Numerical and experimental investigation results on the magnetohydrodynamics(MHD) film flows along flat and curved bottom surfaces are summarized in this study. A simplified modeling has been developed to study the ...Numerical and experimental investigation results on the magnetohydrodynamics(MHD) film flows along flat and curved bottom surfaces are summarized in this study. A simplified modeling has been developed to study the liquid metal MHD film state, which has been validated by the existing experimental results. Numerical results on how the inlet velocity(V), the chute width(W) and the inlet film thickness(d0) affect the MHD film flow state are obtained. MHD stability analysis results are also provided in this study. The results show that strong magnetic fields make the stable V decrease several times compared to the case with no magnetic field,especially small radial magnetic fields(Bn) will have a significant impact on the MHD film flow state. Based on the above numerical and MHD stability analysis results flow control methods are proposed for flat and curved MHD film flows. For curved film flow we firstly proposed a new multi-layers MHD film flow system with a solid metal mesh to get the stable MHD film flows along the curved bottom surface. Experiments on flat and curved MHD film flows are also carried out and some firstly observed results are achieved.展开更多
The large current generated by starting directly of super large capacity and high voltage induction motor would have a huge impact on the grid as well as the motor itself.The variation of the power factor and electrom...The large current generated by starting directly of super large capacity and high voltage induction motor would have a huge impact on the grid as well as the motor itself.The variation of the power factor and electromagnetic torque during direct start of motors with different capacity and voltage levels are obtained.Aiming at the problem that the secondary impact of auto-transformer starter is too large and the cost of magnetic control starter is too high,the auto-transformer and magnetic control soft start method of super large capacity and high voltage motor is proposed and the basic working principle is analyzed.The calculation formula of cost for magnetic control soft starter and auto-transformer and magnetic control soft starter is deduced,and specific examples are analyzed and compared.It is concluded that the choice of auto-transformer with appropriate tapping ratio can greatly reduce the cost of auto-transformer and magnetic control soft starter compared with the other one.Finally,the simulation and experiment results show that the start method can effectively avoid secondary current impact and constrain the motor starting current to less than 2.5 times the rated current.展开更多
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2014GB125003 and 2013GB114002)National Natural Science Foundation of China(No.11105044)
文摘Numerical and experimental investigation results on the magnetohydrodynamics(MHD) film flows along flat and curved bottom surfaces are summarized in this study. A simplified modeling has been developed to study the liquid metal MHD film state, which has been validated by the existing experimental results. Numerical results on how the inlet velocity(V), the chute width(W) and the inlet film thickness(d0) affect the MHD film flow state are obtained. MHD stability analysis results are also provided in this study. The results show that strong magnetic fields make the stable V decrease several times compared to the case with no magnetic field,especially small radial magnetic fields(Bn) will have a significant impact on the MHD film flow state. Based on the above numerical and MHD stability analysis results flow control methods are proposed for flat and curved MHD film flows. For curved film flow we firstly proposed a new multi-layers MHD film flow system with a solid metal mesh to get the stable MHD film flows along the curved bottom surface. Experiments on flat and curved MHD film flows are also carried out and some firstly observed results are achieved.
基金This work was supported in part by the National Key Research and Development Program of China under Grant 2017YFB0902904,in part by the Natural Science Foundation of Hubei Province under Grant 2016CFB448,and in part by the Shenzhen City Science and Technology Innovation Plan under Grant JCYJ20170306170937861,and in part by Wuhan City Science and Technology Program under Grant 2016070204020165.
文摘The large current generated by starting directly of super large capacity and high voltage induction motor would have a huge impact on the grid as well as the motor itself.The variation of the power factor and electromagnetic torque during direct start of motors with different capacity and voltage levels are obtained.Aiming at the problem that the secondary impact of auto-transformer starter is too large and the cost of magnetic control starter is too high,the auto-transformer and magnetic control soft start method of super large capacity and high voltage motor is proposed and the basic working principle is analyzed.The calculation formula of cost for magnetic control soft starter and auto-transformer and magnetic control soft starter is deduced,and specific examples are analyzed and compared.It is concluded that the choice of auto-transformer with appropriate tapping ratio can greatly reduce the cost of auto-transformer and magnetic control soft starter compared with the other one.Finally,the simulation and experiment results show that the start method can effectively avoid secondary current impact and constrain the motor starting current to less than 2.5 times the rated current.