results of the sodium ion sensor device based on the SnO_2/ITO glass structure in the detection of rinsing solution for contact lenses.The selective membrane contains poly (vinyl chloride) (PVC),bis (2-ethylhexyl) sebacate (DOS),(12-crown-4) methylmalonate (B12C4),and sodium tetrakis (4-fluoropbenyl) borate dehydrate (NaTFBD). The final weight ratios are PVC:DOS:B12C4:NaTFBD=33:66:2:2.In this condition,the sensor has performances with linear sensitivity,short response time,good repeatability and selectivity.The sensor was used to measure the rinsing solution for the contact lenses.Because the experimental results show close to the accurate value for four commercial products,this sensor can preliminary be used in detecting the rinsing solution for the contact lenses.Using this structure and sodium-sensing membrane to construct the sodium sensor is proven successfully in this application.
文摘A cobalt-iron alloy thin-film electrode-based electrochemical hydrogen-phosphate-ion sensor was prepared by electrodepositing on an Au-coated Al2O3 substrate from an aqueous solution of metal-salts. The use of a cobalt-iron alloy electrode greatly improved the hydrogen-ion sensor response performance, i.e., the sensor worked stably for more than 7 weeks and showed a quick response time of several seconds. Among the cobalt and iron alloy systems tested, the electrodeposited Co58Fe42 thin-film electrode showed the best EMF response characteristics, i.e., the sensor exhibited a linear potentiometric response to hydrogen-phosphate ion at the concentration range between 1.0 × 10–5 and 1.0 × 10–2 M with the slope of –43 mV/decade at pH 5.0 and at 30℃. A sensing mechanism of the Co-based potentiometric hydrogen-phosphate ion sensor was proposed on the basis of results of instrumental analysis.
基金the National Research Foundation of Korea(NRF)Grant funded by the Ministry of Science and ICT(No.2021R1A2C1009926)“Basic project(referring to projects performed with the budget directly contributed by the Government to achieve the purposes of establishment of Government-funded research Institutes)”+3 种基金supported by the KOREA RESEARCH INSTITUTE of CHEMICAL TECHNOLOGY(KRICT)(SS2042-10)Basic research project(Project:21-3212-1)of the Korea institute of GeoscienceMineral resources funded by the Ministry of Science and ICT of Koreaby Nanomedical Devices Development Project of NNFC in 2021.
文摘Conductive inks based on graphene materials have received significant attention for the fabrication of a wide range of printed and flexible devices.However,the application of graphene fillers is limited by their restricted mass production and the low concentration of their suspensions.In this study,a highly concentrated and conductive ink based on defect-free graphene was developed by a scalable fluid dynamics process.A high shear exfoliation and mixing process enabled the production of graphene at a high concentration of 47.5 mg mL^(−1)for graphene ink.The screen-printed graphene conductor exhibits a high electrical conductivity of 1.49×10^(4)S m^(−1)and maintains high conductivity under mechanical bending,compressing,and fatigue tests.Based on the as-prepared graphene ink,a printed electrochemical sodium ion(Na^(+))sensor that shows high potentiometric sensing performance was fabricated.Further,by integrating a wireless electronic module,a prototype Na^(+)-sensing watch is demonstrated for the real-time monitoring of the sodium ion concentration in human sweat during the indoor exercise of a volunteer.The scalable and efficient procedure for the preparation of graphene ink presented in this work is very promising for the low-cost,reproducible,and large-scale printing of flexible and wearable electronic devices.
基金the Natural Science Foundation of Shaanxi Province,the Special Foundation of the Education Department of Shaanxi Province,the Special Research Fund of Xianyang Normal University for Talent Introduction
基金financed by the Graduate Innovation Foundation of Logistic Engineering University(Chongqing, China)
文摘A novel and simple fluorescent molecular sensor,1-pyrenecarboxaldehyde thiosemicarbazone(Hpytsc),was synthesized.Its higher sensitivity and selectivity to mercury(Ⅱ) ion were studied through absorption and emission channels.The UV-vis spectra show that the increasing mercury(Ⅱ) ion concentrations result in the decreasing absorption intensity.The fluorescence monomer emission of Hpytsc is enhanced upon binding mercury(Ⅱ) ion,which should be due to the 1:1 complex formation between Hpytsc and metal ion.
