期刊文献+
共找到15,638篇文章
< 1 2 250 >
每页显示 20 50 100
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
1
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
Design and fabrication of compound varifocal lens driven by polydimethylsiloxane film elastic deformation
2
作者 缪文浩 韩泽峰 +3 位作者 赵瑞 梁忠诚 寇松峰 徐荣青 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期342-346,共5页
A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave... A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave lens form a coaxial compound lens system. The plane-concave lens equipped with driving coils is installed directly above the PDMS lens surrounded by the annular magnet. When different currents are applied, the annular magnet moves up and down, driving the PDMS film to undergo elastic deformation, and then resulting in longitudinal movement of the PDMS lens. The position change of the PDMS lens changes the focal length of the compound lens system. To verify the feasibility and practicability of this design, a prototype of our compound lens system is fabricated in experiment. Our proposed compound lens shows that its zoom ability reaches 9.28 mm when the current ranges from -0.20 A to 0.21 A. 展开更多
关键词 compound varifocal lens PDMS film elastic deformation focal length electromagnetic force zoom ability
下载PDF
Impact of multifocal gas-permeable lens designs on short-term choroidal response, axial length, and retinal defocus profile
3
作者 Muteb Alanazi Patrick Caroline +1 位作者 Amane Alshamrani Maria Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期247-256,共10页
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc... AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments. 展开更多
关键词 CHOROID gas-permeable contact lens retinal defocus axial length MYOPIA
下载PDF
SIRT1 inhibits apoptosis of human lens epithelial cells through suppressing endoplasmic reticulum stress in vitro and in vivo
4
作者 Hui Cui Di Sun +3 位作者 Sheng Meng Tian-Ju Ma Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1205-1216,共12页
AIM:To explore the effect of silent information regulator factor 2-related enzyme 1(SIRT1)on modulating apoptosis of human lens epithelial cells(HLECs)and alleviating lens opacification of rats through suppressing end... AIM:To explore the effect of silent information regulator factor 2-related enzyme 1(SIRT1)on modulating apoptosis of human lens epithelial cells(HLECs)and alleviating lens opacification of rats through suppressing endoplasmic reticulum(ER)stress.METHODS:HLECs(SRA01/04)were treated with varying concentrations of tunicamycin(TM)for 24h,and the expression of SIRT1 and C/EBP homologous protein(CHOP)was assessed using real-time quantitative polymerase chain reaction(RT-PCR),Western blotting,and immunofluorescence.Cell morphology and proliferation was evaluated using an inverted microscope and cell counting kit-8(CCK-8)assay,respectively.In the SRA01/04 cell apoptosis model,which underwent siRNA transfection for SIRT1 knockdown and SRT1720 treatment for its activation,the expression levels of SIRT1,CHOP,glucose regulated protein 78(GRP78),and activating transcription factor 4(ATF4)were examined.The potential reversal of SIRT1 knockdown effects by 4-phenyl butyric acid(4-PBA;an ER stress inhibitor)was investigated.In vivo,age-related cataract(ARC)rat models were induced by sodium selenite injection,and the protective role of SIRT1,activated by SRT1720 intraperitoneal injections,was evaluated through morphology observation,hematoxylin and eosin(H&E)staining,Western blotting,and RT-PCR.RESULTS:SIRT1 expression was downregulated in TMinduced SRA01/04 cells.Besides,in SRA01/04 cells,both cell apoptosis and CHOP expression increased with the rising doses of TM.ER stress was stimulated by TM,as