期刊文献+
共找到23,355篇文章
< 1 2 250 >
每页显示 20 50 100
Additive manufactured osseointegrated screws with hierarchical design
1
作者 Wenbo Yang Hao Chen +6 位作者 Haotian Bai Yifu Sun Aobo Zhang Yang Liu Yuchao Song Qing Han Jincheng Wang 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第2期206-235,共30页
Bone screws are devices used to fix implants or bones to bones.However,conventional screws are mechanically fixed with thread and often face long-term failure due to poor osseointegration.To improve osseointegration,s... Bone screws are devices used to fix implants or bones to bones.However,conventional screws are mechanically fixed with thread and often face long-term failure due to poor osseointegration.To improve osseointegration,screws are evolving from solid and smooth to porous and rough.Additive manufacturing(AM)offers a high degree of manufacturing freedom,enabling the preparation of predesigned screws that are porous and rough.This paper provides an overview of the problems currently faced by bone screws:long-term loosening and screw breakage.Next,advances in osseointegrated screws are summarized hierarchically(sub-micro,micro,and macro).At the sub-microscale level,we describe surface-modification techniques for enhancing osseointegration.At the micro level,we summarize the micro-design parameters that affect the mechanical and biological properties of porous osseointegrated screws,including porosity,pore size,and pore shape.In addition,we highlight three promising pore shapes:triply periodic minimal surface,auxetic structure with negative Poisson ratio,and the Voronoi structure.At the macro level,we outline the strategies of graded design,gradient design,and topology optimization design to improve the mechanical strength of porous osseointegrated screws.Simultaneously,this paper outlines advances in AM technology for enhancing the mechanical properties of porous osseointegrated screws.AM osseointegrated screws with hierarchical design are expected to provide excellent long-term fixation and the required mechanical strength. 展开更多
关键词 Bone screws Additive manufacturing Architecture design Surface modification
下载PDF
Roller Screw and Threaded Chain Speed Reducer: An Experimental Evaluation
2
作者 Filiberto Gutiérrez 《Modern Mechanical Engineering》 2024年第1期1-11,共11页
We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuratio... We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuration lessens wear, increases load capacity, and improves efficiency. The threaded chain consists of nut-shaped links. This paper presents the results of tests carried out on a prototype with a reduction ratio of 46. 展开更多
关键词 Speed Reducer Inverted Roller screw Chain Drive Threaded Chain Drive
下载PDF
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
3
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Distal clavicle fractures treated by anteroinferior plating with a single screw: Two case reports 被引量:1
4
作者 Xin-Lei Zhao Yan-Qing Liu +4 位作者 Jian-Guo Wang You-Cai Liu Jia-Xuan Zhou Bei-Yu Wang Yi-Jun Zhang 《World Journal of Clinical Cases》 SCIE 2023年第30期7502-7507,共6页
BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal... BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal clavicle fractures treated utilizing an anterior inferior plate with a single screw placed in the distal,in anticipation of providing a better surgical approach to distal clavicle fracture treatment.Two patients were admitted to the hospital after trauma with a diagnosis of distal clavicle fracture,and were admitted to the hospital for internal fixation of clavicle fracture by incision and reduction,with good postoperative functional recovery.CONCLUSION With solid postoperative fixation and satisfactory prognostic functional recovery,this technique has been shown to be simple,easy to perform and effective. 展开更多
关键词 Distal clavicle fractures Anteroinferior PLATING Single screw Case report
下载PDF
Multitrack and multianchor point screw technique combined with the Wiltse approach for lesion debridement for lumbar tuberculosis
5
作者 Yu-Fei Yuan Zhi-Xin Ren +5 位作者 Cun Zhang Guan-Jun Li Bing-Zhi Liu Xiao-Dong Li Jie Miao Jian-Fei Li 《World Journal of Clinical Cases》 SCIE 2023年第14期3167-3175,共9页
BACKGROUND The incidence of lumbar tuberculosis is high worldwide,and effective treatment is a continuing problem.AIM To study the safety and efficacy of the multitrack and multianchor point screw technique combined w... BACKGROUND The incidence of lumbar tuberculosis is high worldwide,and effective treatment is a continuing problem.AIM To study the safety and efficacy of the multitrack and multianchor point screw technique combined with the contralateral Wiltse approach for lesion debridement to treat lumbar tuberculosis.METHODS The C-reactive protein(CRP)level,erythrocyte sedimentation rate(ESR),visual analogue scale(VAS)score,oswestry disability index(ODI)and American Spinal Injury Association(ASIA)grade were recorded and analysed pre-and postoperatively.RESULTS The CRP level and ESR returned to normal,and the VAS score and ODI were decreased at 3 mo postoperatively,with significant differences compared with the preoperative values(P<0.01).Neurological dysfunction was relieved,and the ASIA grade increased,with no adverse events.CONCLUSION The multitrack,multianchor point screw fixation technique combined with the contralateral Wiltse approach for debridement is an effective and safe method for the treatment of lumbar tuberculosis. 展开更多
关键词 Lumbar spine TUBERCULOSIS DEBRIDEMENT Pedicle screw Cortical bone trajectory screw Wiltse approach
下载PDF
Gravity-Based Kinetostatic Modeling of Parallel Manipulators Using Screw Theory
6
作者 Chao Yang Fengli Huang +1 位作者 Wei Ye Qiaohong Chen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第6期73-86,共14页
The pose accuracy of parallel manipulators(PMs)is a key index to measure their performance.Establishing the grav-ity-based kinetostatic model of a parallel robot provides an important basis for its error composition a... The pose accuracy of parallel manipulators(PMs)is a key index to measure their performance.Establishing the grav-ity-based kinetostatic model of a parallel robot provides an important basis for its error composition and accuracy improvement.In this paper,a kinetostatic modeling approach that takes real gravity distribution into consideration is proposed to analyze the influence of gravity on the infinitesimal twist and actuator forces of PMs.First,the duality of the twist screw and constraint wrenches are used to derive the gravity-attached constraint wrenches independent of the external load and the limb stiffness matrix corresponding to the kinematics-based constraint wrenches.Sec-ond,the gravity model of the mechanism is established based on the screw theory and the principle of virtual work.Finally,the analytical formulas of the infinitesimal twist and the actuator force of PMs are obtained,and the influences of the external load,platform gravity,and rod gravity on the stiffness of the mechanism are decoupled.The non-overconstrained 3RPS and overconstrained 2PRU-UPR PMs are taken as examples to verify the proposed method.This research proposes a methodology to analyze the infinitesimal deformation of the mechanism under the influence of gravity. 展开更多
