AIM: To investigate the prognostic significance of c-Kitgen emutation and DNA ploidy in gastointestinal stromal tumors (GISTs).METHODS: A total of 55 cases of GISTs were studied for the expression of c-Kit by immunohi...AIM: To investigate the prognostic significance of c-Kitgen emutation and DNA ploidy in gastointestinal stromal tumors (GISTs).METHODS: A total of 55 cases of GISTs were studied for the expression of c-Kit by immunohistochemistry, and the c-Kit gene mutations in exons 9, 11, 13, and 17 were detected by polymerase chain reaction-single strand confirmation polymarphism (PCR-SSCP) and denaturing high performance liquid chromatography (D-HPLC) techniques. DNA ploidy was determined by flow cytometry.RESULTS: Of the 55 cases of GISTs, 53 cases (96.4%) expressed c-Kit protein. The c-Kit gene mutations of exons 11 and 9 were found in 30 (54.5%) and 7 cases (12.7%),respectively. No mutations were found in exons 13 and 17.DNA aneuploidy was seen in 10 cases (18.2%). The c-Kit mutation positive GISTs were larger in size than the negative GISTs. The aneuploidy tumors were statistically associated with large size, high mitotic counts, high risk groups, high cellularity and severe nuclear atypia, and epithelioid type.There was a tendency that c-Kit mutations were more frequently found in aneuploidy GISTs.CONCLUSION: DNA aneuploidy and c-Kit mutations can be considered as prognostic factors in GISTs.展开更多
BACKGROUND Nucleic acid isolation from formalin-fixed, paraffin-embedded tissue(FFPET)samples is a daily routine in molecular pathology laboratories, but extraction from FFPET is not always easily achieved. Choosing t...BACKGROUND Nucleic acid isolation from formalin-fixed, paraffin-embedded tissue(FFPET)samples is a daily routine in molecular pathology laboratories, but extraction from FFPET is not always easily achieved. Choosing the right extraction technique is key for further examinations.AIM To compare the performance of four commercially available kits used for DNA extraction in routine practice.METHODS DNA isolation was performed on 46 randomly selected formalin-fixed, paraffinembedded(FFPE) colorectal adenocarcinoma(CRC) surgical specimens. Four commercially available extraction kits were used: two for manual DNA extraction(the Pure Link Genomic DNA Mini Kit from Invitrogen and the High Pure FFPE DNA Isolation Kit from Roche) and two for automated DNA extraction(the i Prep Genomic DNA Kit from Invitrogen and the Magna Pure LC DNA Isolation Kit from Roche). The DNA concentration and quality(odds ratio) among the four systems were compared. The results were correlated with the clinicopathological aspects of CRC cases: age, gender, localization, macro-and microscopic features,lymph node metastases, and the lymph node ratio.RESULTS The highest DNA concentration was obtained using the manual kits: 157.24 ±62.99 ng/μL for the Pure Link Genomic DNA Mini Kit and 86.64 ng/μL± 43.84 for the High Pure FFPE DNA Isolation Kit(P < 0.0001). Lower concentrations were obtained with automated systems: 20.39 ± 21.19 ng/μL for the Magna Pure LC DNA Isolation Kit and 8.722 ± 6.408 ng/μL for the i Prep Genomic DNA Kit,with differences between the systems used(P < 0.0001). The comparison between age, gender, tumor localization, pT or pN stage and the lymph node ratio indicated no statistically significant difference in DNA concentration using any of the nucleic acid isolation kits. DNA concentration was influenced by the macroscopic features and grade of differentiation. A higher DNA concentration was obtained for well-differentiated polypoid colorectal adenocarcinomas(CRCs), compared with undifferentiated ulcero-infiltrative carcinomas,irrespective of the kit used.CONCLUSION For research or diagnosis that needs high DNA concentrations, manual methods of DNA isolation should be used. A higher amount of DNA can be obtained from polypoid-type differentiated CRCs. Automated systems confer comfort and a lower amount of DNA that is, however, sufficient for classic polymerase chain reaction(PCR) and real-time quantitative PCR molecular examinations. All four commercially available kits can be successfully used in daily practice.展开更多
