期刊文献+
共找到461篇文章
< 1 2 24 >
每页显示 20 50 100
Establishment of a Loop-mediated Isothermal Amplification Method for Rice Bacterial Leaf Brown Spot Disease
1
作者 Zhang Jun-hua Wang Liang +8 位作者 Zhang Yao Ni Zhe Xu Xiao-feng Yang Ming-xiu Peng Li-li Yang Xin Wang Yi-han Jiang Xiao-jiao Haseeb Younis 《Journal of Northeast Agricultural University(English Edition)》 CAS 2023年第1期13-19,共7页
Rice bacterial leaf brown spot disease caused by Pseudomonas syringae pv.syringae(Pss)is a major disease on rice.In recent years,Pss has emerged worldwide,seriously affecting rice production.It is very important to es... Rice bacterial leaf brown spot disease caused by Pseudomonas syringae pv.syringae(Pss)is a major disease on rice.In recent years,Pss has emerged worldwide,seriously affecting rice production.It is very important to establish a rapid detection method of Pss for the diagnosis and prevention of this disease.In order to robust and accurately diagnose the rice bacterial leaf brown spot disease in the field and laboratory,an assay system for the Pss was developed in this study,and the specific sequence of hrcN was used as the target,based on loop-mediated isothermal amplification(LAMP).The best detection system was MgSO 48 mmol·L^(-1),Bst DNA polymerase 8 U,dNTP 1.4 mmol·L^(-1),the ratio of internal and outer primers was 2:1,the reaction temperature was 63℃,the reaction time was 45 min,and the lowest sensitivity was 104 CFU·mL^(-1).This results provided an accurate and robust method for laboratory and field diagnosis of bacterial leaf brown spot disease of rice. 展开更多
关键词 Pseudomonas syringae pv.syringae loop-mediated isothermal amplification a rapid detection method
下载PDF
Development and Evaluation of a Loop-mediated Isothermal Amplification(LAMP) Assay for Rapid Detection of Chinese Giant Salamander Ranavirus 被引量:3
2
作者 Yi GENG Xingxing LIU +5 位作者 Yan ZHOU Kaiyu WANG Xi PENG Zhijun ZHONG Xiaoli HUANG Defang CHEN 《Asian Herpetological Research》 SCIE CSCD 2015年第1期59-65,共7页
Loop-mediated isothermal ampliifcation (LAMP) is a novel nucleic acid diagnostic method that can amplify rapidly a target template under isothermal conditions. In this study, a LAMP assay for rapid detection of Chin... Loop-mediated isothermal ampliifcation (LAMP) is a novel nucleic acid diagnostic method that can amplify rapidly a target template under isothermal conditions. In this study, a LAMP assay for rapid detection of Chinese giant salamander ranavirus(CGSRV) was developed from culture isolates and clinical samples. The LAMP assay was developed by designing one set of four speciifc primers, targeting the major capsid protein (MCP) gene of CGSRV. Reaction time and temperature were optimal for 40 min at 62°C. The developed LAMP assay is speciifc and highly sensitive for CGSRV detection, the detection limit could reach about 5 copies of cloned viral genomic fragments. The sensitivity of the LAMP assay was about 1000 and 10-fold higher than that of both conventional and nested PCR, respectively. The LAMP ampliifcation produces a typical ladder-like pattern of products on an agarose gel that can be visually inspected after addition of ethidium bromide. The LAMP assay was evaluated further with clinical samples, and the results indicated the suitability and simplicity of the test as a rapid diagnostic tool for the detection of CGSRV. 展开更多
关键词 CGSRV loop-mediated isothermal ampliifcation (lamp RANAVIRUS Chinese giant salamander
下载PDF
The Development of a Loop-Mediated Isothermal Amplification (LAMP) Procedure for Plague Diagnostic 被引量:1
3
