Locking compression plate+T-type steel plate for postoperative weight bearing and functional recovery in complex tibial plateau fractures 被引量:6
1
作者 Hai-Feng Li Tao Yu +2 位作者 Xing-Fei Zhu Hua Wang Ying-Qi Zhang 《World Journal of Clinical Cases》 SCIE 2022年第2期502-510,共9页
Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in dif... Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications. 展开更多
关键词 locking compression plate T-type steel plate COMPLEXITY Tibial plateau fracture Functional recovery COMPLICATIONS
下载PDF
Application of proximal femur locking compression plate for unstable four part intertrochanteric fractures 被引量:2
2
作者 夏青 《外科研究与新技术》 2011年第2期108-108,共1页
Objective To evaluate the clinical results of proximal femur locking compression plate (LCP) for unstable four-part intertrochanteric femoral fractures.Methods Clinical data of53patients wiith unstable four-part inter... Objective To evaluate the clinical results of proximal femur locking compression plate (LCP) for unstable four-part intertrochanteric femoral fractures.Methods Clinical data of53patients wiith unstable four-part intertrochanteric 展开更多
关键词 Application of proximal femur locking compression plate for unstable four part intertrochanteric fractures
下载PDF
Effect of Locking Compression Plate on the Treatment of Limb Fracture and the Effect of Operative Success Rate and Postoperative Recovery Time
3
作者 Hanping Huang 《Journal of Integrative Medicine(双语)》 2020年第1期9-11,共3页
Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly... Objective:To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods:120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group(60 cases)and observation group(60 cases).The control group was treated with plate screw internal fixation,The observation group used locking compression plate internal fixation,Compare the effect of treatment,the success rate of operation and the time of postoperative recovery.results:compared the effective rate of the two groups,the observation group(93.33%)was significantly higher than the control group(75.00%).Compared with the two groups,the success rate of operation and the time of postoperative recovery,the observed composition power was higher than that of the control group,and the postoperative recovery time was lower than that of the control group,P<0.05.Conclusion:The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation,shorten the recovery time after operation,the overall curative effect is ideal,and the clinical popularization value is high. 展开更多
关键词 Limb fracture locking compression plate internal fixation Plate screw internal fixation EFFECT Surgical success rate Postoperative recovery time
下载PDF
Postoperative Fracture Healing Effects of Locking Compression Plate for the Treatment of Limb Fractures
4
作者 Bin Zhao Jingli Dou +1 位作者 Rongcai Zhang Mingming Wang 《Journal of Clinical and Nursing Research》 2021年第3期24-27,共4页
Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in ou... Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development. 展开更多
关键词 locking compression plate treatment method Simple plate and screw internal fixation treatment method Patients with limb fractures
下载PDF
Treatment of distal clavicle fracture with distal radius volar locking compression plate 被引量:1
5
《Chinese Journal of Traumatology》 CAS 2009年第5期-,共3页
Objective: To observe the early clinical outcomes of the internal fixation with distal radius volar locking compression plate (LCP) in treatment of distal clavicle fracture.Methods: Six patients with unilateral distal... Objective: To observe the early clinical outcomes of the internal fixation with distal radius volar locking compression plate (LCP) in treatment of distal clavicle fracture.Methods: Six patients with unilateral distal clavicle fractures, identified as type Ⅱ according to Neer classification system, including 4 males and 2 females, were treated with open reduction and internal fixation using a distal radius volar LCP. Bone union was evaluated by routine X-ray radiography, and shoulder joint function were assessed by Constant score system.Results: All fractures achieved bone union at 6 to 8 weeks postoperatively, and Constant scores ranged from 95 to 100 at the postoperative 10 to 12 weeks.Conclusion: Fixation of distal clavicle fracture with distal radius volar LCP demonstrates excellent effects of bone union with rarely early complications, thus providing a new technique to treat distal clavicle fracture. 展开更多