evidenced by the increased GRP78 and ATF4 in the SRA01/04 cell apoptosis model.Inhibition of SIRT1 by siRNA knockdown increased ER stress activation,whereas SRT1720 treatment had opposite results.4-PBA partly reverse the adverse effect of SIRT1 knockdown on apoptosis.In vivo,SRT1720 attenuated the lens opacification and weakened the ER stress activation in ARC rat models.CONCLUSION:SIRT1 plays a protective role against TM-induced apoptosis in HLECs and slows the progression of cataract in rats by inhibiting ER stress.These findings suggest a novel strategy for cataract treatment focused on targeting ER stress,highlighting the therapeutic potential of SIRT1 modulation in ARC development. 展开更多
关键词 silent information regulator factor 2-related enzyme 1 endoplasmic reticulum stress APOPTOSIS human lens epithelial cells CATARACT
下载PDF
Evaluating the Effects of Graviton Redshift upon Spiral Galaxy Rotation Curves, Surface Brightness Magnitudes and Gravitational Lensing
5
作者 Firmin J. Oliveira 《Journal of High Energy Physics, Gravitation and Cosmology》 CAS 2024年第3期967-985,共19页
The effects of the gravitational redshift of gravitons upon spiral galaxy rotation energy are compared to the standard mass to light analyses in obtaining rotation curves. The derivation of the total baryonic matter c... The effects of the gravitational redshift of gravitons upon spiral galaxy rotation energy are compared to the standard mass to light analyses in obtaining rotation curves. The derivation of the total baryonic matter compares well with the standard theory and the rotation velocity is matched to a high precision. The stellar mass distributions obtained from the fit with graviton energy loss are used to derive the surface brightness magnitudes for the galaxies, which agree well with the observed measurements. In a new field of investigation, the graviton theory is applied to the observations of gravitational lenses. The results of these applications of the theory suggest that it can augment the standard methods and may eliminate the need for dark matter. 展开更多
关键词 GRAVITONS Gravitational Redshift Surface Brightness Gravitational lens lens Mass
下载PDF
Optical Microsphere Nano-Imaging:Progress and Challenges
6
作者 Guangxing Wu Minghui Hong 《Engineering》 SCIE EI CAS CSCD 2024年第5期102-123,共22页
The optical diffraction effect imposes a radical obstacle preventing conventional optical microscopes from achieving an imaging resolution beyond the Abbe diffraction limit and thereby restricting their usage in a mul... The optical diffraction effect imposes a radical obstacle preventing conventional optical microscopes from achieving an imaging resolution beyond the Abbe diffraction limit and thereby restricting their usage in a multitude of nanoscale applications.Over the past decade,the optical microsphere nanoimaging technique has been demonstrated to be a cost-effective solution for overcoming the diffraction limit and has achieved an imaging resolution of up to about k6k8 in a real-time and label-free manner,making it highly competitive among numerous super-resolution imaging technologies.In this review,we summarize the underlying nano-imaging mechanisms of the microsphere nanoscope and key advancements aimed at imaging performance enhancement:first,to change the working environment or modify the peripheral hardware of a single microsphere nanoscope at the system level;second,to compose the microsphere compound lens;and third,to engineer the geometry or ingredients of microspheres.We also analyze challenges yet to be overcome in optical microsphere nano-imaging,followed by an outlook of this technique. 展开更多
关键词 MICROSPHERE Nano-imaging Virtual imaging Microsphere compound lens Engineered microsphere
