期刊文献+
共找到9,189篇文章
< 1 2 250 >
每页显示 20 50 100
Optimal guidance strategy for flexible load based on hybrid direct load control and time of use 被引量:1
1
作者 Siyang Liu Yuan Gao +2 位作者 Hejun Yang Xinghua Xie Yinghao Ma 《Global Energy Interconnection》 EI CSCD 2023年第3期297-307,共11页
The time-of-use(TOU)strategy can effectively improve the energy consumption mode of customers,reduce the peak-valley difference of load curve,and optimize the allocation of energy resources.This study presents an Opti... The time-of-use(TOU)strategy can effectively improve the energy consumption mode of customers,reduce the peak-valley difference of load curve,and optimize the allocation of energy resources.This study presents an Optimal guidance mechanism of the flexible load based on strategies of direct load control and time-of-use.First,this study proposes a period partitioning model,which is based on a moving boundary technique with constraint factors,and the Dunn Validity Index(DVI)is used as the objective to solve the period partitioning.Second,a control strategy for the curtailable flexible load is investigated,and a TOU strategy is utilized for further modifying load curve.Third,a price demand response strategy for adjusting transferable load is proposed in this paper.Finally,through the case study analysis of typical daily flexible load curve,the efficiency and correctness of the proposed method and model are validated and proved. 展开更多
关键词 Flexible load Optimal demand response strategy Time of use Period partitioning Direct load control
下载PDF
Three-Dimensional Water Quality Model Based on FVCOM for Total Load Control Management in Guan River Estuary,Northern Jiangsu Province 被引量:1
2
作者 ZHANG Li LIN Weibo +6 位作者 LI Keqiang SHENG Jianming WEI Aihong LUO Feng WANG Yan WANG Xiulin ZHANG Longjun 《Journal of Ocean University of China》 SCIE CAS 2016年第2期261-270,共10页
Guan River Estuary and adjacent coastal area(GREC) suffer from serious pollution and eutrophicational problems over the recent years.Thus,reducing the land-based load through the national pollutant total load control ... Guan River Estuary and adjacent coastal area(GREC) suffer from serious pollution and eutrophicational problems over the recent years.Thus,reducing the land-based load through the national pollutant total load control program and developing hydrodynamic and water quality models that can simulate the complex circulation and water quality kinetics within the system,including longitudinal and lateral variations in nutrient and COD concentrations,is a matter of urgency.In this study,a three-dimensional,hydrodynamic,water quality model was developed in GREC,Northern Jiangsu Province.The complex three-dimensional hydrodynamics of GREC were modeled using the unstructured-grid,finite-volume,free-surface,primitive equation coastal ocean circulation model(FVCOM).The water quality model was adapted from the mesocosm nutrients dynamic model in the south Yellow Sea and considers eight compartments:dissolved inorganic nitrogen,soluble reactive phosphorus(SRP),phytoplankton,zooplankton,detritus,dissolved organic nitrogen(DON),dissolved organic phosphorus(DOP),and chemical oxygen demand.The hydrodynamic and water quality models were calibrated and confirmed for 2012 and 2013.A comparison of the model simulations with extensive dataset shows that the models accurately simulate the longitudinal distribution of the hydrodynamics and water quality.The model can be used for total load control management to improve water quality in this area. 展开更多
关键词 water quality model FVCOM total load control management Guan River Estuary Yellow Sea
下载PDF
Multi-Agent Consensus Control Scheme for the Load Control Problem
3
作者 Te Xu Zhixian Lin +4 位作者 Xinwei Lin Changsheng Lin Feng Gao Zixuan Li Peiwen Liu 《Energy Engineering》 EI 2022年第4期1501-1515,共15页
With the help of smart grid technologies,a lot of electrical loads can provide demand response to support the active power balance of the grid.Compared with centralized control methods,decentralized methods reduce the... With the help of smart grid technologies,a lot of electrical loads can provide demand response to support the active power balance of the grid.Compared with centralized control methods,decentralized methods reduce the computational burden of the control center and enhance the reliability of the communication.In this paper,a novel second-order multi-agent consensus control method is proposed for load control problem.By introducing the velocity state into the model,the proposed method achieves better performance than traditional ones.Simulation results verify the effectiveness of the proposed method. 展开更多