关键词 Parallel manipulator Kinetostatic model GRAVITY screw theory
下载PDF
Experimental Investigation on the Strength and Ductility Performance of Steel-Timber-Steel Joints with Screw and Steel-Tube Fasteners
7
作者 Huifeng Yang Mingwang Wu +3 位作者 Rixin Gu Hang Cao Kai Xiao Benkai Shi 《Journal of Renewable Materials》 EI 2023年第12期4175-4195,共21页
This article presents experimental results of steel-timber-steel(STS)joints loaded parallel to grain.Eight groups of specimens were designed,and tensile tests were performed.The fastener types and fastener numbers wer... This article presents experimental results of steel-timber-steel(STS)joints loaded parallel to grain.Eight groups of specimens were designed,and tensile tests were performed.The fastener types and fastener numbers were considered to evaluate the tensile strengths and ductility performances of the STS joints.The screws with 6 mm diameter and the innovative steel-tubes with 18 mm diameter were adopted as connecting fasteners.The experimental results were discussed in terms of yielding and ultimate strengths,slip stiffness,and ductility factors.The ductility classification and failure mechanisms of each group of specimens were analyzed.It was demonstrated that the STS joint with large diameter steel-tubes showed acceptable ductility,which was close to the ductility of the STS joint with small diameter screws,thanks to the hollow structure of the steel-tube.The theoretical strengths of various failure modes for the joints with small diameter screws or large diameter steel-tubes were calculated and compared with the experimental results.The ductile performance of the STS joint was discussed by comparing the theoretical strengths of various failure modes.The effective number of the STS joint with multifasteners was also analyzed by considering the failure mechanisms in aspects of tensile strength and slip stiffness. 展开更多
关键词 Steel-timber-steel joint screw steel-tube DUCTILITY experimental investigation timber structure
下载PDF
Management of Isolated Coronal Fractures of Distal Humeral Epiphysis by Herbert Screw
8
作者 Yassine Ben Bouzid Rida-Allah Bassir +4 位作者 Monsef Boufettal Jalal Mekkaoui Mohamed Kharmaz Moulay Omar Lamrani Mohamed Saleh Berrada 《Open Journal of Orthopedics》 2023年第2期50-54,共5页
Isolated fractures of the distal humerus are rare. Their diagnosis is often late, and treatment has progressed but serious complications may occur. We conducted a retrospective study of a series of 10 cases at the Dep... Isolated fractures of the distal humerus are rare. Their diagnosis is often late, and treatment has progressed but serious complications may occur. We conducted a retrospective study of a series of 10 cases at the Department of Orthopedic and Traumatologic Surgery of the Ibn Sina University Hospital in Rabat over a 4-year period, from January 2018 to January 2022. All our cases were treated surgically with Herbert screws. The functional, clinical and radiological outcome was satisfactory with a return to pre-fracture activity in all patients. 展开更多