下载PDF
Effectiveness and safety of early lens extraction during par plana vitrectomy for proliferative diabetes retinopathy with mild cataract:a randomized clinical trial
7
作者 Wei-Bo Feng Lei Zheng +17 位作者 Ying-Qi Li Yong-Hao Li Guo-Ming Zhang Xian Wang Bing-Qian Liu Ling Jin Yi-Nuo Huang Yang-Fan Yang Zi-Dong Chen Da-Hui Ma Qing-Shan Chen Chao-Jun Qin Bing-Min Feng Zhu-Min Yang Xing Huang Cheng-Jie Yang Sheng-Hui Liu Ming-Xing Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期528-536,共9页
●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:T... ●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:This multicenter randomized controlled trial was conducted in three Chinese hospitals on patients with PDR,aged>45y,with mild cataracts.The participants were randomly assigned to the combined(PPV combined with simultaneously cataract surgery,i.e.,phacovitrectomy)or subsequent(PPV with subsequent cataract surgery 6mo later)group and followed up for 12mo.The primary outcome was the change in best-corrected visual acuity(BCVA)from baseline to 6mo,and the secondary outcomes included complication rates and medical expenses.●RESULTS:In total,129 patients with PDR were recruited and equally randomized(66 and 63 in the combined and subsequent groups respectively).The change in BCVA in the combined group[mean,36.90 letters;95%confidence interval(CI),30.35–43.45]was significantly better(adjusted difference,16.43;95%CI,8.77–24.08;P<0.001)than in the subsequent group(mean,22.40 letters;95%CI,15.55–29.24)6mo after the PPV,with no significant difference between the two groups at 12mo.The overall surgical risk of two sequential surgeries was significantly higher than that of the combined surgery for neovascular glaucoma(17.65%vs 3.77%,P=0.005).No significant differences were found in the photocoagulation spots,surgical time,and economic expenses between two groups.In the subsequent group,the duration of work incapacity(22.54±9.11d)was significantly longer(P<0.001)than that of the combined group(12.44±6.48d).●CONCLUSION:PDR patients aged over 45y with mild cataract can also benefit from early lens extraction during PPV with gratifying effectiveness,safety and convenience,compared to sequential surgeries. 展开更多
关键词 lens extraction pars plana vitrectomy proliferative diabetic retinopathy CATARACT simultaneously operations
下载PDF
Clinical prediction of insufficient vaults after implantable collamer lens implantation
8
作者 Jun Zhu Dan Cheng +3 位作者 Xue-Ying Zhu Fen-Fen Li Ye Yang Yu-Feng Ye 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1300-1306,共7页
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ... AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery. 展开更多
关键词 insufficient vault implantable collamer lens ciliary body posterior chamber
下载PDF
Overexpression of TRPV1 activates autophagy in human lens epithelial cells under hyperosmotic stress through Ca^(2+)-dependent AMPK/mTOR pathway
9
作者 Liu-Hui Huang Jiao Lyu +6 位作者 Sheng Chen Ting-Yi Liang Yu-Qing Rao Ping Fei Jing Li Hai-Ying Jin Pei-Quan Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期420-434,共15页
●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,... ●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,300,400,500,or 600 mOsm for 6,12,18,24h in vitro.Polymerase chain reaction(PCR)was employed for the mRNA expression of autophagyrelated genes,while Western blotting detected the targeted protein expression.The transfection of stub-RFP-sens-GFPLC3 autophagy-related double fluorescence lentivirus was conducted to detect the level of autophagy flux.Scanning electron microscopy was used to detect the existence of autolysosome.Short interfering RNA of autophagy-related gene(ATG)7,transient receptor potential vanilloid(TRPV)1 overexpression plasmid,related agonists and inhibitors were employed to their influence on autophagy related pathway.Flow cytometry was employed to test the apoptosis and intracellular Ca^(2+)level.Mitochondrial membrane potential was measured by JC-1 staining.The cell counting kit-8 assay was used to calculate the cellular viability.The wound healing assay was used to evaluate the wound closure rate.GraphPad 6.0 software was utilized to evaluate the data.●RESULTS:The hyperosmotic stress activated autophagy in a pressure-and time-dependent manner in LECs.Beclin 1 protein expression and conversion of LC3B II to LC3B I increased,whereas sequestosome-1(SQSTM1)protein expression decreased.Transient Ca^(2+)influx was stimulated caused by hyperosmotic stress,levels of mammalian target of rapamycin(mTOR)phosphorylation decreased,and the level of AMP-activated protein kinase(AMPK)phosphorylation increased in the early stage.Based on this evidence,autophagy activation through the Ca^(2+)-dependent AMPK/mTOR pathway might represent an adaptation process in LECs under hyperosmotic stress.Hyperosmotic stress decreased cellular viability and accelerated apoptosis in LECs and cellular migration decreased.Inhibition of autophagy by ATG7 knockdown had similar results.TRPV1 overexpression increased autophagy and might be crucial in the occurrence of autophagy promoted by hyperosmotic stress.●CONCLUSION:A combination of hyperosmotic stress and autophagy inhibition may be a promising approach to decrease the number of LECs in the capsular bag and pave the way for improving prevention of posterior capsular opacification and capsular fibrosis. 展开更多
关键词 CATARACT posterior capsular opacification lens epithelial cell hyperosmotic stress AUTOPHAGY apoptosis transient receptor potential vanilloid 1
下载PDF
Intraocular lens selection in diabetic patients:How to increase the odds for success
10
作者 Arvind Kumar Morya Prateek Nishant +4 位作者 Prasanna Venkatesh Ramesh Sony Sinha Aarti Heda Sarika Salodia Ripunjay Prasad 《World Journal of Diabetes》 SCIE 2024年第6期1199-1211,共13页
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur... The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population. 展开更多
关键词 DIABETICS CATARACT Intraocular lens Diabetic retinopathy Diabetes mellitus
下载PDF
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
11
作者 Humberto Carreras-Díaz Josefina Reñones de Abajo +1 位作者 María del Rosario Carreras-Díaz Amalia Lorente-Velázquez 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1322-1330,共9页
AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed inc... AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change. 展开更多
关键词 V4c Toric collamer lens corneal astigmatism surgically induced astigmatism corneal coupling
下载PDF
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
12
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
下载PDF
IOL Master 700与Lenstar LS900对高度近视合并白内障患者术前生物测量及人工晶状体计算的比较
13
作者 陶露莎 高铃 +3 位作者 喻娟 冯英 陈爽 吴敏 《国际眼科杂志》 CAS 2024年第4期612-617,共6页
目的:比较IOL Master 700与Lenstar LS900对高度近视合并白内障患者术前眼生物测量的差异性、相关性、一致性及人工晶状体(IOL)度数计算的准确性。方法:回顾性研究。收集2021-03/2023-03于陆军特色医学中心眼科行白内障超声乳化联合IOL... 目的:比较IOL Master 700与Lenstar LS900对高度近视合并白内障患者术前眼生物测量的差异性、相关性、一致性及人工晶状体(IOL)度数计算的准确性。方法:回顾性研究。收集2021-03/2023-03于陆军特色医学中心眼科行白内障超声乳化联合IOL植入手术的高度近视合并白内障患者136例136眼,平均年龄57.38±8.08岁。根据眼轴长度(AL)将患者分为3组:A组(26 mm≤AL≤28 mm)41眼,B组(28 mm30 mm)52眼。术前分别使用两种仪器测量AL、平均角膜曲率(Km)、前房深度(ACD)、晶状体厚度(LT)和白到白距离(WTW)。所有患者均采用Barrett UniversalⅡ公式计算IOL度数,个性化选择适宜的预留屈光度,比较两种仪器的预测屈光误差(PE)和绝对屈光误差(AE)。结果:三组患者中Lenstar LS900测量的AL和ACD均大于IOL Master 700测量值(均P<0.05),且两种仪器测量AL的平均差值C组>B组>A组。两种仪器测量LT、Km与WTW值均无差异(均P>0.05)。两种仪器所得各组生物参数均具有正相关性(均r>0.9,P<0.05)且一致性较好(95%LoA范围较窄)。两种仪器计算的AE无差异(P>0.05),但IOL Master 700计算的PE小于Lenstar LS900(P<0.05),且前者远视偏移百分比更低。结论:在高度近视合并白内障患者中,Lenstar LS900测量AL值大于IOL Master 700,且该差异随着AL的增加而增大,两种仪器对IOL的计算均具有良好的预测性,但IOL Master 700术后屈光误差更小,远视偏移百分比更低。 展开更多
