Study on Magnetic Field Distribution in Electromagnetic Ingot Casting Mold for Extra Heavy Plate
1
作者 XU Chang-jun HU Lin +4 位作者 WANG Qi HU Xiao-dong ZHENG Pei-liang LI Dong-xu ZHAO Lian-gang 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2012年第S2期637-642,共6页
The dual-frequency electromagnetic ingot casting(DFEMIC)method with copper water-cooled ingot mold for extra heavy plate was developed.Electromagnetic field distribution in ingot mold was measured through the teslamet... The dual-frequency electromagnetic ingot casting(DFEMIC)method with copper water-cooled ingot mold for extra heavy plate was developed.Electromagnetic field distribution in ingot mold was measured through the teslameter,the shielding effect of the copper ingot mold was judged,it is less than 37.7%of magnetic flux density when there is no ingot mold.The average shielding the magnetic field proportion of copper ingot mold reduced to 54.9%after loading '「' type the magnetic yoke and adjusting its distribution.Improving electromagnetic power can increase the magnetic field strength. Using the slit combination ingot mold could help increasing magnetic flux density in ingot mold.Steel structure outside ingot mold also have interference on magnetic field distribution in ingot mold,Therefore,it is important to paid more attention to electromagnetic shielding and the uniform symmetry of system structure. 展开更多
关键词 extra heavy plate dual frequency electromagnetic field magnetic yoke POWER