期刊文献+
共找到139篇文章
< 1 2 7 >
每页显示 20 50 100
Application of an Organophosphorus Compound-DEPBT as Coupling Reagent in Liquid Phase Peptide Synthesis
1
作者 Yan Nei HE Yao LIN(Department of Chemistry. Beijing University. Beijing 100871) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第9期749-750,共2页
DEPBT, a novel coupling reagent containing phosphorus, was used in synthesis of pentapeptide Boc-Ile-Asn-Met-Trp(For)-Gly.OMe by solution method.
关键词 Application of an Organophosphorus Compound-DEPBT as Coupling reagent in liquid Phase Peptide Synthesis MET
下载PDF
Ionic Liquid Based Vilsmeier Reagent as an Efficient Reagent for Esterification of Alcohols and Carboxylic Acids
2
作者 Ahmed Ali Hullio G. M. Mastoi Hassan Imran 《International Journal of Organic Chemistry》 2018年第1期125-134,共10页
The Vilsmeier reagent is well-known electrophilic reagent for synthetically useful organic transformations. Its ionic liquid version has been prepared from DMF-like ionic liquid. Apart from its other reported applicat... The Vilsmeier reagent is well-known electrophilic reagent for synthetically useful organic transformations. Its ionic liquid version has been prepared from DMF-like ionic liquid. Apart from its other reported applications, presently it has been used as an efficient organo reagent for efficient esterification. Variety of esters has been prepared from versatile carboxylic acids and alcohols under ionic liquid conditions with excellent yields. The present system offers an economically and environmentally better alternative to routine procedures. 展开更多
关键词 DEHYDRATION Agent Ionic liquid BASED Vilsmeier reagent ESTERIFICATION
下载PDF
土壤中Sb(Ⅲ)和Sb(Ⅴ)的有效提取与测定
3
作者 陈皓 刘硕勋 +1 位作者 陈玲 杨超 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第8期1270-1277,共8页
锑的各种形态中三价锑和五价锑的毒性较高,在城市土壤锑组成中占比也较高。研究了萃取方式、萃取剂、萃取条件、色谱分离流动相条件等因素对土壤中价态锑提取和分析的影响,建立了完整的土壤价态锑萃取-分析方法。研究推荐以柠檬酸溶液... 锑的各种形态中三价锑和五价锑的毒性较高,在城市土壤锑组成中占比也较高。研究了萃取方式、萃取剂、萃取条件、色谱分离流动相条件等因素对土壤中价态锑提取和分析的影响,建立了完整的土壤价态锑萃取-分析方法。研究推荐以柠檬酸溶液为萃取剂,70℃恒温振荡萃取的方式提取价态锑,萃取液以乙二胺四乙酸二钾+邻苯二甲酸为流动相,经色谱分离后利用电感耦合等离子体质谱仪对不同价态的Sb进行分析。所建立的方法检出限低,准确性精密度好,可用于实际土壤样品中价态锑的有效提取与测定。 展开更多
