The diagnosis of non-alcoholic fatty liver disease(NAFLD)and metabolic dysfunction-associated fatty liver disease only on the basis of laboratory parameter score such as Hepatic Steatosis Index which includes liver en...The diagnosis of non-alcoholic fatty liver disease(NAFLD)and metabolic dysfunction-associated fatty liver disease only on the basis of laboratory parameter score such as Hepatic Steatosis Index which includes liver enzymes,gender,basal metabolic index,and presence of diabetic mellitus is not sufficient to exclude other causes of deranged liver enzymes especially medications and autoimmune related liver diseases.As the guideline suggests ultrasound is the preferred first-line diagnostic procedure for imaging of NAFLD,as it provides additional diagnostic information and the combination of biomarkers/scores and transient elastography might confer additional diagnostic accuracy and evident from previous similar studies too.展开更多
In order to promote the research on the evaluation index system of low-carbon city,this paper reviewed and summarized the current evaluation index systems in recent years and the concepts of lowcarbon city in China.Th...In order to promote the research on the evaluation index system of low-carbon city,this paper reviewed and summarized the current evaluation index systems in recent years and the concepts of lowcarbon city in China.The current evaluation index systems of low-carbon city in China could be divided into two types:two class index system and three class index system.The establishment of different index systems basically adheres to the scientific,systematic,operable and dynamic principles,and the target value and weight of evaluation index could be confirmed in multiple ways.This paper analyzed the existing problems in the evaluation index systems of low-carbon city,and came up with some suggestions and advice to promote relevant research.展开更多
The 5-parameter Morse potential (5-MP) of the interaction between H atom and Ag surfaces has been constructed. The adsorption and diffusion of H on Ag low-index surfaces are investigated with 5-MP in detail. The cha...The 5-parameter Morse potential (5-MP) of the interaction between H atom and Ag surfaces has been constructed. The adsorption and diffusion of H on Ag low-index surfaces are investigated with 5-MP in detail. The characteristics of critical points are obtained. The theoretical results show that H atom can only adsorb at the three-fold site on Ag(111 ); the quasi-3-fold site and long-bridge site are stable adsorption sites on Ag(110) surface for the H atom, and at low coverage hydrogen predominantly occupies the quasi-3-fold site. This work predicts that the four-fold hollow site is the most stable adsorption state for H atom on Ag(100). The results of this work are approved by the experimental and theoretical results.展开更多
Combining with the exigent demand of the development of satellite gravimetry system in China, aiming at the determination of technical indexes of gravity satellite orbit parameters, on the basis of the numerical exper...Combining with the exigent demand of the development of satellite gravimetry system in China, aiming at the determination of technical indexes of gravity satellite orbit parameters, on the basis of the numerical experiments and results analysis, the design indexes of gravity satellite orbit height, inter-satellite range and the orbit inclination are analyzed and calculated, and the issues towards twin gravity satellites such as coherence requirement of the orbit semi-major axes, control requirement of the pitch angle and time interval requirement to keep twin satellites formation in mobility are diseussed. Results show that the satellite orbit height is 400 km to 500 km, the inter-satellite range is about 220 km, the satellite orbit inclination is between polar orbit and sun-synchronous orbit, the semi-major axes difference of twin satellites orbit is within ± 70. 146 m, the pitch angle of twin satellites is about 0.9 degree, and the time interval to keep twin satellites formation in mobility is 7 days to 15 days.展开更多
This paper report on a low-loss, broadband, and tunable negative refractive index metamaterial (NRIM) consisting of yttrium iron garnet (YIG) slabs and printed circuit boards (PCBs). The YIG slabs under an applied mag...This paper report on a low-loss, broadband, and tunable negative refractive index metamaterial (NRIM) consisting of yttrium iron garnet (YIG) slabs and printed circuit boards (PCBs). The YIG slabs under an applied magnetic field provide a negative permeability and the PCBs provide a negative permittivity. The substrates of the PCBs decuple the interactions between the YIG slabs and wire array deposed on such substrates. The effective electromagnetic parameters of the NRIM and the conditions of exhibiting the negative refractive index character are analyzed theoretically. Then the negative transmission and negative refraction characters are investigated numerically and experimentally. The results indicate that the NRIM exhibits negative pass band within the X-band with a bandwidth of about 1 GHz and a peak transmission power of about - 2.5 dB. While changing the applied magnetic field from 2300 Oe to 2700 Oe, the measured pass band of NRIM shift from 8.42 GHz to 9.50 GHz with a 2.7 MHz/Oe step. The results open a sample way to fabricate the NRIM, further, the metamaterial cloak and absorber.展开更多
