The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning l...The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning laser ophthalmoscope(AOSLO)provides an excellent tool to acquire accurate and detailed information about the parafoveal area with cellular resolution.However,limited by the scanning speed of two-dimensional scanning,thefield of view(FOV)in the AOSLO system was usually less than or equal to 2,and the stitching for the parafoveal area required dozens of images,which was time-consuming and laborious.Unfortunately,almost half of patients are unable to obtain stitched images because of their poorfixation.To solve this problem,we integrate AO technology with the line-scan imaging method to build an adaptive optics line scanning ophthalmoscope(AOLSO)system with a larger FOV.In the AOLSO,afocal spherical mirrors in pairs are nonplanar arranged and the distance and angle between optical elements are optimized to minimize the aberrations,two cylinder lenses are orthogonally placed before the imaging sensor to stretch the point spread function(PSF)for sufficiently digitizing light energy.Captured human retinal images show the whole parafoveal area with 55FOV,60 Hz frame rate and cellular resolutions.Take advantage of the 5FOV of the AOLSO,only 9 frames of the retina are captured with several minutes to stitch a montage image with an FOV of 99,in which photoreceptor counting is performed within approximately 5eccentricity.The AOLSO system not only provides cellular resolution but also has the capability to capture the parafoveal region in a single frame,which offers great potential for noninvasive studying of the parafoveal area.展开更多
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was...The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation.展开更多
The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analy...The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analyzed.On this basis,a physical laser line scanning model is proposed.Afterwards,based on Fourier transform(FT)and segregation variablemethod(SVM),the heat conduction differential equation in laser line scanning thermography is derived in detail.The temperature field of the composite-based coatings model with defects is simulated numerically.The results show that the laser line scanning thermography can effectively detect the defects in the model.The correctness of the analytical calculation is verified by comparing the surface temperature distribution obtained by analytical calculation and numerical simulation.Additionally,an experiment is carried out and the changeable surface temperature obtained by analytical calculation is compared with the experimental results.It shows that the error of maximum temperature obtained by analytical calculation and by experiment is 8%with high accuracy,which proves the correctness of analytical calculation and enriches the theoretical foundation of laser line scanning thermography.展开更多
This paper analyzes the operation parameters of the time delay and integration (TDI) line scan CCD camera, such as resolution, line rate, clock frequency, etc. and their mathematical relationship is deduced. By analyz...This paper analyzes the operation parameters of the time delay and integration (TDI) line scan CCD camera, such as resolution, line rate, clock frequency, etc. and their mathematical relationship is deduced. By analyzing and calculating these parameters, the working clocks of the TDI CCD line scan camera are designed, which guarantees the synchronization of the line scan rate and the camera movement speed. The IL-E2 TDI CCD of DALSA Co. is used as the sensor of the camera in the paper. The working clock generator used for the TDI CCD sensor is realized by using the programmable logic device (PLD). The experimental results show that the working clock generator circuit satisfies the requirement of high speed TDI CCD line scan camera.展开更多
Using the method of line structure light produced by a laser diode,three dimensional profile measurement is deeply researched.A hardware circuit developed is used to get the center position of light section for the im...Using the method of line structure light produced by a laser diode,three dimensional profile measurement is deeply researched.A hardware circuit developed is used to get the center position of light section for the improvement of the measurement speed.A double CCD compensation technology is used to improve the measurement precision. An easy and effective calibration method of the least squares to fit the parameter of system structure is used to get the relative coordinate relationship of objects and images of light section in the directions of height and axis. Sensor scanning segment by segment and layer by layer makes the measurement range expand greatly.展开更多
Laser speckle imaging has been widely used for in-vivo visualization of blood perfusion in biological tissues.However,existing laser speckle imaging techniques suffer from limited quantification accuracy and spatial r...Laser speckle imaging has been widely used for in-vivo visualization of blood perfusion in biological tissues.However,existing laser speckle imaging techniques suffer from limited quantification accuracy and spatial resolution.Here we re-port a novel design and implementation of a powerful laser speckle imaging platform to solve the two critical limitations.The core technique of our platform is a combination of line scan confocal microscopy with laser speckle autocorrelation imaging,which is termed Line Scan Laser Speckle Autocorrelation Imaging(LS-LSAI).The technical advantages of LS-LSAI include high spatial resolution(~4.4μm)for visualizing and quantifying blood flow in microvessels,as well as video-rate imaging speed for tracing dynamic flow.展开更多