关键词 价态锑 道路土壤 试剂萃取 液相色谱-电感耦合等离子体质谱联用法
下载PDF
超高效液相色谱在洗洁精表面活性剂检测中的应用
4
作者 李艳平 《化工设计通讯》 CAS 2024年第10期21-22,28,共3页
为了能够更加精准地检测洗洁精表面活性剂含量,提出超高效液相色谱在洗洁精表面活性剂检测中的应用研究。考虑到大部分洗洁精应用的表面活性物质均为甜菜碱或氧化胺类物质,设置了以甜菜碱和氧化胺类物质为核心的超高效液相色谱试剂,选择... 为了能够更加精准地检测洗洁精表面活性剂含量,提出超高效液相色谱在洗洁精表面活性剂检测中的应用研究。考虑到大部分洗洁精应用的表面活性物质均为甜菜碱或氧化胺类物质,设置了以甜菜碱和氧化胺类物质为核心的超高效液相色谱试剂,选择U3000高效液相色谱仪,日本新宇宙XP-302M电雾式检测器以及Acclaim Surfactant Plus分析柱作为具体的测试装置,对测试环境温度和U3000高效液相色谱仪的流速进行定值设置后,按照乙腈洗脱执行梯度对色谱柱进行处理后,将满足线性范畴的数据作为计算洗洁精表面活性剂含量的基础参数,带入到回归方程中,确定各表面活性剂含量,对应的检测结果误差稳定在0.015%以内,单一类别洗洁精表面活性剂含量检测结果误差稳定在0.003%以内。 展开更多
关键词 超高效液相色谱 洗洁精表面活性剂 液相色谱试剂 U3000高效液相色谱仪 分析柱 洗脱梯度 线性范畴 回归方程
下载PDF
悬浮污泥过滤工艺优化与应用
5
作者 曲鹏 《油气田地面工程》 2024年第10期90-95,共6页
某油田采用SSF(悬浮污泥过滤)技术处理采出水,设计出水执行Q/SY DQ 0605—2006《大庆油田油藏水驱注水水质指标及分析方法》中规定的“8·3·2”标准。近年由于受诸多因素影响导致出站水质达标率低,为提高出站水质,该油田组织... 某油田采用SSF(悬浮污泥过滤)技术处理采出水,设计出水执行Q/SY DQ 0605—2006《大庆油田油藏水驱注水水质指标及分析方法》中规定的“8·3·2”标准。近年由于受诸多因素影响导致出站水质达标率低,为提高出站水质,该油田组织开展了现场调研,对采出水进行分析及处理工艺评价,找出了影响达标率的4个关键因素,制定了相应优化对策。依据调研情况,从3个方面开展技术攻关研究:优化药剂,开展水处理工艺药剂筛选,优选杀菌剂,提升杀菌效果,同时筛选SSF工艺药剂,提升悬浮污泥层密实度;优化工艺,开展SSF工艺污泥层构建现场试验及水力冲击试验,并重新校核SSF工艺处理能力;优化管理,调整工艺运行参数,延长沉降段沉降时间,定期组织容器清淤、收油、排泥工作,提高油、悬浮物固体的去除率。通过以上工作,实现了出站水质中菌类浓度达标率100%,滤后含油浓度达标、悬浮物固体浓度下降,逐步提高了出站水质达标率。结果表明,对SSF处理工艺进行的优化与应用能够促进出站水质指标的提升,对今后采出水站优化运行、改扩建等方面具有很好的指导意义。 展开更多
关键词 悬浮污泥过滤 达标率 药剂筛选 污泥层构建 水力冲击 液位运行
下载PDF
MBTH法和HPLC法测定汽车内饰挥发甲醛含量对比
6
作者 蒋喆 《浙江化工》 CAS 2024年第7期42-49,共8页
甲醛是环境中普遍存在的化学污染物质。车内相关环境中也存在甲醛,因此需要对甲醛的浓度进行测定,以达到治理污染的目的。本文利用3-甲基-2-苯并噻唑啉酮腙盐酸盐法(MBTH)和高效液相色谱法(HPLC)对汽车内饰挥发的甲醛进行比较测试,发现M... 甲醛是环境中普遍存在的化学污染物质。车内相关环境中也存在甲醛,因此需要对甲醛的浓度进行测定,以达到治理污染的目的。本文利用3-甲基-2-苯并噻唑啉酮腙盐酸盐法(MBTH)和高效液相色谱法(HPLC)对汽车内饰挥发的甲醛进行比较测试,发现MBTH法在试验条件下可以快速测得甲醛浓度,使用便捷、实用性较强。但针对各种汽车内饰零件挥发形成的复杂空气环境,甲醛的定性定量测定以HPLC法为佳。 展开更多
关键词 车内空气 甲醛 甲醛测试仪 酚试剂法 高效液相色谱法
下载PDF
Ionic liquid/tetraglyme hybrid Mg[TFSI]_2 electrolytes for rechargeable Mg batteries 被引量:3
7
作者 Zheng Ma Maria Forsyth +1 位作者 Douglas R.MacFarlane Mega Kar 《Green Energy & Environment》 SCIE CSCD 2019年第2期146-153,共8页
