For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention....For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.展开更多
In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The impro...In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The improved Faster-RCNN algorithm uses ResNet50 combined with FPN (Feature Pyramid Network) structure instead of the original ResNet50 as the feature extraction network, which can enhance the accuracy of the model for small-sized digit recognition;the use of ROI Align instead of ROI Pooling can eliminate the error caused by the quantization process of the ROI Pooling twice, so that the candidate region is more accurately mapped to the feature map, and the accuracy of the model is further enhanced. The experiment proves that the improved Faster-RCNN algorithm can reach 91.8% recognition accuracy on the test set of homemade dataset, which meets the accuracy requirements of automatic meter reading technology for water meter digital recognition, which is of great significance for solving the problem of automatic meter reading of mechanical water meters and promoting the intelligent development of water meters.展开更多
The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, ...The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, it would be necessary to establish a system of information management for the pipeline. The monitoring, calculating and analyzing functions of the system serve to give controlling instructions and safe operating rules to the automatic equipment and technician, making sure the resistance coefficient distribution along the pipeline is reasonable; the hydraulic state transition is smooth when operating conditions change or water supply accidents occur, avoiding the damage of water hammer. This paper covered the composition structures of the information management system of long-distance water transmission pipelines and the functions of the subsystems, and finally elaborated on the approaches and steps of building a mathematics model for the analysis of dynamic hydraulic status.展开更多
This paper presents an experimental study to investigate the effect of using the magnetic water conditioner on the properties of water. The water flows through a closed loop, while the pH, TDS, and hardness represent ...This paper presents an experimental study to investigate the effect of using the magnetic water conditioner on the properties of water. The water flows through a closed loop, while the pH, TDS, and hardness represent its properties. For magnetic water conditioner with flux density of 170 mT, results showed that pH increased by 15.65% for 820 minutes of non-stop circulation. The increase in pH is divided to 93.5% for the first 360 minutes, and 6.5% for the last 460 minutes. TDS and Hardness of water are not affected by the magnetic water conditioner. Water remembers and keeps the impact of passing through the magnetic field for several hours, and pH decreased by 0.642 in24 hours. While the results lead to introduce and create the magnetized water saturation curve and water memory meter.展开更多
Water distribution network(WDN)leakage management has received increased attention in recent years.One of the most successful leakage-control strategies is to divide the network into District Metered Areas(DMAs).As a ...Water distribution network(WDN)leakage management has received increased attention in recent years.One of the most successful leakage-control strategies is to divide the network into District Metered Areas(DMAs).As a multi-staged technique,the generation of DMAs is a difficult task in design and implementation(i.e.,clustering,sectorization,and performance evaluation).Previous studies on DMAs implementation did not consider the potential use of existing valves in achieving the objective.In this work,a methodology is proposed for detecting clusters and reducing the cost of additional valves and DMA sectorization by considering existing valves as much as possible.The procedure of DMAs identification has been divided into three stages,i.e.,a)clusters identification;b)sectorization or boundaries optimization and c)performance evaluation of the partitioned network.The proposed methodology is evaluated on a simple network and a real-world water network with the findings provided and compared to the DMAs,established for a raw water network with no existing valves.It is found that there is an adequate difference in cost of strategy implementation in both the cases for the network under consideration and the existing valve system achieved better network performance in terms of resilience index.展开更多
This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid m...This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid machining process and measurement etc. as the design and sample product trial manufacture process of water meter new products are long in product development period, and low in product development efficiency in the present time.展开更多
针对光照不均匀和水表表盘雾化的指针式水表在读数检测时出现漏检、误检等问题,提出一种基于改进YOLOv5s的指针式水表读数检测方法。首先,采用Mosaic、Mixup等数据增强方法,提高模型的泛化能力;其次,引入加权双向特征金字塔网络(bilater...针对光照不均匀和水表表盘雾化的指针式水表在读数检测时出现漏检、误检等问题,提出一种基于改进YOLOv5s的指针式水表读数检测方法。首先,采用Mosaic、Mixup等数据增强方法,提高模型的泛化能力;其次,引入加权双向特征金字塔网络(bilateral feature pyramid network, BiFPN)实现更高层次的特征融合使得水表图像的深层特征图和浅层特征图充分融合,提高网络的表达能力;然后,嵌入卷积注意力机制(convolutional block attention module, CBAM),在通道和空间双重维度上强化指针式水表子表盘示数特征;最后将完全交并比损失函数(complete intersection over union loss, CIoU-Loss)替换为SIoU_Loss(scylla intersection over union loss),提升边界框的回归精度。改进算法的mAP@0.5达到97.8%,比YOLOv5s原始网络提升了3.2%。实验结果表明:该算法能有效提高指针式水表的读数检测精度。展开更多
基金supported by the National Natural Science Foundation of China(Grants No.52179062 and 51879087).