作者 Mariana de Lira Nunes Carina Lucena Mendes-Marques +1 位作者 Alzira Maria Paiva de Almeida Nilma Cintra Leal 《American Journal of Analytical Chemistry》 2014年第16期1069-1077,共9页
Plague caused by Yersinia pestis is one of the infectious diseases subject to the International Health Regulations (IHR). Permanent monitoring of the focal plague areas is mandatory in order to enable prompt control m... Plague caused by Yersinia pestis is one of the infectious diseases subject to the International Health Regulations (IHR). Permanent monitoring of the focal plague areas is mandatory in order to enable prompt control measures to prevent the spread of the disease. Therefore, the availability of efficient diagnosis tests is of paramount importance. Here, we describe a loop-mediated isothermal amplification (LAMP)-based procedure for rapid Y. pestis detection. We constructed a set of LAMP primers, which were used in assays to establish the reaction conditions that would lead to the quick visualization of the results by evaluating the test tube with the naked eye. The primers were specifically designed to target the caf1 gene located on pFra/Tox (pMT), a prototypical plasmid of Y. pestis. The LAMP procedure was performed at 65&deg;C for 45 min in a water bath and allowed for the detection of at least 10 pg of bacterial DNA. Due to its simplicity, specificity, sensitivity and rapidity, the LAMP technique is an additional tool that may be implemented in routine plague diagnoses, especially in emergencies. 展开更多
关键词 PLAGUE YERSINIA PESTIS Diagnosis Tests loop-mediated isothermal amplification (lamp)
下载PDF
Efficient detection of pathogen virus in sand dabs,Paralichthys olivaceus using loop-mediated isothermal amplification(LAMP) 被引量:1
4
作者 HWANG Jinik PARK So Yun +3 位作者 SUH Sung-Suk PARK Mirye LEE Sukchan LEE Taek-Kyun 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2016年第8期44-50,共7页
Viral hemorrhagic septicemia virus(VHSV) and marine birnavirus(MABV) are the causative pathogens for some of the most explosive epidemics of emerging viral diseases in many Asian countries, leading to huge economi... Viral hemorrhagic septicemia virus(VHSV) and marine birnavirus(MABV) are the causative pathogens for some of the most explosive epidemics of emerging viral diseases in many Asian countries, leading to huge economic losses in aquaculture. Rapid molecular detection for surveillance or diagnosis has been a critical component in reducing the prevalence of pathogen infection. The loop-mediated isothermal amplification(LAMP) of DNA is currently one of the most commonly used molecular diagnostic tools, as it is simple, quick, and easy to amplify target DNA under isothermal conditions. In the present study, a novel and highly specific LAMP assay for the sensitive and rapid detection of VHSV and MABV infection in fish was developed. Using a set of synthesized primers matching a specific region of the genome, the efficiency and specificity of the LAMP assay were optimized in terms of the reaction temperature and DNA polymerase concentration, as they are the main determinants of the sensitivity and specificity of the LAMP assay. In particular, we demonstrated that our assay could be applied to efficient detection of VHSV and MABV infection in the wild fish, Paralichthys olivaceus. Our results demonstrate the simplicity and convenience of this method for the detection of viral infection in aquatic organisms. 展开更多
关键词 viral hemorrhagic septicaemia virus(VHSV) marine birnavirus(MABV) polymerase chain reaction loop-mediated isothermal amplification
下载PDF
Preliminary investigation and detection based on loop-mediated isothermal amplification(LAMP)of phytoplasmas associated with diseases in B.napus L.
