期刊文献+
共找到364,073篇文章
< 1 2 250 >
每页显示 20 50 100
General Properties of Low-frequency Power Losses in Fe-based Nanocrystalline Soft Magnetic Alloys 被引量:1
1
作者 Yanzhong ZHANG, Huijuan JIN and Ying SHI (Shanghai Key Laboratory for Research and Developing and Applications of Metallic Function Materials, Research Center, Shanghai Iron and Steel Research institute,Shanghai 200940, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第1期37-44,共8页
The dependences of the power loss per cycle on frequency f and amplitude flux density Bm have been investigated for the three main original magnetic states in five sorts of Fe-based nanocrystalline soft magnetic alloy... The dependences of the power loss per cycle on frequency f and amplitude flux density Bm have been investigated for the three main original magnetic states in five sorts of Fe-based nanocrystalline soft magnetic alloys in the ranges of 10 Hz<=f<=1000 Hz and 0.4 T<= Bm <=1.0 T. The total loss P is decomposed into the sum of the hysteresis loss Physt, the classical eddy current loss Pel and the excess loss Pexc. Physt has been found to be proportional to Bm^2 and f. The behavior of Pexc/f vs f being equivalent to P/f vs f clearly exhibits nonlinearity in the range not more than about 120 Hz, whereas the behavior of P/f vs f roughly shows linearity in the range far above 100 Hz and not more than 1000 Hz. In the range up to 1000 Hz, Physt is dominant in the original high permeability state and the state of low residual flux density, whereas Pexc in the state of high residual flux density is dominant in the wider range above about 100 Hz. The framework of the statistical theory of power loss has been used for representing the behavior of Pexc/f vs f. It has been found that the number n of the simultaneously active 'Magnetic Objects' linearly varies as n = n0 + Hexc/H0 as a function of the dynamic field Hexc in the range below about 120 Hz, whereas n approximately follows a law of the form n = n0 + (Hexc/H0)^m with 1 < m < 2 in the range far above 100 Hz and not more than 1000 Hz. The values of the field HO in principle related to the microstructure and the domain structure have been calculated for the three states. 展开更多
关键词 General Properties of low-frequency power Losses in Fe-based Nanocrystalline Soft Magnetic Alloys FE
下载PDF
Spiral piezoelectric transducer in torsional motion as low-frequency power harvester 被引量:1
2
作者 王海仁 胡洪平 +1 位作者 杨嘉实 胡元太 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2013年第5期589-596,共8页
A structure consisting of a spiral piezoelectric transducer and a concentrated mass is proposed as a low-frequency piezoelectric power harvester. A theoretical model is developed for the system from the theory of piez... A structure consisting of a spiral piezoelectric transducer and a concentrated mass is proposed as a low-frequency piezoelectric power harvester. A theoretical model is developed for the system from the theory of piezoelectricity. An analysis is performed to demonstrate the low-frequency nature of the system. Other basic characteristics of the power harvester including the output power, voltage, and efficiency are also calculated and examined. 展开更多
关键词 PIEZOELECTRIC torsional motion low-frequency power harvester
下载PDF
Low-frequency oscillation of train-network system considering traction power supply mode
3
作者 Yuchen Liu Xiaoqin Lyu +1 位作者 Mingyuan Chang Qiqi Yang 《Railway Engineering Science》 EI 2024年第2期244-256,共13页
The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified ra... The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified railway unilateral power supply system are not suitable for the LFO analysis in a bilateral power supply system,where the trains are supplied by two traction substations.In this work,based on the single-input and single-output impedance model of China CRH5 trains,the node admittance matrices of the train-network system both in unilateral and bilateral power supply modes are established,including three-phase power grid,traction transformers and traction network.Then the modal analysis is used to study the oscillation modes and propagation characteristics of the unilateral and bilateral power supply systems.Moreover,the influence of the equivalent inductance of the power grid,the length of the transmission line,and the length of the traction network are analyzed on the critical oscillation mode of the bilateral power supply system.Finally,the theoretical analysis results are verified by the time-domain simulation model in MATLAB/Simulink. 展开更多
