High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass...High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%.展开更多
Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selectio...Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.展开更多
The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performa...The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV.展开更多
Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. Th...Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1–7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of μ_(v) = 2.1 × 10^(-11)μ_(B).However, tritium backgrounds or solar axion interaction in this energy window are equally plausible causes.Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With O(100) kton·year exposure of liquid scintillator to solar neutrinos, a sensitivity of μ_(v) < 10^(-11)μ_(B) can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present.展开更多
Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a sel...Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV.展开更多
An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measure...An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments.展开更多
As a unique probe,the precision measurement of pp solar neutrinos is important for studying the sun’s energy mechanism as it enables monitoring the thermodynamic equilibrium and studying neutrino oscillations in the ...As a unique probe,the precision measurement of pp solar neutrinos is important for studying the sun’s energy mechanism as it enables monitoring the thermodynamic equilibrium and studying neutrino oscillations in the vacuum-dominated region.For a large-scale liquid scintillator detector,a bottleneck for pp solar neutrino detection is the pile-up events of intrinsic14C decay.This paper presents a few approaches to discriminating between pp solar neutrinos and ^(14)C pile-up events by considering the differences in their time and spatial distributions.In this study,a Geant4-based Monte Carlo simulation is conducted.Multivariate analysis and deep learning technology are adopted to investigate the capability of ^(14)C pile-up reduction.The BDTG (boosted decision trees with gradient boosting) model and VGG network demonstrate good performance in discriminating pp solar neutrinos and ^(14)C double pile-up events.Under the ^(14)C concentration assumption of 5×10-18g/g,the signal significance can achieve 10.3 and 15.6 using the statistics of only one day.In this case,the signal efficiency for discrimination using the BDTG model while rejecting 99.18% ^(14)C double pile-up events is 51.1%,and that for the case where the VGG network is used while rejecting 99.81%of the ^(14)C double pile-up events is 42.7%.展开更多
In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors b...In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.展开更多
Neutron background measurement is always very important for dark matter detection due to almost the same effect for the recoiled nucleus scattered off by the incident neutron and dark matter particle. For deep under-g...Neutron background measurement is always very important for dark matter detection due to almost the same effect for the recoiled nucleus scattered off by the incident neutron and dark matter particle. For deep under-ground experiments, the flux of neutron background is so low that large-scale detection is usually necessary. In this paper, by using Geant4, the relationship between detection efficiency and volume is investigated, meanwhile, two geometrical schemes for this detection including a single large-sized detector and arrayed multi-detector are compared under the condition of the same volume. The geometrical parameters of detectors are filtrated and detection efficiencies obtained under the similar background condition of China Jingping Underground Laboratory (CJPL). The results show that for a large-scale Gd-doped liquid scintillation detector, the detection efficiency increases with the size of detector at the beginning and then trends toward a constant. Under the condition of the same length and cross section, the arrayed multi-detector has almost similar detection performance as the single large-sized detector, while too much detector number could cause degeneration of detection performance. Considering engineering factors, such as testing, assembling and production, the 4 × 4 arrayed detector scheme is flexible and more suitable. Furthermore, the conditions for using fast and slow signal coincidence detection and the detectable lower limit of neutron energy are evaluated by simulating the light process.展开更多
A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in...A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in Lab VIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources ^22 Na,^137Cs and ^60 Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing(DSP) algorithms can discriminate neutrons from γ-rays. Moreover,the zero-crossing method shows better n-γ discrimination at 80 ke Vee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit(FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γseparation for fission neutrons.展开更多
A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was...A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee).展开更多
Based on some important domestic and international references,the third γ multiplicity measurement equation is derived,but it is different from the results given in current researches.The neutron multiplicity equatio...Based on some important domestic and international references,the third γ multiplicity measurement equation is derived,but it is different from the results given in current researches.The neutron multiplicity equation is deduced in this paper,especially the fourth fast-neutron multiplicity equation based on the liquid scintillation detectors,which is more complex than the other multiplicity equations up to the fourth order.The equations given in this paper can be used to verify the validity and availability of principles for the multiplicity measurement up to the fourth order,and extend the application scopes of the neutron multiplicity measurement,such as correcting the additional measurement value to eliminate influences for dead times.It will be the foundation of nuclear researches,if the higher order multiplicity measurement is important for nuclear materials’control and accountability.展开更多
The Jiangmen Underground Neutrino Observatory(JUNO)is a large liquid scintillator detector designed to explore many topics in fundamental physics.In this study,the potential of searching for proton decay in the p→νK...The Jiangmen Underground Neutrino Observatory(JUNO)is a large liquid scintillator detector designed to explore many topics in fundamental physics.In this study,the potential of searching for proton decay in the p→νK^(+)mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification.Moreover,the excellent energy resolution of JUNO permits suppression of the sizable background caused by other delayed signals.Based on these advantages,the detection efficiency for the proton decay via p→νK^(+)is 36.9%±4.9%with a background level of 0.2±0.05(syst)±0.2(stat)events after 10 years of data collection.The estimated sensitivity based on 200 kton-years of exposure is 9.6×1033 years,which is competitive with the current best limits on the proton lifetime in this channel and complements the use of different detection technologies.展开更多
基金supported by the National Key R&D Program of China(No.2018YFA0404100)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.12175257)+1 种基金the National Natural Science Foundation of China(No.12175257)the Science Foundation of High-Level Talents of Wuyi University(No.2021AL027).