5
作者 Yancheng Wen Shufen Zhang +8 位作者 Junping He Dongfang Cai Jiacheng Zhu Jianping Wang Jinhua Cao Kun Hu Lei Zhao Dongguo Wang Yizi Liu 《Oil Crop Science》 CSCD 2022年第4期219-224,共6页
In the last decade,some disease occurred on our experimental farms that had caused serious losses.They were not caused by fungi,bacteria or viruses.By loop-mediated isothermal amplification(LAMP)technique,the detectio... In the last decade,some disease occurred on our experimental farms that had caused serious losses.They were not caused by fungi,bacteria or viruses.By loop-mediated isothermal amplification(LAMP)technique,the detection results pointed to the possible pathogen as phytoplasma.The investigation results implied that phytoplasmas could cause more than 13 kinds of symptoms in almost all parts of plants in B.napus L.,including witches’broom,multi-stems,aggregate main inflorescences,and flat stems.The incidences of these phytoplasma-associated diseases in our experimental farms rose from 1.61%in 2010 to 6.00%in 2021.Some phytoplasma infected plants died without any growing points.These studies would be helpful for detecting phytoplasmas diseases,selecting disease resistant germplasm and improving varieties with disease resistances in B.napus L. 展开更多
关键词 B.napus L. Phytoplasma associated disease PATHOGEN DETECTION loop-mediated isothermal amplification (lamp)
下载PDF
One New Method of Nucleic Acid Amplification-Loop-mediated Isothermal Amplification of DNA 被引量:9
6
作者 Xue-en FANG Jian LI Qin CHEN 《Virologica Sinica》 SCIE CAS CSCD 2008年第3期167-172,共6页
Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method, which amplifies DNA with high specificity, sensitivity, rapidity and efficiency under isothermal conditions using a set of fo... Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method, which amplifies DNA with high specificity, sensitivity, rapidity and efficiency under isothermal conditions using a set of four specially designed primers and a Bst DNA polymerase with strand displacement activity. The basic principle, characteristics, development of LAMP and its applications are summarized in this article. 展开更多
关键词 DNA 脱氧核糖核算 环介导等温扩增 基因 检测技术
下载PDF
Sensitive and rapid detection of two toxic microalgae Alexandrium by loop-mediated isothermal amplification 被引量:1
7
作者 ZHANG Fengying SHI Yanhong +2 位作者 JIANG Keji XU Zhaoli MA Lingbo 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2012年第2期139-146,共8页
A loop-mediated isothermal amplification (LAMP) assay was designed and evaluated for rapid de- tection of the toxic microalgae Alexandrium catenella and A. minutum, which can produce paralytic shellfish poisoning (... A loop-mediated isothermal amplification (LAMP) assay was designed and evaluated for rapid de- tection of the toxic microalgae Alexandrium catenella and A. minutum, which can produce paralytic shellfish poisoning (PSP). Two sets of four specific primers targeting these two species were derived from the sequence of internal transcribed spacer (ITS) of ribosomal DNA. The method worked well in less than an hour under isothermal conditions of 65℃. LAMP specificity was validated in closely related algae as a comparison, suggesting the strict specificity of the LAMP primers. Two visual inspection approaches were feasible to interpret the positive or negative results. The detection lim- its of A. catenella and A. minutum samples using the LAMP assay were found to be 5.6 and 4.5 pg DNA, respectively. The sensitivity of this LAMP assay was 10 or 100-fold higher than Polymerase Chain Reaction (PCR) method in detecting the two microalgae. These characteristics of species specificity, sensitivity, and rapidity suggest that this method has the potentiality in the monitoring of red tide caused by A. catenella and A. minutum. 展开更多
关键词 Alexandrium eatenella Alexandrium minutum detection loop-mediated isothermal amplification (lamp ribosomal DNA internal transcribed spacer (ITS)
下载PDF
Development and Evaluation of a Loop-mediated Isothermal Amplification Assay for the Rapid Detection and Identification of Pectobacterium carotovorum on Celery in the Field 被引量:3
8
作者 Yanxia Shi Zhiwen Jin +4 位作者 Xianglong Meng Lixue Wang Xuewen Xie Ali Chai Baoju Li 《Horticultural Plant Journal》 SCIE 2020年第5期313-320,共8页
