期刊文献+
共找到28篇文章
< 1 2 >
每页显示 20 50 100
Establishment and Error Analysis of Model of Interference Fringe Contrast for Laser Tracing Measurement Optical System
1
作者 Hongfang Chen Mengyang Sun +3 位作者 Yinglun Ma Liang Tang Yu Wang Huixu Song 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第4期37-49,共13页
A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performa... A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performance.A comprehensive model of the interference fringe contrast based on the laser tracing system s measurement principle was established in this study.Simulation results based on ZEMAX verified the model.According to the simulation results,the placement angle of the analyzer had a direct influence on the interference fringe contrast.When the angle of the polarized light to the analyzer’s transmission axis increased from 65°to 85°,each contrast of the four-way interference fringes decreased from 0.9996 to 0.3528,the interference fringe contrast is decreased by 65%.Under the split ratio of beam splitters in the interference part(BS 1)of 5∶5,when the splitting ratio of BS 2 changed from 2∶8 to 8∶2,the fringe contrast of the interference signals received by the photodetectors increased,but the injection light intensity onto the PSD reflected by BS 2 decreased.The significant influence of the tracing performance was verified by the experiments.When splitting ratio of BS 2 increased,the contrast of the interference fringes increased.Due to the weakening of the incident light intensity of the PSD caused by the change of BS 2 splitting ratio,the response time of the tracing system is increased by 23.7 ms.As a result,the tracing performance of the laser tracing measurement optical system was degraded.An important theoretical basis was provided to evaluate and improve the accuracy and reliability of laser tracing measurement systems. 展开更多
关键词 interference fringe contrast laser tracing measurement high precision measurement ZEMAX.
下载PDF
New Measurement Method for Spline Shaft Rolling Performance Evaluation using Laser Displacement Sensor 被引量:4
2
作者 Hong-Wei Li Zhi-Qiang Liang +3 位作者 Jia-Jie Pei Li Jiao Li-Jing Xie Xi-Bin Wang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第4期124-132,共9页
In order to control the quality of spline shaft in rolling process, an efficient measurement method for rolling performance evaluation is essential. Here, a newly developed on-machine non-contact measurement prototype... In order to control the quality of spline shaft in rolling process, an efficient measurement method for rolling performance evaluation is essential. Here, a newly developed on-machine non-contact measurement prototype based on laser displacement sensor and rotary encoder is proposed. The prototype is intended for the automated evaluation of the spline shaft rolling performance by measuring the dimensional change of tooth root, which is correlated with the surface residual stress and micro-hardness. Laser displacement sensor and rotary encoder are used to record the polar radius and polar angle of each point on measuring section. Data are displayed in a polar coordinate system and fitted in a gear. Through multipoint curvature method, the roots of spline shaft are recognized automatically. Then, the dimensional change can be calculated by fitting the radius of the tooth root circle before and after rolling. Systematic error covering offset error is also analyzed and calibrated. At last, measurement test results show that the system has advantages of simple structure, high measurement precision(radius error < 0.6 μm), high measurement efficiency(measuring time < 2 s) and automatic control ability, providing a new opportunity for the efficient evaluation of various spline shafts in high-precision mechanical processing. 展开更多
关键词 laser measurement Spline shaft Rolling performance Dimensional change
下载PDF
External-cavity birefringence feedback effects of microchip Nd:YAG laser and its application in angle measurement 被引量:2
3
作者 任成 谈宜东 张书练 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第8期3438-3443,共6页
