期刊文献+
共找到2,013篇文章
< 1 2 101 >
每页显示 20 50 100
Comparative study of functional optical zone:small incision lenticule extraction versus femtosecond laser assisted excimer laser keratomileusis 被引量:2
1
作者 Yao-Wen Song Meng-Fan Cui +3 位作者 Yi Feng Min Qu Yan Gao Rui He 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期238-244,共7页
AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential as... AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential associated factors for FOZ.METHODS:A total of 133 patients who received corneal refractive surgery in our hospital between November 2018 and July 2021 were retrospectively enrolled.There were 63 patients(123 eyes)in SMILE group and 70patients(139 eyes)in FS-LASIK group.The size of FOZ was measured using Pentacam 3-dementional anterior segment analyzer before and 3mo after surgery,so as to analyze postoperative achieved functional optical zone(AFOZ)and its contributing parameters.RESULTS:When planned functional optical zone(PFOZ)was 6.5 mm for both groups,AFOZ was 1.45±0.27 and 1.67±0.25 mm smaller than preoperative FOZ in SMILE group and FS-LASIK group 3mo after surgery.AFOZ in SMILE group was significantly larger than that in FS-LASIK group(P<0.001).Variation of FOZ was negatively correlated with preoperative spherical equivalent(SE)and positively correlated with variation of mean keratometry value(△Km),variation of spherical aberration(△SA),and variation of Q-value(△Q,all P<0.001)in both groups.Multiple variable linear regression equations were△FOZ=1.354-0.1×pre-SE+0.336×△Q+1.462×△SA in SMILE group and△FOZ=1.512+0.137×△Q+0.468×△SA in FS-LASIK group.CONCLUSION:AFOZ is significantly smaller than preoperative FOZ in both SMILE and FS-LASIK groups.With the same PFOZ,larger AFOZ is achieved in SMILE group than in FS-LASIK group. 展开更多
关键词 functional optical zone small incision lenticule extraction femtosecondlaser assisted excimer laser keratomileusis spherical equivalent spherical aberration
下载PDF
EXCIMER LASER ABLATING OF LIQUID CRYSTAL POLYMER
2
作者 梅胜敏 左敦稳 余大民 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1998年第2期72-77,共6页
Ablation experiments of A950 Liquid Crystal Polymer (LCP), as a kind of typical matrix of fibre reinforced polymer composites, are carried out in this paper. Data on the ablation of A950 LCP by excimer laser at 24... Ablation experiments of A950 Liquid Crystal Polymer (LCP), as a kind of typical matrix of fibre reinforced polymer composites, are carried out in this paper. Data on the ablation of A950 LCP by excimer laser at 248 nm are presented. The experimental results show that the ablation depth is a linear function of the number of pulse at constant laser fluence, The ablation rate varies with the logorithm of the fluence in a linear manner at different fluences. A satisfactory linear relationship is found between ablation energy and incident fluence. Perhaps due to the plume absorption and thermal effect, the ablation rate varies complicatedly with pulse repetition frequency. 展开更多
关键词 laser processing ablation POLYMER excimer laser
下载PDF
Smaller Ge Quantum Dots Obtained by ArF Excimer Laser Annealing
3
作者 曾玉刚 韩根全 余金中 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第4期641-644,共4页
Ge self-assembled quantum dots (SAQDs) are grown with a self-assembled UHV/CVD epitaxy system. Then, the as-grown Ge quantum dots are annealed by ArF excimer laser. In the ultra-shot laser pulse duration, -20ns, bul... Ge self-assembled quantum dots (SAQDs) are grown with a self-assembled UHV/CVD epitaxy system. Then, the as-grown Ge quantum dots are annealed by ArF excimer laser. In the ultra-shot laser pulse duration, -20ns, bulk diffusion is forbidden,and only surface diffusion occurs, resulting in a laser induced quantum dot (LIQD). The diameter of the LIQD is 20-25nm which is much smaller than the as-grown dot and the LIQD has a higher density of about 6 ×10^10cm^-2. The surface morphology evolution is investigated by AFM. 展开更多
关键词 Ge quantum dot ArF excimer laser annealing LIQD AFM
下载PDF
Fluorescence spectrum characteristic of ethanol-water excimer and mechanism of resonance energy transfer 被引量:2
4
作者 刘莹 宋春元 +2 位作者 骆晓森 陆建 倪晓武 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第5期1300-1306,共7页