关键词 low-frequency oscillation Train-network system Modal analysis Bilateral power supply Participation factor
下载PDF
Enhancing Low-Frequency Microwave Absorption Through Structural Polarization Modulation of MXenes
4
作者 Bo Shan Yang Wang +1 位作者 Xinyi Ji Yi Huang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第10期435-452,共18页
Two-dimensional carbon-based materials have shown promising electromagnetic wave absorption capabilities in mid-and high-frequency ranges,but face challenges in low-frequency absorption due to limited control over pol... Two-dimensional carbon-based materials have shown promising electromagnetic wave absorption capabilities in mid-and high-frequency ranges,but face challenges in low-frequency absorption due to limited control over polarization response mecha-nisms and ambiguous resonance behavior.In this study,we pro-pose a novel approach to enhance absorption efficiency in aligned three-dimensional(3D)MXene/CNF(cellulose nanofibers)cavities by modifying polarization properties and manipulating resonance response in the 3D MXene architecture.This controlled polarization mechanism results in a significant shift of the main absorption region from the X-band to the S-band,leading to a remarkable reflection loss value of-47.9 dB in the low-frequency range.Furthermore,our findings revealed the importance of the oriented electromagnetic coupling in influencing electromagnetic response and microwave absorption properties.The present study inspired us to develop a generic strategy for low-frequency tuned absorption in the absence of magnetic element participation,while orientation-induced polarization and the derived magnetic resonance coupling are the key controlling factors of the method. 展开更多
关键词 Hierarchical structure MXene Microwave absorption low-frequency
下载PDF
A seismic elastic moduli module for the measurements of low-frequency wave dispersion and attenuation of fluid-saturated rocks under different pressures
5
作者 Yan-Xiao He Shang-Xu Wang +9 位作者 Gen-Yang Tang Chao Sun Hong-Bing Li San-Yi Yuan Xian Wei Li-Deng Gan Xiao-Feng Dai Qiang Ge Peng-Peng Wei Hui-Qing Zhang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期162-181,共20页
Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and... Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and time-lapse seismic surveillance of both conventional and unconventional reservoir and overburden performances.A Seismic Elastic Moduli Module has been developed,based on the forced-oscillations method,to experimentally investigate the frequency dependence of Young's modulus and Poisson's ratio,as well as the inferred attenuation,of cylindrical samples under different confining pressure conditions.Calibration with three standard samples showed that the measured elastic moduli were consistent with the published data,indicating that the new apparatus can operate reliably over a wide frequency range of f∈[1-2000,10^(6)]Hz.The Young's modulus and Poisson's ratio of the shale and the tight sandstone samples were measured under axial stress oscillations to assess the frequency-and pressure-dependent effects.Under dry condition,both samples appear to be nearly frequency independent,with weak pressure dependence for the shale and significant pressure dependence for the sandstone.In particular,it was found that the tight sandstone with complex pore microstructure exhibited apparent dispersion and attenuation under brine or glycerin saturation conditions,the levels of which were strongly influenced by the increased effective pressure.In addition,the measured Young's moduli results were compared with the theoretical predictions from a scaled poroelastic model with a reasonably good agreement,revealing that the combined fluid flow mechanisms at both mesoscopic and microscopic scales possibly responsible for the measured dispersion. 展开更多
关键词 low-frequency measurements Dispersion and attenuation Rock physics Fluid flow
下载PDF
Suppression of low-frequency ultrasound broadband vibration using star-shaped single-phase metamaterials
6
作者 Rui Zhao Jian Zheng +4 位作者 Jin Guo Yunbo Shi Hengzhen Feng Jun Tang Jun Liu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期217-224,共8页
In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation pr... In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment. 展开更多
关键词 Star-shaped metamaterials BROADBAND Vibration attenuation low-frequency ultrasound vibration Transmission loss
下载PDF
Current optimization-based control of dual three-phase PMSM for low-frequency temperature swing reduction
7
作者 Linlin Lu Xueqing Wang +3 位作者 Luhan Jin Qiong Liu Yun Zhang Yao Mao 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期238-246,共9页
In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperatur... In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperature swing can be equivalent to reducing maximum instantaneous phase copper loss in this paper.First,a two-level optimization aiming at minimizing maximum instantaneous phase copper loss at each electrical angle is proposed.Then,the optimization is transformed to a singlelevel optimization by introducing the auxiliary variable for easy solving.Considering that singleobjective optimization trades a great total copper loss for a small reduction of maximum phase copper loss,the optimization considering both instantaneous total copper loss and maximum phase copper loss is proposed,which has the same performance of temperature swing reduction but with lower total loss.In this way,the proposed control scheme can reduce maximum junction temperature by 11%.Both simulation and experimental results are presented to prove the effectiveness and superiority of the proposed control scheme for low-frequency temperature swing reduction. 展开更多
关键词 Dual three-phase PMSM low-frequency temperature swing Copper loss Current optimization Connected neutral points
下载PDF
High-order Bragg forward scattering and frequency shift of low-frequency underwater acoustic field by moving rough sea surface
8
作者 莫亚枭 张朝金 +2 位作者 鹿力成 孙启航 马力 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期459-470,共12页
Acoustic scattering modulation caused by an undulating sea surface on the space-time dimension seriously affects underwater detection and target recognition.Herein,underwater acoustic scattering modulation from a movi... Acoustic scattering modulation caused by an undulating sea surface on the space-time dimension seriously affects underwater detection and target recognition.Herein,underwater acoustic scattering modulation from a moving rough sea surface is studied based on integral equation and parabolic equation.And with the principles of grating and constructive interference,the mechanism of this acoustic scattering modulation is explained.The periodicity of the interference of moving rough sea surface will lead to the interference of the scattering field at a series of discrete angles,which will form comb-like and frequency-shift characteristics on the intensity and the frequency spectrum of the acoustic scattering field,respectively,which is a high-order Bragg scattering phenomenon.Unlike the conventional Doppler effect,the frequency shifts of the Bragg scattering phenomenon are multiples of the undulating sea surface frequency and are independent of the incident sound wave frequency.Therefore,even if a low-frequency underwater acoustic field is incident,it will produce obvious frequency shifts.Moreover,under the action of ideal sinusoidal waves,swells,fully grown wind waves,unsteady wind waves,or mixed waves,different moving rough sea surfaces create different acoustic scattering processes and possess different frequency shift characteristics.For the swell wave,which tends to be a single harmonic wave,the moving rough sea surface produces more obvious high-order scattering and frequency shifts.The same phenomena are observed on the sea surface under fully grown wind waves,however,the frequency shift slightly offsets the multiple peak frequencies of the wind wave spectrum.Comparing with the swell and fully-grown wind waves,the acoustic scattering and frequency shift are not obvious for the sea surface under unsteady wind waves. 展开更多
关键词 high-order Bragg scattering frequency shift low-frequency acoustic field moving rough sea surface
下载PDF
A low-frequency pure metal metamaterial absorber with continuously tunable stiffness
9
作者 Xingzhong WANG Shiteng RUI +2 位作者 Shaokun YANG Weiquan ZHANG Fuyin MA 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第7期1209-1224,共16页
To address the incompatibility between high environmental adaptability and deep subwavelength characteristics in conventional local resonance metamaterials,and overcome the deficiencies in the stability of existing ac... To address the incompatibility between high environmental adaptability and deep subwavelength characteristics in conventional local resonance metamaterials,and overcome the deficiencies in the stability of existing active control techniques for band gaps,this paper proposes a design method of pure metal vibration damping metamaterial with continuously tunable stiffness for wideband elastic wave absorption.We design a dual-helix narrow-slit pure metal metamaterial unit,which possesses the triple advantage of high spatial compactness,low stiffness characteristics,and high structural stability,enabling the opening of elastic flexural band gaps in the low-frequency range.Similar to the principle of a sliding rheostat,the introduction of continuously sliding plug-ins into the helical slits enables the continuous variation of the stiffness of the metamaterial unit,achieving a continuously tunable band gap effect.This successfully extends the effective band gap by more than ten times.The experimental results indicate that this metamaterial unit can be used as an additional vibration absorber to absorb the low-frequency vibration energy effectively.Furthermore,it advances the metamaterial absorbers from a purely passive narrowband design to a wideband tunable one.The pure metal double-helix metamaterials retain the subwavelength properties of metamaterials and are suitable for deployment in harsh environments.Simultaneously,by adjusting its stiffness,it substantially broadens the effective band gap range,presenting promising potential applications in various mechanical equipment operating under adverse conditions. 展开更多
关键词 elastic metamaterial absorber continuously tunable stiffness low-frequency vibration damping variable stiffness design pure metal structure
下载PDF
Diagnosing ratio of electron density to collision frequency of plasma surrounding scaled model in a shock tube using low-frequency alternating magnetic field phase shift
10
作者 吴明兴 谢楷 +3 位作者 刘艳 徐晗 张宝 田得阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期519-530,共12页
A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic... A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma. 展开更多
关键词 low-frequency alternating magnetic field phase shift shock-tube plasma diagnosis electron density collision frequency
下载PDF
Method for measuring the low-frequency sound power from a complex sound source based on sound-field correction in a non-anechoic tank
11
作者 徐宏哲 李琪 +1 位作者 唐锐 尚大晶 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期504-519,共16页
Similar to air reverberation chambers, non-anechoic water tanks are important acoustic measurement devices that can be used to measure the sound power radiated from complex underwater sound sources using diffusion fie... Similar to air reverberation chambers, non-anechoic water tanks are important acoustic measurement devices that can be used to measure the sound power radiated from complex underwater sound sources using diffusion field theory. However,the problem of the poor applicability of low-frequency measurements in these tanks has not yet been solved. Therefore,we propose a low-frequency acoustic measurement method based on sound-field correction(SFC) in an enclosed space that effectively solves the problem of measuring the sound power from complex sound sources below the Schroeder cutoff frequency in a non-anechoic tank. Using normal mode theory, the transfer relationship between the mean-square sound pressure in an underwater enclosed space and the free-field sound power of the sound source is established, and this is regarded as a correction term for the sound field between this enclosed space and the free field. This correction term can be obtained based on previous measurements of a known sound source. This term can then be used to correct the mean-square sound pressure excited by any sound source to be tested in this enclosed space and equivalently obtain its free-field sound power. Experiments were carried out in a non-anechoic water tank(9.0 m × 3.1 m × 1.7 m) to confirm the validity of the SFC method. Through measurements with a spherical sound source(whose free-field radiation characteristics are known),the correction term of the sound field between this water tank and the free field was obtained. On this basis, the sound power radiated from a cylindrical shell model under the action of mechanical excitation was measured. The measurement results were found to have a maximum deviation of 2.9 d B from the free-field results. These results show that the SFC method has good applicability in the frequency band above the first-order resonant frequency in a non-anechoic tank. This greatly expands the potential low-frequency applications of non-anechoic tanks. 展开更多
关键词 non-anechoic tank complex sound source sound-field correction low-frequency sound power
下载PDF
ICU患者置入Power PICC导管特殊异位原因分析
12
作者 莫春玲 屈盈莹 李宝琪 《岭南急诊医学杂志》 2024年第1期58-60,共3页
目的:探讨ICU患者置入Power PICC导管后头端反折向上至同侧和对侧锁骨下静脉、头臂静脉等特殊异位的相关因素。方法:回顾性分析2021年9月至2022年9月某三甲医院ICU 520例PICC置管患者,通过胸部X线确定PICC导管头端反折向上至对侧和同侧... 目的:探讨ICU患者置入Power PICC导管后头端反折向上至同侧和对侧锁骨下静脉、头臂静脉等特殊异位的相关因素。方法:回顾性分析2021年9月至2022年9月某三甲医院ICU 520例PICC置管患者,通过胸部X线确定PICC导管头端反折向上至对侧和同侧锁骨下静脉、头臂静脉的患者,分析其特殊异位发生因素。结果:胸部X线结果显示25例患者PICC管头端反折向上异位至对侧和同侧锁骨下静脉、头臂静脉或颈内静脉,异位发生率4.8%,不同静脉置管反折异位发生率相比差异无统计学意义,P>0.05。结论:ICU患者PICC置入发生导管头端反折向上至同侧和对侧锁骨下静脉、头臂静脉等特殊异位的发生因素较多,包括同时留置CVC或血透管、正在滴注或泵入多种药物、PICC管头端异位的隐匿性、导管材质、自身疾病及机械通气等危险因素。 展开更多
关键词 ICU患者 power PICC 异位 原因分析
下载PDF
A bio-inspired spider-like structure isolator for low-frequency vibration 被引量:1
13
作者 Guangdong SUI Shuai HOU +5 位作者 Xiaofan ZHANG Xiaobiao SHAN Chengwei HOU Henan SONG Weijie HOU Jianming LI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第8期1263-1286,共24页
This paper proposes a quasi-zero stiffness(QZS)isolator composed of a curved beam(as spider foot)and a linear spring(as spider muscle)inspired by the precise capturing ability of spiders in vibrating environments.The ... This paper proposes a quasi-zero stiffness(QZS)isolator composed of a curved beam(as spider foot)and a linear spring(as spider muscle)inspired by the precise capturing ability of spiders in vibrating environments.The curved beam is simplified as an inclined horizontal spring,and a static analysis is carried out to explore the effects of different structural parameters on the stiffness performance of the QZS isolator.The finite element simulation analysis verifies that the QZS isolator can significantly reduce the first-order natural frequency under the load in the QZS region.The harmonic balance method(HBM)is used to explore the effects of the excitation amplitude,damping ratio,and stiffness coefficient on the system’s amplitude-frequency response and transmissibility performance,and the accuracy of the analytical results is verified by the fourth-order Runge-Kutta integral method(RK-4).The experimental data of the QZS isolator prototype are fitted to a ninth-degree polynomial,and the RK-4 can theoretically predict the experimental results.The experimental results show that the QZS isolator has a lower initial isolation frequency and a wider isolation frequency bandwidth than the equivalent linear isolator.The frequency sweep test of prototypes with different harmonic excitation amplitudes shows that the initial isolation frequency of the QZS isolator is 3 Hz,and it can isolate 90%of the excitation signal at 7 Hz.The proposed biomimetic spider-like QZS isolator has high application prospects and can provide a reference for optimizing low-frequency or ultra-low-frequency isolators. 展开更多
