Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca...Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.展开更多
AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This ...AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This retrospective consecutive case series included patients with subluxated lenses by more than 180 degrees who underwent lens extraction,transcapsular scleral fixation of the standard CTR through equatorial capsulotomy,in-the-bag IOL implantation and with at least 6mo follow-up.Preoperative and postoperative best corrected visual acuity(BCVA),intraocular pressure(IOP),complications,and postoperative IOL tilt and decentration were recorded.RESULTS:Nine eyes of 7 patients with a mean followup of 11.0±3.7mo were included in this study.The BCVA was significantly improved from 0.64±0.22 logMAR preoperatively to 0.21±0.19 logMAR postoperatively(P<0.001).The IOP was within the normal range postoperatively.The mean tilt of the IOL was 4.30°±2.31°(range,1.0°to 8.9°)and the mean decentration of the IOL was 0.37±0.12 mm(range,0.14 to 0.50 mm).No visually threatened intraoperative and postoperative complications were detected during the follow-up period.CONCLUSION:This is a safe and effective surgical technique for managing patients with severely subluxated lenses.It has achieved favorable outcomes with fewer surgical manipulations and less need for advanced capsular support devices.展开更多
AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification...AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients.展开更多
AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-...AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-70y)undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes)or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm)was significantly better in the trifocal group during all follow-up(P≤0.004)as well as 6-month uncorrected near(P=0.008)and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P〈0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision.展开更多
AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBASE and P...AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBASE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models. RESULTS: Four prospective randomized controlled trials (RCTs) and five cohorts provided data were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=.0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for uncorrected distance VA, and MD- -0.02; 95%CI, -0.03 to .0.00; Z=2.02, P=0.04 for corrected distance VA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=.0.01; 95%CI, -0.07 to 0.04; Z=0.42, P=-0.68 for distance-corrected near VA, and MD=-0.01; 95%CI, -0.06 to 0.03; Z=0.55, P=0.58 for corrected near VA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results. CONCLUSION: All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near VA.展开更多
AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implanta...AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove.展开更多
AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Elect...AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Electronic databases including PubMed,Embase, and the Cochrane Library were queried from their starting till January 2020. RCTs investigating the impact of hydrophobic versus hydrophilic acrylic intraocular lenses on PCO were considered eligible in this study. The pooled effect estimates were calculated using the random-effects model.RESULTS: Thirteen RCTs comprising of 939 patients(1263 eyes) were covered in this study. Patients with hydrophobic acrylic intraocular lenses had a lower PCO score than those with a hydrophilic acrylic intraocular lenses [standard mean difference:-1.80;95% confidence interval(CI):-2.62 to-0.98;P<0.001]. Moreover, the frequency of neodymium-doped yttrium aluminum garnet(Nd:YAG)capsulotomy in patients with hydrophobic acrylic intraocular lenses was significantly lower than patients with hydrophilic acrylic intraocular lenses(relative risk: 0.38;95%CI: 0.20-0.71;P=0.003).CONCLUSION: These findings suggest that hydrophobic acrylic intraocular lenses are superior to hydrophilic acrylic intraocular lenses in patients after cataract surgery due to lower PCO score and reduced Nd:YAG capsulotomy. While similar studies are conducted by other researchers, the present study conducted subgroup analyses that show superior results with hydrophobic lenses in trials conducted in western countries.展开更多
AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A t...AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group.展开更多
AIM : To evaluate the prediction error in intraocular lens(IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation...AIM : To evaluate the prediction error in intraocular lens(IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position(ELP).METHODS: Retrospective study including a total of 25 eyes of 13 patients(age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL(Oculentis Gmb H, Germany). In all cases, an adjusted IOL power(P IOLadj) was calculated based on Gaussian optics using a variable keratometric index value(n kadj) for the estimation of the corneal power(P kadj) and on a new value for ELP(ELP adj) obtained by multiple regression analysis.This P IOLadj was compared with the IOL power implanted(P IOLReal) and the value proposed by three conventional formulas(Haigis, Hoffer Q and Holladay Ⅰ).RESULTS: P IOLReal was not significantly different than P IOLadj and Holladay IOL power(P 】0.05). In the Bland and Altman analysis, P IOLadj showed lower mean difference(-0.07 D) and limits of agreement(of 1.47 and-1.61 D)when compared to P IOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELP adj was significantly lower than ELP calculated with other conventional formulas(P 【0.01) and was found to be dependent on axial length, anterior chamber depth and P kadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing thekeratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.展开更多