文摘High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%.
基金supported by the National Natural Science Foundation of China(Nos.11805294 and 11975021)the China Postdoctoral Science Foundation(2018M631013),the Strategic Priority Research Program of Chinese Academy of Sciences(XDA10010900)+1 种基金the Fundamental Research Funds for the Central Universities,Sun Yatsen University(19lgpy268)in part by the CAS Center for Excellence in Particle Physics(CCEPP).
文摘Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.
基金supported by the National Natural Science Foundation of China(Nos.11975021,12175257,12175321,11675275,and U1932101)the Guangdong Basic and Applied Basic Research Foundation(No.2021A1515012039)+3 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA10010900)the National College Students Science and Technology Innovation Projectthe Undergraduate Base Scientific Research Project of Sun Yat-sen Universitythe CAS Center for Excellence in Particle Physics(CCEPP).
文摘The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV.
基金Supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. XDA10010800)the Double First Class Start-up Fund (WF220442603) provided by Shanghai Jiao Tong Universitysupport from the CAS Center for Excellence in Particle Physics (CCEPP)。
文摘Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1–7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of μ_(v) = 2.1 × 10^(-11)μ_(B).However, tritium backgrounds or solar axion interaction in this energy window are equally plausible causes.Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With O(100) kton·year exposure of liquid scintillator to solar neutrinos, a sensitivity of μ_(v) < 10^(-11)μ_(B) can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present.
基金supported by the National Magnetic Confinement Fusion Program of China(No.2019YFE03020002)the National Natural Science Foundation of China(Nos.12205085 and12125502)。
文摘Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV.
基金supported by the State Key Development Program for Basic Research of China (Nos. 2008CB717803, 2009GB107001,2007CB209903)the Research Fund for the Doctoral Program of Higher Education of China (No. 200610011023)National Natural Science Foundation of China (No. 10875002)
文摘An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments.
基金supported by National Natural Science Foundation of China(No.12005044)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA10011200)Guangxi Science and Technology Program(No.GuiKeAD21220037).
文摘As a unique probe,the precision measurement of pp solar neutrinos is important for studying the sun’s energy mechanism as it enables monitoring the thermodynamic equilibrium and studying neutrino oscillations in the vacuum-dominated region.For a large-scale liquid scintillator detector,a bottleneck for pp solar neutrino detection is the pile-up events of intrinsic14C decay.This paper presents a few approaches to discriminating between pp solar neutrinos and ^(14)C pile-up events by considering the differences in their time and spatial distributions.In this study,a Geant4-based Monte Carlo simulation is conducted.Multivariate analysis and deep learning technology are adopted to investigate the capability of ^(14)C pile-up reduction.The BDTG (boosted decision trees with gradient boosting) model and VGG network demonstrate good performance in discriminating pp solar neutrinos and ^(14)C double pile-up events.Under the ^(14)C concentration assumption of 5×10-18g/g,the signal significance can achieve 10.3 and 15.6 using the statistics of only one day.In this case,the signal efficiency for discrimination using the BDTG model while rejecting 99.18% ^(14)C double pile-up events is 51.1%,and that for the case where the VGG network is used while rejecting 99.81%of the ^(14)C double pile-up events is 42.7%.