关键词 MULTI-AGENT decentralized control load control
下载PDF
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
4
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode control Constant Power load (CPL) Current-Sensorless control Extended State Observer
下载PDF
Novel Optimal Load Control for Power System Frequency and Voltage Regulation
5
作者 Yaxin Wang Donglian Qi +1 位作者 Jianliang Zhang Jingcheng Mei 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第6期1746-1755,共10页
The sudden generation-consumption imbalance is becoming more frequent in modern power systems, causing voltage and frequency stability issues. One potential solution is load participation in primary control. We formul... The sudden generation-consumption imbalance is becoming more frequent in modern power systems, causing voltage and frequency stability issues. One potential solution is load participation in primary control. We formulate a novel optimal load control(NOLC) problem that aims to minimize the disutility of controllable loads in providing primary regulation. In this paper, we show that the network dynamics, coupled with welldefined load control(obtained via optimality condition), can be seen as an optimization algorithm to solve the dual problem of NOLC. Unlike most existing load control frameworks that only consider frequency response, our load-side primary control focuses on frequency, voltage, and aggregate cost. Simulation results imply that the NOLC approach can ensure better frequency and voltage regulations. Moreover, the coordination between NOLC and other devices enabled in the system, the NOLC performance against the total size of controllable loads, and the NOLC effectiveness in a multi-machine power system are also verified in MATLAB/Simulink. 展开更多
关键词 Novel optimal load control(NOLC) primary regulation frequency response voltage stability smart load
原文传递
A Sender-Initiated Fuzzy Logic Contrnol Method for Network Load Balancing
6
作者 Ming-Chang Huang 《Journal of Computer and Communications》 2024年第8期110-122,共13页
In this paper, a sender-initiated protocol is applied which uses fuzzy logic control method to improve computer networks performance by balancing loads among computers. This new model devises sender-initiated protocol... In this paper, a sender-initiated protocol is applied which uses fuzzy logic control method to improve computer networks performance by balancing loads among computers. This new model devises sender-initiated protocol for load transfer for load balancing. Groups are formed and every group has a node called a designated representative (DR). During load transferring processes, loads are transferred using the DR in each group to achieve load balancing purposes. The simulation results show that the performance of the protocol proposed is better than the compared conventional method. This protocol is more stable than the method without using the fuzzy logic control. 展开更多
关键词 load Balancing Fuzzy Logic control Sender-Initiated
下载PDF
Distributed Model Predictive Load Frequency Control of Multi-area Power System with DFIGs 被引量:16
7
作者 Yi Zhang Xiangjie Liu Bin Qu 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第1期125-135,共11页
Reliable load frequency control LFC is crucial to the operation and design of modern electric power systems. Considering the LFC problem of a four-Area interconnected power system with wind turbines, this paper presen... Reliable load frequency control LFC is crucial to the operation and design of modern electric power systems. Considering the LFC problem of a four-Area interconnected power system with wind turbines, this paper presents a distributed model predictive control DMPC based on coordination scheme. The proposed algorithm solves a series of local optimization problems to minimize a performance objective for each control area. The generation rate constraints GRCs, load disturbance changes, and the wind speed constraints are considered. Furthermore, the DMPC algorithm may reduce the impact of the randomness and intermittence of wind turbine effectively. A performance comparison between the proposed controller with and without the participation of the wind turbines is carried out. Analysis and simulation results show possible improvements on closed-loop performance, and computational burden with the physical constraints. © 2014 Chinese Association of Automation. 展开更多
关键词 Asynchronous generators Electric control equipment Electric fault currents Electric frequency control Electric load management Electric power systems Model predictive control Optimization Press load control WIND Wind turbines