The steady-state fluorescence spectrum characteristic of ethanol-water excimer has been studied in this paper. By analysing the features of the sharp emission spectrum with fine structures in a shortwave band and the ... The steady-state fluorescence spectrum characteristic of ethanol-water excimer has been studied in this paper. By analysing the features of the sharp emission spectrum with fine structures in a shortwave band and the characteristics of the broad and featureless fluorescence peaks in the longwave band, one can conclude that the excimers are formed between the new ethanol-water cluster molecules in the excited state and the ground state through the interaction among different chromophores. The excitation spectra in the two fluorescence bands have been studied, and their emission mechanisms have been ascertained based on the energy transfer theory. Furthermore, the critical distance of the resonance energy transfer has been calculated. 展开更多
关键词 fluorescence spectrum energy transfer ethanol-water cluster excimer
下载PDF
Successful opening in-stent chronic total occlusion lesion of coronary artery by excimer laser coronary angioplasty 被引量:2
5
作者 Jing BAI Hai-Xia WANG +7 位作者 Jiang-Tao WANG Jing ZHAO Liang PENG Xue-Dong YANG Zhe TANG Shaheena Nazneen Gao-Kun WANG Yu WANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2019年第6期502-506,共5页
In percutaneous coronary intervention (PCI), chronic total occlusion (CTO) coronary artery disease still remains difficult to treat. One of the reasons for the failure is the hard of the CTO lesions that balloon is di... In percutaneous coronary intervention (PCI), chronic total occlusion (CTO) coronary artery disease still remains difficult to treat. One of the reasons for the failure is the hard of the CTO lesions that balloon is difficult to pass through or expand. Previous methods to deal with CTO lesions that cannot be passed by balloon, include selecting reinforced catheter (such as 5 in 6 guiding catheter, Guidzilla catheter, or Tornus microcatheter), guidewire extrusion or rotary grinding technology. In recent years, excimer laser coronary angioplasty (ELCA) has been gradually applied to CTO lesions. Using inert halide as the laser medium, ELCA emits a 308 nm high-intensity unidirectional light wave with absorption depth of only 50 μmL, resulting in less thermal effect and less damage to non-target lesions. In this paper, we will describe a successful PCI case of an in-stent CTO lesion using ELCA with long term coronary angiography follow-up. 展开更多
关键词 Chronic total occlusion Drug coating BALLOON excimer laser CORONARY ANGIOPLASTY PERCUTANEOUS CORONARY intervention
下载PDF
Nickel-disilicide-assisted excimer laser crystallization of amorphous silicon 被引量:1
6
作者 廖燕平 邵喜斌 +5 位作者 郜峰利 骆文生 吴渊 付国柱 荆海 马凯 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第6期1310-1314,共5页
Polycrystalline silicon (poly-Si) thin film has been prepared by means of nickel-disilicide (NiSi2) assisted excimer laser crystallization (ELC). The process to prepare a sample includes two steps. One step cons... Polycrystalline silicon (poly-Si) thin film has been prepared by means of nickel-disilicide (NiSi2) assisted excimer laser crystallization (ELC). The process to prepare a sample includes two steps. One step consists of the formation of NiSi2 precipitates by heat-treating the dehydrogenated amorphous silicon (a-Si) coated with a thin layer of Ni. And the other step consists of the formation of poly-Si grains by means of ELC. According to the test results of scanning electron microscopy (SEM), another grain growth model named two-interface grain growth has been proposed to contrast with the conventional Ni-metal-induced lateral crystallization (Ni-MILC) model and the ELC model. That is, an additional grain growth interface other than that in conventional ELC is formed, which consists of NiSi2 precipitates and a-Si. The processes for grain growth according to various excimer laser energy densities delivered to the a-Si film have been discussed. It is discovered that grains with needle shape and most of a uniform orientation are formed which grow up with NiSi2 precipitates as seeds. The reason for the formation of such grains which are different from that of Ni-MILC without migration of Ni atoms is not clear. Our model and analysis point out a method to prepare grains with needle shape and mostly of a uniform orientation. If such grains are utilized to make thin-film transistor, its characteristics may be improved. 展开更多
关键词 polycrystalline silicon excimer laser crystallization Ni-disilicide Ni-metal-induced lateral crystallization two-interface grain growth