Approximately 80%-95%of gastrointestinal stromal tumors(GISTs)show positive staining for KIT,while the other 5%-20%show negative staining.If the tumor is negative for KIT,but is positive for CD34,a histological diagno...Approximately 80%-95%of gastrointestinal stromal tumors(GISTs)show positive staining for KIT,while the other 5%-20%show negative staining.If the tumor is negative for KIT,but is positive for CD34,a histological diagnosis is possible.However,if the tumor is negative for KIT,CD34,S-100,and SMA,a definitive diagnosis is often challenging.Recently,Discovered on GIST-1(DOG1)has received considerable attention as a useful molecule for the diagnosis of GIST.DOG1,a membrane channel protein,is known to be overexpressed in GIST.Because the sensitivity and specificity of DOG1 are higher than those of KIT,positive staining for DOG1has been reported,even in KIT-negative GISTs.KITnegative GISTs most commonly arise in the stomach and are mainly characterized by epithelioid features histologically.We describe our experience with a rare case of a KIT-negative GIST of the stomach that was diagnosed by positive immunohistochemical staining for DOG1 in a patient who presented with severe anemia.Our findings suggest that immunohistochemical staining for DOG1,in addition to gene analysis,is useful for the diagnosis of KIT-negative tumors that are suspected to be GISTs.展开更多
Mixed anhydride(MA)was used to conjugate ractopamine(RAC)to BSA and obtained artificial antigen BSA-RAC identified by UV and SDS-PAGE.Balb/c mice were immunized with BSA-RAC and hybridoma lines that secrete RAC monocl...Mixed anhydride(MA)was used to conjugate ractopamine(RAC)to BSA and obtained artificial antigen BSA-RAC identified by UV and SDS-PAGE.Balb/c mice were immunized with BSA-RAC and hybridoma lines that secrete RAC monoclonal antibody(mAb)were generated with cell fusion.A ciELISA kit for detection of RAC(RAC-Kit)was developed with RAC mAb and its performance were tested.The results indicated that BSA-RAC was successfully synthesized and its conjugation ratio of RAC to BSA was about 24.5∶1.Three hybridoma lines were filtered and the best one was 4D8-3E11,its affinity constant(Ka)was 1.65×1010 L/mol.The limit of detection of RAC-Kit was 0.5 ng/ml and its detection range was 0.5-184 ng/ml.The mean recoveries of RAC spiked in feed were 85.6% and in swine urine were 88.6%.The precision and accuracy of the assay as determined by inter-assay and intra-assay coefficient variation were below 15%.It had 9.4% cross-reactivity(CR%)to dobutamine and little or no CR to other compounds.The validity of RAC-Kit in 4 ℃ was in 180 d.展开更多
Objective The aim of this study was to investigate the relationship between peripheral plasma stem cell factor (SCF)/c-kit levels and the types of dipper and non-dipper hypertension in hypertensive patients.Methods Th...Objective The aim of this study was to investigate the relationship between peripheral plasma stem cell factor (SCF)/c-kit levels and the types of dipper and non-dipper hypertension in hypertensive patients.Methods This cross-sectional study included newly diagnosed hypertensive patients who underwent 24-hour ambulatory blood pressure monitor (ABPM) between January 2009 and 2012 in Jiangning city. Patients were divided into the dipper group and the non-dipper group according to ABPM measurements. The levels of SCF and its receptor