Inosine monophosphate(IMP),as a critical umami substance,is one of the most important indicators for evaluating the quality of meat products.Here,a sensitive electrochemiluminescence(ECL)biosensor based on graphdiyne(...Inosine monophosphate(IMP),as a critical umami substance,is one of the most important indicators for evaluating the quality of meat products.Here,a sensitive electrochemiluminescence(ECL)biosensor based on graphdiyne(GDY)/AuNPs/luminol nanocomposites was constructed to detect IMP.The GDY/AuNPs/luminol nanocomposites were synthesized by using simple one-pot method.GDY utilized its 2D framework to disperse and fix gold nanoparticles,which inhibited the agglomeration of gold nanoparticles and greatly improved its stability and catalytic properties.Importantly,GDY/AuNPs/luminol nanocomposites showed excellent catalytic ability and superior ECL activity towards luminol-H_(2)O_(2) systems due to the synergistic effect of GDY and AuNPs.Under optimal conditions,the prepared biosensor exhibited a wide linear range from 0.01 g/L to 20 g/L,a satisfactory limit detection of 0.0013 g/L,as well as an excellent specificity.Moreover,we carried out the precise analysis of IMP in actual meat samples with acceptable results compared to the liquid chromatography.We believe that this work could offer an efficient ECL platform for accurate and reliable report of IMP levels,which is significant for maintaining food quality and safety.展开更多
A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol...A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results.展开更多
A novel chemiluminescence(CL) sensor, which can be used for hydroxylamine determination in combination with flow injection analysis, was developed by electrostatically immobilizing luminol and periodate on anion exch...A novel chemiluminescence(CL) sensor, which can be used for hydroxylamine determination in combination with flow injection analysis, was developed by electrostatically immobilizing luminol and periodate on anion exchange resin respectively. Hydroxylamine was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The response of the sensor to hydroxylamine was linear in the concentration range of 8.0×10^(-8)-2.0×10^(-6)mol/L with a detection limit of 4.0×10^(-8)mol/L hydroxylamine(3σ).The relative standard deviation(RSD) was 2.0% for 9 repetitive determinations at a hydroxylamine concentration of 5.0×10^(-7) mol/L. The sensor could be reused for over 400 times with a good reproducibility and was used to determine hydroxylamine in wastewater.展开更多
The chemiluminescence reaction between luminol and reductant was investigated by a flow-injection system. The results show that this reaction can be used for the determination of the reductant which is active to chemi...The chemiluminescence reaction between luminol and reductant was investigated by a flow-injection system. The results show that this reaction can be used for the determination of the reductant which is active to chemiluminescence in alkaline lumminol, and of the substance which can, in appropriate manner, be converted into the active reductant. The mechanism of the chemiluminescence reaction may be that the reductant reduces dissolved oxygen to O2 , then O2 reacts with alkaline luminol to generate chemiluminescence.展开更多
基金supported by The National Natural Science Foundation of China(31972198,31622042)The National Key R&D Program of China(2016YFD0400803,2016YFD0401501).
文摘Inosine monophosphate(IMP),as a critical umami substance,is one of the most important indicators for evaluating the quality of meat products.Here,a sensitive electrochemiluminescence(ECL)biosensor based on graphdiyne(GDY)/AuNPs/luminol nanocomposites was constructed to detect IMP.The GDY/AuNPs/luminol nanocomposites were synthesized by using simple one-pot method.GDY utilized its 2D framework to disperse and fix gold nanoparticles,which inhibited the agglomeration of gold nanoparticles and greatly improved its stability and catalytic properties.Importantly,GDY/AuNPs/luminol nanocomposites showed excellent catalytic ability and superior ECL activity towards luminol-H_(2)O_(2) systems due to the synergistic effect of GDY and AuNPs.Under optimal conditions,the prepared biosensor exhibited a wide linear range from 0.01 g/L to 20 g/L,a satisfactory limit detection of 0.0013 g/L,as well as an excellent specificity.Moreover,we carried out the precise analysis of IMP in actual meat samples with acceptable results compared to the liquid chromatography.We believe that this work could offer an efficient ECL platform for accurate and reliable report of IMP levels,which is significant for maintaining food quality and safety.
基金This work was supported by the National Natural Science Foundation of China (No. 20005005) the Chenguang Project of Wuhan City (No. 20005004026).
文摘A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results.
基金Supported by the National Natural Science Foundation of China(No.2 9975 0 13,9835 110 )
文摘A novel chemiluminescence(CL) sensor, which can be used for hydroxylamine determination in combination with flow injection analysis, was developed by electrostatically immobilizing luminol and periodate on anion exchange resin respectively. Hydroxylamine was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The response of the sensor to hydroxylamine was linear in the concentration range of 8.0×10^(-8)-2.0×10^(-6)mol/L with a detection limit of 4.0×10^(-8)mol/L hydroxylamine(3σ).The relative standard deviation(RSD) was 2.0% for 9 repetitive determinations at a hydroxylamine concentration of 5.0×10^(-7) mol/L. The sensor could be reused for over 400 times with a good reproducibility and was used to determine hydroxylamine in wastewater.
基金Supported by the National Natural Science Foundation of China
文摘The chemiluminescence reaction between luminol and reductant was investigated by a flow-injection system. The results show that this reaction can be used for the determination of the reductant which is active to chemiluminescence in alkaline lumminol, and of the substance which can, in appropriate manner, be converted into the active reductant. The mechanism of the chemiluminescence reaction may be that the reductant reduces dissolved oxygen to O2 , then O2 reacts with alkaline luminol to generate chemiluminescence.