A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filte...A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations.展开更多
This study focuses on the experimental measurements of the heat transfer coefficient over a flat plate with a 30° leading edge. Under forced convection by a hot/cold air and flow over a cooled/heated flat plate, ...This study focuses on the experimental measurements of the heat transfer coefficient over a flat plate with a 30° leading edge. Under forced convection by a hot/cold air and flow over a cooled/heated flat plate, the thermal boundary layer and its thickness are quantitatively visualized and measured using a Mach-Zehnder interferometer. In addition, the variation in the local heat transfer coefficient is evaluated experimentally with respect to the air flow velocity and temperature. Differences within the heat transfer performance between the plates are confirmed and discussed. As a result, the average heat transfer performance is about the same for the heated plate and the cooled plate under all air velocity conditions. This contrasts with the theoretical prediction in the case of low air velocity, the reason considered was that the buoyancy at the 30° leading edge blocked air from flowing across the surface of the plate.展开更多
The temperature-induced complex refractive index(CRI) effect of graphene is demonstrated theoretically and experimentally based on a graphene coated in-fiber MZI(Mach-Zehnder interferometer). The relationships bet...The temperature-induced complex refractive index(CRI) effect of graphene is demonstrated theoretically and experimentally based on a graphene coated in-fiber MZI(Mach-Zehnder interferometer). The relationships between real and imaginary parts of the graphene CRI and temperature are obtained through investigating the dip wavelength and intensity of the MZI interference spectrum changing with temperature, respectively. The temperature effect of CRI of the graphene is also analyzed theoretically. Both experimental and theoretical studies show that the real part and imaginary part of the CRI nonlinearly decrease and increase with temperature increasing, respectively. This graphene-coated in-fiber MZI structure also possesses the advantages of easy fabrication, miniaturization, low cost and robustness. It has potential applications in nanomaterial-based optic devices for communication and sensing.展开更多
An air-spark switch plasma was diagnosed by the Mach–Zehnder laser interferometer with ultra-high spatial and temporal resolution. The interferograms containing plasma phase shift information at different time were o...An air-spark switch plasma was diagnosed by the Mach–Zehnder laser interferometer with ultra-high spatial and temporal resolution. The interferograms containing plasma phase shift information at different time were obtained. The phase shift distributions of the plasma were extracted by numerically processing the interferograms. The three-dimensional(3 D) electron density distributions of the air-spark switch plasma were then obtained. The working process of the air-spark switch was described by analyzing the temporal and spatial evolution of the plasma electron density.展开更多
We propose a method to implement a Mach-Zehnder interferometry based upon a string of trapped ions with artificial nonlinear interactions. By manipulating the coupling strength between two involved internal states of ...We propose a method to implement a Mach-Zehnder interferometry based upon a string of trapped ions with artificial nonlinear interactions. By manipulating the coupling strength between two involved internal states of the ions, we could achieve the beam splitting/recombination with NOON states. Using current techniques for manipulating trapped ions, we discuss the experimental feasibility of our scheme and analyze some undesired uncertainty under realistic experimental environment.展开更多
On the silicon-on-insulator platform, an ultra compact temperature-insensitive modulator based on a cascaded microring assistant Mach-Zehnder interferometer is proposed and demonstrated with numerical simulation. Acco...On the silicon-on-insulator platform, an ultra compact temperature-insensitive modulator based on a cascaded microring assistant Mach-Zehnder interferometer is proposed and demonstrated with numerical simulation. According to the calculated results, the tolerated variation of ambient temperature can be as high as 134 ℃ while the footprint of such a silicon modulator is only 340 μm2.展开更多
Fiber optic Mach Zehnder interferometer(MZI) can be used as wavelength multiplexers and demultiplexers. The △ L and △ directly influence the properties of MZI. To lengthen the △ L can demultiplex much more wavelen...Fiber optic Mach Zehnder interferometer(MZI) can be used as wavelength multiplexers and demultiplexers. The △ L and △ directly influence the properties of MZI. To lengthen the △ L can demultiplex much more wavelengths, but when the △ L is longer, the temperature will influence MZI more seriously. A method to solve this problem is proposed, which enables MZI to work stably. The wavelength distance is 0.8 nm, and the extinction ratio is high.展开更多
This work presents an optical method using the Mach–Zehnder interferometer. We especially diagnose a pure nitrogen gas subjected to a point to plane corona discharge, and visualize the density spatial map. The intere...This work presents an optical method using the Mach–Zehnder interferometer. We especially diagnose a pure nitrogen gas subjected to a point to plane corona discharge, and visualize the density spatial map. The interelectrode distance equals6 mm and the variation of the optical path has been measured at different pressures: 220 Torr, 400 Torr, and 760 Torr.The interferograms are recorded with a CCD camera, and the numerical analysis of these interferograms is assured by the inverse Abel transformation. The nitrogen density is extracted through the Gladstone–Dale relation. The obtained results are in close agreement with values available in the literature.展开更多