External-cavity birefringence feedback effects of the microchip Nd:YAG laser are presented. When a birefringence element is placed in the external feedback cavity of the laser, two orthogonally polarized laser beams ... External-cavity birefringence feedback effects of the microchip Nd:YAG laser are presented. When a birefringence element is placed in the external feedback cavity of the laser, two orthogonally polarized laser beams with a phase difference are output. The phase difference is twice as large as the phase retardation in the external cavity along the two orthogonal directions. The variable extra-cavity birefringence, caused by rotation of the external-cavity birefringenee element, results in tunable phase difference between the two orthogonally polarized beams. This means that the roll angle information has been translated to phase difference of two output laser beams. A theoretical analysis based on the Fabry-Perot cavity equivalent model and refractive index ellipsoid is presented, which is in good agreement with the experimental results. This phenomenon has potential applications for roll angle measurement. 展开更多
关键词 microchip laser external-cavity birefringence feedback orthogonally polarized lasers angle measurement
下载PDF
Mirror Mapping of Laser Interferometer Measurement System on Ultra-precise Movement Stage 被引量:1
4
作者 周云飞 于宝成 《Journal of Southwest Jiaotong University(English Edition)》 2006年第4期355-362,共8页
The accuracy and repeatability of the laser interferometer measurement system (LIMS) are often limited by the mirror surface error that comes from the mirror surface shape and distortion. This paper describes a new ... The accuracy and repeatability of the laser interferometer measurement system (LIMS) are often limited by the mirror surface error that comes from the mirror surface shape and distortion. This paper describes a new method to calibrate mirror map on ultraprecise movement stage (UPMS) with nanopositioning and to make a real-time compensation for the mirror surface error by using mirror map data tables with the software algorithm. Based on the mirror map test model, the factors affecting mirror map are analyzed through geometric method on the UPMS with six digrees of freedom. Dam processing methods including spline interpolation and spline offsets are used to process the raw sampling data to build mirror map tables. The linear interpolation as compensation method to make a real-time correction on the stage mirror unflatness is adopted and the correction formulas are illuminated. In this way, the measurement accuracy of the system is obviously improved from 40 nm to 5 nm. 展开更多
关键词 laser interferometer measurement system (LIMS) Ultra-precise movement stage (UPMS) Mirror mapping Splineinterpolation Mirror map data tables
下载PDF
The Approach of Compensation of Air Refractive Index in Thermal Expansion Coefficients Measurement Based on Laser Feedback Interferometry 被引量:2
5
作者 郑发松 丁迎春 +2 位作者 谈宜东 林静 张书练 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第7期17-20,共4页
We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifte... We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifted by a pair of aeousto-optic modulators and then the heterodyne phase measurement technique is used. The sample measured is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams hit perpendicularly and coaxially on each surface of the sample. The reference beams hit on the reference mirror and the high-refiectivity mirror, respectively. By the heterodyne configuration and computing, the influences of the vibration, distortion of the sample supporter and the effect of variations in the refractive index are measured and largely minimized. For validation, the TECs of aluminum samples are determined in the temperature range of 29-748K, confirming not only the precision within 5 × 10-7 K-1 and the accuracy within 0.4% from 298K to 448K but also the high sensitivity non-contact measurement of the lower reflectivity surface induced by the sample oxidization from 448 K to 748 K. 展开更多
关键词 In TEC The Approach of Compensation of Air Refractive Index in Thermal Expansion Coefficients measurement Based on laser Feedback Interferometry
下载PDF
Quantitative and Spatially Resolved Measurement of Atomic Potassium in Combustion Using Diode Laser 被引量:1
6
作者 高强 翁武斌 +1 位作者 李博 李中山 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第2期21-24,共4页
A compact optical setup for quantitative and spatially resolved measurement of atomic alkali concentration in combustion is demonstrated. Tunable diode laser absorption spectroscopy and laser-induced fluorescence are ... A compact optical setup for quantitative and spatially resolved measurement of atomic alkali concentration in combustion is demonstrated. Tunable diode laser absorption spectroscopy and laser-induced fluorescence are combined using a single continuous wave diode laser to measure the line-integration concentration and the relative distribution simultaneously, thereby obtaining the absolute concentration distribution along the laser beam. The results indicate the good performance of this method for one-dimensional quantitative measurement. 展开更多