关键词 Elbow CAPITELLUM Herbert screw
下载PDF
Nail Holding Performance of Self-Tapping Screws on Masson Pine and Chinese Fir Dimension Lumbers
9
作者 De Li Bengang Zhang +7 位作者 Yuan Tu Guoming Xiao Meifen Tian Xiaoxue Xu Xiao Zhong Qiaoyan Zhang Zhigang Wu Jiankun Liang 《Journal of Renewable Materials》 EI 2023年第10期3725-3738,共14页
Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects o... Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects of the diameter of the self-tapping screw and the guiding bores on the nail holding performance on different sections of Masson pine and Chinese fir dimension lumbers were mainly explored.The results showed that:(1)The nail holding strength of the tangential section was the maximum,followed by that of the radial section,and that of the cross section was the minimum.(2)The nail holding strength of Masson pine was higher than that of Chinese fir.(3)The nail holding strength grew with the increase in the diameter of self-tapping screws,but a large diameter would lead to plastic cracking of the timber,thus further affecting the nail holding strength.Masson pine and Chinese fir reached the maximum nail holding strength when the diameter of self-tapping screws was 3.5 mm.(4)Under a large diameter of screws,prefabricated guiding bores could mitigate timber cracking and improve its nail holding strength.(5)Prefabricated guiding bores were more necessary for the screw connection of Masson pine.The results obtained could provide a scientific basis for the screw connection design of Masson pine and Chinese fir timber structures. 展开更多
关键词 Masson pine Chinese fir self-tapping screws nail holding performance
下载PDF
Crossed Intralaminar Screws for Fusion of the Cervicothoracic Junction and the Thoracic Spine: The Experience in an Iberic Service with Case Series and Review of the Current Literature with Technique Description
10
作者 Marcel Sincari Margarida Conceição 《Surgical Science》 2023年第3期203-220,共18页
The treatment of pathologies in the thoracic spine is a challenge. The periodic failure of pedicle screw insertion and anatomical variations make the search for an alternative to pedicle screws in thoracic spine surge... The treatment of pathologies in the thoracic spine is a challenge. The periodic failure of pedicle screw insertion and anatomical variations make the search for an alternative to pedicle screws in thoracic spine surgery necessary. The interlaminar crossed screws is a well-known and secure method for fusion in cervical spine, and in thoracic spine there used to be insufficient clinical data to support this technique, until now. We demonstrate in an initial series of 10 cases treated with interlaminar fusion in association of other fusion techniques in the thoracic spine with good results. Objective: Intralaminar screws have been shown to be a biomechanical salvage technique in the thoracic spine, especially in long cervicothoracic, thoracic and thoracolumbar fixation. The goals of this article are to demonstrate our initial experience and the range of indications for thoracic crossed intralaminar screws. Methods: In this article we describe our initial series performed at S&#227o Teot&#243nio Hospital in Viseu, Portugal, and our results, and also provide a comprehensive review of the recent literature in the use of intralaminar crossed fixation. 展开更多