A fast motion estimation algorithm for variable block-size using the "line scan and block merge procedure" is proposed for airborne image compression modules.Full hardware implementation via FPGA is discussed in det...A fast motion estimation algorithm for variable block-size using the "line scan and block merge procedure" is proposed for airborne image compression modules.Full hardware implementation via FPGA is discussed in detail.The proposed pipelined architecture based on the line scan algorithm is capable of calculating the required 41 motion vectors of various size blocks supported by H.264 within a 16 × 16 block in parallel.An adaptive rate distortion cost function is used for various size block decision.The motion vectors of adjacent small blocks are merged to predict the motion vectors of larger blocks for reducing computation.Experimental results show that our proposed method has lower computational complexity than full search algorithm with slight quality decrease and little bit rate increase.Due to the high real-time processing speed it can be easily realized in hardware.展开更多
As a general format of the image,bitmap(BMP)image has wide applications,and consequently it is an important part of image processing.By segmenting the bitmap and combining the three-dimesional(3D)model of the discrete...As a general format of the image,bitmap(BMP)image has wide applications,and consequently it is an important part of image processing.By segmenting the bitmap and combining the three-dimesional(3D)model of the discrete algorithm with the scanning line compensation algorithm,a mathematical model is built.According to the topological relations between several control points on the model surface,the surface of the model is discretized,and a planar triangle sequence is used to describe 3D objects.Finally,the bitmap is enlarged by combining the borrowing compensation based on 3D modeling principle of discrete algorithm with the scanning line compensation algorithm of binary lattice image,thus getting a relatively clear enlarged BMP image.展开更多
An on-line full scan inspection system is developed for particle size analysis. A particle image is first obtained through optical line scan technology and is then analyzed using digital image processing. The system i...An on-line full scan inspection system is developed for particle size analysis. A particle image is first obtained through optical line scan technology and is then analyzed using digital image processing. The system is composed of a particle separation module, an image acquisition module, an image processing module, and an electric control module. Experiments are carried out using non-uniform 0.1 mm particles. The main advantage of this system consists of a full analysis of particles without any overlap or miss, thus improving the Area Scan Charge Coupled Device (CCD) acquisition problems. Particle size distribution, roundness, and sphericity can be obtained using the system with a deviation of repeated precision of around ±1%. The developed system is shown to be also convenient and versatile for any particle size and shape for academic and industrial users.展开更多
Fabrication of the surface micro-texture on the C-plane sapphire is undertaken by a355 nm Ultraviolet(UV)pulsed laser.The surface micro-textures of sapphire with different laser scanning line spacing ranging from 10 l...Fabrication of the surface micro-texture on the C-plane sapphire is undertaken by a355 nm Ultraviolet(UV)pulsed laser.The surface micro-textures of sapphire with different laser scanning line spacing ranging from 10 lm to 100 lm are obtained,where the selection range of scanning line spacing is controlled in the range of the groove width and plasma width to obtain a surface of high Peak-Valley(PV)value.A reasonable processing order is proposed to manufacture different types of surface micro-textures on sapphire by laser ablation trajectory regulation.In the multiple-passes laser ablation of sapphire by the UV nanosecond pulsed laser,the scanning lines in each direction is treated as once scanning.On this basis,the multiple processing can be carried out to avoid the influence of the subsequent scanning on the machined groove.In addition,the effect of different scanning line spacing on the PV value is quantified and different types of surface microtextures on sapphire,including the squares,the rhombuses and the hexagons,are successfully fabricated,which can be applied in the friction reduction or anti-reflection field.展开更多
基金supported by the National Natural Science Foundation of China under Grant No.62075235,National Key R&D Program of China under Grant No.2021YFF0700700Gusu Innovation and Entrepreneurship Leading Talents in Suzhou City under Grant No.ZXL2021425+1 种基金Youth Innovation Promotion Association of the Chinese Academy of Sciences under Grant No.2019320Innovation of Scientific Research Strategic Priority Research Program of the Chinese Academy of Sciences under Grant No.XDA15021304.
