Photoacoustic imaging is a potential candidate for in vivo brain imaging,whereas,its imaging performance could be degraded by inhomogeneous multi-layered media,consisted of scalp and skull.In this work,we propose a lo...Photoacoustic imaging is a potential candidate for in vivo brain imaging,whereas,its imaging performance could be degraded by inhomogeneous multi-layered media,consisted of scalp and skull.In this work,we propose a low-artifact photoacoustic microscopy(LAPAM)scheme,which combines conventional acoustic-resolution photoacoustic microscopy with scanning acoustic microscopy to suppress the reflection artifacts induced by multi-layers.Based on similar propagation characteristics of photoacoustic signals and ultrasonic echoes,the ultrasonic echoes can be employed as the filters to suppress the reflection artifacts to obtain low-artifact photoacoustic images.Phantom experiment is used to validate the effectiveness of this method.Furthermore,LAPAM is applied for in-vivo imaging mouse brain without removing the scalp and the skull.Experimental results show that the proposed method successfully achieves the low-artifact brain image,which demonstrates the practical applicability of LAPAM.This work might improve the photoacoustic imaging quality in many biomedical applications which involve tissues with complex acoustic properties,such as brain imaging through scalp and skull.展开更多
In this paper the elastic properties of SiOx film are investigated quantitatively for local fixed point and qualitatively for overall area by atomic force acoustic microscopy (AFAM) in which the sample is vibrated a...In this paper the elastic properties of SiOx film are investigated quantitatively for local fixed point and qualitatively for overall area by atomic force acoustic microscopy (AFAM) in which the sample is vibrated at the ultrasonic frequency while the sample surface is touched and scanned with the tip contacting the sample respectively for fixed point and continuous measurements. The SiOx films on the silicon wafers are prepared by the plasma enhanced chemical vapour deposition (PECVD), The local contact stiffness of the tip-SiOx film is calculated from the contact resonance spectrum measured with the atomic force acoustic microscopy. Using the reference approach, indentation modulus of SiOx film for fixed point is obtained. The images of cantilever amplitude are also visualized and analysed when the SiOx surface is excited at a fixed frequency. The results show that the acoustic amplitude images can reflect the elastic properties of the sample.展开更多
To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these me...To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes.展开更多
C-mode scanning acoustical microscopy, C-SAM, is widely used in plastic package evaluations and for failure analysis. It permits to detect subsurface delaminations, cracks and pores (air bubbles) for different micro...C-mode scanning acoustical microscopy, C-SAM, is widely used in plastic package evaluations and for failure analysis. It permits to detect subsurface delaminations, cracks and pores (air bubbles) for different microelectronics packages. In this study, abnormality was observed in C-SAM daily test, the images showed no delaminations but inhomogeneities on the IC surface. Corrosion was found by optical microscope and scanning electron microscope after decapsulation. It can be revealed as the acoustic impedance is different between corrosion and normal area. The presence of inhomogeneities and discontinuities along ultrasonic waves' propagation paths inside the matter causes modifications in the amplitude and polarity of ultrasonic waves. However, C-SAM's capability in detecting IC surface corrosion has not been presented. The capability will be illustrated and the inspection mechanism will be discussed in this paper.展开更多
Traditional technique such nanoindenter(NI) can't measure the local elastic modulus at nano-scale(lateral). Atomic force acoustic microscopy (AFAM) is a dynamic method, which can quantitatively determine indent...Traditional technique such nanoindenter(NI) can't measure the local elastic modulus at nano-scale(lateral). Atomic force acoustic microscopy (AFAM) is a dynamic method, which can quantitatively determine indentation modulus by measuring the contact resonance spectra for high order modes of the cantilever. But there are few reports on the effect of experimental factors, such length of cantilever, contact stiffness on measured value. For three different samples, including copper(Cu) film with 110 nm thickness, zinc(Zn) film of 90 nm thickness and glass slides, are prepared and tested, using referencing approach in which measurements are performed on the test and reference samples (it's elastic modulus is known), and their contact resonance spectra are measured used the AFAM system experimentally. According to the vibration theory, from the lowest two contact resonance frequencies, the tip-sample