The electrochemical reversibility of Mg in hybrid electrolytes based on mixtures of ionic liquid and glyme based organic solvents was investigated for applications in rechargeable magnesium batteries(RMBs). The electr... The electrochemical reversibility of Mg in hybrid electrolytes based on mixtures of ionic liquid and glyme based organic solvents was investigated for applications in rechargeable magnesium batteries(RMBs). The electrolytes demonstrate reversible reduction and oxidation of Mg only after being pre-treated with the dehydrating agent, magnesium borohydride, Mg[BH_4]_2, highlighting the importance of removing water in Mg based electrolytes. The addition magnesium di[bis(trifluoromethanesulfonyl)imide](Mg[TFSI]_2)(0.3 M) to N-butyl-n-methyl-pyrrolidinium bis(trifluoromethanesulfonyl)imide [C4 mpyr][TFSI]/tetraglyme at a mole ratio of 1:2 showed stable CV cycling over almost 300 cycles while scanning electron microscopy(SEM) and X-ray diffraction(XRD) confirmed Mg deposition, showing non-dendritic morphology and a well-aligned growth. Further thermogravimetric analysis(TGA) demonstrated a mass retention of 79% at 250℃ for this electrolyte suggesting that the presence of the ionic liquid increases thermal stability substantially making these hybrid electrolytes compatible for RMBs. 展开更多
关键词 Mg[TFSI]2 IONIC liquids Tetraglyme RECHARGEABLE Mg BATTERY Mg[BH4]2 dehydrate reagent
下载PDF
混合分散固相萃取联合柱前衍生高效液相色谱法测定蜂蜜中草甘膦残留
8
作者 郭新颖 谢超 《化学分析计量》 CAS 2023年第6期30-33,共4页
建立蜂蜜样品中强极性农药草甘膦的多壁碳纳米管(MWCNTs)和十八烷基硅烷键合硅胶(C18)混合分散固相萃取联合柱前试剂衍生的高效液相色谱测定方法。蜂蜜样品经水溶解后,震荡超声提取草甘膦,提取液先经60 mgMWCNTs和120mgC18混合分散固相... 建立蜂蜜样品中强极性农药草甘膦的多壁碳纳米管(MWCNTs)和十八烷基硅烷键合硅胶(C18)混合分散固相萃取联合柱前试剂衍生的高效液相色谱测定方法。蜂蜜样品经水溶解后,震荡超声提取草甘膦,提取液先经60 mgMWCNTs和120mgC18混合分散固相吸附剂吸附净化,然后用1.0mg/mL9-芴基氯甲酸酯乙腈溶液进行柱前试剂衍生。目标组分经色谱柱分离后采用荧光检测器检测。草甘膦的质量浓度在0.005~5.00μg/mL范围内与色谱峰面积具有良好的线性关系,相关系数为0.9999,方法检出限为0.025 mg/kg。样品加标回收率为78.1%~92.3%,测定结果的相对标准偏差为2.8%~8.4%(n=6)。该方法可为食品卫生监管部门提供技术参考。 展开更多
关键词 草甘膦 蜂蜜 柱前试剂衍生 高效液相色谱法 荧光检测器
下载PDF
Investigation of the Low Molecular Weight Thiol Composition in a Metastatic Prostate Cancer Cell Line (LNCaP) by LC-UV-MS and NMR after Labelling with the Ellman Reagent
9