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien...Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.展开更多
·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative stu...·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.展开更多
AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent biman...AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.展开更多
AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational ca...AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including i Sert250 NC60(NC60), En Vista MX60(MX60), Acry Sof IQ SN60 WF(SN60 WF), TECNIS ZCB00(ZCB00), and TECNIS PCB00(PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via nonpreloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device(OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodiumstained OVD. RESULTS: The average time for IOL implantation was 22.0 s for NC60, 43.2 s for MX60, 32.3 s for SN60 WF, 41.4 s for ZCB00, and 14.6 s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60 WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION: IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems.展开更多
【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shun...【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the展开更多
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
A 22-year-old patient suffering from both-side extreme hyperopia with amblyopia was corrected with an Artisan iris-fixated intraocular lens (IOL) implantation followed to clear lens extraction (CLE) with posterior cha...A 22-year-old patient suffering from both-side extreme hyperopia with amblyopia was corrected with an Artisan iris-fixated intraocular lens (IOL) implantation followed to clear lens extraction (CLE) with posterior chamber (PC)-IOL implantation. The preoperative refraction values were +17.75DS -1.50DC × 168° for the right eye and +17.25DS -0.75DC × 8° for the left eye. The uncorrected visual acuity (UCVA) was 20/200 bilaterally and the spectacle-corrected visual acuity (BSCVA) was 20/50 bilaterally. One year after Artisan iris-fixated IOL implantation, bilateral BSCVA was 20/50 with a refraction of +1.25DS -0.75DC × 13° for the right eye and +1.50DS -1.00DC × 55° for the left eye. The outcomes of an Artisan iris-fixated IOL implantation followed to CLE with PC-IOL implantation were encouraging for the correction of extreme hyperopia. Long term follow-up examinations were necessary for further determination of the efficacy and safety of this combinational procedure.展开更多
Dear Sir,Iam Dr.Li-Na Meng,from the Qingdao Eye Hospital,Shandong Eye Institute,Shandong Academy of Medical Sciences,Qingdao,China.I want to present a rare case of secondary intraocular lens(IOL)implantation in an11-y...Dear Sir,Iam Dr.Li-Na Meng,from the Qingdao Eye Hospital,Shandong Eye Institute,Shandong Academy of Medical Sciences,Qingdao,China.I want to present a rare case of secondary intraocular lens(IOL)implantation in an11-year-old boy who developed the complication of ciliary body detachment.When he was 2 years old,the boy underwent bilateral cataract extraction for congenital cataract in the other展开更多
Objective:To observe the changes of diagnosis and treatment of a patient with rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation in high myopia,and analyze its mechanism and treatment com...Objective:To observe the changes of diagnosis and treatment of a patient with rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation in high myopia,and analyze its mechanism and treatment combined with the literature.Methods:To report a case of rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation.Result:Two months after the patient underwent scleral cerclage+pad pressing+vitrectomy+silicone oil filling,the fundus color photos showed that the vitreous cavity was filled with silicone oil,the fundus retina was flat,the cerclage ridge was obvious,and a large number of old laser spots.After the silicone oil in the eye was removed,the eye examination:the naked visual acuity of the left eye was 0.12,the corrected visual acuity was-3.25ds/-1.50dc*180=0.4,the intraocular pressure was 19mmHg,the ring ridge was seen in the fundus after mydriasis,a large number of old laser spots and flat retina;The OCT showed that the macular structure of the left eye was complete and there was no subretinal fluid.Conclusion:Scleral cerclage+padding+vitrectomy+silicone oil filling is an effective treatment for retinal detachment(RD)after PIOL.展开更多
AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patie...AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.展开更多
文摘Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.
基金Supported by Wenzhou Basic Research Foundation(No.2024Y1244).
