In this paper,the spray characteristics of a double-swirl low-emission combustor are analyzed by using Particle Imaging Velocimetry(PIV)and Planar Laser Induced Fluorescence(PLIF)technologies in an optical three-secto...In this paper,the spray characteristics of a double-swirl low-emission combustor are analyzed by using Particle Imaging Velocimetry(PIV)and Planar Laser Induced Fluorescence(PLIF)technologies in an optical three-sector combustor test rig.Interactions between sectors and the influence of main stage swirl intensity on spray structure are explained.The results illustrate that the swirl intensity has great effect on the flow field and spray structure.The spray cone angle is bigger when the swirl number is 0.7,0.9 than that when the swirl number is 0.5.The fuel distribution zone is larger and the distribution is more uniform when the swirl number is 0.5.The fuel concentration in the center area of the center plane of side sector(Plane 5)is larger than that of the center plane of middle sector(Plane 1).The spray cone angle in Plane 5 is larger than that in Plane 1.The width of spray cone becomes larger with the increase of Fuel-Air Ratio(FAR),whereas the spray cone angle under different fuel-air ratios are absolutely the same.The results of the mechanism of spray organization in this study can be used to support the design of new low-emission combustor.展开更多
In this paper,the flow field characteristics of a double-swirl low-emission combustor were analyzed by using Particle Imaging Velocimetry(PIV)technology in an optical three-sector combustor test rig.The interactions b...In this paper,the flow field characteristics of a double-swirl low-emission combustor were analyzed by using Particle Imaging Velocimetry(PIV)technology in an optical three-sector combustor test rig.The interactions between sectors and the flow field structure were explained.The results illustrated that there was a big difference between the flow field structures of the middle sector and the side sector under the same pressure drop,which was mainly induced by the interactions between sectors.The interactions made the swirl intensity of the middle sector weaker than that of the side sector,which made the recirculation zone of the middle sector be smaller than that of the side sector.With the increase of swirler pressure drop,the jet velocity at the exit of the swirler,the jet expansion angle,the width of the recirculation zone and the recirculating speed of the central axis became larger,enhancing the interactions between air streams from middle sector and side sector.The flow velocity in the central plane between sectors was small,especially the radial velocity,mainly because of the loss of the swirl intensity by the interactions between flow field of adjacent sectors.The expansion angle determined the position of the vortex in the primary recirculation zone;the axial and radial position of the vortex move downstream and radial outward with the increase of the jet expansion angle.The results of the mechanism of flow field organization in this study can be used to support the design of new low-emission combustor.展开更多
Effect of venturi angle and main stage swirl intensity on flow field and interactions were investigated using PIV.The results showed the difference between the side sector and the middle sector was caused by interacti...Effect of venturi angle and main stage swirl intensity on flow field and interactions were investigated using PIV.The results showed the difference between the side sector and the middle sector was caused by interactions.The interactions were stronger with the rise of the main stage swirl intensity.When the swirl intensity was 0.7 and 0.9,there was little difference of the width of the recirculation zone.But the flow field had a great difference when the swirl intensity was 0.5 and 0.7,which means that when the swirl intensity was small,the swirl intensity had a great influence on the flow field.Venturi angle had a great influence on the flow field structure and interactions when the venturi angle was big,such as 90°.The venturi angle just had a small influence on the width of the recirculation zone when the venturi angle was relatively small,such as 28°and 52°.The velocity of the center plane between two sectors(plane 3)was small.There was a recirculation zone at upstream of the center plane between two sectors(plane 3)when the swirl intensity was 0.7 and 0.9,whereas not one when the swirl intensity was 0.5.The above was induced by interactions.In addition,the velocity of plane 1,plane 3,and plane 5 when the venturi angle was 52°was smaller than that of 28°and 90°.展开更多
The paper sheds light on the idle lean blow off(LBO)problem for high fuel air ratio(FAR)com⁃bustor,which is impossible to be addressed with traditional aero combustor design.A significant improvement in aero combustor...The paper sheds light on the idle lean blow off(LBO)problem for high fuel air ratio(FAR)com⁃bustor,which is impossible to be addressed with traditional aero combustor design.A significant improvement in aero combustor design is required to resolve the idle LBO issue.The authors detailed a practical and efficient solu⁃tion,which not only solved the idle LBO issue but also defined the aero-thermal design for high-FAR combustor.The design will usher in a new era of aero combustor.展开更多
The characteristics of swirler flow field, including cold flow field and combustion flow field, in gas tur- bine combustor with two-stage swirler are studied by using particle image velocimetry (PIV). Velocity compo...The characteristics of swirler flow field, including cold flow field and combustion flow field, in gas tur- bine combustor with two-stage swirler are studied by using particle image velocimetry (PIV). Velocity compo- nents, fluctuation velocity, Reynolds stress and recirculation zone length are obtained, respectively. Influences of geometric parameter of primary hole, arrangement of primary hole, inlet air temperature, first-stage swirler an- gle and fuel/air ratio on flow field are investigated, respectively. The experimental results reveal that the primary recirculation zone lengths of combustion flow field are shorter than those of cold flow field, and the primary reeir- culation zone lengths decrease with the increase of inlet air temperature and fuel/air ratio. The change of the geo- metric parameter of primary hole casts an important influence on the swirler flow field in two-stage swirler com- bustor.展开更多
基金supported by the National Natural Science Foundation of China(Nos.51306182 and 51406202).