c-kit, tumor necrosis factor-α (TNF-α) and interleukin 6 (IL-6) in peripheral blood were measured via enzyme-linked immunosorbent assays. The serum levels of glucose and lipid were examined as well. The levels of SCF/c-kit were compared between the dippers and the non-dippers; and their correlation with 24-hour mean systolic blood pressure (MSBP), 24-hour mean diastolic blood pressure (MDBP), TNF-αand IL-6 were investigated using linear regression analyses statistically.Results A total of 247 patients with newly diagnosed hypertension were recruited into the study, including 116 non-dippers and 131 dippers. The levels of peripheral plasma SCF were higher in non-dipper group (907.1±52.7 ng/L vs. 778.7±44.6 ng/L; t=2.837, P<0.01), and the levels of c-kit were higher in non-dipper group too (13.2±1.7 μg/L vs 9.57±1.4 μg/L; t=2.831, P<0.01). Linear regression analysis revealed that SCF/ckit levels were significantly positively correlated with MSBP, MDBP, plasma TNF-α, and IL-6 levels (all P<0.01).Conclusions Peripheral plasma SCF/c-kit levels are higher in patients with non-dipper hypertension than those with dipper one, and significantly correlate with 24-hour MSBP, 24-hour MDBP, serum TNF-α and IL-6 levels.展开更多
The SSM (sputum smear microscopy) and five immunochromatographic tuberculosis antibody detection tests (DiaSpot TB, Spodex TB, SD Rapid TB, Clinotech TB Screen and Precious One-step TB) were compared for diagnosis...The SSM (sputum smear microscopy) and five immunochromatographic tuberculosis antibody detection tests (DiaSpot TB, Spodex TB, SD Rapid TB, Clinotech TB Screen and Precious One-step TB) were compared for diagnosis of active TB at the Leprosy and Tuberculosis Referral Hospital, Uzuakoli, Abia State, Nigeria. Sputum specimens from 150 study participants (male/female ratio, 0.81) were cultured on Lowenstein-Jensen slopes and direct smears were stained by Ziehl-Neelsen technique and examined by light microscopy. Sera were tested for anti-TB antibodies using the rapid TB tests. A total of 91 participants were culture positive, 79 (86.8%) for M. tuberculosis and 12 (13.2%) for nontuberculous mycobacteria. The sensitivity of SSM was 50% (95% CI: 39.0-61.0) and specificity was 92.3% (95% CI: 86.4-98.2) in those culture positive for M. tuberculosis. The sensitivity and specificity of the Rapid TB tests ranged from 24.1-39.2% and 78.4-87.8%, respectively. None of the five rapid TB tests had acceptable level of accuracy for diagnosis of active TB. The sensitivity of SSM though moderate is inadequate for long term TB control in this setting.展开更多
文摘AIM: To investigate the prognostic significance of c-Kitgen emutation and DNA ploidy in gastointestinal stromal tumors (GISTs).METHODS: A total of 55 cases of GISTs were studied for the expression of c-Kit by immunohistochemistry, and the c-Kit gene mutations in exons 9, 11, 13, and 17 were detected by polymerase chain reaction-single strand confirmation polymarphism (PCR-SSCP) and denaturing high performance liquid chromatography (D-HPLC) techniques. DNA ploidy was determined by flow cytometry.RESULTS: Of the 55 cases of GISTs, 53 cases (96.4%) expressed c-Kit protein. The c-Kit gene mutations of exons 11 and 9 were found in 30 (54.5%) and 7 cases (12.7%),respectively. No mutations were found in exons 13 and 17.DNA aneuploidy was seen in 10 cases (18.2%). The c-Kit mutation positive GISTs were larger in size than the negative GISTs. The aneuploidy tumors were statistically associated with large size, high mitotic counts, high risk groups, high cellularity and severe nuclear atypia, and epithelioid type.There was a tendency that c-Kit mutations were more frequently found in aneuploidy GISTs.CONCLUSION: DNA aneuploidy and c-Kit mutations can be considered as prognostic factors in GISTs.