作者 Stephen Childs Nicolas Haroune +1 位作者 Lee Williams Michael Gronow 《American Journal of Analytical Chemistry》 2017年第1期1-18,共18页
The low molecular weight thiols present in the deproteinized extract of a prostate cancer cell line (LNCaP-FGC) were analysed after derivatization with the Ellman reagent (ESSE). The mixed disulphides formed (RSSE) we... The low molecular weight thiols present in the deproteinized extract of a prostate cancer cell line (LNCaP-FGC) were analysed after derivatization with the Ellman reagent (ESSE). The mixed disulphides formed (RSSE) were fractionated, characterized and quantified by liquid chromatography on a C-18 column using UV detection. This revealed the presence, in femtomoles per cell, of glutathione (8.30 ± 0.73), cysteine (2.71 ± 0.04) and cysteinylglycine (0.83 ± 0.10), accounting for the bulk of the thiol present. Further analysis of the cell extracts using a novel and sensitive mass spectrometry technique allowed the detection of low level of an additional derivative which was identified as cysteinylglycerate using NMRspectroscopy. 展开更多
关键词 Prostate Cancer Low Molecular Weight THIOLS THIOL Analysis Ultra-High Performance liquid Chromatography Novel THIOL LC-MS NMR Ellman’s reagent
下载PDF
轨道交通甲醛测试方法的适用性对比
10
作者 吕秀文 张杰 +2 位作者 张晓成 汤亮 杨建平 《皮革制作与环保科技》 2023年第6期61-63,共3页
一直以来,甲醛因其具有危险性而备受关注,是轨道交通环境中的主要有害物质之一。本文分析了三种测定甲醛常用方法的优缺点:一种是色谱方法,在液相色谱柱上分离并通过检测器进行甲醛检测;另外一种测试甲醛的精密方法是酚试剂分光光度法;... 一直以来,甲醛因其具有危险性而备受关注,是轨道交通环境中的主要有害物质之一。本文分析了三种测定甲醛常用方法的优缺点:一种是色谱方法,在液相色谱柱上分离并通过检测器进行甲醛检测;另外一种测试甲醛的精密方法是酚试剂分光光度法;最后一种是用电化学甲醛分析仪测定甲醛。三种方法各有其优点和限制,本文主要针对测定轨道交通车辆内甲醛含量的不同方法展开讨论,以期为轨道交通行业中测定甲醛含量提供技术参考。 展开更多
关键词 轨道交通 甲醛 液相色谱法 酚试剂法
下载PDF
利用TRIzol 试剂和液氮提取大鼠胰腺高质量总RNA 被引量:10
11
作者 李冬民 任吴超 +6 位作者 王璇 王飞苗 高玉 韩燕 宁启兰 宋天保 吕社民 《西安交通大学学报(医学版)》 CAS CSCD 北大核心 2009年第5期639-642,共4页
目的建立胰腺高质量总RNA快速、经济、稳定的提取方法。方法应用TRIzol试剂和液氮提取大鼠胰腺总RNA,通过总RNA含量和A260/280比值的测定及10 g/L非变性琼脂糖凝胶电泳评估总RNA的质量,并用RT-PCR检测大鼠胰岛素1、胰高血糖素、胰α-... 目的建立胰腺高质量总RNA快速、经济、稳定的提取方法。方法应用TRIzol试剂和液氮提取大鼠胰腺总RNA,通过总RNA含量和A260/280比值的测定及10 g/L非变性琼脂糖凝胶电泳评估总RNA的质量,并用RT-PCR检测大鼠胰岛素1、胰高血糖素、胰α-淀粉酶和β-actin的表达。结果利用TRIzol和液氮提取的大鼠胰腺总RNA量可达到3~6μg/mg胰腺组织,A260/280比值在1.75~1.89之间。在10 g/L非变性琼脂糖凝胶电泳时,均可见28S及18S条带,并且在28S、18S条带间可见明显的云雾状阴影。大鼠胰岛素1、胰高血糖素、胰α-淀粉酶、β-actin RT-PCR产物电泳结果显示均有清晰的条带。结论应用TRIzol试剂和液氮成功地提取了大鼠胰腺高质量的总RNA,后者可用于RT-PCR研究。 展开更多