基金the Ministry of Science and Technology of China(No.2016YFA0400301)the grants for the XENON Dark Matter Project。
文摘In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.
基金Supported by National Natural Science Foundation of China (10935005, 10945002)
文摘Neutron background measurement is always very important for dark matter detection due to almost the same effect for the recoiled nucleus scattered off by the incident neutron and dark matter particle. For deep under-ground experiments, the flux of neutron background is so low that large-scale detection is usually necessary. In this paper, by using Geant4, the relationship between detection efficiency and volume is investigated, meanwhile, two geometrical schemes for this detection including a single large-sized detector and arrayed multi-detector are compared under the condition of the same volume. The geometrical parameters of detectors are filtrated and detection efficiencies obtained under the similar background condition of China Jingping Underground Laboratory (CJPL). The results show that for a large-scale Gd-doped liquid scintillation detector, the detection efficiency increases with the size of detector at the beginning and then trends toward a constant. Under the condition of the same length and cross section, the arrayed multi-detector has almost similar detection performance as the single large-sized detector, while too much detector number could cause degeneration of detection performance. Considering engineering factors, such as testing, assembling and production, the 4 × 4 arrayed detector scheme is flexible and more suitable. Furthermore, the conditions for using fast and slow signal coincidence detection and the detectable lower limit of neutron energy are evaluated by simulating the light process.
基金Supported by National Natural Science Foundation of China(91226107,11305229)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA03030300)
文摘A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in Lab VIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources ^22 Na,^137Cs and ^60 Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing(DSP) algorithms can discriminate neutrons from γ-rays. Moreover,the zero-crossing method shows better n-γ discrimination at 80 ke Vee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit(FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γseparation for fission neutrons.
文摘A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee).
文摘Based on some important domestic and international references,the third γ multiplicity measurement equation is derived,but it is different from the results given in current researches.The neutron multiplicity equation is deduced in this paper,especially the fourth fast-neutron multiplicity equation based on the liquid scintillation detectors,which is more complex than the other multiplicity equations up to the fourth order.The equations given in this paper can be used to verify the validity and availability of principles for the multiplicity measurement up to the fourth order,and extend the application scopes of the neutron multiplicity measurement,such as correcting the additional measurement value to eliminate influences for dead times.It will be the foundation of nuclear researches,if the higher order multiplicity measurement is important for nuclear materials’control and accountability.
基金supported by the Chinese Academy of Sciencesthe National Key R&D Program of China+22 种基金the CAS Center for Excellence in Particle PhysicsWuyi Universitythe Tsung-Dao Lee Institute of Shanghai Jiao Tong University in Chinathe Institut National de Physique Nucléaire et de Physique de Particules (IN2P3) in Francethe Istituto Nazionale di Fisica Nucleare (INFN) in Italythe Italian-Chinese collaborative research program MAECI-NSFCthe Fond de la Recherche Scientifique (F.R.S-FNRS)FWO under the "Excellence of Science-EOS" in Belgiumthe Conselho Nacional de Desenvolvimento Científico e Tecnològico in Brazilthe Agencia Nacional de Investigacion y Desarrollo in Chilethe Charles University Research Centrethe Ministry of Education,Youth,and Sports in Czech Republicthe Deutsche Forschungsgemeinschaft (DFG)the Helmholtz Associationthe Cluster of Excellence PRISMA+ in Germanythe Joint Institute of Nuclear Research (JINR)Lomonosov Moscow State University in Russiathe joint Russian Science Foundation (RSF)National Natural Science Foundation of China (NSFC) research programthe MOST and MOE in Taiwan,Chinathe Chulalongkorn UniversitySuranaree University of Technology in Thailandthe University of California at Irvine in USA
文摘The Jiangmen Underground Neutrino Observatory(JUNO)is a large liquid scintillator detector designed to explore many topics in fundamental physics.In this study,the potential of searching for proton decay in the p→νK^(+)mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification.Moreover,the excellent energy resolution of JUNO permits suppression of the sizable background caused by other delayed signals.Based on these advantages,the detection efficiency for the proton decay via p→νK^(+)is 36.9%±4.9%with a background level of 0.2±0.05(syst)±0.2(stat)events after 10 years of data collection.The estimated sensitivity based on 200 kton-years of exposure is 9.6×1033 years,which is competitive with the current best limits on the proton lifetime in this channel and complements the use of different detection technologies.