A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by o...A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetonitrile to remove the interference proteins. A reverse phase column of SHIM- PACK VP-ODS (150 mm × 4.6 mm, 5.0 μm) was used to separate 4-O-methylhonokiol in the plasma samples. The detection limit of 4-O-methylhonokiol was 0.2 μg/L and the linear range was 0. 012 - 1. 536 mg/L. The good extraction recoveries were obtained for the spiked samples (84.7%, 89.3% and 87.7% for low, middle and high concentrations of added standards, respectively). The relative standard deviation of intra-day and inter-day precisions was in the range from 0.6% to 13.5%. The pharmacokinetic study of 4-O-methylhonokiol was made and the results from the plasmaconcentration curve of 4-0-methylhonokiol showed a two-apartment open model. This work developed a sensitive, stable and rapid HPLC method for the determination of 4-O-methylhonokiol and the developed method has been successfully applied to a pharmacokinetic study of 4-O-methylhonokiol.展开更多
基金supported by Xi'an Jiaotong University(No.01380011)
文摘A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetonitrile to remove the interference proteins. A reverse phase column of SHIM- PACK VP-ODS (150 mm × 4.6 mm, 5.0 μm) was used to separate 4-O-methylhonokiol in the plasma samples. The detection limit of 4-O-methylhonokiol was 0.2 μg/L and the linear range was 0. 012 - 1. 536 mg/L. The good extraction recoveries were obtained for the spiked samples (84.7%, 89.3% and 87.7% for low, middle and high concentrations of added standards, respectively). The relative standard deviation of intra-day and inter-day precisions was in the range from 0.6% to 13.5%. The pharmacokinetic study of 4-O-methylhonokiol was made and the results from the plasmaconcentration curve of 4-0-methylhonokiol showed a two-apartment open model. This work developed a sensitive, stable and rapid HPLC method for the determination of 4-O-methylhonokiol and the developed method has been successfully applied to a pharmacokinetic study of 4-O-methylhonokiol.