下载PDF
Direct load control by distributed imperialist competitive algorithm 被引量:4
8
作者 Fengji LUO Junhua ZHAO +3 位作者 Haiming WANG Xiaojiao TONG Yingying CHEN Zhao Yang DONG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第4期385-395,共11页
Demand side management techniques have drawn significant attentions along with the development of smart grid.This paper proposes a new direct load control(DLC)model for scheduling interruptible air conditioner loads.T... Demand side management techniques have drawn significant attentions along with the development of smart grid.This paper proposes a new direct load control(DLC)model for scheduling interruptible air conditioner loads.The model is coordinated with the unit commitment and economic dispatch to minimize the total operation cost over the whole dispatch horizon.The network constraints are also considered in the model.To ensure the thermal comfort of the occupants,we are among the first to incorporate the advanced two-parameter thermal inertia dynamical model of customer houses into the DLC model to calculate the indoor temperature variation.This paper also proposes a distributed imperialist competitive algorithm to effectively solve the model.The simulation studies prove the efficiency of the proposed methodology. 展开更多
关键词 Direct load control Imperialist competitive algorithm Demand side management
原文传递
Aerodynamic load control on a dynamically pitching wind turbine airfoil using leading-edge protuberance method 被引量:4
9
作者 Y.N.Zhang M.M.Zhang +1 位作者 C.Cai J.Z.Xu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2020年第2期275-289,共15页
The aerodynamic loads of wind turbine blades are substantially affected by dynamic stall induced by the variations of the angle of attack of local airfoil sections.The purpose of the present study is to explore the ef... The aerodynamic loads of wind turbine blades are substantially affected by dynamic stall induced by the variations of the angle of attack of local airfoil sections.The purpose of the present study is to explore the effect of leading-edge protuberances on the fluctuation of the aerodynamic performances for wind turbine airfoil during dynamic stall.An experimental investigation is carried out by a direct force measurement technique employing force balance at a Reynolds number Re=2×105.The phase-averaged and instantaneous aerodynamic loads of the pitching airfoil,including the baseline and the wavy airfoil,are presented and analyzed.The phase-averaged results indicate that the effects of dynamic stall for the wavy airfoil can be delayed or minimized compared to the baseline airfoil,and the negative damping area of the wavy airfoil is significant decreased in full-stall condition.These effects of leading-edge protuberances are more notable at a higher reduced frequency.For the instantaneous aerodynamic loads of the wavy airfoil,there is an observable reduction in fluctuations compared with baseline case.Furthermore,spectral analysis is applied to quantitatively undercover the nonstationary features of the instantaneous aerodynamic loads.It is found that the leading edge protuberances can reduce the harmonics of the aerodynamic force signal,and enhance the stability of the aerodynamic loads under different reduced frequencies.In conclusion,leading-edge protuberances are found effective to reduce the fluctuation characteristics of the aerodynamic loads during the dynamic stall process,and help to improve the stability and prolong the service life of the wind turbine blades. 展开更多
关键词 Wind turbine airfoil Dynamic stall loads control Leading-edge protuberance Aerodynamic experiment
原文传递
Decentralized Resilient H_∞Load Frequency Control for Cyber-Physical Power Systems Under DoS Attacks 被引量:2
10
作者 Xin Zhao Suli Zou Zhongjing Ma 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2021年第11期1737-1751,共15页
This paper designs a decentralized resilient H_(∞)load frequency control(LFC)scheme for multi-area cyber-physical power systems(CPPSs).Under the network-based control framework,the sampled measurements are transmitte... This paper designs a decentralized resilient H_(∞)load frequency control(LFC)scheme for multi-area cyber-physical power systems(CPPSs).Under the network-based control framework,the sampled measurements are transmitted through the communication networks,which may be attacked by energylimited denial-of-service(DoS)attacks with a characterization of the maximum count of continuous data losses(resilience index).Each area is controlled in a decentralized mode,and the impacts on one area from other areas via