关键词 CLAVICLE Fractures bone locking compression plate
原文传递
Biomechanical Comparison of Gourd-shaped LCP versus LCP for Fixation of Comminuted Tibial Shaft Fracture 被引量:1
6
作者 徐国辉 刘勃 +5 位作者 张奇 王娟 陈伟 刘月驹 彭阿钦 张英泽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第2期250-257,共8页
The purpose of this study was to compare monotonic biomechanical properties of gourd-shaped LCP fixation with LCP fixation of human tibial shaft in gap fracture mode. Twenty paired fresh cadaveric human tibias were ra... The purpose of this study was to compare monotonic biomechanical properties of gourd-shaped LCP fixation with LCP fixation of human tibial shaft in gap fracture mode. Twenty paired fresh cadaveric human tibias were randomly divided into 4 groups (5 pairs each): (1) axial loading sin- gle cycle to failure testing, (2) torsion single cycle to failure testing, (3) 4-point bending single cycle to failure testing, and (4) dynamic 4-point bending testing. A 7-hole 4.5 mm gourd-shaped LCP was se- cured on the anteromedial surface of 1 randomly selected bone from each pair, respectively, using 6 locking screws in the 1st, 2nd, 3rd, 5th, 6th and 7th hole with the middle hole unfilled and just located at the mid-diaphysis of the tibia. A 7-hole 4.5 mm LCP was secured on the other bone with the same method. Standard AO/ASIF techniques were used. After fixation finished, a 10 mm gap in the mid-diaphysis of tibia was created, centrally located at the unfilled hole. The axial, torsional, and bending stiffness and failure strengths were calculated from the collected data in static testings and statisti- cally compared using paired Student's t-test. The 4-point bending fatigue lives of the two constructs were calculated from the dynamic testing data and also statistically compared using paired Student's t-test. Failure modes were recorded and visually analyzed. P〈0.05 was considered significant. Results showed that the axial, torsional and bending stiffness of gourd-shaped LCP construct was greater (4%, 19%, 12%, respectively, P〈0.05) than that of the LCP construct, and the axial, torsional and bending failure strengths of gourd-shaped LCP construct were stronger (10%, 46%, 29%, respectively, P〈0.05) than those of the LCP construct. Both constructs failed as a result of plate plastic torsional deformation. After axial loading and 4-point bending testings, LCP failed in term of an obvious deformation of bent apex just at the unfilled plate hole, while the gourd-shaped LCP failed in term of a deformation of bent arc between the 3rd and 5th holes, which indicated a more consistent stress distribution on gourd-shaped LCP. Fatigue life of gourd-shaped LCP construct was significantly greater than LCP construct (153 836±2 228 vs. 132 471±6 460 cycles, P〈0.01). All constructs failed as a result of fracture of the plate through the compression hole of the unfilled combination screw hole. The biomechanical testing showed that gourd-shaped LCP can provide greater stiffness and strength, and longer fatigue life than LCP. The gourd-shaped LCP may be more advantageous mechanically and may reduce the plate breakage rate clinically. 展开更多
关键词 tibial fracture BIOMECHANICS locking compression plate fatigue
下载PDF
Complex proximal femoral fracture in a young patient followed up for 3 years: A case report
7
作者 Zi-Yu Li Wen-Dan Cheng +2 位作者 Lei Qi Shui-Sheng Yu Jue-Hua Jing 《World Journal of Clinical Cases》 SCIE 2022年第1期283-288,共6页
BACKGROUND Ipsilateral femoral neck and intertrochanteric fractures in young patients are extremely rare,and there is no reference for fracture classification and treatment options.CASE SUMMARY We report a 27-year-old... BACKGROUND Ipsilateral femoral neck and intertrochanteric fractures in young patients are extremely rare,and there is no reference for fracture classification and treatment options.CASE SUMMARY We report a 27-year-old male patient who sustained ipsilateral femoral neck and intertrochanteric fractures and was treated with a proximal femoral locking compression plate(PFLCP).The literature on these fractures was also reviewed.At the last follow-up three years after surgery,the patient had no obvious pain in the hip,and the range of motion in the hip joint was slightly limited,but met the normal life and work needs.There were no complications such as necrosis of the femoral head.CONCLUSION The PFLCP can be used to treat these complex proximal femoral fractures,and selection should be based on the patient's specific fractures. 展开更多