下载PDF
Percutaneous recanalization of total saphenous vein graft occlusion with excimer laser treatment 被引量:2
7
作者 Yuan HAN Quan-Min JING +2 位作者 Qian-Cheng WANG Yan-Bin SU Guo-Jun CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第4期234-240,共7页
Patients presenting with recurrence of anginal symptoms after saphenous vein bypass surgery pose an increasingly frequent challenge.In general,approximately 40%to 50%of saphenous vein graft(SVG)will become diseased or... Patients presenting with recurrence of anginal symptoms after saphenous vein bypass surgery pose an increasingly frequent challenge.In general,approximately 40%to 50%of saphenous vein graft(SVG)will become diseased or occluded within the first ten years after surgery.[1]Because adverse clinical outcomes,such as high restenosis rates and distal embolization,have been reported,percutaneous coronary intervention(PCI)for SVG is not recommended as a first-line strategy.[2]Distal embolization occurs in 2%–17%of patients despite advances in therapy,including the utilization of embolic protection device(EPD),which may lead to increased mortality at both short follow-up and midterm follow-up.[3]However,these patients often associated with inappropriate anatomic characteristics of native vessel intervention including calcification,tortuosity,abundant plaque burden,and complex chronic total occlusion(CTO)lesions.Moreover,repeat coronary bypass surgery is an option but is technically more demanding and is associated with a higher mortality.Therefore,it can sometimes result in SVG stenosis being the only intervention option.This is why the recanalization of SVG lesions,especially totally occluded lesions,remains one of the most challenging procedures in interventional cardiology. 展开更多
关键词 excimer laser PERCUTANEOUS CORONARY intervention Saphenous VEIN GRAFT
下载PDF
CLINICAL ANALYSIS OF EXCIMER LASER PHOTOREFRACTIVE KERATECTOMY FOR TREATMENT OF MYOPIA AND MYOPIC ASTIGMATISM 被引量:1
8
作者 张华 郭绒霞 +5 位作者 孙乃学 王峰 张道过 王彤 孙健 杨振国 《Journal of Pharmaceutical Analysis》 CAS 1999年第1期54-61,共8页
To evaluate the efficacy and accuracy of photorefractive keratectomy (PRK) for myopia and myopic astigmatism .SVS APEX excimer laser with a wave length of 193 nm(Sumit Technology Inc. Waltham, Mass, USA) was applied. ... To evaluate the efficacy and accuracy of photorefractive keratectomy (PRK) for myopia and myopic astigmatism .SVS APEX excimer laser with a wave length of 193 nm(Sumit Technology Inc. Waltham, Mass, USA) was applied. 316 myopic eyes of 168 patients were treated with PRK between September, 1996 and October, 1997, and 260 eyes (84%) of 150 patients were followed for more than three months, including male 68(116 eyes, 401%) and female 82(144 eyes, 599%). The preoperative spherical equivalent refractive errors ranged from -125D to -1000 (mean -467163D), and astigmatism ranged from 0 to -200D (means -033045D). We divided the patients into two groups according to the referaction: group A (from -125D to -590D) and group B(from -600 to -1000D). The number of eyes in the two groups were 220 and 40 respectively. In group A, on the 10th day, 689% has the uncorrected visual acuity (UCVA) equal to or one line better or lower than the preoperative best corrected visual acuity (BCVA). In 1,3,6 and 12 months, 90 %, 96%, 95% and 94% had the UCVA equal to or one line better or lower than the preoperative BCVA respectively. In group B, on the 10 th day, in 1,3,6 and 12 months, UCVA equal to or one line better or lower than the preoperative BCVA occurred in 359%, 83%, 87%, 86%, and 84% of the cases respectively. Most of the haze showed 051 grades except 3 eyes with the haze of 2 grade in 3 or 6 months and it changed to 1 and 05 grade respectively within one year. In 10 days and 1,3,6,12 months postoperatively, the corneal haze was noted in 329%, 848%, 628%,90% and 28% of the treated eyes respectively. We found that 193 nm excimer laser PRK was a predictable, safe, stable, and effective refractive surgery for correcting myopia up to -1000D in Chinese patients, and the effect was better in myopia lower than -600D. 展开更多
关键词 excimer laser photorefractive keratectomy MYOPIA myopic astigmatism
下载PDF
Formation and Gas Barrier Characteristics of Polysilazane-Derived Silica Coatings Formed by Excimer Light Irradiation on PET Films with Vacuum Evaporated Silica Coatings 被引量:1
9