1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee o...1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery.展开更多
In the study on functional low-carbon ergonomic validity in buildings,ergonomic validity is different from resource validity which is easy for quantitative analysis. To eliminate the complexity and uncertainty impacts...In the study on functional low-carbon ergonomic validity in buildings,ergonomic validity is different from resource validity which is easy for quantitative analysis. To eliminate the complexity and uncertainty impacts of human factors on quantitative study,it proposes a method of building a parameter of ergonomic validity—multi-effect time by using cardiotachometer to record heart rate change,being used to evaluate the functional low-carbon ergonomic validity targeting at the ontological characteristics of kitchen. This method is used to determine the physical consumption intensity( multi-effect) through heart rate incremental relation based on the principles of physiology and ergonomics,and to confirm the ergonomic validity of environmental factors by the time to complete standard work as well as multi-effect quantitative analysis. The test results show that,under the kitchen operating conditions,the multi-effect( ME) can properly reflect the real-time status of the operator and is easily operated; the parameters obtained are not significantly related to the physiological status of the operator,and multi-effect time( MT) is sensitive to the physical consumption brought about to the operator due to kitchen environmental factors; thus,it can be taken as an objective index,which is simple and easy to operate in residential kitchen functional low-carbon evaluation.展开更多
Aimed at the low carbon economy and the characteristics of planning EIA in the industrial development region,the planning EIA index system which merged with the low carbon economy concept in the industrial development...Aimed at the low carbon economy and the characteristics of planning EIA in the industrial development region,the planning EIA index system which merged with the low carbon economy concept in the industrial development region was established.The construction planning of national eco-industrial park in Hefei High-tech Industrial Development Zone was comprehensively evaluated by using the gray correlation method.The evaluation results of considering and without considering the low carbon index were contrasted and were verified by using the improved entropy method.The results showed that the regional sustainable development index constantly rose,and the planning was reasonable.Moreover,the suggestions were also put forward to tackle the problems.展开更多
文摘The diagnosis of non-alcoholic fatty liver disease(NAFLD)and metabolic dysfunction-associated fatty liver disease only on the basis of laboratory parameter score such as Hepatic Steatosis Index which includes liver enzymes,gender,basal metabolic index,and presence of diabetic mellitus is not sufficient to exclude other causes of deranged liver enzymes especially medications and autoimmune related liver diseases.As the guideline suggests ultrasound is the preferred first-line diagnostic procedure for imaging of NAFLD,as it provides additional diagnostic information and the combination of biomarkers/scores and transient elastography might confer additional diagnostic accuracy and evident from previous similar studies too.
基金Sponsored by Ecology Leading Academic Discipline Project in Jiangsu ProvinceEnvironmental Science Leading Academic Discipline Project in NanjingScientific Research Project in Nanjing Xiaozhuang University(2012NXY24)
文摘In order to promote the research on the evaluation index system of low-carbon city,this paper reviewed and summarized the current evaluation index systems in recent years and the concepts of lowcarbon city in China.The current evaluation index systems of low-carbon city in China could be divided into two types:two class index system and three class index system.The establishment of different index systems basically adheres to the scientific,systematic,operable and dynamic principles,and the target value and weight of evaluation index could be confirmed in multiple ways.This paper analyzed the existing problems in the evaluation index systems of low-carbon city,and came up with some suggestions and advice to promote relevant research.