基金the University of Medicine,Pharmacy,Science and Technology Research Grant,No.275/11.01.2017
文摘BACKGROUND Nucleic acid isolation from formalin-fixed, paraffin-embedded tissue(FFPET)samples is a daily routine in molecular pathology laboratories, but extraction from FFPET is not always easily achieved. Choosing the right extraction technique is key for further examinations.AIM To compare the performance of four commercially available kits used for DNA extraction in routine practice.METHODS DNA isolation was performed on 46 randomly selected formalin-fixed, paraffinembedded(FFPE) colorectal adenocarcinoma(CRC) surgical specimens. Four commercially available extraction kits were used: two for manual DNA extraction(the Pure Link Genomic DNA Mini Kit from Invitrogen and the High Pure FFPE DNA Isolation Kit from Roche) and two for automated DNA extraction(the i Prep Genomic DNA Kit from Invitrogen and the Magna Pure LC DNA Isolation Kit from Roche). The DNA concentration and quality(odds ratio) among the four systems were compared. The results were correlated with the clinicopathological aspects of CRC cases: age, gender, localization, macro-and microscopic features,lymph node metastases, and the lymph node ratio.RESULTS The highest DNA concentration was obtained using the manual kits: 157.24 ±62.99 ng/μL for the Pure Link Genomic DNA Mini Kit and 86.64 ng/μL± 43.84 for the High Pure FFPE DNA Isolation Kit(P < 0.0001). Lower concentrations were obtained with automated systems: 20.39 ± 21.19 ng/μL for the Magna Pure LC DNA Isolation Kit and 8.722 ± 6.408 ng/μL for the i Prep Genomic DNA Kit,with differences between the systems used(P < 0.0001). The comparison between age, gender, tumor localization, pT or pN stage and the lymph node ratio indicated no statistically significant difference in DNA concentration using any of the nucleic acid isolation kits. DNA concentration was influenced by the macroscopic features and grade of differentiation. A higher DNA concentration was obtained for well-differentiated polypoid colorectal adenocarcinomas(CRCs), compared with undifferentiated ulcero-infiltrative carcinomas,irrespective of the kit used.CONCLUSION For research or diagnosis that needs high DNA concentrations, manual methods of DNA isolation should be used. A higher amount of DNA can be obtained from polypoid-type differentiated CRCs. Automated systems confer comfort and a lower amount of DNA that is, however, sufficient for classic polymerase chain reaction(PCR) and real-time quantitative PCR molecular examinations. All four commercially available kits can be successfully used in daily practice.
文摘Approximately 80%-95%of gastrointestinal stromal tumors(GISTs)show positive staining for KIT,while the other 5%-20%show negative staining.If the tumor is negative for KIT,but is positive for CD34,a histological diagnosis is possible.However,if the tumor is negative for KIT,CD34,S-100,and SMA,a definitive diagnosis is often challenging.Recently,Discovered on GIST-1(DOG1)has received considerable attention as a useful molecule for the diagnosis of GIST.DOG1,a membrane channel protein,is known to be overexpressed in GIST.Because the sensitivity and specificity of DOG1 are higher than those of KIT,positive staining for DOG1has been reported,even in KIT-negative GISTs.KITnegative GISTs most commonly arise in the stomach and are mainly characterized by epithelioid features histologically.We describe our experience with a rare case of a KIT-negative GIST of the stomach that was diagnosed by positive immunohistochemical staining for DOG1 in a patient who presented with severe anemia.Our findings suggest that immunohistochemical staining for DOG1,in addition to gene analysis,is useful for the diagnosis of KIT-negative tumors that are suspected to be GISTs.