文摘AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This retrospective consecutive case series included patients with subluxated lenses by more than 180 degrees who underwent lens extraction,transcapsular scleral fixation of the standard CTR through equatorial capsulotomy,in-the-bag IOL implantation and with at least 6mo follow-up.Preoperative and postoperative best corrected visual acuity(BCVA),intraocular pressure(IOP),complications,and postoperative IOL tilt and decentration were recorded.RESULTS:Nine eyes of 7 patients with a mean followup of 11.0±3.7mo were included in this study.The BCVA was significantly improved from 0.64±0.22 logMAR preoperatively to 0.21±0.19 logMAR postoperatively(P<0.001).The IOP was within the normal range postoperatively.The mean tilt of the IOL was 4.30°±2.31°(range,1.0°to 8.9°)and the mean decentration of the IOL was 0.37±0.12 mm(range,0.14 to 0.50 mm).No visually threatened intraoperative and postoperative complications were detected during the follow-up period.CONCLUSION:This is a safe and effective surgical technique for managing patients with severely subluxated lenses.It has achieved favorable outcomes with fewer surgical manipulations and less need for advanced capsular support devices.
基金Supported by National Key Research and Development Program of China(No.2017YFC1104600)National Natural Science Foundation of China(No.81770909)。
文摘AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients.
文摘AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-70y)undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes)or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm)was significantly better in the trifocal group during all follow-up(P≤0.004)as well as 6-month uncorrected near(P=0.008)and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P〈0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision.
基金Supported by National Natural Science Foundation of China(No.81741058No.81460163+10 种基金No.81400427No.81300786)Fundamental Research Funds for the Central Universities(No.xjj2015015)Research Grants from Shaanxi Provincial Department of Science and Technology(No.2016KJXX-12No.2016JM8029)Specialized Research Fund for the Doctoral Program of Higher Education(No.20133601120012)Research Grants from Jiangxi Provincial Department of Science and Technology(No.20142BAB215029No.20132BAB205024No.20142BDH80005)Research Grants from Education Department of Jiangxi Province(No.GJJ14094No.GJJ13175)
文摘AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBASE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models. RESULTS: Four prospective randomized controlled trials (RCTs) and five cohorts provided data were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=.0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for uncorrected distance VA, and MD- -0.02; 95%CI, -0.03 to .0.00; Z=2.02, P=0.04 for corrected distance VA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=.0.01; 95%CI, -0.07 to 0.04; Z=0.42, P=-0.68 for distance-corrected near VA, and MD=-0.01; 95%CI, -0.06 to 0.03; Z=0.55, P=0.58 for corrected near VA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results. CONCLUSION: All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near VA.
文摘AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove.
文摘AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Electronic databases including PubMed,Embase, and the Cochrane Library were queried from their starting till January 2020. RCTs investigating the impact of hydrophobic versus hydrophilic acrylic intraocular lenses on PCO were considered eligible in this study. The pooled effect estimates were calculated using the random-effects model.RESULTS: Thirteen RCTs comprising of 939 patients(1263 eyes) were covered in this study. Patients with hydrophobic acrylic intraocular lenses had a lower PCO score than those with a hydrophilic acrylic intraocular lenses [standard mean difference:-1.80;95% confidence interval(CI):-2.62 to-0.98;P<0.001]. Moreover, the frequency of neodymium-doped yttrium aluminum garnet(Nd:YAG)capsulotomy in patients with hydrophobic acrylic intraocular lenses was significantly lower than patients with hydrophilic acrylic intraocular lenses(relative risk: 0.38;95%CI: 0.20-0.71;P=0.003).CONCLUSION: These findings suggest that hydrophobic acrylic intraocular lenses are superior to hydrophilic acrylic intraocular lenses in patients after cataract surgery due to lower PCO score and reduced Nd:YAG capsulotomy. While similar studies are conducted by other researchers, the present study conducted subgroup analyses that show superior results with hydrophobic lenses in trials conducted in western countries.
文摘AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group.