关键词 Crossed Intralaminar Spinolaminar Angle THORACIC Imaging Lamina screws Spinal Fusion/Instrumentation/Methods Thoracic Vertebrae
下载PDF
Accuracy of screw placement in the apical region of Lenke 1 adolescent idiopathic scoliosis surgery using a calibration technique for the intraoperative navigation error
11
作者 CHEN Huan-xiong HE Xian-bo +6 位作者 LI Guo-jun TANG Song-jie ZHONG Zhen-hao HUANG Tao LIN You-cai LIN Su-yu MENG Zhi-bin 《Journal of Hainan Medical University》 CAS 2023年第6期43-50,共8页
Objective:To study the position and the grade of screw perforation in the apical region of adolescent idiopathic scoliosis(AIS)surgery using a calibration technique for the intraoperative navigation error,and to analy... Objective:To study the position and the grade of screw perforation in the apical region of adolescent idiopathic scoliosis(AIS)surgery using a calibration technique for the intraoperative navigation error,and to analyze the related factors of navigation deviation and the clinical significance of the calibration technique.Methods:From 2017 to 2020,a total of 60 Lenke 1 AIS surgical cases were enrolled in this research.The 30 cases received surgery using the intraoperative navigation system(Navigation group)and another 30 cases were assisted with intraoperative navigation system with calibration technique(Calibration group)for the intraoperative navigation error.The basic information and radiological data of the both groups were all recorded.According to the Fu Chang-feng’s pedicle channel classification system,the pedicle on the apical region of the two groups was classified.And then the accuracy of screw placement of the two groups was evaluated according to the Rao’s classification.Results:A total of 600 screws were placed in the two groups.The 297 and 303 pedicle screws were implanted in the navigation group and the calibration group,respectively.In the apical region of the calibration group,the rates of the grade 0 screw placement in type A,B and C pedicle were 95.7%,86.7%and 68.9%respectively.It was a statistically significant difference from the 73.9%,66.9%and 30.0%in the navigation group respectively(P<0.05).In the calibration group,the rates of the medial cortical perforation in the type A,B,C and D pedicle were 0%,1.6%,1.6%and 0%,respectively.The corresponding rates were 16.3%,16.9%,30.0%and 47.6%in the navigation group,respectively.Moreover,in the concave side of the apical region of the calibration group,the rates of the medial cortical perforation in the type A,B,C and D pedicle were 0%,3.6%,2.6%and 0%,respectively.Compared with the calibration group,the corresponding rates were higher in the navigation group(34.4%,25.9%,37.2%and 60.0%,respectively).No serious complications such as spinal cord or neurovascular injury occurred for the two groups.Conclusion:Compared with the intraoperative navigation system,the calibration technique for the intraoperative navigation error could provide the higher accuracy of pedicle screw placement in the apical region of the major curve,the lower medial cortical perforation rate,the less screws misplacement rate on the concave side and the less complication rate of the severe Lenke 1 AIS patients. 展开更多
关键词 Adolescent idiopathic scoliosis Apical region Pedicle channel classification Pedicle screw Navigation error
