This paper considers the problem of noise cancellation for the magnetic flux leakage (MFL) data obtained from the inspection of oil pipelines. MFL data is contaminated by various sources of noise, and the noise can co...This paper considers the problem of noise cancellation for the magnetic flux leakage (MFL) data obtained from the inspection of oil pipelines. MFL data is contaminated by various sources of noise, and the noise can considerably reduce the detectability of flaw signals in MFL data. This paper presents a new de-noising approach for removing the system noise contained in the MFL data by using the coefficients de-noising with wavelet transform. Experimental results are presented to demonstrate the advantages of this de-noising approach over the conventional wavelet de-noising method.展开更多
A novel high-frequency and high power density planar insulated core transformer(PICT) applied to high voltage DC generator is introduced. PICT's operating principle and fundamental configuration are described,and ...A novel high-frequency and high power density planar insulated core transformer(PICT) applied to high voltage DC generator is introduced. PICT's operating principle and fundamental configuration are described,and preliminary experimental results in self-designed PICT apparatus are presented. Emphatically, magnetic leakage flux(MFL) giving rise to the output voltage drop is analyzed in detail both theoretically and by finite element method(FEM). Showing good consistency with experimental result, FEM simulation is considered to be practicable in physical design of PICT. To cancel out leakage inductance and improve the voltage uniformity,compensation capacitor is adopted and experimental verification is also presented. All shows satisfactory results.展开更多
文摘This paper considers the problem of noise cancellation for the magnetic flux leakage (MFL) data obtained from the inspection of oil pipelines. MFL data is contaminated by various sources of noise, and the noise can considerably reduce the detectability of flaw signals in MFL data. This paper presents a new de-noising approach for removing the system noise contained in the MFL data by using the coefficients de-noising with wavelet transform. Experimental results are presented to demonstrate the advantages of this de-noising approach over the conventional wavelet de-noising method.
基金Supported by the Science and Technology Commission of Shanghai Municipality under Grant No.12ZR1436500the Knowledge Innovation Programm of the Chinese Academy of Sciences
文摘A novel high-frequency and high power density planar insulated core transformer(PICT) applied to high voltage DC generator is introduced. PICT's operating principle and fundamental configuration are described,and preliminary experimental results in self-designed PICT apparatus are presented. Emphatically, magnetic leakage flux(MFL) giving rise to the output voltage drop is analyzed in detail both theoretically and by finite element method(FEM). Showing good consistency with experimental result, FEM simulation is considered to be practicable in physical design of PICT. To cancel out leakage inductance and improve the voltage uniformity,compensation capacitor is adopted and experimental verification is also presented. All shows satisfactory results.