contact stiffness is calculated, and then the values for the elastic properties of test sample, such as the indentation modulus, are determined. Using AFAM system, the measured indentation modulus of copper nano-film, zinc nano-film and glass slides are 113.53 GPa, 87.92 GPa and 57.04 GPa, which are agreement with literature values Mcu--105-130 GPa, Mzn = 88.44 GPa and Molass = 50-90 GPa. Furthermore, the sensitivity of contact resonance frequency to contact stiffness is analyzed theoretically. The results show that for the cantilevers with the length 160 pm, 225 μm and 520 μm respectively, when contact stiffness increases from 400 N/m to 600 N/m, the increments of first contact resonance frequency are 126 kHz, 93 kHz and 0.6 kHz, which show that the sensitivity of the contact resonance frequency to the contact stiffness reduces with the length of cantilever increasing. The novel method presented can characterize elastic modulus of near surface for nano-film and bulk material, and local elasticity of near surface can be evaluated by optimizing the experimental parameters using the AFAM system.展开更多
Aims: Dilated cardiomyopathy often shows left ventricular systolic dysfunction, although histologically it always exhibits non-specific abnormality. We hypothesized that myocyte sound speed might be altered due to inc...Aims: Dilated cardiomyopathy often shows left ventricular systolic dysfunction, although histologically it always exhibits non-specific abnormality. We hypothesized that myocyte sound speed might be altered due to incomplete protein accumulation in cells. Methods and Results: Ninety eight biopsied samples were obtained from 49 patients comprising 43 with clinical dilated cardiomyopathy and 6 with hypertrophic cardiomyopathy. Sound speed was evaluated in deparaffinized 10 μm thick sections using an acoustic microscope (frequency range: 50 - 105 MHz). Conventional histology revealed 7 cases of persistent myocarditis derived from clinical dilated cardio- myopathy samples. Histology of the remaining dilated cardiomyopathy patients indicated non-specific abnormality. All hypertrophic cardiomyopathy cases exhibited myocardial disarray. Ten normal autopsied hearts were compared as controls. The sound speed of controls was 1627 ± 30m/sec. The sound speed in dilated cardiomyopathy samples (1700 ±51m/sec) was 1.045-fold faster compared to controls. The sound speed in hypertrophic cardiomyopathy samples (1734 ±51m/sec, 1.066-fold compared to controls) was faster than that of the myocarditis group (1672 ±30m/sec, 1.028-fold) (P = 0.0218). Furtheremore, desmin expression was evaluated as extent of emergence (grading 0 - 4). The desmin expression score in hypertrophic cardiomyopathy samples (2.7 ± 0.8) was significantly higher than in other groups (dilated 2.0 ± 1.4, myocarditis 1.6 ± 1.5 vs., controls 0, P ≤ 0.0001, 0.0001, 0.0129, respectively). Conclusion: Cardio-myopathy enhanced the sound speed, which correlated with the elasticity of myocytes, following the impaired compliance of left ventricle, despite the absence of histological changes. The elevation of sound speed of myocytes may be linked to cytoskeletal changes. Myocyte sound speed may be a new diagnostic tool for diagnosis of idiopathic cardiomyopathy independently of conventional histological diagnosis.展开更多
In this work, C-Scan Acoustic Scanning Microscopy (ASM) is used to map the defects of three SiC samples. The acoustic images indicate that numerous defects with different shapes and area?sexist in the wafers. Some of ...In this work, C-Scan Acoustic Scanning Microscopy (ASM) is used to map the defects of three SiC samples. The acoustic images indicate that numerous defects with different shapes and area?sexist in the wafers. Some of the defects have areas of more than 100,000 μm2. The number of defects ranges from 1 to 50 defects/wafer. Defect mapping is essential for defect repairing or avoidance.?This work shows that ASM can locate the precise positions of the crystallographic defects, which?enables?defects repair and yield enhancement.展开更多
Introduction: A scanning acoustic microscope (SAM) is an apparatus for imaging acoustic properties. This apparatus can non-invasively and rapidly evaluate the hardness of materials in the elastic region. This device s...Introduction: A scanning acoustic microscope (SAM) is an apparatus for imaging acoustic properties. This apparatus can non-invasively and rapidly evaluate the hardness of materials in the elastic region. This device shows great potential for the diagnosis of dental caries in the clinical setting. However, since the tissue elastic modulus measured using a SAM is a property of the elastic region and the Knoop hardness is a property of the plastic region, the hardness properties differ completely. Therefore, we investigated whether the acoustic impedance measured using a SAM is related to the Knoop hardness, which is used as the standard for removal of carious dentin. Method: Polished sections were prepared from 20 extracted carious wisdom teeth. The acoustic impedance and Knoop hardness were measured for each section. In addition to comparing carious and healthy dentin in SAM images, we evaluated the difference between the carious and healthy dentin in terms of the acoustic impedance and Knoop hardness. We also evaluated the correlation between the Knoop hardness and acoustic impedance. Results: The SAM images were visualized as two-dimensional color images based on the acoustic impedance values. The mean acoustic impedance of carious dentin was significantly lower than that of healthy dentin, showing a similar trend as Knoop hardness. A strong correlation was observed between the two. Discussion: The acoustic impedance values obtained through acoustic microscopy differed significantly between carious and sound dentin. Both types of dentins were visualized using two-dimensional color images. A strong correlation was observed between the acoustic impedance value, which indicates the hardness of the elastic region, and the Knoop hardness, which indicates the hardness of the plastic region. The results of the present study indicate that acoustic impedance accurately reflects the hardness of dentin.展开更多
AIM To image stomach wall blood vessels and tissue, layerby-layer.METHODS We built up the acoustic resolution photoacoustic microscopy(AR-PAM) system for imaging layered tissues, such as the stomach wall. A tunable dy...AIM To image stomach wall blood vessels and tissue, layerby-layer.METHODS We built up the acoustic resolution photoacoustic microscopy(AR-PAM) system for imaging layered tissues, such as the stomach wall. A tunable dye laser system was coupled to a fiber bundle. The fibers of the bundle were placed in nine directions with an incident angle of 45° around a high-frequency ultrasound transducer attached to the acoustic lens. This structure formed a dark field on the tissue surface under the acoustic lens and the nine light beams from the fibers to be combined near the focal point of the acoustic lens. The sample piece was cut from a part of the porcine stomach into a petri dish. In order to realize photoacoustic depth imaging of tumor, we designed a tumor model based on indocyanine green(ICG) dye. The ICG solution(concentration of 129 μM/m L)was mixed into molten gel, and then a gel mixture of ICG(concentration of 12.9 μM/mL) was injected into the stomach submucosa. The injection quantity was controlled by 0.1 mL to make a small tumor model. RESULTS An acoustic resolution photoacoustic microscopy based on fiber illumination was established and an axial resolution of 25 μm and a lateral resolution of 50 μm in its focal zone range of 500 μm has been accomplished. We tuned the laser wavelength to 600 nm. The photoacoustic probe was driven to do B-scan imaging in tissue thickness of 200 μm. The photoacoustic micro-image of mucosa and submucosa of the tissue have been obtained and compared with a pathological photograph of the tissue stained by hematoxylin-eosin staining. We have observed more detailed internal structure of the tissue. We also utilized this photoacoustic microscopy to image blood vessels inside the submucosa. High contrast imaging of the submucosa tumor model was obtained using ICG dye. CONCLUSION This AR-PAM is able to image layer-by-layer construction and some blood vessels under mucosa in the stomach wall without any contrast agents.展开更多
Simultaneous photoacoustic and ultrasound(PAUS)imaging has attracted increasing attention in biomedical research to probe the optical and mechanical properties of tissue.However,the resolution for majority of the exis...Simultaneous photoacoustic and ultrasound(PAUS)imaging has attracted increasing attention in biomedical research to probe the optical and mechanical properties of tissue.However,the resolution for majority of the existing PAUS systems is on the order of 1 mm as the majority are designed for clinical use with low-frequency US detection.Here we developed a concurrent PAUS microscopy that consists of optical-resolution photoacoustic microscopy(OR-PAM)and high-frequency US pulse-echo imaging.This dual-modality system utilizes a novel coaxial dual-element ultrasonic transducer(DE-UST)and provides anatomical and functional information with complementary contrast mechanisms,achieving a spatial resolution of 7μm for PA imaging and 106μm for US imaging.We performed phantom studies to validate the system’s performance.The vasculature of a mouse’s hind paw was imaged to demonstrate the potential of this hybrid system for biomedical applications.展开更多
Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and...Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing.展开更多