作者 Tomoji Ohishi Yoshimi Yamazaki 《Materials Sciences and Applications》 2017年第1期1-14,共14页
The effects of excimer light irradiation on polysilazane coatings formed on PET films with vacuum-evaporated SiO2 coatings and the effects of these coatings on gas barrier characteristics have been investigated. The t... The effects of excimer light irradiation on polysilazane coatings formed on PET films with vacuum-evaporated SiO2 coatings and the effects of these coatings on gas barrier characteristics have been investigated. The temperature during light irradiation has a large effect on the coating’s molecular structure and gas barrier characteristics. When irradiation was performed at 100℃, the polysilazane coating transformed into a silica coating, and a compact silica coating at a much lower temperature than with heat treatment alone was produced. Surface irregularities in the vapor-deposited silica coating were smoothed out by the formation of a polysilazane coating, which was transformed into a compact silica coating when irradiated with light, resulting in a significant improvement in the gas barrier characteristics. The water vapor permeability of the thin coating irradiated with excimer light at 100℃ showed only 0.04 g/m2&bull;day (40℃, 90% RH). According to the results of investigation of temperature variation of water-vapor permeability, it is inferred that the developed film has an excellent gas barrier value, namely, 4.90 × 10–4 g/m2&bull;day at 25℃. This gas barrier coated PET film is transparent and flexible, and can be used in the fabrication of flexible electronics. Also, the proposed fabrication method effectively provides a simple low-cost and low-temperature fabrication technique without the need for high vacuum facility. 展开更多
关键词 POLYSILAZANE Photo-Irradiation excimer Light Gas BARRIER CHARACTERISTICS PET Film Flexible Electronics
下载PDF
Multiple excimer laser phototherapeutic keratectomies for Avellino corneal dystrophy:a case report 被引量:1
10
作者 Chihiro Koiwa Satoru Nakatani +3 位作者 Takenori Inomata Masahiro Yamaguchi Satoshi Iwamoto Akira Murakami 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第5期841-844,共4页
Dear Editor,I am Chihiro Koiwa,from the Department of Ophthalmology,Juntendo University Hospital.I am writing this letter to present a case of multiple excimer laser phototherapeutic keratectomies(PTKs)for Avellino co... Dear Editor,I am Chihiro Koiwa,from the Department of Ophthalmology,Juntendo University Hospital.I am writing this letter to present a case of multiple excimer laser phototherapeutic keratectomies(PTKs)for Avellino corneal dystrophy(ACD).Corneal dystrophy is a common type of hereditary,noninflammatory,and bilateral corneal disorder that involves various pathological,histological,and clinical manifestations[1].Advanced molecular gene sequencing has identified specific mutations that are associated with most dystrophies of this type.ACD,also known as granular corneal dystrophy typeⅡ[2],is autosomal dominant and associated with the R124H mutation of the transforming growth factor beta-induced(TGFBI)gene and characterized by deposits consistent with both discrete granular and lattice corneal opacities[3-4].An analysis of the TGFBI gene is essential to differentiate ACD because heterozygous R124H mutation carriers have minimal corneal abnormalities,whereas homozygotes have severe visual impairment,starting from early childhood,and early postoperative recurrence of corneal opacity. 展开更多
关键词 LASER excimer STARTING
下载PDF
Understanding the effects of excimer laser treatment on corrosion behavior of biodegradable Mg-1Ca alloy in simulated body fluid 被引量:1
11
作者 Yuxiang Liu Michele Curioni +1 位作者 Shiyun Dong Zhu Liu 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第4期1004-1023,共20页
In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SB... In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SBF)solution using immersion tests and electrochemical impedance spectroscopy(EIS).A 5μm melted layer with a homogeneous microstructure and an MgO film on the surface were achieved by laser radiation.Corrosion observations(hydrogen evolution,morphology and corrosion products)and EIS results revealed an improvement of corrosion resistance after laser treatment for 48 h.It was found a two-layer structure developed after 2 h immersion on both the untreated and laser-treated alloys,but the sequence of forming the two layers was opposite and greatly influenced by the laser-treated layer.The time-evolution corrosion processes on the untreated and laser-treated alloys were discussed,providing a better understanding of corrosion behavior of biodegradable Mg alloys modified by excimer laser. 展开更多
