Through experimental analysis of the liquid flows in a flow channel instrument, prompt evaluation of the physically defined viscosity of non-Newtonian liquid foods was investigated for development into a structurally ...Through experimental analysis of the liquid flows in a flow channel instrument, prompt evaluation of the physically defined viscosity of non-Newtonian liquid foods was investigated for development into a structurally simple and easy-to-use viscometer. For Newtonian and non-Newtonian test liquids, a relation between the friction coefficient and Reynolds number, which was dimensionless as derived from an expression of analysis as a gravity current, indicated a condition under which the flow in the instrument was laminar and under which an average shear rate was on the order of less than 1 s~. Prediction organized based on this empirical relation reproduced practically the flow curve determined for the liquid foods using a rotor type viscometer. Utilization of the channel instrument as a viscometer was formulated in terms of physical meanings of measurements such as the flow length and elapsed time.展开更多
This paper provides a model to identify the most appropriate packaging system (i.e. the industrial process by which the product is hygienically coupled with the container) for different liquid foods. The model devel...This paper provides a model to identify the most appropriate packaging system (i.e. the industrial process by which the product is hygienically coupled with the container) for different liquid foods. The model developed is grounded on the Analytic Network Process (ANP) methodology, a powerful and flexible tool used in decision making. To select the appropriate packaging system, the model takes into account several factors, including packaging material, cost, safety, performance (e.g., speed and accuracy), plant reliability and flexibility, which may directly or indirectly affect the suitability of the process. Moreover, the chemical and physical properties of commercial liquid foods, and the packaging technology are included in the model as further variables to be considered for the final choice. We try to answer the following research questions: is a filling system appropriate for a given liquid food? Is it compatible with a defined packaging technology? When several filling systems are available for a given liquid food, how can the most appropriate one be selected? The ease of application of the model and the robustness of the results provided have been tested on a sample of 59 commercial liquid foods, for which the model allowed to identify the most suitable packaging system, providing useful practical guidelines. The model was developed in close collaboration with a panel of experts, operating in the beverage bottling industry, and validated by the same experts; thus, the resulting tool is suitable for use as a decision support system by food and bottling industries.展开更多
Ohmic heating is a food processing method in which alternating current(AC)went through a food sample and resulted in internal energy generation in foods.It is an alternative fast heating technique.Its principal advant...Ohmic heating is a food processing method in which alternating current(AC)went through a food sample and resulted in internal energy generation in foods.It is an alternative fast heating technique.Its principal advantage is the ability to rapidly and uniformly heat food materials of various densities.During ohmic heating,change in electrical conductivity was observed.The intensity of food materials’electrical conductivity or overall resistance critically controls ohmic heating rate.An ohmic heating set-up was prepared under this project.Tomato juice was heated(about 32℃ to 80℃)in a batch type ohmic heater at different voltage gradients in the range of 50-70 V/cm.It was statistically found that the voltage gradient had significant impact on conductivity and system performance coefficient(SPC)(P<0.05).It was concluded that the electrical conductivity values linearly increased with temperature.The SPCs of the system ranged between 0.779 and 0.943.The value of R2 of the linear model was greater than 0.98.展开更多
[Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were...[Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were pre-treated by QuEChERS technology and detected by Exactive liquid chromatography-high resolution mass spectrometry.The liquid chromatography-high-resolution mass spectrometry for detecting the residues of diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food was established.[Result]Diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide showed a good linear correlation in the range of 2.0-50.0μg/L(r^2〉0.99).The average recoveries of these four compounds in bovine power at the spiked levels of 2,10 and 20μg/kg were 74.5%-90.1%,and the relative standard deviations(RSD)were 15.4%-17.5%.[Conclusion]This method was stable and reliable,and could be used to detect diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food.展开更多
A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methyl...A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cobalt and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, a preconcentration factor of 8 was reached. The detection limit for cobalt was 12.4 ng?mL–1, and the relative standard deviation (RSD) was 3.42% (n = 7, c = 100 ng?mL–1). The method was successfully applied to the determination of cobalt in food, environmental and water samples.展开更多