Pectobacterium carotovorum is the causal agent of bacterial soft rot in a wide range of vegetable host species.Once P.carotovorum infects the plant,the spread of the disease is difficult to control.In this study,a rap... Pectobacterium carotovorum is the causal agent of bacterial soft rot in a wide range of vegetable host species.Once P.carotovorum infects the plant,the spread of the disease is difficult to control.In this study,a rapid and sensitive method based on loop-mediated isothermal amplification(LAMP)was developed for detecting P.carotovorum in celery with soft rot using a primer set designed from the pmrA conserved sequence of P.carotovorum.The specificity of the LAMP primer set for P.carotovorum was extensively validated on both P.carotovorum strains and nontarget strains.The sensitivity was 1 pg of P.carotovorum genomic DNA,which demonstrated 10 times more sensitive than the conventional PCR assay.LAMP was also used to detect P.carotovorum in bacterial suspension.The lowest detection concentration was 104 CFU·mL^−1.In addition,a LAMP assay,in conjunction with a crude DNA extraction method,was successfully performed on P.carotovorum-infected samples derived from both artificially and naturally infected plants.In summary,the LAMP assay established in this study constitutes a simple,sensitive,and rapid method for the detection of P.carotovorum,and has potential application in the control of celery soft rot disease through early detection. 展开更多
关键词 Bacterial soft rot P.carotovorum loop-mediated isothermal amplification(lamp) CELERY pmrA gene field detection
下载PDF
Development of loop-mediated isothermal amplification for rapid detection of Entamoeba histolytica 被引量:2
9
作者 Windell L.Rivera Vanissa A.Ong 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第6期457-461,共5页
Objective:To develop a loop-mediated isothermal amplification(LAMP) assay for the detection of Entamoeba histolytica(E.histolytica),the causative agent of amebiasis.Methods:The LAMP primer set was designed from E.hist... Objective:To develop a loop-mediated isothermal amplification(LAMP) assay for the detection of Entamoeba histolytica(E.histolytica),the causative agent of amebiasis.Methods:The LAMP primer set was designed from E.histolytica hemolysin gene HLY6.Genomic DNA of E.histolytica trophozoites strain HK9 was used to optimize the LAMP mixture and conditions.Amplification of DNA in the LAMP mixture was monitored through visual inspection for turbidity of the LAMP mix as well as addition of fluorescent dye.Results:Positive LAMP reactions turned turbid while negative ones remained clear.Upon addition of a fluorescent dye,all positive reactions turned green while the negative control remained orange under ambient light After elecrophoresis in 1.5% agarose gels,a ladder of multiple bands of different sizes can be oliserved in positive samples while no bands were detected in the negative control.The sensitivity of the assay was found to be S parasites per reaction which corresponds to approximately 1S.8 ng/μL DNA.The specificity of the assay was verified by the absence of amplified products when DNA from other gastrointestinal parasites such as the morphologically similar but non-pathogenic species,Entamoeba dispar. and other diarrhea-causing organisms such as Blastocystis hominis and Escherichia coli were used.Conclusions:The I.AMP assay we have developed enables the detection of E.histolytica with rapidity and ease,therefore rendering it is suitable for laboratory and field diagnosis of amebiasis. 展开更多
关键词 AMEBIASIS Diagnosis DNA ENTAMOEBA HISTOLYTICA HEMOLYSIN gene loop-mediated isothermal amplification assay
下载PDF
Evaluation of Reverse Transcription Loop-Mediated Isothermal Amplification assays for Rapid Detection of Human Enterovirus 71 and Coxsackievirus A16 in Clinical Samples 被引量:5
10
作者 Hong Zhang Kai Nie +8 位作者 Yunzhi Liu Le Luo Wei Huang Shuaifeng Zhou Mengjie Yang Yu Chen Jianmin Luo Lidong Gao Xuejun Ma 《Advances in Infectious Diseases》 2012年第4期110-118,共9页
A sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for human enterovirus 71 (EV71) and Coxsackievirus A16 (CVA16) infection was further evaluated. The one step reaction was perfor... A sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for human enterovirus 71 (EV71) and Coxsackievirus A16 (CVA16) infection was further evaluated. The one step reaction was performed in a single tube at 65?C for 45 min for EV71 and 35 min for CVA16. The detection limits of RT-LAMP assays for both EV71 and CVA16 were 0.1 of a 50% tissue culture infective dose (TCID50) per reaction, based on 10—Fold dilutions of a titrated EV71 or CVA16 strain. The specific assay showed there were no cross-reactions with Coxsackievirus A (CVA) viruses (CVA 2, 4, 5, 7, 9, 10, 14, and 25), Coxsackievirus B (CVB) viruses (CVB 1, 2, 3, 4, and 5) or ECHO viruses (ECHO 3, 6, 11, and 19). In parallel with commercial quantitative real-time polymerase chain reaction (qRT-PCR) diagnostic kits for EV71 and CVA16, the RT-LAMP assay was evaluated with 515 clinical specimens, the results showed the RT-LAMP assay and the qRT-PCR assay were in complete agreement for 513/515 (99.6%) of the specimens. Two samples with discrepant results from two methods were further verified by nested reverse transcription polymerase chain reaction (nRT-PCR) assay and sequencing to be true positives for CVA16. In conclusion, RT-LAMP assay is demonstrated to be a sensitive and specific assay and have a great potential for the rapid and visual screening of EV71 and CVA16 in China, especially in those resource-limited hospitals and rural clinics of provincial and municipal regions. 展开更多
关键词 Human ENTEROVIRUS 71 Coxsackievirus A16 REVERSE TRANSCRIPTION loop-mediated isothermal amplification
下载PDF
Rapid and Sensitive Detection of PRRSV by a Reverse Transcription-Loop-mediated Isothermal Amplification Assay 被引量:7
11
作者 Lei Zhang Ye-bing Liu +2 位作者 Lei Chen Jian-huan Wang Yi-bao Ning 《Virologica Sinica》 SCIE CAS CSCD 2011年第4期252-259,共8页
A real-time monitoring reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the sensitive and specific detection of prototypic,prevalent North American porcine reproductive an... A real-time monitoring reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the sensitive and specific detection of prototypic,prevalent North American porcine reproductive and respiratory syndrome virus (PRRSV) strains.As a higher sensitivity and specificity method than reverse transcription polymerase chain reaction (RT-PCR),the RT-LAMP method only used a turbidimeter,exhibited a detection limit corresponding to a 10-4 dilution of template RNA extracted from 250 μL of 105 of the 50% tissue culture infective dose (TCID50) of PRRSV-containing cells,and no cross-reactivity was observed with other related viruses including porcine circovirus type 2,swine influenza virus,porcine rotavirus and classical swine fever virus.From forty-two field samples,33 samples in the RT-LAMP assay was detected positive,whereas three of which were not detected by RT-PCR.Furthermore,in 33 strains of PRRSV,an identical detection rate was observed with the RT-LAMP assay to what were isolated using porcine alveolar macrophages.These findings demonstrated that the RT-LAMP assay has potential clinical applications for the detection of highly pathogenic PRRSV isolates,especially in developing countries. 展开更多
关键词 逆转录聚合酶链反应 特异性检测 PRRSV 灵敏度 等温 介导 呼吸综合征病毒 肺泡巨噬细胞
下载PDF
Detection of Staphylococcus aureus in Dairy Food by Loop-mediated Isothermal Amplification 被引量:2
12
作者 Cheng Xiao Wang Yongxin +4 位作者 An Hong Liu Juanjuan Zhang Bo Jia Zhen Cheng Jian 《Animal Husbandry and Feed Science》 CAS 2014年第3期127-130,共4页
[ Objective ] This study was to investigate the creditability of applying loop-mediated isothermal amplification method (LAMP) to detect Staphylococcus aureus in dairy products. [ Methods] The primers for heat resis... [ Objective ] This study was to investigate the creditability of applying loop-mediated isothermal amplification method (LAMP) to detect Staphylococcus aureus in dairy products. [ Methods] The primers for heat resistant nuclease gene (nuc) of Staphylococcus aureus were designed for establishing the LAMP method for rapidly detecting Staphylococcus aureus. [ Results ] The results of LAMP detection on Staphylococcus aureus in various dairy products were completely identical with that by bacterial isolation test; meanwhile it has a high specificity and a 10-fold sensitivity over the hemi-nested PCR. [ Conclusion] LAMP can be used for the detection of Staphylococcus aureus in dairy products. 展开更多
关键词 Staphylococcus aureus Nuc gene loop-mediated isothermal amplification
下载PDF
Rapid,sensitive detection of Vibrio anguillarum using loop-mediated isothermal amplification 被引量:2