关键词 Quantitative and Spatially Resolved measurement of Atomic Potassium in Combustion Using Diode laser LIF TDLAS
下载PDF
X-ray-boosted photoionization for the measurement of an intense laser pulse
7
作者 葛愉成 何海萍 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第6期322-329,共8页
Investigations show that X-ray-boosted photoionization (XBP) has the following advantages for in-situ measurements of ultrahigh laser intensity 1 and field envelope F(t) (time t, pulse duration VL, carrier-envelo... Investigations show that X-ray-boosted photoionization (XBP) has the following advantages for in-situ measurements of ultrahigh laser intensity 1 and field envelope F(t) (time t, pulse duration VL, carrier-envelope-phase Ф): accuracy, dynamic range, and rapidness. The calculated XBP spectra resemble inversely proportional functions of the photoelectron momentum shift. The maximum momentum p and the observable value Q (defined as a double integration of a normalized photoelectron energy spectrum, PES) linearly depend on I^1/2 and τL, respectively. Ф and F(t) can be determined from the PES cut-off energy and peak positions. The measurable laser intensity can be up to and over 1018 W/cm2 by using high energy X-rays and highly charged inert gases. 展开更多
关键词 measurement of ultrahigh laser pulse X-ray-boosted photoionization photoelectron energy spectrum quantum interference
下载PDF
Growth of High-Quality Superconducting FeSe0.5Te0.5 Thin Films Suitable for Angle-Resolved Photoemission Spectroscopy Measurements via Pulsed Laser Deposition
8
作者 孔万东 刘治国 +6 位作者 吴尚飞 王刚 钱天 殷嘉鑫 夏芮岩 颜雷 丁洪 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第8期144-147,共4页
High-quality superconducting FeSe0.5 Te0.5 films are epitaxiMly grown on different substrates by using the pulsed laser deposition method. By measuring the transport properties and surface morphology of films grown on... High-quality superconducting FeSe0.5 Te0.5 films are epitaxiMly grown on different substrates by using the pulsed laser deposition method. By measuring the transport properties and surface morphology of films grown on single- crystal substrates of Al2O3 (0001), SrTiO3 (001), and MgO (001), as well as monitoring the real-time growth process on MgO substrates with reflection high energy electron diffraction, we find the appropriate parameters for epitaxial growth of high-quality FeSe0.5 Te0.5 thin films suitable for angle-resolved photoemission spectroscopy measurements. We further report the angle-resolved photoemission spectroscopy characterization of the super- conducting films. The clearly resolved Fermi surfaces and the band structure suggest a sample quality that is as good as that of high-quality single-crystals, demonstrating that the pulsed laser deposition method can serve as a promising technique for in situ preparation and manipulation of iron-based superconducting thin films, which may bring new prosperity to angle-resolved photoemission spectroscopy research on iron-based superconductors. 展开更多
关键词 Thin Films Suitable for Angle-Resolved Photoemission Spectroscopy measurements via Pulsed laser Deposition Te Growth of High-Quality Superconducting FeSe ARPES MgO
下载PDF
Temporally Modulated Phase Retrieval Method for Weak Temporal Phase Measurement of Laser Pulses
9
作者 姚玉东 乔治 +2 位作者 汪小超 范薇 林尊琪 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期29-33,共5页
We propose a simple iterative algorithm based on a temporally movable phase modulation process to retrieve the weak temporal phase of laser pulses. This unambiguous method can be used to achieve a high accuracy and to... We propose a simple iterative algorithm based on a temporally movable phase modulation process to retrieve the weak temporal phase of laser pulses. This unambiguous method can be used to achieve a high accuracy and to simultaneously measure the weak temporal phase and temporal profile of pulses, which are almost transform- limited. A detailed analysis shows that this iterative method has valuable potential applications in the charac- terization of pulses with weak temporal phase. 展开更多
关键词 Temporally Modulated Phase Retrieval Method for Weak Temporal Phase measurement of laser Pulses
下载PDF
Single-Shot Measurement of Transient Phase Shift Induced by Laser Wake
10
作者 董军 卢宗贵 +8 位作者 张波 彭志涛 孙志红 夏彦文 元浩宇 唐军 朱德燕 刘华 吕嘉坤 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期60-62,共3页
Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry wi... Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry with ~ 140 fs resolution over a temporal region of I ps in a single shot. In this measurement, the image of the wake is obtained with one-dimensional spatial resolution and temporal resolution limited only by the bandwidth and chirp of the pulse. The 'bubbles' feature of the wake structure, along with multiple wakes excited by the main lobe and the side lobe of a laser focal-spot, is captured simultaneously. 展开更多
关键词 Single-Shot measurement of Transient Phase Shift Induced by laser Wake
下载PDF
Improved calibration method for displacement transformation coefficient in optical and visual measurements
11
作者 Haopeng Li Zurong Qiu 《Nanotechnology and Precision Engineering》 CAS CSCD 2023年第1期12-25,共14页
Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement trans... Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated. 展开更多
关键词 Displacement transformation coefficient(DTC) laser and vision-based displacement measuring module(LVDMM) Displacement measurement Locally weighted scatterplot smoothing(LOWESS) Calibration method
下载PDF
Landslide data mosaicking based on an airborne laser point cloud and multi-beam sonar images 被引量:1
12
作者 JI Hao-wei LUO Xian-qi ZHOU Yong-jun 《Journal of Mountain Science》 SCIE CSCD 2020年第9期2068-2080,共13页
Landslides are one of the most disastrous geological hazards in southwestern China.Once a landslide becomes unstable,it threatens the lives and safety of local residents.However,empirical studies on landslides have pr... Landslides are one of the most disastrous geological hazards in southwestern China.Once a landslide becomes unstable,it threatens the lives and safety of local residents.However,empirical studies on landslides have predominantly focused on landslides that occur on land.To this end,we aim to investigate ashore and underwater landslide data synchronously.This study proposes an optimized mosaicking method for ashore and underwater landslide data.This method fuses an airborne laser point cloud with multi-beam depth sounder images.Owing to their relatively high efficiency and large coverage area,airborne laser measurement systems are suitable for emergency investigations of landslides.Based on the airborne laser point cloud,the traversal of the point with the lowest elevation value in the point set can be used to perform rapid extraction of the crude channel boundaries.Further meticulous extraction of the channel boundaries is then implemented using the probability mean value optimization method.In addition,synthesis of the integrated ashore and underwater landslide data angle is realized using the spatial guide line between the channel boundaries and the underwater multibeam sonar images.A landslide located on the right bank of the middle reaches of the Yalong River is selected as a case study to demonstrate that the proposed method has higher precision thantraditional methods.The experimental results show that the mosaicking method in this study can meet the basic needs of landslide modeling and provide a basis for qualitative and quantitative analysis and stability prediction of landslides. 展开更多
关键词 laser point cloud Airborne laser measurement Mosaicking method Multi-beam sonar images SHIPBORNE Channel boundaries
下载PDF
Research on dynamic measurement method of speckle in laser display
13
作者 LIU Hong LIU Yaning ZHANG Xiaoyu 《Optoelectronics Letters》 EI 2024年第6期360-366,共7页
Laser display technology is the most promising display technology in the market and is widely used in many fields. However, laser speckle has been troubling the application and expansion of this technology in some fie... Laser display technology is the most promising display technology in the market and is widely used in many fields. However, laser speckle has been troubling the application and expansion of this technology in some fields. In order to better evaluate the speckle, speckle measurement methods must be studied. In this study, a dynamic measurement method for laser speckles is proposed according to the optical superposition characteristics of speckle, which can reduce the influence of non-coherent factors on the speckle measurement results. The feasibility of the dynamic speckle measurement method is verified by designing an experimental scheme. 展开更多
关键词 Research on dynamic measurement method of speckle in laser display
原文传递
Present Status of the Nd:YAG Thomson Scattering System Development for Time Evolution Measurement of Plasma Profile on Heliotron J
14