关键词 IOL Master 700 lenstar LS900 高度近视 白内障 生物测量 眼轴 人工晶状体 Barrett UniversalⅡ
下载PDF
Flapless one-knot suture:a novel surgical technique for transscleral fixation of C-loop intraocular lenses
14
作者 Qing-Qing Long Bao-Jiang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期736-742,共7页
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv... AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique. 展开更多
关键词 C-loop intraocular lens implantation lens dislocation transscleral fixation four-haptics intraocular lens
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:2
15
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
Axial length,vitreoretinal pathology,and anterior chamber depth can predict postoperative refractive outcomes in phacovitrectomy/silicone oil removal 被引量:2
16
作者 Xu Chen He Zhao +6 位作者 Jia-Yun Ren Lu Wang Jun-Li Wan Bo Liu Nan Wu Xi Liu Yong Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期554-562,共9页
AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.M... AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice. 展开更多
关键词 axial length vitreoretinal pathology anterior chamber depth intraocular lens pars plana vitrectomy silicone oil removal CATARACT combined surgery refractive error intraocular tamponade
下载PDF
Technique of using Cionni-modified capsular tension ring in the management of severely traumatic lens subluxation 被引量:1
17
作者 Hao Jiang Wei Zhang Yan-Hua Chu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1078-1083,共6页
AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule... AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule support and underwent cataract surgery were retrospectively analyzed.Corrected distance visual acuity(CDVA),extent of zonulysis,intraocular lens(IOL)position,intraoperative presentation,and complications were assessed.The primary outcomes included IOL centration stability and other postoperative complications.RESULTS:Twenty patients(20 eyes)were included in this study.The mean age in this study was 58.0±11.3y,and the average follow-up time was 17.3±12.8mo.Capsule bags were saved by Cionni-modified CTR.Nine eyes(45%)underwent simultaneously anterior vitrectomy due to the presence of vitreous in the anterior chamber.The preoperative mean CDVA was 0.83±0.24 log MAR,and the postoperative average CDVA was 0.23±0.30 log MAR(P<0.05).The horizontal and vertical IOL decentration after surgery was 0.27±0.12 mm and 0.41±0.19 mm,respectively;the vertical and horizontal IOL tilt after surgery was 5.5°±2.5°and 6.1°±2.2°,respectively.None of the eyes had obvious IOL decentration during the follow-up time.Eight eyes(40%)had posterior capsule opacification(PCO)that was severe enough to cause poor vision.Neodymium:YAG laser capsulotomy were performed on these eyes when the CTR was stabilized.CONCLUSION:With the help of Cionni-modified CTR,capsular bag preservation and better IOL concentration can be achieved without major complications in patients with severely traumatic subluxated cataracts. 展开更多
关键词 Cionni-modified capsular tension ring subluxated traumatic cataracts surgical technique intraocular lens decentration intraocular lens tilt
下载PDF
LENTIS Comfort Toric人工晶状体植入术后视觉质量分析
18
作者 王丽雯 林松 方石峰 《国际眼科杂志》 CAS 北大核心 2023年第8期1376-1379,共4页