We propose a novel all fiber Mach-Zehnder interferometer(MZI) based on photonic crystal fiber(PCF) filled with liquid crystal(LC). The interference between the core mode and the cladding modes of a PCF is utiliz...We propose a novel all fiber Mach-Zehnder interferometer(MZI) based on photonic crystal fiber(PCF) filled with liquid crystal(LC). The interference between the core mode and the cladding modes of a PCF is utilized.To excite the cladding modes, a region is formed using fiber fusion splicer. Due to the fact that varying effective index difference between the core region and the LC-filled cladding region can cause different transmission spectra,we mainly study the MZIs with different LC-filled structures and different lengths of LC filling. The measured results demonstrate that quite clear interference spectra can be obtained. Through analysis spatial frequency spectrum and temperature spectrum of two MZIs with different LC-filled structures, we can obtain that the MZI with adjacent two LC-filled holes has clearer interference spectrum and higher temperature sensitivity. Thus we choose this MZI to measure the temperature sensitivity with different lengths of LC filling. When the length of LC filling is 2 cm, the temperature sensitivities can be enlarged to 1.59 nm/C. The interferometer shows a good temperature tunability and sensitivity, which can be a good candidate for a highly tunable optical filtering and temperature sensing applications.展开更多
This paper theoretically explores the effect of PM2.5 air pollution on the phase precision of a Mach-Zehnder inter- ferometer. With the increasing of PM2.5 concentration, phase precision for inputs of coherent state ...This paper theoretically explores the effect of PM2.5 air pollution on the phase precision of a Mach-Zehnder inter- ferometer. With the increasing of PM2.5 concentration, phase precision for inputs of coherent state & vacuum state and inputs of coherent state & squeezed vacuum state will gradually decrease and be lower than the standard quantum limit. When the value of relative humidity is increasing, the precision of two input cases is decreasing much faster. We also find that the precision for inputs of coherent state & squeezed state is better than that of coherent state & vacuum state when PM2.5 concentration is lower. As PM2.5 concentration increases, the precision for inputs of coherent state & squeezed state decreases faster, and then the two precisions tend to be the same while the concentration is higher.展开更多
基金Project supported by the Innovation Program of Education Commission of Shanghai Municipality (Grant No.10YZ19)the Shanghai Leading Academic Discipline Project (Grant No.S30108)the Shanghai Key Laboratory of Specialty Fiber Optics and Optical Access Networks (Grant No.SKLSFO200903)
文摘A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations.
文摘This study focuses on the experimental measurements of the heat transfer coefficient over a flat plate with a 30° leading edge. Under forced convection by a hot/cold air and flow over a cooled/heated flat plate, the thermal boundary layer and its thickness are quantitatively visualized and measured using a Mach-Zehnder interferometer. In addition, the variation in the local heat transfer coefficient is evaluated experimentally with respect to the air flow velocity and temperature. Differences within the heat transfer performance between the plates are confirmed and discussed. As a result, the average heat transfer performance is about the same for the heated plate and the cooled plate under all air velocity conditions. This contrasts with the theoretical prediction in the case of low air velocity, the reason considered was that the buoyancy at the 30° leading edge blocked air from flowing across the surface of the plate.
基金Project supported by the Shandong Provincial Natural Science Foundation of China(Grant Nos.ZR2009AM017 and ZR2013FM019)the National Postdoctoral Project of China(Grant Nos.200902574 and 20080441150)+2 种基金the Shandong Provincial Education Department Foundation of China(Grant No.J06P14)the Opening Foundation of State Key Lab of Minning Disaster Prevention and Control Co-founded by Shandong Provincethe Ministry of Science and Technology of China(Grant No.MDPC201602)
文摘The temperature-induced complex refractive index(CRI) effect of graphene is demonstrated theoretically and experimentally based on a graphene coated in-fiber MZI(Mach-Zehnder interferometer). The relationships between real and imaginary parts of the graphene CRI and temperature are obtained through investigating the dip wavelength and intensity of the MZI interference spectrum changing with temperature, respectively. The temperature effect of CRI of the graphene is also analyzed theoretically. Both experimental and theoretical studies show that the real part and imaginary part of the CRI nonlinearly decrease and increase with temperature increasing, respectively. This graphene-coated in-fiber MZI structure also possesses the advantages of easy fabrication, miniaturization, low cost and robustness. It has potential applications in nanomaterial-based optic devices for communication and sensing.
文摘An air-spark switch plasma was diagnosed by the Mach–Zehnder laser interferometer with ultra-high spatial and temporal resolution. The interferograms containing plasma phase shift information at different time were obtained. The phase shift distributions of the plasma were extracted by numerically processing the interferograms. The three-dimensional(3 D) electron density distributions of the air-spark switch plasma were then obtained. The working process of the air-spark switch was described by analyzing the temporal and spatial evolution of the plasma electron density.
