This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typ...This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.展开更多
To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,...To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ.展开更多
基金Sponsored by the National Project of Scientific and Technical Supporting Programs Funded by Ministry of Science & Technology of China (Grant No.2012BAJ06B04-02)
文摘This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.
基金The National Natural Science Foundation of China(No.50878078)
文摘To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ.