This paper provides a new method for designing the load of transmitters switch components on provincial radar test platform. Based on the calculation of the specific parameters related to the actual charge switch comp...This paper provides a new method for designing the load of transmitters switch components on provincial radar test platform. Based on the calculation of the specific parameters related to the actual charge switch components, the load-related data model is obtained, the simulation is carried out, and the results are consistent with the actual test results. Through the theoretical numerical analysis of the load of the charging switch components of the transmitter device in the new generation of weather radar maintenance test platform, radar maintenance personnel at all levels can deepen the thorough understanding of the CINRAD/SA transmitter and have some enlightenment and improvement on the maintenance guarantee ability of the new generation of weather radar.展开更多
Analyzes the mechanism of overvoltage when contactless tap changer switch which is applied in distributing transformer converted directly.When the device convert the tap off,it employs the way that the SSR is switche...Analyzes the mechanism of overvoltage when contactless tap changer switch which is applied in distributing transformer converted directly.When the device convert the tap off,it employs the way that the SSR is switched on when voltage through zero and switched off when current through zero.But in the experiment we found that overvoltage will occur in the process of changing tap changer.The paper illustrates the mechanism of overvoltage in theory by analyzing the equivalent circuit and using analytic method of transition process.展开更多
In this paper, we focus on the estimation of time delays caused by adversaries in the sensing loop (SL). Based on the literature review, time delay switch (TDS) attacks could make any control system, in particular a p...In this paper, we focus on the estimation of time delays caused by adversaries in the sensing loop (SL). Based on the literature review, time delay switch (TDS) attacks could make any control system, in particular a power control system, unstable. Therefore, future smart grids will have to use advanced methods to provide better situational awareness of power grid states keeping smart grids reliable and safe from TDS attacks. Here, we introduce a simple method for preventing time delay switch attack on networked control systems. The method relies on an estimator that will estimate and track time delays introduced by an adversary. Knowing the maximum tolerable time delay of the plant’s optimal controller for which the plant remains stable, a time-delay detector issues an alarm signal when the estimated time delay is larger than the minimum one and directs the system to alarm state. In an alarm state, the plant operates under the control of an emergency controller that is local to the plant and remains in this mode until the networked control system state is restored. This method is an inexpensive and simple way to guarantee that an industrial control system remains stable and secure.展开更多
In this paper, a practical method to establish Doubly Fed Induction Generator (DFIG) based wind farm equivalent model for switching transient analysis is demonstrated. In order to verify this method, a 3.6MW equivalen...In this paper, a practical method to establish Doubly Fed Induction Generator (DFIG) based wind farm equivalent model for switching transient analysis is demonstrated. In order to verify this method, a 3.6MW equivalent wind farm model is built. The steady state results and load switching results are verified with those of detailed models of four 0.9MW generators. Using this method, a model of 40MW wind farm, representing the capacity for a proposed South Carolina offshore wind farm is established. To study large wind farm switching transient impacts on a system, different switching operations such as cable energizing and three phase faults at different locations in wind farm are investigated and their impact on system are analysed. Finally, conclusions based on the switching cases are presented.展开更多
A new method for multi-protocol label switching is presented in this study, whose core idea is to construct model for simulating process of accommodating network online loads and then adopt genetic algorithm to optimi...A new method for multi-protocol label switching is presented in this study, whose core idea is to construct model for simulating process of accommodating network online loads and then adopt genetic algorithm to optimize the model. Due to the heuristic property of evolutional method, the new method is efficient and effective, which is verified by the experiments.展开更多
With the increase of link rate, the arbitrator of centralized switch fabric becomes too complicated to implement. A parallel switch fabric based on crossbar, named as PSFBC (Parallel Switch Fabric Based on Crossbar), ...With the increase of link rate, the arbitrator of centralized switch fabric becomes too complicated to implement. A parallel switch fabric based on crossbar, named as PSFBC (Parallel Switch Fabric Based on Crossbar), has been proposed in this paper. PSFBC is composed of k switches whose rate is 1/k of link', these switches exchange cells in parallel; this increases the arbitrator's period and make it easy to implement. Load is evenly distributed to each switch with FCFS (First Come First Serve) rule, it can keep the order of cells in one stream. A multi-class queue scheduling policy is used in PSFBC to ensure the quality of realtime streams. Experiments show that the load on each switch in PSFBC is well balanced, its average delay of cells is little and its performance is very close to centrali{ed switch; and with the increase of number of parallel switches, the loss of PSFBC's performance keeps very small, it becomes easier to implement.展开更多
Due to the nonlinearity of the reactor power system, the load tracking situation is closely related to the initial steady-state power and the final steady-state power after the introduction of the state feedback contr...Due to the nonlinearity of the reactor power system, the load tracking situation is closely related to the initial steady-state power and the final steady-state power after the introduction of the state feedback controller. Therefore, when the initial power and the final stable power are determined, the particle swarm optimization algorithm is used to find the optimal controller parameters to minimize the load tracking error. Since there are many combinations of initial stable power and final stable power, it is not possible to find the optimal controller parameters for all combinations, so the neural network is used to take the final stable power and the initial stable power as input, and the optimal controller parameters as the output. This method obtains the optimal state feedback controller switching control method can achieve a very excellent load tracking effect in the case of continuous power change, in the power change time point, the response is fast, in the controller parameter switching time point, the actual power does not fluctuate due to the change of controller parameters. .展开更多
This paper introduces the principle of ATM switch, and discusses queueing disciplines and their performances. Authors describe the method of input queueing, output queueing, central queueing, combined input/output que...This paper introduces the principle of ATM switch, and discusses queueing disciplines and their performances. Authors describe the method of input queueing, output queueing, central queueing, combined input/output queuing, combined input/shared queueing, and multistage queueing in detail. They also present the relations between mean waiting time and input load. The queueing disciplines can be used to design the architecture of Asynchronous Transfer Mode (ATM) switch.展开更多
文摘This paper provides a new method for designing the load of transmitters switch components on provincial radar test platform. Based on the calculation of the specific parameters related to the actual charge switch components, the load-related data model is obtained, the simulation is carried out, and the results are consistent with the actual test results. Through the theoretical numerical analysis of the load of the charging switch components of the transmitter device in the new generation of weather radar maintenance test platform, radar maintenance personnel at all levels can deepen the thorough understanding of the CINRAD/SA transmitter and have some enlightenment and improvement on the maintenance guarantee ability of the new generation of weather radar.