Optical microscopy promises researchers to soe most tiny substances directly.However,the resolution of conventional microscopy is resticted by the diffraction limit.This makes it a challenge to observe subcellular pro...Optical microscopy promises researchers to soe most tiny substances directly.However,the resolution of conventional microscopy is resticted by the diffraction limit.This makes it a challenge to observe subcellular processes happened in nanoscale.The development of super-resolution microscopy provides a solution to this challenge.Here,we briefly review several commonly used super-resolution techniques,explicating their basic principles and applications in biological science,especially in neuroscience.In addition,characteristics and limitations of each techrique are compared to provide a guidance for biologists to choose the most suitable tool.展开更多
The nucleation and growth mechanism of nanoparticles is an important theory,which can guide the preparation of nanomaterials.However,it is still lacking in direct observation on the details of the evolution of interme...The nucleation and growth mechanism of nanoparticles is an important theory,which can guide the preparation of nanomaterials.However,it is still lacking in direct observation on the details of the evolution of intermediate state structure during nucleation and growth.In this work,the evolution process of bismuth nanoparticles induced by electron beam was revealed by in-situ transmission electron microscopy(TEM)at atomic scale.The experimental results demonstrate that the size,stable surface and crystallographic defect have important influences on the growth of Bi nanoparticles.Two non-classical growth paths including single crystal growth and polycrystalline combined growth,as well as,corresponding layer-by-layer growth mechanism along{012}stable crystal plane of Bi nanoparticles with dodecahedron structure were revealed by in-situ TEM directly.These results provide important guidance and a new approach for in-depth understanding of the nucleation and growth kinetics of nanoparticles.展开更多
Exploring the realms of physics that extend beyond thermal equilibrium has emerged as a crucial branch of condensed matter physics research.It aims to unravel the intricate processes involving the excitations,interact...Exploring the realms of physics that extend beyond thermal equilibrium has emerged as a crucial branch of condensed matter physics research.It aims to unravel the intricate processes involving the excitations,interactions,and annihilations of quasi-and many-body particles,and ultimately to achieve the manipulation and engineering of exotic non-equilibrium quantum phases on the ultrasmall and ultrafast spatiotemporal scales.Given the inherent complexities arising from many-body dynamics,it therefore seeks a technique that has efficient and diverse detection degrees of freedom to study the underlying physics.By combining high-power femtosecond lasers with real-or momentum-space photoemission electron microscopy(PEEM),imaging excited state phenomena from multiple perspectives,including time,real space,energy,momentum,and spin,can be conveniently achieved,making it a unique technique in studying physics out of equilibrium.In this context,we overview the working principle and technical advances of the PEEM apparatus and the related laser systems,and survey key excited-state phenomena probed through this surface-sensitive methodology,including the ultrafast dynamics of electrons,excitons,plasmons,spins,etc.,in materials ranging from bulk and nano-structured metals and semiconductors to low-dimensional quantum materials.Through this review,one can further envision that time-resolved PEEM will open new avenues for investigating a variety of classical and quantum phenomena in a multidimensional parameter space,offering unprecedented and comprehensive insights into important questions in the field of condensed matter physics.展开更多
Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously anal...Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution.展开更多
Wireless information and power transfer(WIPT) enables simultaneously communications and sustainable power supplement without the erection of power supply lines and the replacement operation of the batteries for the te...Wireless information and power transfer(WIPT) enables simultaneously communications and sustainable power supplement without the erection of power supply lines and the replacement operation of the batteries for the terminals. The application of WIPT to the underwater acoustic sensor networks(UWASNs) not only retains the long range communication capabilities, but also provides an auxiliary and convenient energy supplement way for the terminal sensors, and thus is a promising scheme to solve the energy-limited problem for the UWASNs. In this paper, we propose the integration of WIPT into the UWASNs and provide an overview on various enabling techniques for the WIPT based UWASNs(WIPT-UWASNs) as well as pointing out future research challenges and opportunities for WIPT-UWASNs.展开更多
Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwi...Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwide.GC is most frequent in males and is believed to arise from a series of premalignant lesions.The detection of GC at an early stage is crucial because early GC,which is an invasive stomach cancer confined to the mucosal or submucosal lining,may be curable with a reported 5-year survival rate of more than 90%.Advanced GC usually has a poor prognosis despite current treatment standards.The diagnostic efficacy of conventional endoscopy(with light endoscopy)is currently limited.Confocal laser endomicroscopy is a novel imaging technique that allows real-time in vivo histological examination of mucosal surfaces during endoscopy.Confocal laser endomicroscopy may be of great importance in the surveillance of precancerous gastric lesions and in the diagnosis of GC.In this editorial we commented on the article about this topic published by Lou et al in the recent issue of the World Journal of Clinical Cases.展开更多
We demonstrate the feasibility of simultancous multi-probe detection for an optcal-resolution photoacoustic microscopy(OR-PAM)system.OR-P AM has elicited the attention of biomedical imaging researchers because of its ...We demonstrate the feasibility of simultancous multi-probe detection for an optcal-resolution photoacoustic microscopy(OR-PAM)system.OR-P AM has elicited the attention of biomedical imaging researchers because of its optical absorption contrast and high spatial resolution with great imaging depth.OR-PAM allows label-free and noninvasive imaging by maximizing the optical absorption of endogenous biomolecules.However,given the inadequate absoption of some biomolcules,detection sensitivity at the same incident intensity requires improvement.In this study,a modulated continuous wave with power density less than 3mW/cm^(2)(1/4 of the ANSI safety limit)excited the weak photoacoustic(PA)signals of biological cells.A microcavity traneducer is developed based on the bulk modulus of gas five orders of magnitude lower than that of solid;air pressure variation is inversely proportional to cavity volume at the same temperature increase.Considering that a PA wave expands in various directions,detecting PA signals from different positions and adding them together can increase detection sensitivity and signal-to-noise ratio.Therefore,we employ four detectors to acquire tiny PA signals simul-taneously.Experimental results show that the developed OR-PAM system allows the label-free imaging of cells with weak optical absorption.展开更多
[Objective] The aim was to study the effects of different acoustic frequency of insect sound (IS) and insect-music mixed sound (MS) treatment on the growth of 6 kinds of vegetables.[Method] The insect acoustic gro...[Objective] The aim was to study the effects of different acoustic frequency of insect sound (IS) and insect-music mixed sound (MS) treatment on the growth of 6 kinds of vegetables.[Method] The insect acoustic group,insect-music mixed group and normal control group were designed to determine the related indices of 6 kinds of vegetables in unified management regularly.[Result] After different acoustic frequency treatment,besides soybean plant height,dry root weight of cabbage and greengrocery,there was significant difference of plant height,fresh weight and dry weight between the other vegetables and control.Under acoustic frequency treatment,the growth situations of six kinds of vegetables were better than control.In the growth period,acoustic frequency treatment could promote height growth (except soybean) and edible part yield.[Conclusion] Both of IS and MS could promote the plant growth,but their effects had difference.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.12027808,11874217,11834008,81900875,and 81770973)Natural Science Foundation of Jiangsu Province,China(Grant No.BK 20181077)。
文摘Photoacoustic imaging is a potential candidate for in vivo brain imaging,whereas,its imaging performance could be degraded by inhomogeneous multi-layered media,consisted of scalp and skull.In this work,we propose a low-artifact photoacoustic microscopy(LAPAM)scheme,which combines conventional acoustic-resolution photoacoustic microscopy with scanning acoustic microscopy to suppress the reflection artifacts induced by multi-layers.Based on similar propagation characteristics of photoacoustic signals and ultrasonic echoes,the ultrasonic echoes can be employed as the filters to suppress the reflection artifacts to obtain low-artifact photoacoustic images.Phantom experiment is used to validate the effectiveness of this method.Furthermore,LAPAM is applied for in-vivo imaging mouse brain without removing the scalp and the skull.Experimental results show that the proposed method successfully achieves the low-artifact brain image,which demonstrates the practical applicability of LAPAM.This work might improve the photoacoustic imaging quality in many biomedical applications which involve tissues with complex acoustic properties,such as brain imaging through scalp and skull.