下载PDF
Research and experimental analysis of precision degradation method based on the ball screw mechanism
12
作者 孔德顺 GAO Xiangsheng JIANG Huizeng 《High Technology Letters》 EI CAS 2023年第3期247-256,共10页
As a key transmission component in computer numerical control(CNC) machine tools,the ball screw mechanism(BSM) is usually investigated under working load conditions. Its accuracy degradation process is relatively long... As a key transmission component in computer numerical control(CNC) machine tools,the ball screw mechanism(BSM) is usually investigated under working load conditions. Its accuracy degradation process is relatively long,which is not conducive to the design and development of new products. In this paper,the normal wear depth of the BSM nut raceway is calculated under the variable speed operation condition using the fractal wear analysis method and the BSM’s accelerated degradation proportional wear model. Parameters of the acceleration degradation model of the double-nut preloaded ball screw pair are calculated based on the physical simulation results. The accelerated degradation test platform of the BSM is designed and manufactured to calculate the raceway wear model when the lubrication condition is broken under the variable-speed inertial load and the boundary lubrication condition under the uniform speed state. Three load forces and two samples are selected for the accelerated degradation test of the BSM. The measured friction torque of the BSM is employed as the evaluation index of the accuracy degradation test. In addition,the life cycle of the accuracy retention is accurately calculated by employing the parameters of the physical simulation model of the BSM. The calculations mentioned above can be used to estimate BSM’s accuracy performance degradation law under normal operating conditions. The application of the proposed model provides a new research method for researching the precision retention of the BSM. 展开更多
关键词 ball screw mechanism(BSM) fractal theory wear model accelerated degradation method friction torque precision retention
下载PDF
Fixation of Calcaneal Tuberosity Beavis II Fracture in Elderly Patients Using Locking Plate Combined with Tension Screw
13
作者 De-Jian Li Jia-Wen He +2 位作者 Jian-Hua Zhou Cheng-Qing Yi Qi-Kai Huang 《Biomedical Engineering Communications》 2023年第1期24-28,共5页
Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.B... Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.Beavis II fracture has large bone fracture,obvious displacement,obvious soft tissue irritation,and often leads to skin necrosis.It needs surgical treatment,reduction and fixation as soon as possible.Although open reduction and tension screw internal fixation is used for Beavis II calcaneal tubercle fracture,but the failure rate is more common.Methods:This study retrospectively analyzed the surgical treatment of calcaneal tubercle Beavis II fracture over 55 years old in our hospital from January 2013 to January 2019.The patients were treated with tension screw combined with locking plate,and followed up and analyzed.Results:12 patients in this group were followed up for 12 to 36 months(mean 20 months).After operation,the fracture healed smoothly in all patients,the healing time was 8 to 12 weeks(mean 10.7 weeks),and there were no complications such as poor incision healing,fracture displacement,internal fixation loosening,fracture and so on.When the patients were followed up 18 weeks after operation,the AOFAS score was 47 to 100,with an average of 91.1,of which 8 cases were excellent,3 good and 1 poor,with an excellent and good rate of 91.7%.Conclusion:Our hospital has been treated with tension screw combined with locking plate,fixed firmly,can early functional exercise,achieved good results. 展开更多