关键词 MAGNESIUM Biodegradable implant excimer laser Simulated body fluid Corrosion EIS
下载PDF
Simple Detection Method of Biogenic Amines in Decomposed Fish by Intramolecular Excimer Fluorescence 被引量:1
12
作者 Hirofumi Nishikawa Tatsuya Tabata Seiichi Kitani 《Food and Nutrition Sciences》 2012年第7期1020-1026,共7页
Biogenic amines are known to have various biological functions such as not only neurotransmitter and cell proliferation but also food poisoning. Bacterially-decomposed amines such as histamine, agmatine, putrescine, c... Biogenic amines are known to have various biological functions such as not only neurotransmitter and cell proliferation but also food poisoning. Bacterially-decomposed amines such as histamine, agmatine, putrescine, cadaverine, spermidine and spermine cause allergic symptoms. We developed simple method for measurement of polyamine as indicator of food decomposition with a fluorometer by using 4-(1-Pyrene)butyric acid N-hydroxysuccinimide ester (PSE). PSE reacts with primary and secondary amino moieties of polyamines and produces the intramolecular excimer fluorescence. Excimer fluorescence with broad peak at around 470 nm was clearly detected in linear type biogenic amines such as putrescine, cadaverine, spermidine and spermine at 10 mM. However neither histamine nor trimethylamine altered the fluorescence. Decomposed sardine and mackerel by improper storage showed stronger intensity than fresh ones. Comparing with OPA-method, PSE method was useful for screening biogenic amines present in food, esp. fish since the analysis was simple after one-step purification procedure. An inexpensive system which can rapidly detect biogenic amines from food is necessary in a medium and small-sized food business. The technique using excimer has potential to realize the high through-put screening system for evaluation of food freshness and is expected to bring the public interests such as food security and safety of consumer. 展开更多
关键词 4-(1-Pyrene)Butyric acid N-HYDROXYSUCCINIMIDE Ester PSE excimer Fluorescence BIOGENIC Amine FISH Decomposition POLYAMINE Food Poisoning
下载PDF
Selective removal technology using chemical etching and excimer assistance in precision recycle of color filter 被引量:1
13
作者 Pai-shan PA 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第A01期210-214,共5页
Color filters are produced using semiconductor production techniques although problems with low yield remain to be addressed. This study presents a new means of selective removal using excimer irradiation, chemical et... Color filters are produced using semiconductor production techniques although problems with low yield remain to be addressed. This study presents a new means of selective removal using excimer irradiation, chemical etching, or electrochemical machining on the fifth generation TFT LCDs. The selective removal of microstructure layers from the color filter surface of an optoelectronic flat panel display, as well as complete removal of the ITO thin-films, RGB layer, or resin black matrix (BM) layer from the substrate is possible. Individual defective film layers can be removed, or all films down to the Cr layer or bare glass can be completely eliminated. Experimental results demonstrate that defective ITO thin-films, RGB layers, or the resin BM layer can now be recycled with a great precision. When the ITO or RGB layer proves difficult to remove, excimer light can be used to help with removal. During this recycling process, the use of 225 nm excimer irradiation before chemical etching, or electrochemical machining, makes removal of stubborn film residues easy, effectively improving the quality of recycled color filters and reducing fabrication cost. 展开更多
关键词 chemical etching excimer light selective removal technology display color filter
下载PDF
Excimer laser coronary atherectomy for a severe calcified coronary ostium lesion:A case report 被引量:2
14
作者 Fang-Jie Hou Xiao-Teng Ma +1 位作者 Yu-Jie Zhou Jun Guan 《World Journal of Clinical Cases》 SCIE 2021年第34期10666-10670,共5页