基金Project supported by the National Natural Science Foundation of China(Grant No.50775005)
文摘In this paper the elastic properties of SiOx film are investigated quantitatively for local fixed point and qualitatively for overall area by atomic force acoustic microscopy (AFAM) in which the sample is vibrated at the ultrasonic frequency while the sample surface is touched and scanned with the tip contacting the sample respectively for fixed point and continuous measurements. The SiOx films on the silicon wafers are prepared by the plasma enhanced chemical vapour deposition (PECVD), The local contact stiffness of the tip-SiOx film is calculated from the contact resonance spectrum measured with the atomic force acoustic microscopy. Using the reference approach, indentation modulus of SiOx film for fixed point is obtained. The images of cantilever amplitude are also visualized and analysed when the SiOx surface is excited at a fixed frequency. The results show that the acoustic amplitude images can reflect the elastic properties of the sample.
基金supported by University of Macao,China,Nos.MYRG2022-00054-FHS and MYRG-GRG2023-00038-FHS-UMDF(to ZY)the Macao Science and Technology Development Fund,China,Nos.FDCT0048/2021/AGJ and FDCT0020/2019/AMJ and FDCT 0011/2018/A1(to ZY)Natural Science Foundation of Guangdong Province of China,No.EF017/FHS-YZ/2021/GDSTC(to ZY)。
文摘To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes.
文摘C-mode scanning acoustical microscopy, C-SAM, is widely used in plastic package evaluations and for failure analysis. It permits to detect subsurface delaminations, cracks and pores (air bubbles) for different microelectronics packages. In this study, abnormality was observed in C-SAM daily test, the images showed no delaminations but inhomogeneities on the IC surface. Corrosion was found by optical microscope and scanning electron microscope after decapsulation. It can be revealed as the acoustic impedance is different between corrosion and normal area. The presence of inhomogeneities and discontinuities along ultrasonic waves' propagation paths inside the matter causes modifications in the amplitude and polarity of ultrasonic waves. However, C-SAM's capability in detecting IC surface corrosion has not been presented. The capability will be illustrated and the inspection mechanism will be discussed in this paper.
基金supported by National Natural Science Foundation of China(Grant No. 50775005)General Program of Science and Technology Development Project of Beijing Municipal Education Commission(Grant No. KM201110015009)
文摘Traditional technique such nanoindenter(NI) can't measure the local elastic modulus at nano-scale(lateral). Atomic force acoustic microscopy (AFAM) is a dynamic method, which can quantitatively determine indentation modulus by measuring the contact resonance spectra for high order modes of the cantilever. But there are few reports on the effect of experimental factors, such length of cantilever, contact stiffness on measured value. For three different samples, including copper(Cu) film with 110 nm thickness, zinc(Zn) film of 90 nm thickness and glass slides, are prepared and tested, using referencing approach in which measurements are performed on the test and reference samples (it's elastic modulus is known), and their contact resonance spectra are measured used the AFAM system experimentally. According to the vibration theory, from the lowest two contact resonance frequencies, the tip-sample contact stiffness is calculated, and then the values for the elastic properties of test sample, such as the indentation modulus, are determined. Using AFAM system, the measured indentation modulus of copper nano-film, zinc nano-film and glass slides are 113.53 GPa, 87.92 GPa and 57.04 GPa, which are agreement with literature values Mcu--105-130 GPa, Mzn = 88.44 GPa and Molass = 50-90 GPa. Furthermore, the sensitivity of contact resonance frequency to contact stiffness is analyzed theoretically. The results show that for the cantilevers with the length 160 pm, 225 μm and 520 μm respectively, when contact stiffness increases from 400 N/m to 600 N/m, the increments of first contact resonance frequency are 126 kHz, 93 kHz and 0.6 kHz, which show that the sensitivity of the contact resonance frequency to the contact stiffness reduces with the length of cantilever increasing. The novel method presented can characterize elastic modulus of near surface for nano-film and bulk material, and local elasticity of near surface can be evaluated by optimizing the experimental parameters using the AFAM system.