关键词 calcaneal tubercle Beavis II fracture locking plate tension screw elderly patients
下载PDF
骨科机器人联合Starr骨盆复位架治疗Tile C型骨盆环骨折 被引量:1
14
作者 姜刚强 焦福德 +3 位作者 应霁翀 虞天明 刘建磊 庄云强 《中国骨伤》 CAS CSCD 2024年第5期445-450,共6页
目的:探讨骨科机器人联合Starr骨盆复位架治疗Tile C型骨盆环骨折的临床疗效。方法:2019年10月至2021年5月采用机器人联合Starr骨盆复位架治疗14例Tile C型骨盆环骨折患者,男9例,女5例;年龄33~69岁。14例患者均为新鲜闭合骨折且不合并... 目的:探讨骨科机器人联合Starr骨盆复位架治疗Tile C型骨盆环骨折的临床疗效。方法:2019年10月至2021年5月采用机器人联合Starr骨盆复位架治疗14例Tile C型骨盆环骨折患者,男9例,女5例;年龄33~69岁。14例患者均为新鲜闭合骨折且不合并股骨、胫腓骨骨折等损伤。入院后4~7 d完成手术,术中在可透视碳素床,通过Starr骨盆复位架牵引复位骨盆环,联合骨科机器人治疗C型骨盆环骨折。观察手术时间、出血量、单枚螺钉置入透视次数、骨折复位质量、患肢功能及并发症等。采用Matta评分标准进行放射学复位评价,末次随访采用Majeed骨盆功能评分系统进行临床疗效评价。结果:14例患者均顺利完成手术,手术时间84~141 min,手术出血量20~50 ml,单枚螺钉置入透视次数4~9次。14例患者均获得随访,随访时间12~24个月。术后所有骨折获得骨性愈合,愈合时间3~7个月,未发现内固定断裂、螺钉松动、感染、神经损伤等并发症。依据Matta影像学复位评估标准:优9例,良4例,可1例。末次随访采用Majeed骨盆功能评分系统:优10例,良4例。结论:机器人联合Starr骨盆复位架治疗C型骨盆环新鲜骨折操作简单、缩短了手术和麻醉时间、并发症少,降低了手术风险,实现了骨盆骨折的微创治疗。但对于陈旧性骨折,因骨折复位困难,该技术并不适用。对于螺钉进钉点区域粉碎的骨折,通道螺钉置入困难,建议采用其他方式固定。对于伴有骨盆外伤史或骨盆发育异常者,术前需仔细评估有无经皮螺钉通道,避免损伤神经、血管。 展开更多
关键词 骨科机器人 Starr骨盆复位架 骨盆骨折 螺钉 内固定
下载PDF
两种内固定治疗股骨颈骨折的疗效比较 被引量:3
15
作者 梅伟 洪博文 丁亮 《临床骨科杂志》 2024年第1期75-78,共4页
目的比较空心加压螺钉(CCS)和股骨颈动力交叉钉系统(FNS)固定治疗股骨颈骨折的疗效。方法将42例股骨颈骨折患者按照内固定方式不同分为FNS组(采用FNS固定治疗,15例)和CCS组(采用CCS固定治疗,27例)。比较两组切口长度、术中出血量、术中... 目的比较空心加压螺钉(CCS)和股骨颈动力交叉钉系统(FNS)固定治疗股骨颈骨折的疗效。方法将42例股骨颈骨折患者按照内固定方式不同分为FNS组(采用FNS固定治疗,15例)和CCS组(采用CCS固定治疗,27例)。比较两组切口长度、术中出血量、术中透视次数、手术时间、术后住院时间、并发症发生情况、下地时间、骨折愈合时间、步态情况。结果患者均获得随访,时间12~14个月。切口长度CCS组短于FNS组(P<0.05);术中透视次数、手术时间FNS组少(短)于CCS组(P<0.05);术中出血量、术后住院时间两组比较差异均无统计学意义(P>0.05)。两组均无切口感染、骨折不愈合等并发症发生;术后约3个月CCS组2例出现CCS松动及退钉现象,经减少活动后未影响骨折愈合。下地部分负重时间、骨折愈合时间FNS组均短于CCS组(P<0.05)。末次随访时两组患者均可部分负重行走。结论与CCS固定相比,FNS固定治疗股骨颈骨折术中透视次数少、手术时间短,且固定稳定、牢靠,在“早活动、晚负重”原则下利于患肢功能锻炼,更有助于促进骨折愈合。 展开更多
关键词 股骨颈动力交叉钉系统 空心加压螺钉 股骨颈骨折
下载PDF
双螺带式搅拌器的搅拌特性及关键结构参数研究 被引量:1
16
作者 曾真 李振南 +2 位作者 唐涛 宋春晗 郑小涛 《饲料工业》 CAS 北大核心 2024年第12期38-44,共7页
运用Fluent软件对双螺带搅拌器的混合过程进行模拟,利用多功能搅拌实验平台进行功耗测试,验证仿真模型的合理性。结合实例,分析了边界间隙、螺带直径以及螺距对搅拌特性的影响。针对混合效果和效率(经济功耗)的定量评价难点,提出用功耗... 运用Fluent软件对双螺带搅拌器的混合过程进行模拟,利用多功能搅拌实验平台进行功耗测试,验证仿真模型的合理性。结合实例,分析了边界间隙、螺带直径以及螺距对搅拌特性的影响。针对混合效果和效率(经济功耗)的定量评价难点,提出用功耗因子与轴向功耗因子的数值,表征高黏度流体混合时的能量利用效果与整体混合效果,并以此为依据对螺带式搅拌器关键几何参数进行优化。实例的模拟结果表明:当螺带直径为1 200 mm时,即螺带直径达到罐体直径0.8倍时,轴向功耗因子最大为0.232 6 s,表明轴向流体宏观混合效果最好;螺距为1 350 mm时,即螺距与螺带直径之比为1(螺旋升角为45°)时,轴向功耗因子达到最大为0.180 6 s,表明轴向流体宏观混合效果最好;随着边界间隙的减小,罐壁总速度峰值增大,表明防附着效果增强,罐壁内侧的热边界层减薄。 展开更多
关键词 螺带式搅拌器 搅拌特性 模拟 结构优化 能量分配
下载PDF
新型棘突间撑开融合装置BacFuse修复腰椎退行性病的生物力学特征 被引量:1
17
作者 陈萌萌 包利 +4 位作者 陈浩 贾璞 冯飞 侍管 唐海 《中国组织工程研究》 CAS 北大核心 2024年第9期1325-1329,共5页
背景:近年来,棘突间撑开融合装置BacFuse应用于腰椎退行性疾病的治疗并取得了良好的临床疗效,但目前其相关的生物力学特征暂无相关报道。目的:探索棘突间撑开融合装置BacFuse在腰椎退行性疾病中应用的生物力学特征。方法:构建山羊离体... 背景:近年来,棘突间撑开融合装置BacFuse应用于腰椎退行性疾病的治疗并取得了良好的临床疗效,但目前其相关的生物力学特征暂无相关报道。目的:探索棘突间撑开融合装置BacFuse在腰椎退行性疾病中应用的生物力学特征。方法:构建山羊离体脊柱模型(L_(1)-L6),模拟手术分为4组,分别为对照组、BacFuse固定组(L_(3/4))、钉棒固定组(L_(3/4))及Topping-off组(L_(3/4)钉棒固定+L_(2/3)BacFuse固定)。搭建山羊腰椎手术模型力学测试系统,采用生物力学机器进行力学加载,模拟腰椎在前屈、后伸、侧屈及旋转时的运动模式(4 Nm的力矩),采用视觉追踪系统进行定位捕捉,并完成力学及光学校准,通过计算得出L_(2/3)、L_(3/4)、L_(4/5)节段的活动度。