BACKGROUND Percutaneous coronary intervention can be challenging for ostial coronary artery lesions due to calcium burden and elastic fiber content.Excimer laser coronary atherectomy(ELCA)is a less common treatment fo... BACKGROUND Percutaneous coronary intervention can be challenging for ostial coronary artery lesions due to calcium burden and elastic fiber content.Excimer laser coronary atherectomy(ELCA)is a less common treatment for severe calcified coronary ostium lesions.CASE SUMMARY An 81-year-old male presented to the Cardiology Department of Qingdao Municipal Hospital with a 1-year history of chest pain.Coronary angiography showed severe calcific stenosis(approximately 90%)in the right coronary artery ostium.The right coronary artery ostium was unable to be advanced using a 2.5 mm×12.0 mm balloon(NC Sprinter,Medtronic,United States)or dilated using a 2.0 mm×12.0 mm balloon(Sprinter,Medtronic,United States).The patient underwent successful ELCA and balloon dilation of the calcified coronary ostium lesion.CONCLUSION ELCA appears to be a safe and effective treatment for the management of severe calcified coronary ostium lesions. 展开更多
关键词 excimer laser coronary atherectomy Coronary ostium lesion Coronary calcified lesion Intravascular ultrasound Case report
下载PDF
Histopathological Study of Trabeculum after Excimer Laser Trabeculectomy ab Interno 被引量:3
15
作者 Shengsong Huang,Minbin Yu,Guangqiang Feng,Ping Zhang,Changyu QiuZhongshan Ophthalmic Center, Sun Yat-sen University of Medical Sciences, Guangzhou 510060 , China 《Eye Science》 CAS 2001年第1期11-15,共5页
Purpose: To study the clinical manifestations and histopathologic changes of trabeculum after excimer laser trabeculectomy ab interno (ELT), and to investigate the mechanisms of ELT in reducing intraocular pressure. M... Purpose: To study the clinical manifestations and histopathologic changes of trabeculum after excimer laser trabeculectomy ab interno (ELT), and to investigate the mechanisms of ELT in reducing intraocular pressure. Methods : ELT was performed on ten rabbit eves and postoperative responses were documented. Comeoscleral tissue samples were harvested consecutively each week until the 5th postoperative week and these samples were examined under light and electrical microscopy. Results: Mild stimulation signs were present postoperatix'ely in nine of ten eyes, but no serious complications were experienced. Obvious inflammation was observed in one rabbit eye as a result of iris damage during the surgical manipulations. Local kactures on the trabecular meshwork and openings into Schlemm' s canal were detected in all tissue samples under light microscope. Mitochondria were found to be turgescent and dilated like vacuoles and endoplasmic reticula were found to be dilated under electrical microscope in the early postoperative period. Later, all trabecular cells returned normal and no fihroblast cells were ever detected. Conclusions: Permanent openings through trabecular meshwork into the inner wall of Schlemm's canal can be created with ELT. The outflow resistance of aqueous humor can be reduced with these openings and intraocular pressure can be controlled thereafter. Eye Science 2001; 17:11 ~ 15. 展开更多
关键词 组织病理学 准分子激光疗法 ELT 高眼压 青光眼
下载PDF
Excimer紫外灯辐照法钽氧化物膜XPS分析
16
作者 别利剑 尹静 +1 位作者 彭菲 李春艳 《临沂师专学报》 1998年第3期24-27,共4页
报道了利用新型紫外光源—Excimer紫外灯辐照制备钽氧化物薄膜的新方法,并对所制备的薄膜进行了X光光电子能谱(XPS)分析,分析结果表明:所制备的钽氧化物薄膜不含碳而且符合化学计量比。
关键词 溶胶-凝胶法 钽氧化物薄膜 excimer紫外灯
下载PDF
The Characteristics of Dielectric Barrier Discharge and its Influence on the Excimer XeCl Emission 被引量:1
17
作者 徐金洲 刘卫 +1 位作者 梁荣庆 任兆杏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第6期1027-1036,共10页
In this work, the influence of discharge modes on the excimer XeCl emission (308 nm) has been studied by adding helium gas into the xenon and chlorine mixture. It is found that the transition from filament discharge t... In this work, the influence of discharge modes on the excimer XeCl emission (308 nm) has been studied by adding helium gas into the xenon and chlorine mixture. It is found that the transition from filament discharge to glow /filament - combined discharge leads to the decrease in excimer emission. We are the first one to use a flowing water film as an outer transparent electrode, and achieve a higher UV intensity, compared with the case by using a metal mesh as the outer electrode. The influence of the gas temperature both in the reactor Tg and in a discharge channel Tc on the excimer emission has been analyzed preliminarily. Finally, it has been expected that the replacement of chlorine gas Cl2 by another chlorine gas may reduce the heat generated in the discharge processes and give rise to the excimer XeCl* radiation. 展开更多