their interconnections are regarded as the additional load disturbance of this area.Then,the closed-loop LFC system of each area under DoS attacks is modeled as an aperiodic sampled-data control system with external disturbances.Under this modeling,a decentralized resilient H_(∞)scheme is presented to design the state-feedback controllers with guaranteed H∞performance and resilience index based on a novel transmission interval-dependent loop functional method.When given the controllers,the proposed scheme can obtain a less conservative H_(∞)performance and resilience index that the LFC system can tolerate.The effectiveness of the proposed LFC scheme is evaluated on a one-area CPPS and two three-area CPPSs under DoS attacks. 展开更多
关键词 Cyber-physical power systems(CPPSs) denial-of-service(DoS)attacks load frequency control(LFC) sampled-data control
下载PDF
The Velocity Synchronizing Control on the Electro-Hydraulic Load Simulator 被引量:39
11
作者 焦宗夏 高俊霞 +1 位作者 华清 王少萍 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2004年第1期39-46,共8页
This paper builds up an accurate nonlinear mathematical model of anelectro-hydraulic force/ torque servo control system, and provides a thorough theoretical analysison the feedforward compensation for extraneous force... This paper builds up an accurate nonlinear mathematical model of anelectro-hydraulic force/ torque servo control system, and provides a thorough theoretical analysison the feedforward compensation for extraneous force/torque, whose limitation is analyzed andrevealed. The nonlinear factors and the servo valve dynamics have much influence on the systemcharacteristics. Subsequently a velocity syn-chronizing-compensation method by using the controlsignal of the control actuator is proposed, which can reduce the lagging effects for the betterperformance. For the reason of similarity between the model of control actuator and that of the loadsimulator, the proposed method performs well against the influence of nonlinear factors. Thesimulations and the experiments confirm that this control scheme results in a quick response,robustness, and excellent ability against disturbance. 展开更多
关键词 load simulator synchronizing control extraneous force/torque
下载PDF
Multi-objective optimization for voltage and frequency control of smart grids based on controllable loads 被引量:2
12
作者 Yaxin Wang Donglian Qi Jianliang Zhang 《Global Energy Interconnection》 CAS CSCD 2021年第2期136-144,共9页
The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capabi... The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capability for nodal-power control.To maintain the system frequency and voltage magnitude around rated values,a new multi-objective optimization model for both voltage and frequency control is proposed.Moreover,a great similarity between the multiobjective optimization and game problems appears.To reduce the strong subjectivity of the traditional methods,the idea and method of the game theory are introduced into the solution.According to the present situational data and analysis of the voltage and frequency sensitivities to nodal-power variations,the design variables involved in the voltage and frequency control are classified into two strategy spaces for players using hierarchical clustering.Finally,the effectiveness and rationality of the proposed control are verified in MATLAB. 展开更多
关键词 Multi-objective optimization Voltage control Frequency control Power flow controllable loads Game theory
下载PDF
ELECTRO-HYDRAULIC COMPOUND CONTROL METHOD AND CHARACTERISTIC OF CONTROL FOR TENSION SYSTEM WITH HIGH INERTIA LOADS 被引量:2
13
作者 ZHONG Tianyu WANG Qingfeng +1 位作者 LI Yanmin GONG Fangyou 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第3期391-395,共5页
Based on the pressure regulation circuit adopting electro-hydraulic proportional relief valve to control tension, a new type of electro-hydraulic compound control circuit with throttle control unit is presented, which... Based on the pressure regulation circuit adopting electro-hydraulic proportional relief valve to control tension, a new type of electro-hydraulic compound control circuit with throttle control unit is presented, which can obtain optimal dynamic damping ratio through real-time altering pressure-flow gain of the throttle control unit, improve the dynamic characteristic of tension follow-up control for the tension system with high inertia loads. Moreover, the characteristic when the cable linear velocity variation causes change of tension is investigated, and a compound control strategy is proposed. The theoretical analysis and experimental results show that the electro-hydraulic compound control circuit is effective and the characteristic of the compound control strategy is satisfactory. 展开更多