关键词 大鼠胰腺 总RNA提取 TRIzol试剂 液氮
下载PDF
离子液体载催化剂和载试剂在有机合成中的应用 被引量:23
12
作者 刘宝友 韩菊 +2 位作者 董建芳 魏福祥 程彦海 《有机化学》 SCIE CAS CSCD 北大核心 2007年第10期1236-1243,共8页
综述了离子液体载催化剂和载试剂在有机合成中的应用进展.离子液体载催化剂是针对离子液体中催化剂难以回收利用的问题提出来的,它不仅可以实现均相催化,而且反应产物容易分离,催化剂可以循环使用.离子液体载有机试剂合成,又称为离子液... 综述了离子液体载催化剂和载试剂在有机合成中的应用进展.离子液体载催化剂是针对离子液体中催化剂难以回收利用的问题提出来的,它不仅可以实现均相催化,而且反应产物容易分离,催化剂可以循环使用.离子液体载有机试剂合成,又称为离子液体相有机合成,具有固相反应产物纯度高和液相反应反应快的优点.在离子液体载无机试剂的反应中,反应物毒性降低,反应条件温和,产物选择性好. 展开更多
关键词 离子液体 有机合成 应用 催化剂 试剂
下载PDF
葡萄酒中游离氨基酸的高效液相色谱法测定 被引量:10
13
作者 刘保东 王维 +2 位作者 关家锐 王吉顺 王淑仁 《分析测试学报》 CAS CSCD 1997年第6期5-7,共3页
采用邻苯二甲醛衍生化法衍生葡萄酒中的游离氨基酸,以反相高效液相色谱法对葡萄酒中18种氨基酸进行了测定,方法简单、迅速,25min即可完成18种氨基酸的分离。精密度及回收率实验结果令人满意。
关键词 葡萄酒、氨基酸 反相高效液相色谱法 衍生化
下载PDF
液体试剂与干粉试剂酶法测定血清总二氧化碳的实验对比 被引量:3
14
作者 罗梅 朱晓玲 张迎玖 《检验医学》 CAS 北大核心 2004年第6期511-513,共3页
目的 评价液体试剂与干粉试剂酶法测定血清总二氧化碳 (TCO2 )的可靠性。方法 依据美国国家临床实验室标准化委员会 (NCCLS)有关文件对 2种试剂测定血清TCO2 进行相关性比较并对其线性、精密度进行评价。结果 液体试剂与干粉试剂相... 目的 评价液体试剂与干粉试剂酶法测定血清总二氧化碳 (TCO2 )的可靠性。方法 依据美国国家临床实验室标准化委员会 (NCCLS)有关文件对 2种试剂测定血清TCO2 进行相关性比较并对其线性、精密度进行评价。结果 液体试剂与干粉试剂相关良好 (r =0 .976 0 ) ,预期相对偏差在 15mmol/L时为 0 .0 7% ,在 2 5mmol/L时为 0 .16 % ,在 5 0mmol/L时为 0 .2 2 %。 2种试剂的线性范围均较宽 ,线性回归方程分别为Y =0 .995 9X - 1.4 2 92和Y =0 .9787X - 0 .5 74 8,r分别为 0 .9998和 0 .9997。 2种试剂的精密度均很好 ,其批内不精密度及总不精密度 (CV)均 <6 .1%。结论 液体试剂与干粉试剂测定血清中的TCO2 的相关性、线性、精密度均很好 ,具有可比性 ,而液体试剂使用更为方便。 展开更多
关键词 液体试剂 干粉试剂酶法 测定 血清 总二氧化碳 实验对比
下载PDF
5,10,15,20-四(3-溴-4-磺酸苯基)卟啉高效液相色谱法测定河水中微量钴、铜、锌 被引量:9
15
作者 许峰 应玲 +2 位作者 胡斌 陈建荣 汤福隆 《色谱》 CSCD 北大核心 1994年第3期208-209,211,共3页
研究了新合成的显色剂5,10,15,20-四(3-溴-4磺酸苯基)卟啉与Co(Ⅱ)、Zn(Ⅱ)、Cu(Ⅱ)形成配合物离子的反应,在ZORBAXODS柱上,用含20mmol/L 乙酸-乙酸钠(pH6.0)和10mmol... 研究了新合成的显色剂5,10,15,20-四(3-溴-4磺酸苯基)卟啉与Co(Ⅱ)、Zn(Ⅱ)、Cu(Ⅱ)形成配合物离子的反应,在ZORBAXODS柱上,用含20mmol/L 乙酸-乙酸钠(pH6.0)和10mmol/L四乙基碘化铵的乙腈-水(27:73,V/V)流动相洗脱,在420nm波长下检测。Co(Ⅱ)、Zn(Ⅱ)、Cu(Ⅱ)赘合物在9min内获得完全分离,检测限分别为0.2ng,0.05ng和0.09ng。该方法已用于河水样中钴、锌、铜的测定。 展开更多
关键词 HPLC 螯合物 水质分析
下载PDF
多环苯基环己烷类液晶的合成 被引量:10
16