13
作者 高宏伟 李富花 +2 位作者 张晓军 王兵 相建海 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2010年第1期62-66,共5页
Vibrio anguillarum is an important bacterial pathogen of aquatic organisms and a significant problem in aquatic farming.The rapid detection and identification of V.anguillarum,and other pathogens that infect marine or... Vibrio anguillarum is an important bacterial pathogen of aquatic organisms and a significant problem in aquatic farming.The rapid detection and identification of V.anguillarum,and other pathogens that infect marine organisms,is crucial to effective disease management.In this study,we developed a loop-mediated amplification (LAMP) assay to detect V.anguillarum in an hour in a single tube without the need for thermal cycling.Conserved regions of the metalloproteinase (empA) gene of V.anguillarum served as the targets for primer design.A fragment of the empA gene was amplified at 65°C in the presence of the primer mixture and Bst DNA polymerase.In the optimized LAMP assay,6.7 pg of V.anguillarum DNA could be detected.Six strains of V.anguillarum and 17 strains of non-V.anguillarum bacteria were used in this study to evaluate the species specificity of the primers.The six V.anguillarum strains gave a positive result in the LAMP assay.This method was also validated in V.anguillarum-infected fish.This LAMP method is more sensitive than PCR in the detection of V.anguillarum and shows good species specificity.The LAMP assay is therefore an effective method for the quick detection of V.anguillarum both in the laboratory and in the field. 展开更多
关键词 快速检测 鳗弧菌 热循环 介导 DNA聚合酶 特异性引物 lamp 灵敏
下载PDF
Rapid,specific and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification targeted to vvhA gene 被引量:1
14
作者 ZHANG Lina WANG Mingyi +5 位作者 CONG Dianxia DING Shuyan CONG Rinan YUE Jinyong GENG Jianli HU Chengjin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2018年第4期83-88,共6页
Vibrio vulnificus is an estuarine bacterial pathogen for human.The rapid,specific and sensitive detection of V.vulnificus is urgently needed for early disease diagnosis and timely treatment of V.vulnificus infection.I... Vibrio vulnificus is an estuarine bacterial pathogen for human.The rapid,specific and sensitive detection of V.vulnificus is urgently needed for early disease diagnosis and timely treatment of V.vulnificus infection.In the study,a loop-mediated isothermal amplification(LAMP) technique was developed for V.vulnificus detection with a set of primers,composed of two out primers and two inner primers targeted to vvh A gene.The optimal amplification temperature was 63°C and the reaction only took 35 min.The amplification products could not only be detected by agarose gel electrophoresis with ladder-like pattern bands,but also could be visualized using calcein with naked eye directly.Forty-five strains were tested for the specificity of LAMP assay,and all the V.vulnificus strains were identified correctly while other strains were negative results.The sensitive of the new LAMP assay was 100-fold more sensitive than the conventional PCR.Meanwhile,all the V.vulnificus strains were detected correctly in spiked,clinical and environmental samples by the new LAMP assay.Compared with other well-known techniques,the new LAMP assay targeted to vvh A gene was extremely rapid,simple,sensitive and specific for V.vulnificus identification. 展开更多
关键词 Vibrio uulnificus loop-mediated isothermal amplification vvhA gene
下载PDF
Development of a Loop-Mediated Isothermal Amplification Assay for Porcine Circovirus Type 2 被引量:2
15
作者 Ye-bing Liu Lei Zhang +2 位作者 Qin-hong Xue Yi-bao Ning Zhi-gang Zhang 《Virologica Sinica》 SCIE CAS CSCD 2011年第3期214-220,共7页
In this study, the loop-mediated isothermal amplification (LAMP) method was used to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). According to the PCV2 sequences published in GenBan... In this study, the loop-mediated isothermal amplification (LAMP) method was used to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). According to the PCV2 sequences published in GenBank, multiple LAMP primers were designed targeting conserved sequences of PCV2. Using the DNA extracted from PCV2 isolates HUN-09 and SD-09 as the template, LAMP reactions in a PCV2 LAMP system was performed, the amplification products were detected by adding SYBR Green I and could