作者 Takashi MINAMI Shohei ARAI +12 位作者 Naoki KENMOCHI Hiroaki YASHIRO Chihiro TAKAHASHI Shinji KOBAYASHI Tohru MIZUUCHI Shinsuke OHSHIMA Satoshi YAMAMOTO Hiroyuki OKADA Kazunobu NAGASAKI Yuji NAKAMURA Kiyoshi HANATANI Shigeru KONOSHIMA Fumimichi SANO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期240-243,共4页
A new high repetition rate Nd:YAG Thomson scattering system is developed for the Heliotron J helical device. A main purpose of installing the new system is the temporal evolution measurement of a plasma profile for i... A new high repetition rate Nd:YAG Thomson scattering system is developed for the Heliotron J helical device. A main purpose of installing the new system is the temporal evolution measurement of a plasma profile for improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with -10 mm resolution. Two high repetition Nd:YAG lasers (〉 550 m J@ 50 Hz) realize the measurement of the time evolution of the plasma profile with ~10 ms time intervals. Scattered light is collected by a large concave mirror (D----800 mm, f/2.25) with a solid angle of -100 mstr and transferred to interference filter polychromators by optical fiber bundles in a staircase form. The signal is amplified by newly designed fast preamplifiers with DC and AC output, which reduces the low frequency background noise. The signals are digitized with a multi-event QDC, fast gated integrators. The data acquisition is performed by a VME-based system operated by the CINOS. 展开更多
关键词 plasma diagnostic Nd:YAG laser Thomson scattering measurement plasma improved confinement
下载PDF
VIBRATION MEASUREMENT OF DOUBLE-ENDED TUNING FORKS RESONATOR
15
作者 LENG Changlin ZHANG Guoxiong +2 位作者 ZHONG Ying JIANG Chengzhi YU Fusheng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第1期128-130,共3页
To enhance the coherence and reliability of the double-ended tuning fork (DETF) resonator, a measurement system of resonator vibration is presented to check its dynamic characteristics. Laser Doppler techniques are ... To enhance the coherence and reliability of the double-ended tuning fork (DETF) resonator, a measurement system of resonator vibration is presented to check its dynamic characteristics. Laser Doppler techniques are utilized and the relation between DETF vibration velocity and output current of photodetector is obtained. Resonator vibration equation is also analyzed and its driving power only depends on the direct current bias voltage and the amplitude of alternative voltage. Furthermore, a special resonator driving control circuit based on measurement is designed. The amplitude and frequency of circuit is controlled by a computer so that highly stable and strong driving signal can be output. Experiments on driving and measuring double-ended tuning fork have been done, The frequency of driving signal is 8 kHz and the peak-to-peak value of driving voltage is 140 V. Experimental results indicate resonator can be drived stably by driving control circuit and dynamic characteristics of DETF may be measured in real time. 展开更多
关键词 Resonator Optical measurement Tuning fork MEMS laser doppler
下载PDF
Rectification of 3D Data Obtained from Moving Range Sensor by Using Extended Projective Multiple View Geometry 被引量:1
16
作者 Kazuki Kozuka Jun Sato 《International Journal of Automation and computing》 EI 2008年第3期268-275,共8页
To measure the 3D shape of large objects, scanning by a moving range sensor is one of the most efficient methods. However, if we use moving range sensors, the obtained data have some distortions due to the movement of... To measure the 3D shape of large objects, scanning by a moving range sensor is one of the most efficient methods. However, if we use moving range sensors, the obtained data have some distortions due to the movement of the sensor during the scanning process. In this paper, we propose a method for recovering correct 3D range data from a moving range sensor by using the multiple view geometry under projective projections in space-time. We assume that range sensor radiates laser beams in a raster scan order, and they are observed from two cameras. We first show that we can deal with range data as 2D images, and show that the extended multiple view geometry can be used for representing the relationship between the 2D image of range data and the 2D image of cameras. We next show that the extended multiple view geometry can be used for rectifying 3D data obtained by the moving range sensor. The method is implemented and tested in synthetic images and range data. The stability of the recovered 3D shape is also evaluated. 展开更多
关键词 Machine vision stereo vision shape measurement laser measurement applications image processing.