基金Project supported by the Special Foundation for Theoretical Physics Research Program of China(Grant No.11347152)the Startup Funds for Scientific Research of Civil Aviation University of China(Grant No.2012QD13X)+3 种基金the Special Funds of the National Natural Science Foundation of China(Grant No.11247006)the National Natural Science Foundation of China(Grant Nos.11075223 and 11004226)the National Basic Research Program of China(Grants Nos.2012CB821305 and 2012CB922102)the Program for New Century Excellent Talents in University of Ministry of Education of China(Grant No.NCET-10-0850)
文摘We propose a method to implement a Mach-Zehnder interferometry based upon a string of trapped ions with artificial nonlinear interactions. By manipulating the coupling strength between two involved internal states of the ions, we could achieve the beam splitting/recombination with NOON states. Using current techniques for manipulating trapped ions, we discuss the experimental feasibility of our scheme and analyze some undesired uncertainty under realistic experimental environment.
基金Project supported by the National Basic Research Program of China(Grant Nos.2011CBA00608,2011CBA00303,2011CB301803, and 2010CB327405)the National Natural Science Foundation of China(Grant Nos.61036011 and 61036010)the Project of Science and Technology from the Communication Information Security Control Laboratory
文摘On the silicon-on-insulator platform, an ultra compact temperature-insensitive modulator based on a cascaded microring assistant Mach-Zehnder interferometer is proposed and demonstrated with numerical simulation. According to the calculated results, the tolerated variation of ambient temperature can be as high as 134 ℃ while the footprint of such a silicon modulator is only 340 μm2.
文摘Fiber optic Mach Zehnder interferometer(MZI) can be used as wavelength multiplexers and demultiplexers. The △ L and △ directly influence the properties of MZI. To lengthen the △ L can demultiplex much more wavelengths, but when the △ L is longer, the temperature will influence MZI more seriously. A method to solve this problem is proposed, which enables MZI to work stably. The wavelength distance is 0.8 nm, and the extinction ratio is high.
文摘This work presents an optical method using the Mach–Zehnder interferometer. We especially diagnose a pure nitrogen gas subjected to a point to plane corona discharge, and visualize the density spatial map. The interelectrode distance equals6 mm and the variation of the optical path has been measured at different pressures: 220 Torr, 400 Torr, and 760 Torr.The interferograms are recorded with a CCD camera, and the numerical analysis of these interferograms is assured by the inverse Abel transformation. The nitrogen density is extracted through the Gladstone–Dale relation. The obtained results are in close agreement with values available in the literature.
基金Supported by the National Natural Science Foundation of China under Grant Nos U1531102,61107059,61308052 and U1331114the 111 Project to the Harbin Engineering University under Grant No B13015the Fundamental Research Funds for the Central Universities
文摘We propose a novel all fiber Mach-Zehnder interferometer(MZI) based on photonic crystal fiber(PCF) filled with liquid crystal(LC). The interference between the core mode and the cladding modes of a PCF is utilized.To excite the cladding modes, a region is formed using fiber fusion splicer. Due to the fact that varying effective index difference between the core region and the LC-filled cladding region can cause different transmission spectra,we mainly study the MZIs with different LC-filled structures and different lengths of LC filling. The measured results demonstrate that quite clear interference spectra can be obtained. Through analysis spatial frequency spectrum and temperature spectrum of two MZIs with different LC-filled structures, we can obtain that the MZI with adjacent two LC-filled holes has clearer interference spectrum and higher temperature sensitivity. Thus we choose this MZI to measure the temperature sensitivity with different lengths of LC filling. When the length of LC filling is 2 cm, the temperature sensitivities can be enlarged to 1.59 nm/C. The interferometer shows a good temperature tunability and sensitivity, which can be a good candidate for a highly tunable optical filtering and temperature sensing applications.
基金Project supported by the National Natural Science Foundation of China(Grant No.61306131)the Science Foundation of Shaanxi Provincial Department of Education,China(Grant No.14JK1682)
文摘This paper theoretically explores the effect of PM2.5 air pollution on the phase precision of a Mach-Zehnder inter- ferometer. With the increasing of PM2.5 concentration, phase precision for inputs of coherent state & vacuum state and inputs of coherent state & squeezed vacuum state will gradually decrease and be lower than the standard quantum limit. When the value of relative humidity is increasing, the precision of two input cases is decreasing much faster. We also find that the precision for inputs of coherent state & squeezed state is better than that of coherent state & vacuum state when PM2.5 concentration is lower. As PM2.5 concentration increases, the precision for inputs of coherent state & squeezed state decreases faster, and then the two precisions tend to be the same while the concentration is higher.