文摘Aims: Dilated cardiomyopathy often shows left ventricular systolic dysfunction, although histologically it always exhibits non-specific abnormality. We hypothesized that myocyte sound speed might be altered due to incomplete protein accumulation in cells. Methods and Results: Ninety eight biopsied samples were obtained from 49 patients comprising 43 with clinical dilated cardiomyopathy and 6 with hypertrophic cardiomyopathy. Sound speed was evaluated in deparaffinized 10 μm thick sections using an acoustic microscope (frequency range: 50 - 105 MHz). Conventional histology revealed 7 cases of persistent myocarditis derived from clinical dilated cardio- myopathy samples. Histology of the remaining dilated cardiomyopathy patients indicated non-specific abnormality. All hypertrophic cardiomyopathy cases exhibited myocardial disarray. Ten normal autopsied hearts were compared as controls. The sound speed of controls was 1627 ± 30m/sec. The sound speed in dilated cardiomyopathy samples (1700 ±51m/sec) was 1.045-fold faster compared to controls. The sound speed in hypertrophic cardiomyopathy samples (1734 ±51m/sec, 1.066-fold compared to controls) was faster than that of the myocarditis group (1672 ±30m/sec, 1.028-fold) (P = 0.0218). Furtheremore, desmin expression was evaluated as extent of emergence (grading 0 - 4). The desmin expression score in hypertrophic cardiomyopathy samples (2.7 ± 0.8) was significantly higher than in other groups (dilated 2.0 ± 1.4, myocarditis 1.6 ± 1.5 vs., controls 0, P ≤ 0.0001, 0.0001, 0.0129, respectively). Conclusion: Cardio-myopathy enhanced the sound speed, which correlated with the elasticity of myocytes, following the impaired compliance of left ventricle, despite the absence of histological changes. The elevation of sound speed of myocytes may be linked to cytoskeletal changes. Myocyte sound speed may be a new diagnostic tool for diagnosis of idiopathic cardiomyopathy independently of conventional histological diagnosis.
文摘In this work, C-Scan Acoustic Scanning Microscopy (ASM) is used to map the defects of three SiC samples. The acoustic images indicate that numerous defects with different shapes and area?sexist in the wafers. Some of the defects have areas of more than 100,000 μm2. The number of defects ranges from 1 to 50 defects/wafer. Defect mapping is essential for defect repairing or avoidance.?This work shows that ASM can locate the precise positions of the crystallographic defects, which?enables?defects repair and yield enhancement.
文摘Introduction: A scanning acoustic microscope (SAM) is an apparatus for imaging acoustic properties. This apparatus can non-invasively and rapidly evaluate the hardness of materials in the elastic region. This device shows great potential for the diagnosis of dental caries in the clinical setting. However, since the tissue elastic modulus measured using a SAM is a property of the elastic region and the Knoop hardness is a property of the plastic region, the hardness properties differ completely. Therefore, we investigated whether the acoustic impedance measured using a SAM is related to the Knoop hardness, which is used as the standard for removal of carious dentin. Method: Polished sections were prepared from 20 extracted carious wisdom teeth. The acoustic impedance and Knoop hardness were measured for each section. In addition to comparing carious and healthy dentin in SAM images, we evaluated the difference between the carious and healthy dentin in terms of the acoustic impedance and Knoop hardness. We also evaluated the correlation between the Knoop hardness and acoustic impedance. Results: The SAM images were visualized as two-dimensional color images based on the acoustic impedance values. The mean acoustic impedance of carious dentin was significantly lower than that of healthy dentin, showing a similar trend as Knoop hardness. A strong correlation was observed between the two. Discussion: The acoustic impedance values obtained through acoustic microscopy differed significantly between carious and sound dentin. Both types of dentins were visualized using two-dimensional color images. A strong correlation was observed between the acoustic impedance value, which indicates the hardness of the elastic region, and the Knoop hardness, which indicates the hardness of the plastic region. The results of the present study indicate that acoustic impedance accurately reflects the hardness of dentin.