文摘In order to examine the hydronium ion (proton)-releasing functions in cells, [pH]out (extracellular pH) was measured using an ion image sensor composed of a 2D (two-dimensional) array of potential sensitive pixels. Using gastric tissues prepared from the stomach, pH distribution was observed during the histamine stimulation. The 2D distribution of [pH]out in the gastric tissues showed clear differences between the mucosal sides and the serous side. Even before the histamine stimulation, the mucosal side of the gastric mucosa showed a slightly lower pH than that of serous side. In the mucosal side, [pH]out decreased after the onset of the stimulation. The ion image sensor was capable of visualizing [pH]out in the gastric tissues. The present chemical-sensing technique realized a label-free microscopic assessment of the 2D distributions of biologically interesting substances, and consequently, [pH] out imaging via chemical microscopy has a future potential in medical fields for endoscopic analysis of gastric ulcers.
基金supports from the National Science Foundations of China (Nos. 20875076 and 21005061)the Specialized Research Fund for the Doctoral Program of Higher Education of China (No. 20096101120011)+2 种基金the Natural Science Basic Research Plan in Shaanxi Province of China (No.2010JQ2013)the Education Department of Shaanxi Province,China (No. 09JK759)the NWU Graduate Innovation and Creativity Funds (No. 09YSY04)
文摘An electrochemical sensor incorporating a signal enhancement for the determination of lead (II) ions (Pb2+) was designed on the basis of the thrombin-binding aptamer (TBA) as a molecular recog- nition element and ionic liquid supported cerium oxide (CeO2) nanoparticles-carbon nanotubes compo- site modification. The composite comprises nanoparticles CeO2, multi-waU carbon nanotubes (MWNTs) and hydrophobic room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIMBF4). The electrochemical sensors were fabricated by immersing the CeOa-MWNTs-EMIMBF4 modified glassy carbon electrode (GCE) into the solution of TBA probe. In the presence of Pb2+, the TBA probe could form stable G-quartet structure by the specific binding interactions between Pb2+ and TBA. The TBA-bound Pb2+ can be electrochemically reduced, which provides a readout signal for quantitative detection of Pb2+. The reduction peak current is linearly related to the concentration of Pb2+ from 1.0 * 10-8 M to 1.0 * 105 M with a detection limit of 5 * 109 M. This work demonstrates that the CeOz-MWNTs-EMIMBF4 nanocomposite modified GCE provides a promising platform for immobi- lizing the TBA probe and enhancing the sensitivity of the DNA-based sensors.
基金Supported by the National Natural Science Foundation of China( No.2 0 0 75 0 0 7)
文摘A piezoelectric sensor responsive to vitamin B 1 was fabricated based on the vitamin B 1 tetraphenylborate ion pair. The general performance characteristics of the sensor are presented here. The proposed sensor showed a wide working pH range, a good sensitivity and selectivity. The response range is between 1 0×10 -7 -4 9×10 -5 mol/L with a detection limit of 8×10 -8 mol/L at pH 4 0. The selectivity should be attributed to the preferential adsorption of the component ion on the membrane/solution interface. The adsorption behavior of vitamin B 1 on the crystal surface was investigated with a quartz crystal impedance(QCI) system.
文摘A novel chemiluminescence (CL) sensor for NH4+ combined with flow injection analysis is presented in this paper. It is based on the inhibition effect of NH4+ on the CL reaction between luminol, immobilized electrostatically on an anion-exchange column, and hypochlorous acid electrogenerated on-line. The sensor responds linearly to NH4+ concentration in 1.0x10(-6)-4.0x10(-9) g/ml range. A complete analysis could be performed in 1 min. The system is stable for 200 determination.