be observed directly by the naked eye. The results showed highly-efficient and specific amplification in 30 min at 63°C with a LAMP real-time turbidimeter. Furthermore, PCV2 DNA templates, with a detection limit of 5.5×10-5 ng of nucleic acid, indicated that this assay was highly sensitive. The results obtained with the naked eye after SYBR Green I staining were consistent with those detected by the real-time turbidimeter, showing the potential simplicity of interpretation of the assay results. The LAMP assay appeared to have greater accuracy than PCR and virus isolation for the analysis of 18 clinical samples. In addition it offers higher specificity and sensitivity, shorter reaction times and simpler procedures than the currently available methods of PCV2 detection. It is therefore a promising tool for the effective and efficient detection of PCV2. 展开更多
关键词 猪圆环病毒2型 实验 等温 介导 DNA模板 PCV2 GENBANK 检测系统
下载PDF
Combination of Loop-Mediated Isothermal Amplification Assay and Nested PCR for Detection of Borrelia burgdorferi sensu lato in Human Serum Samples 被引量:1
16
作者 ZHANG Liu Li HOU Xue Xia +3 位作者 GENG Zhen LOU Yong Liang WAN Kang Lin HAO Qin 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2015年第4期312-315,共4页
A set of universal loop-mediated isothermal amplification (LAMP) primers targeting the flo gene was designed to detect Borrelia burgdorferi sensu lato (B. burgdorferi s.I.) in human samples. The sensitivity of LAM... A set of universal loop-mediated isothermal amplification (LAMP) primers targeting the flo gene was designed to detect Borrelia burgdorferi sensu lato (B. burgdorferi s.I.) in human samples. The sensitivity of LAMP was 20 copies/reaction, and the assay did not detect false positives among 11 other related bacteria. A positive LAMP result was obtained for 9 of the 24 confirmed cases and for 12 of 94 suspected cases. The positive rate of LAMP was the same as that of nested PCR. The LAMP is a useful diagnostic method that can be developed for rapid detection of B. burgdorferi s.I. in human sera. Combination of the LAMP and nested PCR was more sensitive for detecting B. burgdorferi s.I. in human serum samples. 展开更多
关键词 PCR lamp Combination of loop-mediated isothermal amplification Assay and Nested PCR for Detection of Borrelia burgdorferi sensu lato in Human Serum Samples
下载PDF
Development of an in situ loop-mediated isothermal amplification technique for chromosomal localization of DNA sequences 被引量:1
17
作者 孟庆磊 王师 +2 位作者 张玲玲 黄晓婷 包振民 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2013年第1期128-133,共6页
In situ loop-mediated isothermal amplification (in situ LAMP) combines in situ hybridization and loop-mediated isothermal amplification (LAMP) techniques for chromosomal localization of DNA sequences. In situ LAMP is ... In situ loop-mediated isothermal amplification (in situ LAMP) combines in situ hybridization and loop-mediated isothermal amplification (LAMP) techniques for chromosomal localization of DNA sequences. In situ LAMP is a method that is generally more specific and sensitive than conventional techniques such as fluorescence in situ hybridization (FISH), primed in situ labeling (PRINS), and cycling primed in situ labeling (C-PRINS). Here, we describe the development and application of in situ LAMP to identify the chromosomal localization of DNA sequences. To benchmark this technique, we successfully applied this technique to localize the major ribosomal RNA gene on the chromosomes of the Zhikong scallop (Chlamys farreri). 展开更多
关键词 荧光原位杂交 染色体定位 DNA序列 扩增技术 等温 介导 引物原位标记 lamp
下载PDF
Rapid detection of Shigella and Salmonella in rhesus monkeys by loop-mediated isothermal amplification assay 被引量:1
18
作者 叶莉 吴芳 +6 位作者 WANG Yi-jia ZHENG Jun-wen FAN Jun-wen DING Ming SHI Yan-sheng 张小飞 白杰英 《中国实验动物学报》 CAS CSCD 北大核心 2016年第1期7-13,共7页