基金The project was supported by NSF of Shandong Province (Y2002B09)
文摘The 5-parameter Morse potential (5-MP) of the interaction between H atom and Ag surfaces has been constructed. The adsorption and diffusion of H on Ag low-index surfaces are investigated with 5-MP in detail. The characteristics of critical points are obtained. The theoretical results show that H atom can only adsorb at the three-fold site on Ag(111 ); the quasi-3-fold site and long-bridge site are stable adsorption sites on Ag(110) surface for the H atom, and at low coverage hydrogen predominantly occupies the quasi-3-fold site. This work predicts that the four-fold hollow site is the most stable adsorption state for H atom on Ag(100). The results of this work are approved by the experimental and theoretical results.
基金supported by the National Natural Science Foundation of China(41174026,41104047,41174017)the Key laboratory Foundation of Geo-space Environment and Geodesy of Ministry of Education(11-01-03)
文摘Combining with the exigent demand of the development of satellite gravimetry system in China, aiming at the determination of technical indexes of gravity satellite orbit parameters, on the basis of the numerical experiments and results analysis, the design indexes of gravity satellite orbit height, inter-satellite range and the orbit inclination are analyzed and calculated, and the issues towards twin gravity satellites such as coherence requirement of the orbit semi-major axes, control requirement of the pitch angle and time interval requirement to keep twin satellites formation in mobility are diseussed. Results show that the satellite orbit height is 400 km to 500 km, the inter-satellite range is about 220 km, the satellite orbit inclination is between polar orbit and sun-synchronous orbit, the semi-major axes difference of twin satellites orbit is within ± 70. 146 m, the pitch angle of twin satellites is about 0.9 degree, and the time interval to keep twin satellites formation in mobility is 7 days to 15 days.
文摘This paper report on a low-loss, broadband, and tunable negative refractive index metamaterial (NRIM) consisting of yttrium iron garnet (YIG) slabs and printed circuit boards (PCBs). The YIG slabs under an applied magnetic field provide a negative permeability and the PCBs provide a negative permittivity. The substrates of the PCBs decuple the interactions between the YIG slabs and wire array deposed on such substrates. The effective electromagnetic parameters of the NRIM and the conditions of exhibiting the negative refractive index character are analyzed theoretically. Then the negative transmission and negative refraction characters are investigated numerically and experimentally. The results indicate that the NRIM exhibits negative pass band within the X-band with a bandwidth of about 1 GHz and a peak transmission power of about - 2.5 dB. While changing the applied magnetic field from 2300 Oe to 2700 Oe, the measured pass band of NRIM shift from 8.42 GHz to 9.50 GHz with a 2.7 MHz/Oe step. The results open a sample way to fabricate the NRIM, further, the metamaterial cloak and absorber.
文摘1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery.
基金Sponsored by the "Twelfth Five-year" National Science and Technology Supoort Programe(Grant No.2011BAJ05B02-03)
文摘In the study on functional low-carbon ergonomic validity in buildings,ergonomic validity is different from resource validity which is easy for quantitative analysis. To eliminate the complexity and uncertainty impacts of human factors on quantitative study,it proposes a method of building a parameter of ergonomic validity—multi-effect time by using cardiotachometer to record heart rate change,being used to evaluate the functional low-carbon ergonomic validity targeting at the ontological characteristics of kitchen. This method is used to determine the physical consumption intensity( multi-effect) through heart rate incremental relation based on the principles of physiology and ergonomics,and to confirm the ergonomic validity of environmental factors by the time to complete standard work as well as multi-effect quantitative analysis. The test results show that,under the kitchen operating conditions,the multi-effect( ME) can properly reflect the real-time status of the operator and is easily operated; the parameters obtained are not significantly related to the physiological status of the operator,and multi-effect time( MT) is sensitive to the physical consumption brought about to the operator due to kitchen environmental factors; thus,it can be taken as an objective index,which is simple and easy to operate in residential kitchen functional low-carbon evaluation.
文摘Aimed at the low carbon economy and the characteristics of planning EIA in the industrial development region,the planning EIA index system which merged with the low carbon economy concept in the industrial development region was established.The construction planning of national eco-industrial park in Hefei High-tech Industrial Development Zone was comprehensively evaluated by using the gray correlation method.The evaluation results of considering and without considering the low carbon index were contrasted and were verified by using the improved entropy method.The results showed that the regional sustainable development index constantly rose,and the planning was reasonable.Moreover,the suggestions were also put forward to tackle the problems.