结果与结论:①相对于对照组,BacFuse组L_(3/4)固定节段在前屈、后伸、侧屈与旋转方向上活动度分别减少27.27%,70%,38.1%及23.08%(P<0.05);钉棒固定组L_(3/4)固定节段在前屈、后伸、侧屈与旋转方向上活动度分别减少72.73%,80%,71.43%及73.08%(P<0.05)。②相对于对照组,BacFuse组邻近节段L_(2/3)在后伸、侧屈及旋转方向上分别增加33.33%,25%及23.81%(P<0.05),前屈活动未见明显变化;钉棒固定组的邻近节段L_(2/3)在前屈、后伸、侧屈与旋转方向上的活动度分别增加50%,44.44%,50%及58.96%(P<0.05);③相对于对照组,BacFuse组邻近节段L_(4/5)在后伸、旋转方向上分别增加27.3%,17.39%(P<0.05),前屈、侧屈活动未见明显变化;钉棒固定组的邻近节段L_(4/5)在前屈、后伸、旋转方向上的活动度分别增加38.89%,22.73%及26.09%(P<0.05),侧屈活动未见明显变化;④与钉棒固定组相比,Topping-off组L_(2/3)椎间活动度在前屈、后伸、侧屈、旋转分别减少37.04%,73.08%,56.67%及38.46%(P<0.05);与钉棒固定组相比,Topping-off组L_(4/5)节段椎间活动度在前屈方向上减少20%(P<0.05),后伸、侧屈及旋转未见明显区别;⑤提示BacFuse能够显著减少置入节段的活动度,提供一定的稳定性;相对于钉棒固定,仍然保留有较多的活动度,可减少对邻近节段的影响,同时可用于钉棒固定的Topping-off技术,显著减少了邻近节段的活动度,降低邻近节段退变的风险。 展开更多
关键词 腰椎退行性疾病 棘突间撑开融合装置 BacFuse 钉棒固定 生物力学 活动度
下载PDF
股骨颈骨折空心钉内固定后股骨近端骨质疏松的有限元分析 被引量:1
18
作者 薛晓峰 魏永康 +7 位作者 乔晓红 杜玉勇 牛建军 任立新 杨慧峰 张治民 郭媛 陈维毅 《中国组织工程研究》 CAS 北大核心 2024年第6期862-867,共6页
背景:股骨颈骨折空心钉内固定术后由于患肢短期内常常不能负重,且高刚度的内植物对骨折断端存在应力遮挡效应,易导致患肢出现骨质疏松,股骨近端生物力学分布发生变化,术后股骨头坏死发病率较高,目前关于股骨颈骨折术后股骨近端骨质疏松... 背景:股骨颈骨折空心钉内固定术后由于患肢短期内常常不能负重,且高刚度的内植物对骨折断端存在应力遮挡效应,易导致患肢出现骨质疏松,股骨近端生物力学分布发生变化,术后股骨头坏死发病率较高,目前关于股骨颈骨折术后股骨近端骨质疏松对股骨近端及空心钉生物力学影响的研究较少。目的:通过有限元分析探讨股骨颈骨折术后发生骨质疏松对空心钉内固定治疗的生物力学影响,探究生物力学因素在股骨头坏死进程中的作用。方法:获取1例股骨颈骨折患者股骨CT扫描数据,利用Mimics 19.0、3-Matic、UG 11.0、Hypermesh 14.0、Abaqus软件建立空心钉治疗股骨颈骨折的股骨近端模型,利用Abaqus软件分析1种术后股骨近端无骨质疏松、3种术后股骨近端骨质疏松的有限元模型,测量分析4种模型不同部件的应力、接触压力、位移峰值及云图,对比分析股骨头内部应力变化及分布情况。结果与结论:股骨头及下前空心钉的应力、接触压力随骨质疏松程度变化较大,4种模型的位移峰值随着骨质疏松程度加重而缓慢增长。通过单因素方差分析,结果显示骨质疏松程度对不同部件的应力、接触压力、位移峰值无显著性影响,股骨头内部应力分布随骨质疏松发生相应变化,股骨近端的生物力学环境变化对股骨头坏死有着重要影响。 展开更多
关键词 股骨 股骨颈骨折 空心钉 内固定术 骨质疏松 股骨头坏死 生物力学 有限元
下载PDF
带线锚钉+空心钉内固定治疗髌骨骨折的疗效 被引量:1
19
作者 王强 吕欣 +1 位作者 李兴业 刘晋元 《临床骨科杂志》 2024年第2期257-260,共4页
目的探讨带线锚钉+空心钉内固定治疗髌骨骨折的疗效。方法将60例髌骨骨折患者按照内固定方式不同分为观察组(采用带线锚钉+空心钉内固定治疗,30例)和对照组(采用克氏针张力带+钢丝捆扎内固定治疗,30例)。记录两组手术时间、骨折愈合情... 目的探讨带线锚钉+空心钉内固定治疗髌骨骨折的疗效。方法将60例髌骨骨折患者按照内固定方式不同分为观察组(采用带线锚钉+空心钉内固定治疗,30例)和对照组(采用克氏针张力带+钢丝捆扎内固定治疗,30例)。记录两组手术时间、骨折愈合情况、术后并发症发生率。采用Lysholm评分评价膝关节功能。结果患者均获得随访,观察组随访时间12~36(17.47±6.17)个月,对照组随访时间12~30(17.70±4.06)个月。手术时间观察组短于对照组(P<0.01)。两组骨痂形成时间2~3个月,骨折愈合时间4~6个月。术后并发症发生率观察组低于对照组(P<0.05)。末次随访时Lysholm评分评价的膝关节功能优良率两组比较差异无统计学意义(P>0.05)。结论带线锚钉+空心钉内固定治疗髌骨骨折能有效缩短手术时间、降低手术难度、减少术后并发症的发生,而且内固定稳定、牢靠,患者术后膝关节功能恢复良好。 展开更多
关键词 髌骨骨折 带线锚钉 空心钉 克氏针张力带 膝关节功能
下载PDF
股骨颈动力交叉螺钉系统与螺纹空心钉治疗垂直不稳定股骨颈骨折短期随访
20
作者 王强 吕欣 +1 位作者 李兴业 刘晋元 《中国骨伤》 CAS CSCD 2024年第5期458-463,共6页
目的:分析比较股骨颈动力交叉螺钉系统(femoral neck dynamic cross screw system,FNS)和螺纹空心钉(cannulated screws,CS)治疗垂直不稳定股骨颈骨折临床效果。方法:回顾分析2020年7月至2021年8月收治的40例垂直不稳定股骨颈骨折患者... 目的:分析比较股骨颈动力交叉螺钉系统(femoral neck dynamic cross screw system,FNS)和螺纹空心钉(cannulated screws,CS)治疗垂直不稳定股骨颈骨折临床效果。方法:回顾分析2020年7月至2021年8月收治的40例垂直不稳定股骨颈骨折患者的临床数据和短期随访结果,根据不同的内固定治疗方法分为股骨颈动力交叉螺钉系统FNS组20例和螺纹空心钉CS组20例。FNS组中,男11例,女9例,年龄58.5(50.3,62.5)岁;CS组中,男9例,女11例,年龄52.0(40.5,58.0)岁。观察比较两组手术时间、手术刀口长度、手术中失血量、治疗费用。术后利用X线影像资料评价术后骨折愈合状况和手术内固定状况,并测量患侧股骨颈短缩状况。比较两组术后患侧大腿激惹症发生情况、术后部分负重以及完全负重时间、术后股骨头早期坏死、再次手术翻修情况以及Harris评分。结果:FNS组获随访18.0(15.0,19.0)个月,CS组随访17.0(15.0,18.8)个月。两组手术时间、手术切口长度、手术中失血量比较,差异均无统计学意义(P>0.05)hFNS组的诊疗费用高于CS组(P<0.001)。FNS组术后无患侧大腿激惹征,而CS组6例存在大腿外侧不适或大腿外激惹征(P<0.05)。CS组术后平均部分负重活动时间和完全负重活动时间均长于FNS组(P<0.05)。末次随访时,CS组术后患侧股骨颈短缩长度大于FNS组(P<0.05)。两组均未发生术后股骨头早期坏死及再次手术翻修。两组术后12个月Harris评分比较,差异无统计学意义(P>0.05)。结论:FNS治疗垂直不稳定股骨颈骨折可明显降低大腿外侧激惹征的发生率,并有效降低垂直不稳定股骨颈骨折术后短缩率,可提供较稳定的防旋力与抗切割力,使患者可以相对较早下地,有利于患者术后患侧髋关节功能恢复,是对于垂直不稳定股骨颈骨折手术治疗的一种全新选择,但由于治疗费用偏高,临床中因结合实际情况,选用恰当的手术治疗方式。 展开更多
关键词 股骨颈骨折 股骨颈动力交叉钉系统 空心钉 内固定
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部