关键词 bionic isolation structure curved beam nonlinear stiffness quasi-zero stiffness(QzS) low-frequency vibration isolator
下载PDF
Power-V诱导的钻柱黏滑振动特征分析
14
作者 王文昌 段浩宇 +2 位作者 李宁 王孝亮 狄勤丰 《上海大学学报(自然科学版)》 CAS CSCD 北大核心 2024年第2期299-307,共9页
黏滑是石油钻井过程中影响钻井效率和井下钻柱安全的一种振动形式.垂直钻井系统Power-V在提供有效控斜力的同时,还会诱导钻柱黏滑振动.通过研究垂直钻井系统Power-V与井壁的接触作用及钻头与地层的相互作用模型,基于钻柱动力学有限元方... 黏滑是石油钻井过程中影响钻井效率和井下钻柱安全的一种振动形式.垂直钻井系统Power-V在提供有效控斜力的同时,还会诱导钻柱黏滑振动.通过研究垂直钻井系统Power-V与井壁的接触作用及钻头与地层的相互作用模型,基于钻柱动力学有限元方法,深入分析Power-V的作用机理,研究其对扭转振动的影响,指出Power-V和井壁间的相互作用会导致钻柱与井壁的摩阻显著增加,进而引起摩阻扭矩的增大,诱导井下黏滑振动.实测振动数据证实,Power-V与井壁间的相互作用是引起钻柱黏滑振动的关键因素.这对于揭示黏滑振动的成因和更好地发挥Power-V的作用具有重要意义. 展开更多
关键词 黏滑振动 钻柱动力学 振动信号测量 power-V
下载PDF
Low-Frequency Oscillation Analysis of Grid-Connected VSG System Considering Multi-Parameter Coupling
15
作者 Shengyang Lu Tong Wang +6 位作者 Yuanqing Liang Shanshan Cheng Yupeng Cai Haixin Wang Junyou Yang Yuqiu Sui Luyu Yang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第6期2373-2386,共14页
With the increasing integration of new energy generation into the power system and the massive withdrawal of traditional fossil fuel generation,the power system is faced with a large number of stability problems.The p... With the increasing integration of new energy generation into the power system and the massive withdrawal of traditional fossil fuel generation,the power system is faced with a large number of stability problems.The phenomenon of low-frequency oscillation caused by lack of damping and moment of inertia is worth studying.In recent years,virtual synchronous generator(VSG)technique has been developed rapidly because it can provide considerable damping and moment of inertia.While improving the stability of the system,it also inevitably causes the problem of active power oscillation,especially the low mutual damping between the VSG and the power grid will make the oscillation more severe.The traditional time-domain state-space method cannot reflect the interaction among state variables and study the interaction between different nodes and branches of the power grid.In this paper,a frequency-domain method for analyzing low-frequency oscillations considering VSG parameter coupling is proposed.First,based on the rotor motion equation of the synchronous generator(SG),a secondorder VSG model and linearized power-frequency control loop model are established.Then,the differences and connections between the coupling of key VSG parameters and low-frequency oscillation characteristics are studied through frequency domain analysis.The path and influencemechanism of a VSG during low-frequency power grid oscillations are illustrated.Finally,the correctness of the theoretical analysis model is verified by simulation. 展开更多
关键词 Inverter power supply low-frequency oscillation virtual synchronous generator rotor motor equation
下载PDF
基于调和概率语言术语集的Power平均算子
16
作者 辛树琦 王兴 郑小建 《福建师范大学学报(自然科学版)》 CAS 北大核心 2024年第2期1-13,共13页
实践发现现存概率语言Power平均算子在应用中存在概率信息丢失、计算过于繁琐等问题,针对这些问题,提出一种基于调和概率语言术语集的Power平均算子。结合新的基本运算法则与新的支撑度,给出新的概率语言Power平均算子、概率语言Power... 实践发现现存概率语言Power平均算子在应用中存在概率信息丢失、计算过于繁琐等问题,针对这些问题,提出一种基于调和概率语言术语集的Power平均算子。结合新的基本运算法则与新的支撑度,给出新的概率语言Power平均算子、概率语言Power几何平均算子、概率语言Power加权平均算子、概率语言Power加权几何平均算子,同时论证分析了这几类新型算子的性质。最后通过实验数据,将提出的算子与现存算子进行对比分析,验证了所提算子的有效性与可行性。 展开更多
关键词 概率语言术语集 概率语言power平均算子 决策
下载PDF
Power BI在我院药品数据可视化中的应用
17
作者 宋树杰 许桂媛 +2 位作者 马先杰 李祥鹏 刘建芳 《海峡药学》 2024年第8期121-127,共7页
目的加强医院药品精细化管理,提升药师对药品的数据分析能力,实现数据分析自动化及查询功能,为集采药品、麻精药品的动态监管提供数据支撑。方法使用数据可视化工具Power BI搭建服务,制作报表,能够查询药品使用情况和对比情况,实现各科... 目的加强医院药品精细化管理,提升药师对药品的数据分析能力,实现数据分析自动化及查询功能,为集采药品、麻精药品的动态监管提供数据支撑。方法使用数据可视化工具Power BI搭建服务,制作报表,能够查询药品使用情况和对比情况,实现各科室药品使用情况的可视化管理。结果通过该软件,药师可以精确查询任意时间维度下药品的使用数量、金额等情况,实现数据分析自动化。结论借助数据管理工具能够帮助药师提升数据分析能力和工作效率,有助于加强医院药品的精细化管控。 展开更多
