AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent biman...AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.展开更多
AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer (ORA) after 2.2-ram microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification. METHODS: The prospectiv...AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer (ORA) after 2.2-ram microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification. METHODS: The prospective nonrandomized study comprised eyes with cataract that had 2.2-mm coaxial microincision or 3.0 -mm standard incision phacoemulsification. The corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) were measured by ORA preoperatively and at ld, 1-, 2-, 3- and 4-week postoperatively. Results were analyzed and compared between groups. RESULTS: In both groups, CH decreased in the immediate postoperative period (P〈0.05), returned to the preoperative level at one week (P =0.249) in the 2.2-mm group, and at two weeks in the 3.0-mm group (P --0.264); there was no significant change in CRF values. In 2.2-mm group, mean IOPcc and IOPg increased at ld postoperatively (both ,P〈0.05), and returned to preoperative level at one week (,0 =0.491 and P =0.923, respectively). In 3.0-mm group, mean IOPcc and IOPg increased at ld and lwk postoperatively (P =0.005 and ,P =0.029, respectively), and returned to preoperative level at 2wk (P =0.347 and P =0.887, respectively). CONCLUSION: Significant differences between preoperative and postoperative corneal biomechanical values were found for CH, IOPcc and IOPg. But the recovery time courses were different between the two groups. The 2.2-mm coaxial microincision cataract surgery group seemed recovery faster compared to the 3.0-mm standard coaxial phacoemulsification group.展开更多
文摘AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.
基金Supported by Shanxi Provincial Health Department of Science and Technology Research Projects (No.201201019)
文摘AIM: To compare the changes in corneal biomechanics measured by ocular response analyzer (ORA) after 2.2-ram microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification. METHODS: The prospective nonrandomized study comprised eyes with cataract that had 2.2-mm coaxial microincision or 3.0 -mm standard incision phacoemulsification. The corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) were measured by ORA preoperatively and at ld, 1-, 2-, 3- and 4-week postoperatively. Results were analyzed and compared between groups. RESULTS: In both groups, CH decreased in the immediate postoperative period (P〈0.05), returned to the preoperative level at one week (P =0.249) in the 2.2-mm group, and at two weeks in the 3.0-mm group (P --0.264); there was no significant change in CRF values. In 2.2-mm group, mean IOPcc and IOPg increased at ld postoperatively (both ,P〈0.05), and returned to preoperative level at one week (,0 =0.491 and P =0.923, respectively). In 3.0-mm group, mean IOPcc and IOPg increased at ld and lwk postoperatively (P =0.005 and ,P =0.029, respectively), and returned to preoperative level at 2wk (P =0.347 and P =0.887, respectively). CONCLUSION: Significant differences between preoperative and postoperative corneal biomechanical values were found for CH, IOPcc and IOPg. But the recovery time courses were different between the two groups. The 2.2-mm coaxial microincision cataract surgery group seemed recovery faster compared to the 3.0-mm standard coaxial phacoemulsification group.