Vascular endothelial growth factor and its mimic peptide KLTWQELYQLKYKGI(QK)are widely used as the most potent angiogenic factors for the treatment of multiple ischemic diseases.However,conventional topical drug deliv...Vascular endothelial growth factor and its mimic peptide KLTWQELYQLKYKGI(QK)are widely used as the most potent angiogenic factors for the treatment of multiple ischemic diseases.However,conventional topical drug delivery often results in a burst release of the drug,leading to transient retention(inefficacy)and undesirable diffusion(toxicity)in vivo.Therefore,a drug delivery system that responds to changes in the microenvironment of tissue regeneration and controls vascular endothelial growth factor release is crucial to improve the treatment of ischemic stroke.Matrix metalloproteinase-2(MMP-2)is gradually upregulated after cerebral ischemia.Herein,vascular endothelial growth factor mimic peptide QK was self-assembled with MMP-2-cleaved peptide PLGLAG(TIMP)and customizable peptide amphiphilic(PA)molecules to construct nanofiber hydrogel PA-TIMP-QK.PA-TIMP-QK was found to control the delivery of QK by MMP-2 upregulation after cerebral ischemia/reperfusion and had a similar biological activity with vascular endothelial growth factor in vitro.The results indicated that PA-TIMP-QK promoted neuronal survival,restored local blood circulation,reduced blood-brain barrier permeability,and restored motor function.These findings suggest that the self-assembling nanofiber hydrogel PA-TIMP-QK may provide an intelligent drug delivery system that responds to the microenvironment and promotes regeneration and repair after cerebral ischemia/reperfusion injury.展开更多
Geothermal is a clean energy source that is freely available in the subsurface. The exploitation of this vital resource needs intensive exploration in order to identify and quantify its occurrence. The three parameter...Geothermal is a clean energy source that is freely available in the subsurface. The exploitation of this vital resource needs intensive exploration in order to identify and quantify its occurrence. The three parameters considered when assessing the viability of a geothermal system include;heat source, fractures and fluids. Geological structures are important in transportation of fluids to and from the heat source aiding in recharge of the geothermal system and enhancing productivity. Remote sensing method was applied in mapping the structures at Barrier Volcanic Complex (BVC) by using hill shading technique which utilized four illumination angles of the sun (azimuth) i.e. 45°, 90°, 150°, and 315°, constant elevation of 45° and exaggeration of 10. The data used was Shuttle Radar Topographic Mission (SRTM) Satellite Imagery. ArcGIS Software was used for lineaments delineation and density mapping, PCI Geomatica was used to generate major faults, while Georose and Rockworks 17 were used to generate the rose diagrams. Geological structural analysis was done by delineating lineaments, determining the density distribution of lineaments and finally determining the structural trends of lineaments. The generated major faults in the area and the location of the occurrence of surface manifestations were compared with the generated lineaments. A total of 260 lineaments were generated whereby at 45° there was a total of 60 lineaments, at 90° 95 lineaments, at 150° 61 lineaments, and at 315° 44 lineaments. The results of structural analysis in the area as shown by the rose diagrams indicate an NNE-SSW and N-S trending of structures. In conclusion, the study area is highly fractured as indicated by the presence of numerous lineaments. These lineaments provide good recharge to the geothermal system and enhance the geothermal reservoir in the area.展开更多
Control of dust in underground coal mines is critical for mitigating both safety and health hazards.For decades,the National Institute of Occupational Safety and Health(NIOSH)has led research to evaluate the effective...Control of dust in underground coal mines is critical for mitigating both safety and health hazards.For decades,the National Institute of Occupational Safety and Health(NIOSH)has led research to evaluate the effectiveness of various dust control technologies in coal mines.Recent studies have included the evaluation of auxiliary scrubbers to reduce respirable dust downstream of active mining and the use of canopy air curtains(CACs)to reduce respirable dust in key operator positions.While detailed dust characterization was not a focus of such studies,this is a growing area of interest.Using preserved filter samples from three previous NIOSH studies,the current work aims to explore the effect of two different scrubbers(one wet and one dry)and a roof bolter CAC on respirable dust composition and particle size distribution.For this,the preserved filter samples were analyzed by thermogravimetric analysis and/or scanning electron microscopy with energy dispersive X-ray.Results indicate that dust composition was not appreciably affected by either scrubber or the CAC.However,the wet scrubber and CAC appeared to decrease the overall particle size distribution.Such an effect of the dry scrubber was not consistently observed,but this is probably related to the particular sampling location downstream of the scrubber which allowed for significant mixing of the scrubber exhaust and other return air.Aside from the insights gained with respect to the three specific dust control case studies revisited here,this work demonstrates the value of preserved dust samples for follow-up investigation more broadly.展开更多
基金supported by the Natural Science Foundation of Shandong Province,No.ZR2023MC168the National Natural Science Foundation of China,No.31670989the Key R&D Program of Shandong Province,No.2019GSF107037(all to CS).