作者 赵敏 蒯乃功 《华东理工大学学报(自然科学版)》 CAS CSCD 1996年第2期217-220,共4页
利用零价钯催化偶联sp^2-sp^2的反应,合成了4个(两个系列)三环、四环苯基环己烷类液晶化合物。偶联反应产率达75%左右。
关键词 液晶 芳基硼酸 偶联 相变 多环苯基环己烷
下载PDF
反相离子对高效液相色谱法测定杀虫单 被引量:3
17
作者 曾唏 牟兰 +1 位作者 卢玉振 张长庚 《分析试验室》 CAS CSCD 1999年第3期58-60,共3页
用反相离子对色谱法测定了杀虫单原粉中杀虫单的含量,色谱柱为SpherisorbODSI250mm·4.0mmi.d.5μm。流动相为0.025mol/L磷酸二氢钾-0.005mol/L四乙基溴化铵(pH6~7),... 用反相离子对色谱法测定了杀虫单原粉中杀虫单的含量,色谱柱为SpherisorbODSI250mm·4.0mmi.d.5μm。流动相为0.025mol/L磷酸二氢钾-0.005mol/L四乙基溴化铵(pH6~7),检测波长242nm。在此条件下,杀虫单原粉中杀虫单与杂质完全分离,方法操作简便,快速准确,可用于原粉中杀虫单的分析。 展开更多
关键词 杀虫剂 测定 杀虫单 反相离子对 高效液相色谱
下载PDF
国产液体血凝试剂在Stago血凝仪上的性能评价 被引量:3
18
作者 林云 施雄飞 +1 位作者 汪先桃 郭晓梅 《临床和实验医学杂志》 2010年第22期1716-1717,共2页
目的评价国产液体血凝试剂在法国Stago血凝仪上的性能。方法选择成人血浆样本285例,分别使用国产液体血凝试剂和法国Stago血凝仪原装试剂,在Stago血凝仪上进行凝血酶原时间、活化部分凝血活酶时间、纤维蛋白原和凝血酶时间4项凝血指标检... 目的评价国产液体血凝试剂在法国Stago血凝仪上的性能。方法选择成人血浆样本285例,分别使用国产液体血凝试剂和法国Stago血凝仪原装试剂,在Stago血凝仪上进行凝血酶原时间、活化部分凝血活酶时间、纤维蛋白原和凝血酶时间4项凝血指标检测,检测结果参考美国临床实验室修正法规1988(CLIA'88)标准要求进行统计分析。结果国产液体血凝试剂的检测结果与Stago原装血凝试剂的检测结果相比,均符合美国CLIA'88标准要求,二者检测结果无显著性差异。结论国产液体血凝试剂可以代替进口原装试剂在Stago血凝仪上用于凝血4项临床实验检测。 展开更多
关键词 液体血凝试剂 国产 Stago血凝仪 凝血指标
下载PDF
高粘性液体试剂的自动化微量分配系统 被引量:2
19
作者 刘亚欣 陈立国 +1 位作者 孙立宁 荣伟彬 《机械工程学报》 EI CAS CSCD 北大核心 2009年第2期100-105,共6页
在膜蛋白结晶等生物工程领域,常需要对高粘性生物试剂进行精确的分配和转移操作。研制一套液体操作机器人系统,它可以实现纳升级别高粘性试剂的精确分配操作。介绍该系统的结构原理,主要由运动控制模块、分配控制模块和液滴体积检测模... 在膜蛋白结晶等生物工程领域,常需要对高粘性生物试剂进行精确的分配和转移操作。研制一套液体操作机器人系统,它可以实现纳升级别高粘性试剂的精确分配操作。介绍该系统的结构原理,主要由运动控制模块、分配控制模块和液滴体积检测模块等组成,分别用来实现液滴的精确分配操作和体积检测功能。接下来对影响试剂分配过程的因素进行分析,给出成功实现微量试剂液滴分配操作时,分配头与基板之间高度必须满足的临界高度范围。针对具有不同粘度的三种试剂进行分配试验,验证理论分析结果,结果表明该系统分配精度小于7%,重复精度(用变异系数表示)小于10%。 展开更多
关键词 液体分配 粘性试剂 液滴体积检测
下载PDF
ADVIA120血液分析仪过氧化物酶鞘液试剂的研制与应用 被引量:5
20
作者 陈林 张莉滟 +1 位作者 丁海明 庄俊华 《临床检验杂志》 CAS CSCD 北大核心 2005年第5期350-352,共3页
目的探讨自配过氧化物酶鞘液试剂是否能应用于ADVIA120血液分析仪。方法分析原装试剂成分、理化指标;研制效果相同的试剂,并作一系列比对试验。结果自配试剂的各项检测指标:N(%)、L(%)、M(%)、E(%)、B(%)、LUC(%)、WBCP等与进口试剂的... 目的探讨自配过氧化物酶鞘液试剂是否能应用于ADVIA120血液分析仪。方法分析原装试剂成分、理化指标;研制效果相同的试剂,并作一系列比对试验。结果自配试剂的各项检测指标:N(%)、L(%)、M(%)、E(%)、B(%)、LUC(%)、WBCP等与进口试剂的检测结果基本一致,无显著性差异。结论自配的过氧化物酶鞘液试剂可替代进口试剂用于ADVIA120血液分析仪。 展开更多
关键词 血液分析仪 试剂 鞘液
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部