目的:探讨白内障手术中植入LENTIS Comfort Toric人工晶状体后的视觉质量。方法:回顾性对照临床研究,收集数字化导航辅助下白内障超声乳化摘除联合人工晶状体植入术患者40例40眼,植入LENTIS Comfort Toric(MF15T)人工晶状体为A组(24眼)... 目的:探讨白内障手术中植入LENTIS Comfort Toric人工晶状体后的视觉质量。方法:回顾性对照临床研究,收集数字化导航辅助下白内障超声乳化摘除联合人工晶状体植入术患者40例40眼,植入LENTIS Comfort Toric(MF15T)人工晶状体为A组(24眼),植入单焦点Toric人工晶状体为B组(16眼);观察术后3mo不同距离视力、术后散光质心值、脱镜率、离焦曲线变化以及人工晶状体稳定性等。结果:两组患者术后均无严重并发症出现,两组术后3mo远视力无差异(P>0.05);A组中视力、近视力明显优于B组(P<0.01);A组术后脱镜率为99%,B组为45%(P<0.05);两组术后3mo散光质心值均较术前改善,但组间无差异(P>0.05);术后3mo A组离焦曲线于+0.50、-1.75D分别出现峰值,形成平台并平缓下降,B组于+0.25、-0.25D出现峰值后呈陡峭趋势下降。术后1d A组出现1眼(4%)人工晶状体轴位旋转大于10°;B组出现6眼(38%)人工晶状体轴位旋转大于10°,2眼(33%)顺时针旋转,4眼(67%)逆时针旋转;两组均无人工晶状体移位发生。结论:两种人工晶状体均可矫正散光,其中LENTIS Comfort Toric人工晶状体能为白内障合并散光人群提供个性化的选择,可同时解决散光和获得全程视力,术后光学干扰发生率低,稳定性更好,视觉质量及满意度高。 展开更多
关键词 lenTIS Comfort Toric人工晶状体 散光矫正 残余散光 视觉质量
下载PDF
Transient vacuolar changes of the crystalline lens in patients using a dispersive ophthalmic viscosurgical device
19
作者 Yue Zhou Wan Chen +4 位作者 Yu Zhang Zhuo-Ling Lin Jing Li Hui Chen Wei-Rong Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1794-1799,共6页
AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who dev... AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane(PPM)removal surgery were presented and followed up.This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc(hyaluronic acid 1.6%-chondroitin sulfate 4.0%)exposure.Then,to provide the pathological basis for our speculation,another four cataract patients were randomly exposed to different OVDs,and their anterior lens capsules were investigated with transmission electron microscopy(TEM).RESULTS:After months,the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration.For the cataract patients,similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ(sodium hyaluronate gel 1.0%).In addition,marked ultrastructural changes,including chromatin condensation,extensive cytoplasmic vacuoles,and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc,were observed by TEM.CONCLUSION:The lens vacuolar changes may be associated with a dispersive OVD exposure.Therefore,it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction.In addition,close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions. 展开更多
关键词 vacuolar change crystalline lens ophthalmic viscosurgical devices lens epithelial cells transmission electron microscopy
下载PDF
Characteristic Analysis of Off-Axis Meta-Lens
20
作者 Jingaowa Hu Yang Liu +4 位作者 Shangnan Zhao Lingjie Wang Haokun Ye Jianping Zhang Xin Zhang 《Optics and Photonics Journal》 2023年第6期87-96,共10页
Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process an... Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process and manufacture. Off-axis meta-lens are a special type of meta-lens with a certain degree of dispersion that can be used as a beam-splitting element, providing a unique and feasible way to realize micro-miniature instruments. We analyze the effects of different numerical apertures and off-axis angles on the spectral resolution, focusing efficiency and simulation results of off-axis meta-lens to provide ideas for subsequent research and application of off-axis meta-lens. A number of off-axis meta-lens with parameters NA = 0.408 α = 13°, NA = 0.18 α = 13°<sup></sup> and NA = 0.408 α = 20° were simulated through Lumerical software. The results show that the off-axis angle is related to the resolution;the larger the angle, the better the spectral resolution but the lower the focusing efficiency;when the numerical aperture is smaller, the smaller the coverage of the phase distribution, which will lead to a larger deviation between simulation and theory. The designer needs to balance the numerical aperture, off-axis angle and other parameters reasonably according to the requirements in order to achieve the desired effect. The findings of this study have important reference values for the theoretical analysis of off-axis meta-lens and the design of parameters in practical applications. . 展开更多
关键词 Meta-lens Off-Axis Meta-lens Simulation Analysis
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部