关键词 power BI 药品集采 数据分析 药师
下载PDF
Observation of low-frequency oscillation in argon helicon discharge
18
作者 朱婉莹 崔瑞林 +2 位作者 韩若愚 何锋 欧阳吉庭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第2期86-94,共9页
We present here a kind of low-frequency oscillation in argon helicon discharge with a half helical antenna.This time-dependent instability shows a global quasi-periodic oscillation of plasma density and electron tempe... We present here a kind of low-frequency oscillation in argon helicon discharge with a half helical antenna.This time-dependent instability shows a global quasi-periodic oscillation of plasma density and electron temperature,with a typical frequency of a few tens of Hz which increases with external magnetic field as well as radiofrequency(RF)power.The relative oscillation amplitude decreases with magnetic field and RF power,but the rising time and pulse width do not change significantly under different discharge conditions.The oscillation can only be observed in some specific conditions of low magnetic fields and low RF power when the gas flows in from one end of the discharge area and out from another end.This global instability is suggested to be attributed to the pressure instability of neutral depletion,which is the result of compound action of gas depletion by heating expansion and gas replenishment from upstream.There are two kinds of oscillations,large and small amplitude oscillations,occurring in different discharge modes.This study could be a good verification of and complement to earlier experiments.This kind of spontaneous pulse phenomenon is also helpful in realizing a pulsing plasma source without a pulsed power supply. 展开更多
关键词 helicon plasma low-frequency oscillation global instability neutral depletion
下载PDF
A drift-kinetic perturbed Lagrangian for low-frequency nonideal MHD applications
19
作者 徐国盛 伍兴权 胡友俊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第7期35-41,共7页
We find that the perturbed Lagrangian derived from the drift-kinetic equation in[Porcelli F et al 1994 Phys.Plasmas 1470]is inconsistent with the ordering for the low-frequency large-scale magnetohydrodynamic(MHD).Her... We find that the perturbed Lagrangian derived from the drift-kinetic equation in[Porcelli F et al 1994 Phys.Plasmas 1470]is inconsistent with the ordering for the low-frequency large-scale magnetohydrodynamic(MHD).Here,we rederive the expression for the perturbed Lagrangian within the framework of nonideal MHD using the ordering system for the low-frequency largescale MHD in a low-beta plasma.The obtained perturbed Lagrangian is consistent with Chen's gyrokinetic theory[Chen L and Zonca F 2016 Rev.Mod.Phys.88015008],where the terms related to the field curvature and gradient are small quantities of higher order and thus negligible.As the perturbed Lagrangian has been widely used in the literature to calculate the plasma nonadiabatic response in low-frequency MHD applications,this finding may have a significant impact on the understanding of the kinetic driving and dissipative mechanisms of MHD instabilities and the plasma response to electromagnetic perturbations in fusion plasmas. 展开更多
关键词 perturbed Lagrangian drift kinetic low-frequency nonideal MHD fusion plasma
下载PDF
Carbon emission reduction:Contribution of photovoltaic power and practice in China 被引量:1
20
作者 Liang Wang Li-qiong Jia +2 位作者 Geng Xie Xi-jie Chen Yang Liu 《China Geology》 CAS CSCD 2024年第2期371-376,共6页
As a clean and renewable form of energy,photovoltaic(PV)power generation converts solar energy into electrical energy,reducing the consumption of fossil fuels and significantly lowering greenhouse gas emissions.Amidst... As a clean and renewable form of energy,photovoltaic(PV)power generation converts solar energy into electrical energy,reducing the consumption of fossil fuels and significantly lowering greenhouse gas emissions.Amidst the global transition towards cleaner forms of energy,countries all around the world are vigorously developing PV technology. 展开更多
关键词 CONVERT power EMISSIONS
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部