文摘The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning laser ophthalmoscope(AOSLO)provides an excellent tool to acquire accurate and detailed information about the parafoveal area with cellular resolution.However,limited by the scanning speed of two-dimensional scanning,thefield of view(FOV)in the AOSLO system was usually less than or equal to 2,and the stitching for the parafoveal area required dozens of images,which was time-consuming and laborious.Unfortunately,almost half of patients are unable to obtain stitched images because of their poorfixation.To solve this problem,we integrate AO technology with the line-scan imaging method to build an adaptive optics line scanning ophthalmoscope(AOLSO)system with a larger FOV.In the AOLSO,afocal spherical mirrors in pairs are nonplanar arranged and the distance and angle between optical elements are optimized to minimize the aberrations,two cylinder lenses are orthogonally placed before the imaging sensor to stretch the point spread function(PSF)for sufficiently digitizing light energy.Captured human retinal images show the whole parafoveal area with 55FOV,60 Hz frame rate and cellular resolutions.Take advantage of the 5FOV of the AOLSO,only 9 frames of the retina are captured with several minutes to stitch a montage image with an FOV of 99,in which photoreceptor counting is performed within approximately 5eccentricity.The AOLSO system not only provides cellular resolution but also has the capability to capture the parafoveal region in a single frame,which offers great potential for noninvasive studying of the parafoveal area.
基金supported by National Natural Science Foundation of China (52178422)Doctoral Research Foundation of Hubei University of Arts and Science (2059047)National College Students’Innovation and Entrepreneurship Training Program (202210519021).
文摘The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation.
基金supported by the National Natural Science Foundation of China(Grant No.52005495).
文摘The temperature field in laser line scanning thermography is investigated comprehensively in this work,including analytical calculation and experiment.Firstly,the principle of laser line scanning thermography is analyzed.On this basis,a physical laser line scanning model is proposed.Afterwards,based on Fourier transform(FT)and segregation variablemethod(SVM),the heat conduction differential equation in laser line scanning thermography is derived in detail.The temperature field of the composite-based coatings model with defects is simulated numerically.The results show that the laser line scanning thermography can effectively detect the defects in the model.The correctness of the analytical calculation is verified by comparing the surface temperature distribution obtained by analytical calculation and numerical simulation.Additionally,an experiment is carried out and the changeable surface temperature obtained by analytical calculation is compared with the experimental results.It shows that the error of maximum temperature obtained by analytical calculation and by experiment is 8%with high accuracy,which proves the correctness of analytical calculation and enriches the theoretical foundation of laser line scanning thermography.
基金Sponsored by the Research Fund of Harbin Institute of Technology (Grant No.HITMD 2001.18).
文摘This paper analyzes the operation parameters of the time delay and integration (TDI) line scan CCD camera, such as resolution, line rate, clock frequency, etc. and their mathematical relationship is deduced. By analyzing and calculating these parameters, the working clocks of the TDI CCD line scan camera are designed, which guarantees the synchronization of the line scan rate and the camera movement speed. The IL-E2 TDI CCD of DALSA Co. is used as the sensor of the camera in the paper. The working clock generator used for the TDI CCD sensor is realized by using the programmable logic device (PLD). The experimental results show that the working clock generator circuit satisfies the requirement of high speed TDI CCD line scan camera.
文摘Using the method of line structure light produced by a laser diode,three dimensional profile measurement is deeply researched.A hardware circuit developed is used to get the center position of light section for the improvement of the measurement speed.A double CCD compensation technology is used to improve the measurement precision. An easy and effective calibration method of the least squares to fit the parameter of system structure is used to get the relative coordinate relationship of objects and images of light section in the directions of height and axis. Sensor scanning segment by segment and layer by layer makes the measurement range expand greatly.
基金supports from Ministry of Education-Singapore(MOE2019-T2-2-094,R-397-000-327-114).