文摘In this paper,the spray characteristics of a double-swirl low-emission combustor are analyzed by using Particle Imaging Velocimetry(PIV)and Planar Laser Induced Fluorescence(PLIF)technologies in an optical three-sector combustor test rig.Interactions between sectors and the influence of main stage swirl intensity on spray structure are explained.The results illustrate that the swirl intensity has great effect on the flow field and spray structure.The spray cone angle is bigger when the swirl number is 0.7,0.9 than that when the swirl number is 0.5.The fuel distribution zone is larger and the distribution is more uniform when the swirl number is 0.5.The fuel concentration in the center area of the center plane of side sector(Plane 5)is larger than that of the center plane of middle sector(Plane 1).The spray cone angle in Plane 5 is larger than that in Plane 1.The width of spray cone becomes larger with the increase of Fuel-Air Ratio(FAR),whereas the spray cone angle under different fuel-air ratios are absolutely the same.The results of the mechanism of spray organization in this study can be used to support the design of new low-emission combustor.
基金supported by the Project 91641109 and the Project 51406202 of National Natural Science Foundation of China
文摘In this paper,the flow field characteristics of a double-swirl low-emission combustor were analyzed by using Particle Imaging Velocimetry(PIV)technology in an optical three-sector combustor test rig.The interactions between sectors and the flow field structure were explained.The results illustrated that there was a big difference between the flow field structures of the middle sector and the side sector under the same pressure drop,which was mainly induced by the interactions between sectors.The interactions made the swirl intensity of the middle sector weaker than that of the side sector,which made the recirculation zone of the middle sector be smaller than that of the side sector.With the increase of swirler pressure drop,the jet velocity at the exit of the swirler,the jet expansion angle,the width of the recirculation zone and the recirculating speed of the central axis became larger,enhancing the interactions between air streams from middle sector and side sector.The flow velocity in the central plane between sectors was small,especially the radial velocity,mainly because of the loss of the swirl intensity by the interactions between flow field of adjacent sectors.The expansion angle determined the position of the vortex in the primary recirculation zone;the axial and radial position of the vortex move downstream and radial outward with the increase of the jet expansion angle.The results of the mechanism of flow field organization in this study can be used to support the design of new low-emission combustor.
基金supported by National Natural Science Foundation of China(Grant No.51306182 and 61827802)。
文摘Effect of venturi angle and main stage swirl intensity on flow field and interactions were investigated using PIV.The results showed the difference between the side sector and the middle sector was caused by interactions.The interactions were stronger with the rise of the main stage swirl intensity.When the swirl intensity was 0.7 and 0.9,there was little difference of the width of the recirculation zone.But the flow field had a great difference when the swirl intensity was 0.5 and 0.7,which means that when the swirl intensity was small,the swirl intensity had a great influence on the flow field.Venturi angle had a great influence on the flow field structure and interactions when the venturi angle was big,such as 90°.The venturi angle just had a small influence on the width of the recirculation zone when the venturi angle was relatively small,such as 28°and 52°.The velocity of the center plane between two sectors(plane 3)was small.There was a recirculation zone at upstream of the center plane between two sectors(plane 3)when the swirl intensity was 0.7 and 0.9,whereas not one when the swirl intensity was 0.5.The above was induced by interactions.In addition,the velocity of plane 1,plane 3,and plane 5 when the venturi angle was 52°was smaller than that of 28°and 90°.
文摘The paper sheds light on the idle lean blow off(LBO)problem for high fuel air ratio(FAR)com⁃bustor,which is impossible to be addressed with traditional aero combustor design.A significant improvement in aero combustor design is required to resolve the idle LBO issue.The authors detailed a practical and efficient solu⁃tion,which not only solved the idle LBO issue but also defined the aero-thermal design for high-FAR combustor.The design will usher in a new era of aero combustor.
基金Supported by the National Natural Science Foundation of China(50906040)the Nanjing University of Aeronautics and Astronautics Research Funding(NZ2012107,NS2010052)~~
文摘The characteristics of swirler flow field, including cold flow field and combustion flow field, in gas tur- bine combustor with two-stage swirler are studied by using particle image velocimetry (PIV). Velocity compo- nents, fluctuation velocity, Reynolds stress and recirculation zone length are obtained, respectively. Influences of geometric parameter of primary hole, arrangement of primary hole, inlet air temperature, first-stage swirler an- gle and fuel/air ratio on flow field are investigated, respectively. The experimental results reveal that the primary recirculation zone lengths of combustion flow field are shorter than those of cold flow field, and the primary reeir- culation zone lengths decrease with the increase of inlet air temperature and fuel/air ratio. The change of the geo- metric parameter of primary hole casts an important influence on the swirler flow field in two-stage swirler com- bustor.