关键词 In The Characteristics of Dielectric Barrier Discharge and its Influence on the excimer XeCl Emission mode Cl
下载PDF
Excimer and Micellization of a Merocyanine
18
作者 Tian Yongchi and Liang Yingqiu (Institute of Theoretical Chemistry, Jilin University, Changchun)Ge Gang and Wang Shangtian (Department of Chemistry, Liaoning University, Shenyang) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1989年第3期279-281,共3页
Excimers are molecular associates which exist only in excited electronic states so that they are detectable only in eemission spectra,especially in fluorescence spectra,This fluorescent phenomenon has also been observ... Excimers are molecular associates which exist only in excited electronic states so that they are detectable only in eemission spectra,especially in fluorescence spectra,This fluorescent phenomenon has also been observed for some stable aggregates in which molecules are arranged in a special form.Excimer fluorescence component should be affected by associate state in stable or metastable aggregates.It leads us to studying micellization by means of fluorescence spectroscopy. 展开更多
关键词 excimer Micelliation MEROCYANINE
下载PDF
ON SELF-ABSORPTION CORRECTION IN EXCIMER FLUORESCENCE MEASUREMENTS OF POLYMER SOLUTIONS
19
作者 Xi-gao Jin Zhong Jiang +2 位作者 Ming Ni Feng-lian Bai Ren-yuan Qian Institute of Chemistry, Chinese Academy of Sciences, Beijing 100080, China 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2000年第5期465-468,共4页
The effect of self absorption on the ratio of excimer to monochromophore emission intensities, I-e/I-m, has been explored by experimentally changing the solution layer thickness of the emission light path traversed in... The effect of self absorption on the ratio of excimer to monochromophore emission intensities, I-e/I-m, has been explored by experimentally changing the solution layer thickness of the emission light path traversed in the solution in the right-angle geometry. The result shows that data obtained by front-face geometry are better than those obtained by right-angle geometry even after correction to zero solution thickness. The correction formula based on geometric optics given by Tsai and Torkelson is not adequate. 展开更多
关键词 excimer fluorescence self absorption polystyrene solution
下载PDF
Comparison of clinical outcomes of deep anterior lamellar keratoplasty and excimer laser assisted anterior lamellar keratoplasty in keratoconus
20
作者 Kübra Serbest Ceylanoglu Bahri Aydin Mehmet Cuneyt Ozmen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第4期582-586,共5页
AIM: To compare and evaluate the clinical outcomes of deep anterior lamellar keratoplasty(DALK) and excimer laser assisted anterior lamellar keratoplasty(ELLK) in eyes with keratoconus.METHODS: In this study, 57 eyes ... AIM: To compare and evaluate the clinical outcomes of deep anterior lamellar keratoplasty(DALK) and excimer laser assisted anterior lamellar keratoplasty(ELLK) in eyes with keratoconus.METHODS: In this study, 57 eyes of 56 patients operated between 2013 to 2017 were included. Thirty-one eyes underwent big-bubble DALK and twenty-six eyes underwent ELLK. Preoperative and at control visits complete ophthalmic examination was performed. RESULTS: The mean patient age at the time of DALK surgery was 27 y and mean follow-up period was 21±5.4 mo. The mean patient age at the time of ELLK surgery was 27 y and mean follow-up period was 40±18 mo. Mean best spectacle corrected visual acuity(BSCVA) at postoperative period was significantly higher for DALK group(0.66±0.11) versus ELLK group(0.4±0.2)(P<0.05). Descemet's membrane microperforation was occurred in 7 patients in DALK group versus in 1 patient in ELLK group. In 4 eyes, interface irregularity was developed in ELLK group. None of the patients in follow-up had graft rejection in both groups.CONCLUSION: In ELLK group, complication rate is lower, the surgical technique is simpler, faster and safer and also ELLK requires less experience with respect to DALK. Further, DALK can be performed unless satisfactory visual acuity is achieved after ELLK. 展开更多
关键词 excimer laser ASSISTED LAMELLAR KERATOPLASTY deep ANTERIOR LAMELLAR KERATOPLASTY big-bubble technique
下载PDF
上一页 1 2 101 下一页 到第
使用帮助 返回顶部