文摘For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.
文摘In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The improved Faster-RCNN algorithm uses ResNet50 combined with FPN (Feature Pyramid Network) structure instead of the original ResNet50 as the feature extraction network, which can enhance the accuracy of the model for small-sized digit recognition;the use of ROI Align instead of ROI Pooling can eliminate the error caused by the quantization process of the ROI Pooling twice, so that the candidate region is more accurately mapped to the feature map, and the accuracy of the model is further enhanced. The experiment proves that the improved Faster-RCNN algorithm can reach 91.8% recognition accuracy on the test set of homemade dataset, which meets the accuracy requirements of automatic meter reading technology for water meter digital recognition, which is of great significance for solving the problem of automatic meter reading of mechanical water meters and promoting the intelligent development of water meters.
基金Hi-Tech Research and Development Program of China (863 Program)(2002AA601140)
文摘The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, it would be necessary to establish a system of information management for the pipeline. The monitoring, calculating and analyzing functions of the system serve to give controlling instructions and safe operating rules to the automatic equipment and technician, making sure the resistance coefficient distribution along the pipeline is reasonable; the hydraulic state transition is smooth when operating conditions change or water supply accidents occur, avoiding the damage of water hammer. This paper covered the composition structures of the information management system of long-distance water transmission pipelines and the functions of the subsystems, and finally elaborated on the approaches and steps of building a mathematics model for the analysis of dynamic hydraulic status.
文摘This paper presents an experimental study to investigate the effect of using the magnetic water conditioner on the properties of water. The water flows through a closed loop, while the pH, TDS, and hardness represent its properties. For magnetic water conditioner with flux density of 170 mT, results showed that pH increased by 15.65% for 820 minutes of non-stop circulation. The increase in pH is divided to 93.5% for the first 360 minutes, and 6.5% for the last 460 minutes. TDS and Hardness of water are not affected by the magnetic water conditioner. Water remembers and keeps the impact of passing through the magnetic field for several hours, and pH decreased by 0.642 in24 hours. While the results lead to introduce and create the magnetized water saturation curve and water memory meter.
文摘Water distribution network(WDN)leakage management has received increased attention in recent years.One of the most successful leakage-control strategies is to divide the network into District Metered Areas(DMAs).As a multi-staged technique,the generation of DMAs is a difficult task in design and implementation(i.e.,clustering,sectorization,and performance evaluation).Previous studies on DMAs implementation did not consider the potential use of existing valves in achieving the objective.In this work,a methodology is proposed for detecting clusters and reducing the cost of additional valves and DMA sectorization by considering existing valves as much as possible.The procedure of DMAs identification has been divided into three stages,i.e.,a)clusters identification;b)sectorization or boundaries optimization and c)performance evaluation of the partitioned network.The proposed methodology is evaluated on a simple network and a real-world water network with the findings provided and compared to the DMAs,established for a raw water network with no existing valves.It is found that there is an adequate difference in cost of strategy implementation in both the cases for the network under consideration and the existing valve system achieved better network performance in terms of resilience index.
文摘This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid machining process and measurement etc. as the design and sample product trial manufacture process of water meter new products are long in product development period, and low in product development efficiency in the present time.
文摘针对光照不均匀和水表表盘雾化的指针式水表在读数检测时出现漏检、误检等问题,提出一种基于改进YOLOv5s的指针式水表读数检测方法。首先,采用Mosaic、Mixup等数据增强方法,提高模型的泛化能力;其次,引入加权双向特征金字塔网络(bilateral feature pyramid network, BiFPN)实现更高层次的特征融合使得水表图像的深层特征图和浅层特征图充分融合,提高网络的表达能力;然后,嵌入卷积注意力机制(convolutional block attention module, CBAM),在通道和空间双重维度上强化指针式水表子表盘示数特征;最后将完全交并比损失函数(complete intersection over union loss, CIoU-Loss)替换为SIoU_Loss(scylla intersection over union loss),提升边界框的回归精度。改进算法的mAP@0.5达到97.8%,比YOLOv5s原始网络提升了3.2%。实验结果表明:该算法能有效提高指针式水表的读数检测精度。