As a novel technology,supported liquid membrane extraction has gradually become the direction of the research of extraction,for the advantages of using little organic solvents,good selectivity and repeatability.This p...As a novel technology,supported liquid membrane extraction has gradually become the direction of the research of extraction,for the advantages of using little organic solvents,good selectivity and repeatability.This paper is based on describing the working principle,structure and infiuencing factors of supported liquid membrane,and research in domestic and foreign literatures which are in the same period, and give a review on the application of supported liquid membrane in meat security determination.展开更多
Catechins in green tea have various useful features including antioxidant activity and preventive effects on metabolic syndrome. Various beverages that are enriched with tea catechins are marketed as Foods for Specifi...Catechins in green tea have various useful features including antioxidant activity and preventive effects on metabolic syndrome. Various beverages that are enriched with tea catechins are marketed as Foods for Specified Health Uses (FOSHU) in Japan. However, recent reports have indicated that excessive consumption of green tea extracts as a dietary supplement are associated with adverse health effects such as liver disorders. Various catechins and caffeine are constituents of FOSHU tea-based beverages. The amount of catechins in FOSHU products is displayed on labels as total catechin content, but the content of individual catechins are not provided. Although health hazards of FOSHU products have rarely been reported, precise information about the content and types of catechins in FOSHU products is needed to ensure safety. We used high-performance liquid chromatography with a photodiode array (HPLC/PDA) to simultaneously identify and quantify catechins and caffeine in green tea-based popular beverages and FOSHU beverages. This technique allowed simultaneous quantitation of five types of catechins and caffeine in green tea without complicated sample preparation. Epigallocatechin gallate (EGCG) and epigallocatechin EGC were the main catechins in various FOSHU beverages and the concentrations of almost all catechins were higher in FOSHU, than in popular green tea-based beverages. The concentrations of EGCG in green tea-based popular beverages and in FOSHU beverages were 5.4 - 7.3 and 10.2 - 41.9 mg/100mL, respectively, with the highest concentration being in a product named Healthya (approximately 147 mg/bottle). The simultaneous determination of compounds such as catechins and caffeine in FOSHU beverages can help to estimate beneficial and adverse effects to prevent deleterious effects on health and the excessive consumption of FOSHU beverages containing high concentrations of tea catechins should be avoided.展开更多
文摘Through experimental analysis of the liquid flows in a flow channel instrument, prompt evaluation of the physically defined viscosity of non-Newtonian liquid foods was investigated for development into a structurally simple and easy-to-use viscometer. For Newtonian and non-Newtonian test liquids, a relation between the friction coefficient and Reynolds number, which was dimensionless as derived from an expression of analysis as a gravity current, indicated a condition under which the flow in the instrument was laminar and under which an average shear rate was on the order of less than 1 s~. Prediction organized based on this empirical relation reproduced practically the flow curve determined for the liquid foods using a rotor type viscometer. Utilization of the channel instrument as a viscometer was formulated in terms of physical meanings of measurements such as the flow length and elapsed time.
文摘This paper provides a model to identify the most appropriate packaging system (i.e. the industrial process by which the product is hygienically coupled with the container) for different liquid foods. The model developed is grounded on the Analytic Network Process (ANP) methodology, a powerful and flexible tool used in decision making. To select the appropriate packaging system, the model takes into account several factors, including packaging material, cost, safety, performance (e.g., speed and accuracy), plant reliability and flexibility, which may directly or indirectly affect the suitability of the process. Moreover, the chemical and physical properties of commercial liquid foods, and the packaging technology are included in the model as further variables to be considered for the final choice. We try to answer the following research questions: is a filling system appropriate for a given liquid food? Is it compatible with a defined packaging technology? When several filling systems are available for a given liquid food, how can the most appropriate one be selected? The ease of application of the model and the robustness of the results provided have been tested on a sample of 59 commercial liquid foods, for which the model allowed to identify the most suitable packaging system, providing useful practical guidelines. The model was developed in close collaboration with a panel of experts, operating in the beverage bottling industry, and validated by the same experts; thus, the resulting tool is suitable for use as a decision support system by food and bottling industries.