关键词 High inertia loads Tension control system Compound control strategy
下载PDF
Design of Nichols PID Controller for Load Frequency Control 被引量:10
14
作者 KONG Fannie LI Xiaocong +1 位作者 WU Jiekang GUO Zhuangzhi 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0011-I0011,15,共1页
为解决互联水电系统负荷频率控制(load frequencycontrol,LFC)问题,及保持互联电网系统频率、联络线功率及区域控制误差(area control error,ACE)的稳定,根据闭环系统谐振峰值与系统响应最大峰值之间的关系,构建一个与系统参数及控... 为解决互联水电系统负荷频率控制(load frequencycontrol,LFC)问题,及保持互联电网系统频率、联络线功率及区域控制误差(area control error,ACE)的稳定,根据闭环系统谐振峰值与系统响应最大峰值之间的关系,构建一个与系统参数及控制器参数都相关的优化问题,通过该问题的求解获得控制器参数与系统参数之间的数学关系,针对水轮发电系统非最小相位特性,通过串加比例–微分(proportional-derivative,PD)控制方式降低系统阶次,设计尼科尔斯(Nichols)曲线的比例–积分–微分(proportional-integral-derivative,PID)控制器。基于模型参数扰动和负荷干扰的仿真结果表明:尼科尔斯PID控制器能快速调整系统频率偏差、联络线功率偏差及ACE为0,具有良好的鲁棒性能和抗负荷干扰性能,系统过渡过程性能明显优于传统PID调节器结果。 展开更多
关键词 负荷频率控制 PID控制器 设计 区域控制误差 自动控制理论 电力系统稳定 水电系统 提出问题
下载PDF
Load Frequency Control of Multi-interconnected Renewable Energy Plants Using Multi-Verse Optimizer 被引量:1
15
作者 Hegazy Rezk Mohamed A.Mohamed +1 位作者 Ahmed A.Zaki Diab N.Kanagaraj 《Computer Systems Science & Engineering》 SCIE EI 2021年第5期219-231,共13页
A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presente... A reliable approach based on a multi-verse optimization algorithm(MVO)for designing load frequency control incorporated in multi-interconnected power system comprising wind power and photovoltaic(PV)plants is presented in this paper.It has been applied for optimizing the control parameters of the load frequency controller(LFC)of the multi-source power system(MSPS).The MSPS includes thermal,gas,and hydro power plants for energy generation.Moreover,the MSPS is integrated with renewable energy sources(RES).The MVO algorithm is applied to acquire the ideal parameters of the controller for controlling a single area and a multi-area MSPS integrated with RES.HVDC link is utilized in shunt with AC multi-areas interconnection tie line.The proposed scheme has achieved robust performance against the disturbance in loading conditions,variation of system parameters,and size of step load perturbation(SLP).Meanwhile,the simulation outcomes showed a good dynamic performance of the proposed controller. 展开更多
关键词 load frequency control multi-verse optimization multi-area power system renewable energy sources
下载PDF
1.0 V low voltage CMOS mixer based on voltage control load technique 被引量:1
16
作者 韦保林 戴宇杰 +1 位作者 张小兴 吕英杰 《Journal of Central South University》 SCIE EI CAS 2011年第5期1572-1578,共7页
A CMOS active mixer based on voltage control load technique which can operate at 1.0 V supply voltage was proposed, and its operation principle, noise and linearity analysis were also presented. Contrary to the conven... A CMOS active mixer based on voltage control load technique which can operate at 1.0 V supply voltage was proposed, and its operation principle, noise and linearity analysis were also presented. Contrary to the conventional Gilbert-type mixer which is based on RF current-commutating, the load impedance in this proposed mixer is controlled by the LO signal, and it has only two stacked transistors at each branch which is suitable for low voltage applications. The mixer was designed and fabricated in 0.18 tam CMOS process for 2.4 GHz ISM band applications. With an input of 2.44 GHz RF signal and 2.442 GHz LO signal, the measurement specifications of the proposed mixer are: the conversion gain (Gc) is 5.3 dB, the input-referred third-order intercept point (PIIP3) is 4.6 dBm, the input-referred 1 dB compression point (P1dB) is --7.4 dBm, and the single-sideband noise figure (NFSSB) is 21.7 dB. 展开更多
关键词 CMOS active mixer voltage control load technique low voltage
下载PDF
H-M Bearing Capacity of A Modified Suction Caisson Determined by Using Load-/Displacement-Controlled Methods 被引量:11
17
作者 张雨坤 高玉峰 +1 位作者 李大勇 Ali H.Mahfouz 《China Ocean Engineering》 SCIE EI CSCD 2016年第6期926-941,共16页
This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were appl... This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values. 展开更多
关键词 MSC (modified suction caisson) saturated marine fine sand model tests load- and displacement-controlled loading laterally combined bearing capacity earth pressure
下载PDF
Survey of Electric Vehicle Charging Load and Dispatch Control Strategies 被引量:19
18
作者 WANG Xifan SHAO Chengcheng WANG Xiuli DU Chao 《中国电机工程学报》 EI CSCD 北大核心 2013年第1期I0001-I0024,共24页
关键词 充电控制 控制策略 电动汽车 负载调度 电力系统暂态稳定 可再生能源发电 接入电网 负荷调度
下载PDF