基金Supported by the Key Project of National Science and Technology Surporting Plan during 11th-Five-Year of China(2006BAK02A21/1)~~
文摘Mixed anhydride(MA)was used to conjugate ractopamine(RAC)to BSA and obtained artificial antigen BSA-RAC identified by UV and SDS-PAGE.Balb/c mice were immunized with BSA-RAC and hybridoma lines that secrete RAC monoclonal antibody(mAb)were generated with cell fusion.A ciELISA kit for detection of RAC(RAC-Kit)was developed with RAC mAb and its performance were tested.The results indicated that BSA-RAC was successfully synthesized and its conjugation ratio of RAC to BSA was about 24.5∶1.Three hybridoma lines were filtered and the best one was 4D8-3E11,its affinity constant(Ka)was 1.65×1010 L/mol.The limit of detection of RAC-Kit was 0.5 ng/ml and its detection range was 0.5-184 ng/ml.The mean recoveries of RAC spiked in feed were 85.6% and in swine urine were 88.6%.The precision and accuracy of the assay as determined by inter-assay and intra-assay coefficient variation were below 15%.It had 9.4% cross-reactivity(CR%)to dobutamine and little or no CR to other compounds.The validity of RAC-Kit in 4 ℃ was in 180 d.
文摘Objective The aim of this study was to investigate the relationship between peripheral plasma stem cell factor (SCF)/c-kit levels and the types of dipper and non-dipper hypertension in hypertensive patients.Methods This cross-sectional study included newly diagnosed hypertensive patients who underwent 24-hour ambulatory blood pressure monitor (ABPM) between January 2009 and 2012 in Jiangning city. Patients were divided into the dipper group and the non-dipper group according to ABPM measurements. The levels of SCF and its receptor c-kit, tumor necrosis factor-α (TNF-α) and interleukin 6 (IL-6) in peripheral blood were measured via enzyme-linked immunosorbent assays. The serum levels of glucose and lipid were examined as well. The levels of SCF/c-kit were compared between the dippers and the non-dippers; and their correlation with 24-hour mean systolic blood pressure (MSBP), 24-hour mean diastolic blood pressure (MDBP), TNF-αand IL-6 were investigated using linear regression analyses statistically.Results A total of 247 patients with newly diagnosed hypertension were recruited into the study, including 116 non-dippers and 131 dippers. The levels of peripheral plasma SCF were higher in non-dipper group (907.1±52.7 ng/L vs. 778.7±44.6 ng/L; t=2.837, P<0.01), and the levels of c-kit were higher in non-dipper group too (13.2±1.7 μg/L vs 9.57±1.4 μg/L; t=2.831, P<0.01). Linear regression analysis revealed that SCF/ckit levels were significantly positively correlated with MSBP, MDBP, plasma TNF-α, and IL-6 levels (all P<0.01).Conclusions Peripheral plasma SCF/c-kit levels are higher in patients with non-dipper hypertension than those with dipper one, and significantly correlate with 24-hour MSBP, 24-hour MDBP, serum TNF-α and IL-6 levels.
文摘The SSM (sputum smear microscopy) and five immunochromatographic tuberculosis antibody detection tests (DiaSpot TB, Spodex TB, SD Rapid TB, Clinotech TB Screen and Precious One-step TB) were compared for diagnosis of active TB at the Leprosy and Tuberculosis Referral Hospital, Uzuakoli, Abia State, Nigeria. Sputum specimens from 150 study participants (male/female ratio, 0.81) were cultured on Lowenstein-Jensen slopes and direct smears were stained by Ziehl-Neelsen technique and examined by light microscopy. Sera were tested for anti-TB antibodies using the rapid TB tests. A total of 91 participants were culture positive, 79 (86.8%) for M. tuberculosis and 12 (13.2%) for nontuberculous mycobacteria. The sensitivity of SSM was 50% (95% CI: 39.0-61.0) and specificity was 92.3% (95% CI: 86.4-98.2) in those culture positive for M. tuberculosis. The sensitivity and specificity of the Rapid TB tests ranged from 24.1-39.2% and 78.4-87.8%, respectively. None of the five rapid TB tests had acceptable level of accuracy for diagnosis of active TB. The sensitivity of SSM though moderate is inadequate for long term TB control in this setting.