下载PDF
Multi-use laser impulse pendulum and laser propulsion parameters measurement 被引量:3
17
作者 李静 童慧峰 +2 位作者 蔡建 唐志平 李胜利 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第11期650-653,共4页
In order to investigate the mechanisms of both the air-breathing and the ablation modes of laser propulsion under laboratory conditions, a multi-use laser impulse pendulum (MULIP) is developed. The measurable impulse ... In order to investigate the mechanisms of both the air-breathing and the ablation modes of laser propulsion under laboratory conditions, a multi-use laser impulse pendulum (MULIP) is developed. The measurable impulse range is from 1.0×10-4 to 3.8×10-3 N·s. The experimental calibration data agree well with the theoretical calculated data. With MULIP, the ablation mode has been performed, in which a high power pulsed Nd:glass laser (λ= 1.06μm, τ=20 ns) and a gray PVC film sample are used. The experimental results show that the maximum momentum coupling coefficient Cm is 7.73×10-5 N/W, and the maximum specific impulse Isp is 208.6 s. 展开更多
关键词 MODE Multi-use laser impulse pendulum and laser propulsion parameters measurement HIGH
原文传递
Numerical Simulation and Experimental Research on Passive Hydrodynamic Bearing in a Blood Pump 被引量:1
18
作者 HAN Qing RUAN Xiaodong +1 位作者 CHEN Wenyu FU Xin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第5期967-973,共7页
The current research of hydrodynamic bearing in blood pump mainly focuses on the bearing structure design.Compared with the typical plane slider bearing and Rayleigh step bearing,spiral groove bearing has excellent pe... The current research of hydrodynamic bearing in blood pump mainly focuses on the bearing structure design.Compared with the typical plane slider bearing and Rayleigh step bearing,spiral groove bearing has excellent performance in load-carrying capacity.However,the load-carrying capacity would decrease significantly with increasing flow rate in conventional designs.In this paper,the special treatment is made to the upper spiral groove bearing to make sure that both the circulatory flowing and load-carrying capacity are high.Three-dimensional computational fluid dynamics(CFD) models in the space between rotor and shaft are developed by using FLUENT software.Effects of groove number,film height and groove depth on load-carrying capacity of the spiral groove bearings are investigated by orthogonal experiment design.The experimental results show that film height is the most remarkable factor to the load-carrying capacity.The variation tendency of load-carrying capacity reveals that the best combination of geometry is the one with groove number of 8,film height 0.03 mm and groove depth 0.08 mm.The velocity and pressure distributions in spiral groove bearings are also analyzed,and the analysis result shows that the distributions are in conformity with the design of the blood pump based on the principle of hydrodynamic bearing.The displacement of the rotor with the best combination parameters is tested by using laser displacement sensors,the testing result shows that the suspending performance is satisfactory both in axial and radial directions.This research proposes a bearing design method which has sufficient load-carrying capacity to support rotor as an effective passive hydrodynamic bearing. 展开更多
关键词 blood pump spiral groove bearing hydrodynamic bearing laser displacement measurement
下载PDF
The application of laser reflective tomography in near-field measurements of ultrasonic transducers 被引量:4
19
作者 WANG Yuebing WANG Shiquan 《Chinese Journal of Acoustics》 2014年第3期257-266,共10页
With Laser Reflective Tomography(LRT),the near fields of ultrasonic transducers were measured and analyzed.The principle of LRT measurement of ultrasonic field distribution was introduced and an experimental system ... With Laser Reflective Tomography(LRT),the near fields of ultrasonic transducers were measured and analyzed.The principle of LRT measurement of ultrasonic field distribution was introduced and an experimental system was set up.Acoustic pressure of a multiple element piston transducer was measured by using of a laser vibrometer.Its distribution in amplitude and phase was obtained.The acoustic pressure in the same region was measured with a needle hydrophone to validate the LRT method.Furthermore,through reconstruction of acoustic fields,it indicated that LRT method is suitable for predicting the distribution on transducers'surface and conditions of active elements. 展开更多
关键词 The application of laser reflective tomography in near-field measurements of ultrasonic transducers LRT
原文传递
Real-time human blood pressure measurement based on laser self-mixing interferometry with extreme learning machine 被引量:2
20
作者 王秀琳 吕莉萍 +1 位作者 胡路 黄文财 《Optoelectronics Letters》 EI 2020年第6期467-470,共4页
In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied ... In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method. 展开更多
关键词 PROFILE Real-time human blood pressure measurement based on laser self-mixing interferometry with extreme learning machine
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部