文摘AIM : To evaluate the prediction error in intraocular lens(IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position(ELP).METHODS: Retrospective study including a total of 25 eyes of 13 patients(age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL(Oculentis Gmb H, Germany). In all cases, an adjusted IOL power(P IOLadj) was calculated based on Gaussian optics using a variable keratometric index value(n kadj) for the estimation of the corneal power(P kadj) and on a new value for ELP(ELP adj) obtained by multiple regression analysis.This P IOLadj was compared with the IOL power implanted(P IOLReal) and the value proposed by three conventional formulas(Haigis, Hoffer Q and Holladay Ⅰ).RESULTS: P IOLReal was not significantly different than P IOLadj and Holladay IOL power(P 】0.05). In the Bland and Altman analysis, P IOLadj showed lower mean difference(-0.07 D) and limits of agreement(of 1.47 and-1.61 D)when compared to P IOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELP adj was significantly lower than ELP calculated with other conventional formulas(P 【0.01) and was found to be dependent on axial length, anterior chamber depth and P kadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing thekeratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
基金Supported partly by the General Natural Science Projects,Department of Education,Zhejiang Province,China(No.Y201636718)
文摘Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.
基金Supported by Key Research and Development Projects of Shaanxi Province(No.2017SF-246)Science and Technology Planning Project of Xi’an(No.2017116SF/YX010No.201805097YX5SF31)。
文摘·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.
文摘AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.
基金Supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) by the Ministry of Education, Science and Technology (No.NRF2016R1A2B4009626)
文摘AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including i Sert250 NC60(NC60), En Vista MX60(MX60), Acry Sof IQ SN60 WF(SN60 WF), TECNIS ZCB00(ZCB00), and TECNIS PCB00(PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via nonpreloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device(OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodiumstained OVD. RESULTS: The average time for IOL implantation was 22.0 s for NC60, 43.2 s for MX60, 32.3 s for SN60 WF, 41.4 s for ZCB00, and 14.6 s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60 WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION: IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems.
文摘【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
基金Zhejiang Medical Scientific Research Foundation, China (No.2009B075)Zhejiang Science and Technology Department Public Project, China (No.2010C33085)
文摘A 22-year-old patient suffering from both-side extreme hyperopia with amblyopia was corrected with an Artisan iris-fixated intraocular lens (IOL) implantation followed to clear lens extraction (CLE) with posterior chamber (PC)-IOL implantation. The preoperative refraction values were +17.75DS -1.50DC × 168° for the right eye and +17.25DS -0.75DC × 8° for the left eye. The uncorrected visual acuity (UCVA) was 20/200 bilaterally and the spectacle-corrected visual acuity (BSCVA) was 20/50 bilaterally. One year after Artisan iris-fixated IOL implantation, bilateral BSCVA was 20/50 with a refraction of +1.25DS -0.75DC × 13° for the right eye and +1.50DS -1.00DC × 55° for the left eye. The outcomes of an Artisan iris-fixated IOL implantation followed to CLE with PC-IOL implantation were encouraging for the correction of extreme hyperopia. Long term follow-up examinations were necessary for further determination of the efficacy and safety of this combinational procedure.
基金Science and Technology Department Technology Support Program of Qingdao,Shandong Province,China(No.2012-5-024-YY)
文摘Dear Sir,Iam Dr.Li-Na Meng,from the Qingdao Eye Hospital,Shandong Eye Institute,Shandong Academy of Medical Sciences,Qingdao,China.I want to present a rare case of secondary intraocular lens(IOL)implantation in an11-year-old boy who developed the complication of ciliary body detachment.When he was 2 years old,the boy underwent bilateral cataract extraction for congenital cataract in the other
基金National Natural Science Foundation of China(No.81860172)。
文摘Objective:To observe the changes of diagnosis and treatment of a patient with rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation in high myopia,and analyze its mechanism and treatment combined with the literature.Methods:To report a case of rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation.Result:Two months after the patient underwent scleral cerclage+pad pressing+vitrectomy+silicone oil filling,the fundus color photos showed that the vitreous cavity was filled with silicone oil,the fundus retina was flat,the cerclage ridge was obvious,and a large number of old laser spots.After the silicone oil in the eye was removed,the eye examination:the naked visual acuity of the left eye was 0.12,the corrected visual acuity was-3.25ds/-1.50dc*180=0.4,the intraocular pressure was 19mmHg,the ring ridge was seen in the fundus after mydriasis,a large number of old laser spots and flat retina;The OCT showed that the macular structure of the left eye was complete and there was no subretinal fluid.Conclusion:Scleral cerclage+padding+vitrectomy+silicone oil filling is an effective treatment for retinal detachment(RD)after PIOL.
文摘AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.