Resilient Fixed-Order Distributed Dynamic Output Feedback Load Frequency Control Design for Interconnected Multi-Area Power Systems 被引量:4
19
作者 Ali Azarbahram Amir Amini Mahdi Sojoodi 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第5期1139-1151,共13页
The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator cont... The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator control scheme. To this end, we consider a nonlinear interconnected model for multiarea power systems which also include uncertainties and timevarying communication delays. The design procedure is formulated using semi-definite programming and linear matrix inequality(LMI) method. The solution of the proposed LMIs returns necessary parameters for the tracking controllers such that the impact of model uncertainty and load disturbances are minimized. The proposed controllers are capable of receiving all or part of subsystems information, whereas the outputs of each controller are local. These controllers are designed such that the resilient stability of the overall closed-loop system is guaranteed. Simulation results are provided to verify the effectiveness of the proposed scheme. Simulation results quantify that the distributed(and decentralized) controlled system behaves well in presence of large parameter perturbations and random disturbances on the power system. 展开更多
关键词 Dynamic OUTPUT FEEDBACK control interconnected multi-area POWER systems load frequency control linear MATRIX INEQUALITIES POWER system control
下载PDF
Force Control Compensation Method with Variable Load Stiffness and Damping of the Hydraulic Drive Unit Force Control System 被引量:10
20
作者 KONG Xiangdong BA Kaixian +3 位作者 YU Bin CAO Yuan ZHU Qixin ZHAO Hualong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第3期454-464,共11页
Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU), and the contacting between the robot foot end and the ground is complex and variable, which increases the difficulty of force... Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU), and the contacting between the robot foot end and the ground is complex and variable, which increases the difficulty of force control inevitably. In the recent years, although many scholars researched some control methods such as disturbance rejection control, parameter self-adaptive control, impedance control and so on, to improve the force control performance of HDU, the robustness of the force control still needs improving. Therefore, how to simulate the complex and variable load characteristics of the environment structure and how to ensure HDU having excellent force control performance with the complex and variable load characteristics are key issues to be solved in this paper. The force control system mathematic model of HDU is established by the mechanism modeling method, and the theoretical models of a novel force control compensation method and a load characteristics simulation method under different environment structures are derived, considering the dynamic characteristics of the load stiffness and the load damping under different environment structures. Then, simulation effects of the variable load stiffness and load damping under the step and sinusoidal load force are analyzed experimentally on the HDU force control performance test platform, which provides the foundation for the force control compensation experiment research. In addition, the optimized PID control parameters are designed to make the HDU have better force control performance with suitable load stiffness and load damping, under which the force control compensation method is introduced, and the robustness of the force control system with several constant load characteristics and the variable load characteristics respectively are comparatively analyzed by experiment. The research results indicate that if the load characteristics are known, the force control compensation method presented in this paper has positive compensation effects on the load characteristics variation, i.e., this method decreases the effects of the load characteristics variation on the force control performance and enhances the force control system robustness with the constant PID parameters, thereby, the online PID parameters tuning control method which is complex needs not be adopted. All the above research provides theoretical and experimental foundation for the force control method of the quadruped robot joints with high robustness. 展开更多
关键词 quadruped robot force control system hydraulic drive unit force control compensation method variable load stiffness and damping simulation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部