基金Harbin science an technology officecontract num ber is 0 0 112 110 98
文摘Analyzes the mechanism of overvoltage when contactless tap changer switch which is applied in distributing transformer converted directly.When the device convert the tap off,it employs the way that the SSR is switched on when voltage through zero and switched off when current through zero.But in the experiment we found that overvoltage will occur in the process of changing tap changer.The paper illustrates the mechanism of overvoltage in theory by analyzing the equivalent circuit and using analytic method of transition process.
文摘In this paper, we focus on the estimation of time delays caused by adversaries in the sensing loop (SL). Based on the literature review, time delay switch (TDS) attacks could make any control system, in particular a power control system, unstable. Therefore, future smart grids will have to use advanced methods to provide better situational awareness of power grid states keeping smart grids reliable and safe from TDS attacks. Here, we introduce a simple method for preventing time delay switch attack on networked control systems. The method relies on an estimator that will estimate and track time delays introduced by an adversary. Knowing the maximum tolerable time delay of the plant’s optimal controller for which the plant remains stable, a time-delay detector issues an alarm signal when the estimated time delay is larger than the minimum one and directs the system to alarm state. In an alarm state, the plant operates under the control of an emergency controller that is local to the plant and remains in this mode until the networked control system state is restored. This method is an inexpensive and simple way to guarantee that an industrial control system remains stable and secure.
文摘In this paper, a practical method to establish Doubly Fed Induction Generator (DFIG) based wind farm equivalent model for switching transient analysis is demonstrated. In order to verify this method, a 3.6MW equivalent wind farm model is built. The steady state results and load switching results are verified with those of detailed models of four 0.9MW generators. Using this method, a model of 40MW wind farm, representing the capacity for a proposed South Carolina offshore wind farm is established. To study large wind farm switching transient impacts on a system, different switching operations such as cable energizing and three phase faults at different locations in wind farm are investigated and their impact on system are analysed. Finally, conclusions based on the switching cases are presented.
基金This work was supported by the National Natural Science Foundation of China (No10371097)Open Project of Com-putational Key Laboratory in Yunnan Provice
文摘A new method for multi-protocol label switching is presented in this study, whose core idea is to construct model for simulating process of accommodating network online loads and then adopt genetic algorithm to optimize the model. Due to the heuristic property of evolutional method, the new method is efficient and effective, which is verified by the experiments.
文摘With the increase of link rate, the arbitrator of centralized switch fabric becomes too complicated to implement. A parallel switch fabric based on crossbar, named as PSFBC (Parallel Switch Fabric Based on Crossbar), has been proposed in this paper. PSFBC is composed of k switches whose rate is 1/k of link', these switches exchange cells in parallel; this increases the arbitrator's period and make it easy to implement. Load is evenly distributed to each switch with FCFS (First Come First Serve) rule, it can keep the order of cells in one stream. A multi-class queue scheduling policy is used in PSFBC to ensure the quality of realtime streams. Experiments show that the load on each switch in PSFBC is well balanced, its average delay of cells is little and its performance is very close to centrali{ed switch; and with the increase of number of parallel switches, the loss of PSFBC's performance keeps very small, it becomes easier to implement.
文摘Due to the nonlinearity of the reactor power system, the load tracking situation is closely related to the initial steady-state power and the final steady-state power after the introduction of the state feedback controller. Therefore, when the initial power and the final stable power are determined, the particle swarm optimization algorithm is used to find the optimal controller parameters to minimize the load tracking error. Since there are many combinations of initial stable power and final stable power, it is not possible to find the optimal controller parameters for all combinations, so the neural network is used to take the final stable power and the initial stable power as input, and the optimal controller parameters as the output. This method obtains the optimal state feedback controller switching control method can achieve a very excellent load tracking effect in the case of continuous power change, in the power change time point, the response is fast, in the controller parameter switching time point, the actual power does not fluctuate due to the change of controller parameters. .
文摘This paper introduces the principle of ATM switch, and discusses queueing disciplines and their performances. Authors describe the method of input queueing, output queueing, central queueing, combined input/output queuing, combined input/shared queueing, and multistage queueing in detail. They also present the relations between mean waiting time and input load. The queueing disciplines can be used to design the architecture of Asynchronous Transfer Mode (ATM) switch.