文摘Ohmic heating is a food processing method in which alternating current(AC)went through a food sample and resulted in internal energy generation in foods.It is an alternative fast heating technique.Its principal advantage is the ability to rapidly and uniformly heat food materials of various densities.During ohmic heating,change in electrical conductivity was observed.The intensity of food materials’electrical conductivity or overall resistance critically controls ohmic heating rate.An ohmic heating set-up was prepared under this project.Tomato juice was heated(about 32℃ to 80℃)in a batch type ohmic heater at different voltage gradients in the range of 50-70 V/cm.It was statistically found that the voltage gradient had significant impact on conductivity and system performance coefficient(SPC)(P<0.05).It was concluded that the electrical conductivity values linearly increased with temperature.The SPCs of the system ranged between 0.779 and 0.943.The value of R2 of the linear model was greater than 0.98.
基金Supported by Scientific Research Projects of General Administration of Quality Supervision,Inspection and Quarantine“Standard Sample Development and Production System Construction of Animal-derived Veterinary Drugs”(20130143)
文摘[Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were pre-treated by QuEChERS technology and detected by Exactive liquid chromatography-high resolution mass spectrometry.The liquid chromatography-high-resolution mass spectrometry for detecting the residues of diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food was established.[Result]Diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide showed a good linear correlation in the range of 2.0-50.0μg/L(r^2〉0.99).The average recoveries of these four compounds in bovine power at the spiked levels of 2,10 and 20μg/kg were 74.5%-90.1%,and the relative standard deviations(RSD)were 15.4%-17.5%.[Conclusion]This method was stable and reliable,and could be used to detect diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food.
文摘A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cobalt and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, a preconcentration factor of 8 was reached. The detection limit for cobalt was 12.4 ng?mL–1, and the relative standard deviation (RSD) was 3.42% (n = 7, c = 100 ng?mL–1). The method was successfully applied to the determination of cobalt in food, environmental and water samples.
文摘As a novel technology,supported liquid membrane extraction has gradually become the direction of the research of extraction,for the advantages of using little organic solvents,good selectivity and repeatability.This paper is based on describing the working principle,structure and infiuencing factors of supported liquid membrane,and research in domestic and foreign literatures which are in the same period, and give a review on the application of supported liquid membrane in meat security determination.
文摘Catechins in green tea have various useful features including antioxidant activity and preventive effects on metabolic syndrome. Various beverages that are enriched with tea catechins are marketed as Foods for Specified Health Uses (FOSHU) in Japan. However, recent reports have indicated that excessive consumption of green tea extracts as a dietary supplement are associated with adverse health effects such as liver disorders. Various catechins and caffeine are constituents of FOSHU tea-based beverages. The amount of catechins in FOSHU products is displayed on labels as total catechin content, but the content of individual catechins are not provided. Although health hazards of FOSHU products have rarely been reported, precise information about the content and types of catechins in FOSHU products is needed to ensure safety. We used high-performance liquid chromatography with a photodiode array (HPLC/PDA) to simultaneously identify and quantify catechins and caffeine in green tea-based popular beverages and FOSHU beverages. This technique allowed simultaneous quantitation of five types of catechins and caffeine in green tea without complicated sample preparation. Epigallocatechin gallate (EGCG) and epigallocatechin EGC were the main catechins in various FOSHU beverages and the concentrations of almost all catechins were higher in FOSHU, than in popular green tea-based beverages. The concentrations of EGCG in green tea-based popular beverages and in FOSHU beverages were 5.4 - 7.3 and 10.2 - 41.9 mg/100mL, respectively, with the highest concentration being in a product named Healthya (approximately 147 mg/bottle). The simultaneous determination of compounds such as catechins and caffeine in FOSHU beverages can help to estimate beneficial and adverse effects to prevent deleterious effects on health and the excessive consumption of FOSHU beverages containing high concentrations of tea catechins should be avoided.