文摘Laser speckle imaging has been widely used for in-vivo visualization of blood perfusion in biological tissues.However,existing laser speckle imaging techniques suffer from limited quantification accuracy and spatial resolution.Here we re-port a novel design and implementation of a powerful laser speckle imaging platform to solve the two critical limitations.The core technique of our platform is a combination of line scan confocal microscopy with laser speckle autocorrelation imaging,which is termed Line Scan Laser Speckle Autocorrelation Imaging(LS-LSAI).The technical advantages of LS-LSAI include high spatial resolution(~4.4μm)for visualizing and quantifying blood flow in microvessels,as well as video-rate imaging speed for tracing dynamic flow.
基金Supported by the Aviation Science Fund of China(2009ZC15001)
文摘A fast motion estimation algorithm for variable block-size using the "line scan and block merge procedure" is proposed for airborne image compression modules.Full hardware implementation via FPGA is discussed in detail.The proposed pipelined architecture based on the line scan algorithm is capable of calculating the required 41 motion vectors of various size blocks supported by H.264 within a 16 × 16 block in parallel.An adaptive rate distortion cost function is used for various size block decision.The motion vectors of adjacent small blocks are merged to predict the motion vectors of larger blocks for reducing computation.Experimental results show that our proposed method has lower computational complexity than full search algorithm with slight quality decrease and little bit rate increase.Due to the high real-time processing speed it can be easily realized in hardware.
基金National Natural Science Foundation of China(Nos.61162016,61562057)Natural Science Foundation of Gansu Province(No.18JR3RA124)+1 种基金Science and Technology Program Project of Gansu Province(Nos.18JR3RA104,1504FKCA038)Science and Technology Project of Gansu Education Department(No.2017D-08)
文摘As a general format of the image,bitmap(BMP)image has wide applications,and consequently it is an important part of image processing.By segmenting the bitmap and combining the three-dimesional(3D)model of the discrete algorithm with the scanning line compensation algorithm,a mathematical model is built.According to the topological relations between several control points on the model surface,the surface of the model is discretized,and a planar triangle sequence is used to describe 3D objects.Finally,the bitmap is enlarged by combining the borrowing compensation based on 3D modeling principle of discrete algorithm with the scanning line compensation algorithm of binary lattice image,thus getting a relatively clear enlarged BMP image.
文摘An on-line full scan inspection system is developed for particle size analysis. A particle image is first obtained through optical line scan technology and is then analyzed using digital image processing. The system is composed of a particle separation module, an image acquisition module, an image processing module, and an electric control module. Experiments are carried out using non-uniform 0.1 mm particles. The main advantage of this system consists of a full analysis of particles without any overlap or miss, thus improving the Area Scan Charge Coupled Device (CCD) acquisition problems. Particle size distribution, roundness, and sphericity can be obtained using the system with a deviation of repeated precision of around ±1%. The developed system is shown to be also convenient and versatile for any particle size and shape for academic and industrial users.
基金supported by the National Natural Science Foundation of China(No.51805257)the China Postdoctoral Science Foundation(No.2019TQ0151)+3 种基金the National Natural Science Foundation of China for Creative Research Groups(No.51921003)the Foundation of Graduate Innovation Center in NUAA,China(No.KFJJ20190502)the Postgraduate Research&Practice Innovation Program of Jiangsu Province,China(No.KYCX19_0162)the Jiangsu Key Laboratory of Precision and Micro-Manufacturing Technology,China。
文摘Fabrication of the surface micro-texture on the C-plane sapphire is undertaken by a355 nm Ultraviolet(UV)pulsed laser.The surface micro-textures of sapphire with different laser scanning line spacing ranging from 10 lm to 100 lm are obtained,where the selection range of scanning line spacing is controlled in the range of the groove width and plasma width to obtain a surface of high Peak-Valley(PV)value.A reasonable processing order is proposed to manufacture different types of surface micro-textures on sapphire by laser ablation trajectory regulation.In the multiple-passes laser ablation of sapphire by the UV nanosecond pulsed laser,the scanning lines in each direction is treated as once scanning.On this basis,the multiple processing can be carried out to avoid the influence of the subsequent scanning on the machined groove.In addition,the effect of different scanning line spacing on the PV value is quantified and different types of surface microtextures on sapphire,including the squares,the rhombuses and the hexagons,are successfully fabricated,which can be applied in the friction reduction or anti-reflection field.