Objective To establish a loop-mediated isothermal amplification( LAMP) method for detecting diarrhea pathogens( Shigella and Salmonella) in rhesus monkeys and evaluate the application of the LAMP method for detecting ... Objective To establish a loop-mediated isothermal amplification( LAMP) method for detecting diarrhea pathogens( Shigella and Salmonella) in rhesus monkeys and evaluate the application of the LAMP method for detecting bacterial diseases in nonhuman primate laboratory animals. Materials and Methods A total of 205 fecal samples of rhesus monkeys were detected in this LAMP assay. The specificity and sensitivity of LAMP for Shigella and Salmonella were analyzed,and real-time polymerase chain reaction( REAL-TIME PCR) assay was employed as control. Results The LAMP method established here needed only 45 min to complete the reaction at 63℃. Its detection limit was 10 pg / μL and with a high specificity. The positive rate of Shigella and Salmonella was 1. 5% and 6. 3%,respectively. Conclusions Here we have established a fast and simple Shigella and Salmonella LAMP detection method that has strong specificity and high sensitivity and is suitable for rapid detection of bacterial disease in macaques. The development of this rapid detection kit is underway,and it will be helpful to the diarrhea detection. 展开更多
关键词 经典条件反射 操作式条件反射 SD大鼠 WISTAR大鼠 学习记忆
下载PDF
Ultrathin metal-organic framework nanosheets (Cu-TCPP)-based isothermal nucleic acid amplification for food allergen detection 被引量:1
19
作者 Jiale Gao Xiaodong Sun +3 位作者 Yongxin Liu Bing Niu Qin Chen Xueen Fang 《Food Science and Human Wellness》 SCIE CSCD 2023年第5期1788-1798,共11页
The rapid and accurate detection of peanuts and soybeans allergen is important to the food safety. In this study, Cu-TCPP nanosheet, a kind of ultra-thin metal-organic framework(MOF)was synthesized and applied in loop... The rapid and accurate detection of peanuts and soybeans allergen is important to the food safety. In this study, Cu-TCPP nanosheet, a kind of ultra-thin metal-organic framework(MOF)was synthesized and applied in loop-mediated isothermal amplification(named Cu-TCPP@LAMP), which can inhibit the non-specific amplification by absorbing and precise temperature releasing of single primer. As thus, Cu-TCPP@LAMP can achieve high sensitivity and specific amplification of the target gene. As a result, peanut and soybean allergens genes contained in food were successfully detected with a favorable detection sensitivity(5 ng/μL for peanuts and 10 ng/μL for soybeans)and reliable repeatability(The coefficient of variation was 3.38% for peanuts and 3.33% for soybeans). Moreover, the established method was utilized for detection of several commercial products, and had a high consistency with the standard method. Apart from food allergens, this novel assay can be widely used in other areas, such as pathogen detection, tumor nucleic acid detection and so on. 展开更多
关键词 Cu-TCPP nanosheet Plant allergen Nucleic acid detection loop-mediated isothermal amplification
下载PDF
Detection of Target Genes in Viable Bacteria and Extracellular DNA Using Loop-Mediated Isothermal Amplification Assay
20
作者 YANG Qianqian ZHANG Xuzhi +5 位作者 JIANG Xiaoyu LI Yang ZHAO Jun HAO Zhihui WANG Pingping QU Keming 《渔业科学进展》 CSCD 北大核心 2020年第2期41-50,共10页
When the loop-mediated isothermal amplification(LAMP)assay is used for detecting target genes,DNA extraction is unnecessary in many cases.Simple pretreatment(e.g.heating)is enough to obtain rather sensitive responses.... When the loop-mediated isothermal amplification(LAMP)assay is used for detecting target genes,DNA extraction is unnecessary in many cases.Simple pretreatment(e.g.heating)is enough to obtain rather sensitive responses.Even test samples without any pretreatment can be used as template.This feature suggests that LAMP is superior to PCR in developing point-of-care test strategies.In this study,using Stx1 gene from E.coli as model,we verified that viable cells,dead cells and extracellular DNA could function as template in the LAMP assay.In the incubation at 63℃,viable bacteria in the LAMP reaction mixture lysed completely within 2 min,providing DNA template for nucleic acid amplification.The Stx1 gene in diluted culture medium,spiked tap water,spiked seawater and real seawater all could be detected,with or without the step of DNA extraction.We found that the complex substances in real sample(e.g.natural seawater)exhibited considerable inhibitory effect on the sensitivity of the LAMP assay.These outcomes are meaningful for building a point-of-care strategy by employing the LAMP assay for environmental monitoring,bio-resource surveys,food safety,etc.in particular those based on environmental DNA. 展开更多
关键词 loop-mediated isothermal amplification DNA extraction-free Direct gene detection Viable cell Extracellular DNA
下载PDF
上一页 1 2 24 下一页 到第
使用帮助 返回顶部