文摘Vascular endothelial growth factor and its mimic peptide KLTWQELYQLKYKGI(QK)are widely used as the most potent angiogenic factors for the treatment of multiple ischemic diseases.However,conventional topical drug delivery often results in a burst release of the drug,leading to transient retention(inefficacy)and undesirable diffusion(toxicity)in vivo.Therefore,a drug delivery system that responds to changes in the microenvironment of tissue regeneration and controls vascular endothelial growth factor release is crucial to improve the treatment of ischemic stroke.Matrix metalloproteinase-2(MMP-2)is gradually upregulated after cerebral ischemia.Herein,vascular endothelial growth factor mimic peptide QK was self-assembled with MMP-2-cleaved peptide PLGLAG(TIMP)and customizable peptide amphiphilic(PA)molecules to construct nanofiber hydrogel PA-TIMP-QK.PA-TIMP-QK was found to control the delivery of QK by MMP-2 upregulation after cerebral ischemia/reperfusion and had a similar biological activity with vascular endothelial growth factor in vitro.The results indicated that PA-TIMP-QK promoted neuronal survival,restored local blood circulation,reduced blood-brain barrier permeability,and restored motor function.These findings suggest that the self-assembling nanofiber hydrogel PA-TIMP-QK may provide an intelligent drug delivery system that responds to the microenvironment and promotes regeneration and repair after cerebral ischemia/reperfusion injury.
文摘Geothermal is a clean energy source that is freely available in the subsurface. The exploitation of this vital resource needs intensive exploration in order to identify and quantify its occurrence. The three parameters considered when assessing the viability of a geothermal system include;heat source, fractures and fluids. Geological structures are important in transportation of fluids to and from the heat source aiding in recharge of the geothermal system and enhancing productivity. Remote sensing method was applied in mapping the structures at Barrier Volcanic Complex (BVC) by using hill shading technique which utilized four illumination angles of the sun (azimuth) i.e. 45°, 90°, 150°, and 315°, constant elevation of 45° and exaggeration of 10. The data used was Shuttle Radar Topographic Mission (SRTM) Satellite Imagery. ArcGIS Software was used for lineaments delineation and density mapping, PCI Geomatica was used to generate major faults, while Georose and Rockworks 17 were used to generate the rose diagrams. Geological structural analysis was done by delineating lineaments, determining the density distribution of lineaments and finally determining the structural trends of lineaments. The generated major faults in the area and the location of the occurrence of surface manifestations were compared with the generated lineaments. A total of 260 lineaments were generated whereby at 45° there was a total of 60 lineaments, at 90° 95 lineaments, at 150° 61 lineaments, and at 315° 44 lineaments. The results of structural analysis in the area as shown by the rose diagrams indicate an NNE-SSW and N-S trending of structures. In conclusion, the study area is highly fractured as indicated by the presence of numerous lineaments. These lineaments provide good recharge to the geothermal system and enhance the geothermal reservoir in the area.
基金CDC/NIOSH for funding this research(75D30119C05529)。
文摘Control of dust in underground coal mines is critical for mitigating both safety and health hazards.For decades,the National Institute of Occupational Safety and Health(NIOSH)has led research to evaluate the effectiveness of various dust control technologies in coal mines.Recent studies have included the evaluation of auxiliary scrubbers to reduce respirable dust downstream of active mining and the use of canopy air curtains(CACs)to reduce respirable dust in key operator positions.While detailed dust characterization was not a focus of such studies,this is a growing area of interest.Using preserved filter samples from three previous NIOSH studies,the current work aims to explore the effect of two different scrubbers(one wet and one dry)and a roof bolter CAC on respirable dust composition and particle size distribution.For this,the preserved filter samples were analyzed by thermogravimetric analysis and/or scanning electron microscopy with energy dispersive X-ray.Results indicate that dust composition was not appreciably affected by either scrubber or the CAC.However,the wet scrubber and CAC appeared to decrease the overall particle size distribution.Such an effect of the dry scrubber was not consistently observed,but this is probably related to the particular sampling location downstream of the scrubber which allowed for significant mixing of the scrubber exhaust and other return air.Aside from the insights gained with respect to the three specific dust control case studies revisited here,this work demonstrates the value of preserved dust samples for follow-up investigation more broadly.