This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of ...This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of smart devices.Using the proposed method,the performance is evaluated by conducting data transmission tests between a smart book and smart phone.The test results confirm that the proposed method can send 32 bits of data in an average of 235 ms,the transmission success rate reaches 99.47%,and the error detection rate of the cyclic redundancy check is0.53%.展开更多
High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industr...High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industrial processes. Some requirements of complex PLC systems cannot be satisfied by the traditional verification methods. In this paper, an efficient method for the PLC systems modeling and verification is proposed. To ensure the high-speed property of PLC, we proposed a technique of “Time interval model” and “notice-waiting”. It could reduce the state space and make it possible to verify some complex PLC systems. Also, the conversion from the built PLC model to the Promela language is obtained and a tool PLC-Checker for modeling and checking PLC systems are designed. Using PLC-Checker to check a classical PLC example, a counter-example is found. Although the probability of this logic error occurs very small, it could result in system crash fatally.展开更多
基金supported by Ministry of Educationunder Basic Science Research Program under Grant No.NRF-2013R1A1A2061478
文摘This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of smart devices.Using the proposed method,the performance is evaluated by conducting data transmission tests between a smart book and smart phone.The test results confirm that the proposed method can send 32 bits of data in an average of 235 ms,the transmission success rate reaches 99.47%,and the error detection rate of the cyclic redundancy check is0.53%.
文摘High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industrial processes. Some requirements of complex PLC systems cannot be satisfied by the traditional verification methods. In this paper, an efficient method for the PLC systems modeling and verification is proposed. To ensure the high-speed property of PLC, we proposed a technique of “Time interval model” and “notice-waiting”. It could reduce the state space and make it possible to verify some complex PLC systems. Also, the conversion from the built PLC model to the Promela language is obtained and a tool PLC-Checker for modeling and checking PLC systems are designed. Using PLC-Checker to check a classical PLC example, a counter-example is found. Although the probability of this logic error occurs very small, it could result in system crash fatally.