AIMTo determine the effect of pH, osmolality, and buffering system on the oxygen permeability (Dk) of soft contact lenses.METHODSTwo hydrogel lenses (nelfilcon A and etafilcon A) and 2 silicone hydrogel lenses (lotraf...AIMTo determine the effect of pH, osmolality, and buffering system on the oxygen permeability (Dk) of soft contact lenses.METHODSTwo hydrogel lenses (nelfilcon A and etafilcon A) and 2 silicone hydrogel lenses (lotrafilcon A and balafilcon A) were used in the study. These lenses were incubated in phosphate-buffered saline (PBS) and borate-buffered saline (BBS) solutions adjusted by 0.8 pH increments to a pH in the range of 5.8-9.0 or in hypotonic (280 mOsmol/kg), isotonic (310 mOsmol/kg) and hypertonic (380 mOsmol/kg) PBS solutions. Polarographic method was used for measuring the Dk and lenses were stacked as 4 layers to correct the boundary effect.RESULTSDk values of all contact lenses measured in BBS solutions were more stable than those in PBS solutions. Especially the etafilcon A lens showed a relative big change compared with other types of contact lenses at the same conditions. When the osmolality of PBS solution increased from hypotonic to hypertonic, Dk of all contact lenses decreased. Variations in Dk existed depending on lens materials, etafilcon A lens was the most affected and nelfilcon A was the least affected by osmolality.CONCLUSIONFrom the result obtained, it is revealed that Dk of contact lenses is changed by the pH, osmolality, and buffering condition of tear. Thus, Dk of contact lens can be varied by the lens wearers' physiological and/or pathological conditions.展开更多
Purpose: To investigate the cytotoxicity of soft contact lens multi-purpose care solutions which are now in common use in China.Methods: The cell culture method was used. Cytotoxicity was indicated by significant incr...Purpose: To investigate the cytotoxicity of soft contact lens multi-purpose care solutions which are now in common use in China.Methods: The cell culture method was used. Cytotoxicity was indicated by significant increases in the number of dead cells relative to controls.Results: Cells were exposed to soft contact lens care solutions for 15 min. They were irregular in shape and variable in size. The intercellular space increased and variable in size.The in-tercelluar space increased and the cells became scrunken. With the time of exposure elongated , damage of cells became more severe.Conclusions: Four kinds of soft contact lens multi-purpose care solutions may have harmful effects on the culture of human corneal epithelial cells. Soaked lenses should be rinsed with saline before being placed in the eyes in order to reduce the potential toxicity of contact lens care solutions. Eye science 1998; 14 :45 - 47.展开更多
文摘AIMTo determine the effect of pH, osmolality, and buffering system on the oxygen permeability (Dk) of soft contact lenses.METHODSTwo hydrogel lenses (nelfilcon A and etafilcon A) and 2 silicone hydrogel lenses (lotrafilcon A and balafilcon A) were used in the study. These lenses were incubated in phosphate-buffered saline (PBS) and borate-buffered saline (BBS) solutions adjusted by 0.8 pH increments to a pH in the range of 5.8-9.0 or in hypotonic (280 mOsmol/kg), isotonic (310 mOsmol/kg) and hypertonic (380 mOsmol/kg) PBS solutions. Polarographic method was used for measuring the Dk and lenses were stacked as 4 layers to correct the boundary effect.RESULTSDk values of all contact lenses measured in BBS solutions were more stable than those in PBS solutions. Especially the etafilcon A lens showed a relative big change compared with other types of contact lenses at the same conditions. When the osmolality of PBS solution increased from hypotonic to hypertonic, Dk of all contact lenses decreased. Variations in Dk existed depending on lens materials, etafilcon A lens was the most affected and nelfilcon A was the least affected by osmolality.CONCLUSIONFrom the result obtained, it is revealed that Dk of contact lenses is changed by the pH, osmolality, and buffering condition of tear. Thus, Dk of contact lens can be varied by the lens wearers' physiological and/or pathological conditions.
文摘Purpose: To investigate the cytotoxicity of soft contact lens multi-purpose care solutions which are now in common use in China.Methods: The cell culture method was used. Cytotoxicity was indicated by significant increases in the number of dead cells relative to controls.Results: Cells were exposed to soft contact lens care solutions for 15 min. They were irregular in shape and variable in size. The intercellular space increased and variable in size.The in-tercelluar space increased and the cells became scrunken. With the time of exposure elongated , damage of cells became more severe.Conclusions: Four kinds of soft contact lens multi-purpose care solutions may have harmful effects on the culture of human corneal epithelial cells. Soaked lenses should be rinsed with saline before being placed in the eyes in order to reduce the potential toxicity of contact lens care solutions. Eye science 1998; 14 :45 - 47.