基金Supported by the National Nature Science Foundation of China,No.61378060
文摘AIM To image stomach wall blood vessels and tissue, layerby-layer.METHODS We built up the acoustic resolution photoacoustic microscopy(AR-PAM) system for imaging layered tissues, such as the stomach wall. A tunable dye laser system was coupled to a fiber bundle. The fibers of the bundle were placed in nine directions with an incident angle of 45° around a high-frequency ultrasound transducer attached to the acoustic lens. This structure formed a dark field on the tissue surface under the acoustic lens and the nine light beams from the fibers to be combined near the focal point of the acoustic lens. The sample piece was cut from a part of the porcine stomach into a petri dish. In order to realize photoacoustic depth imaging of tumor, we designed a tumor model based on indocyanine green(ICG) dye. The ICG solution(concentration of 129 μM/m L)was mixed into molten gel, and then a gel mixture of ICG(concentration of 12.9 μM/mL) was injected into the stomach submucosa. The injection quantity was controlled by 0.1 mL to make a small tumor model. RESULTS An acoustic resolution photoacoustic microscopy based on fiber illumination was established and an axial resolution of 25 μm and a lateral resolution of 50 μm in its focal zone range of 500 μm has been accomplished. We tuned the laser wavelength to 600 nm. The photoacoustic probe was driven to do B-scan imaging in tissue thickness of 200 μm. The photoacoustic micro-image of mucosa and submucosa of the tissue have been obtained and compared with a pathological photograph of the tissue stained by hematoxylin-eosin staining. We have observed more detailed internal structure of the tissue. We also utilized this photoacoustic microscopy to image blood vessels inside the submucosa. High contrast imaging of the submucosa tumor model was obtained using ICG dye. CONCLUSION This AR-PAM is able to image layer-by-layer construction and some blood vessels under mucosa in the stomach wall without any contrast agents.
文摘Simultaneous photoacoustic and ultrasound(PAUS)imaging has attracted increasing attention in biomedical research to probe the optical and mechanical properties of tissue.However,the resolution for majority of the existing PAUS systems is on the order of 1 mm as the majority are designed for clinical use with low-frequency US detection.Here we developed a concurrent PAUS microscopy that consists of optical-resolution photoacoustic microscopy(OR-PAM)and high-frequency US pulse-echo imaging.This dual-modality system utilizes a novel coaxial dual-element ultrasonic transducer(DE-UST)and provides anatomical and functional information with complementary contrast mechanisms,achieving a spatial resolution of 7μm for PA imaging and 106μm for US imaging.We performed phantom studies to validate the system’s performance.The vasculature of a mouse’s hind paw was imaged to demonstrate the potential of this hybrid system for biomedical applications.
文摘Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing.
基金support from National Basic Research Program of China (973 Program) (2015CB352005)National Natural Science Foundation of China (No.6142780065,31571110,81527901)+1 种基金Natural Science Foundation of Zhejiang Province of China (No.Y16F050002)the Fundamental Research Funds for the Central Universities.
文摘Optical microscopy promises researchers to soe most tiny substances directly.However,the resolution of conventional microscopy is resticted by the diffraction limit.This makes it a challenge to observe subcellular processes happened in nanoscale.The development of super-resolution microscopy provides a solution to this challenge.Here,we briefly review several commonly used super-resolution techniques,explicating their basic principles and applications in biological science,especially in neuroscience.In addition,characteristics and limitations of each techrique are compared to provide a guidance for biologists to choose the most suitable tool.
基金Funded by the National Natural Science Foundation of China(No.52103285)the 111 National Project(No.B20002)。
文摘The nucleation and growth mechanism of nanoparticles is an important theory,which can guide the preparation of nanomaterials.However,it is still lacking in direct observation on the details of the evolution of intermediate state structure during nucleation and growth.In this work,the evolution process of bismuth nanoparticles induced by electron beam was revealed by in-situ transmission electron microscopy(TEM)at atomic scale.The experimental results demonstrate that the size,stable surface and crystallographic defect have important influences on the growth of Bi nanoparticles.Two non-classical growth paths including single crystal growth and polycrystalline combined growth,as well as,corresponding layer-by-layer growth mechanism along{012}stable crystal plane of Bi nanoparticles with dodecahedron structure were revealed by in-situ TEM directly.These results provide important guidance and a new approach for in-depth understanding of the nucleation and growth kinetics of nanoparticles.
基金Project supported by the National Natural Science Foundation of China(Grant No.12374223)Shenzhen Science and Technology Program(Grant No.20231117151322001).
文摘Exploring the realms of physics that extend beyond thermal equilibrium has emerged as a crucial branch of condensed matter physics research.It aims to unravel the intricate processes involving the excitations,interactions,and annihilations of quasi-and many-body particles,and ultimately to achieve the manipulation and engineering of exotic non-equilibrium quantum phases on the ultrasmall and ultrafast spatiotemporal scales.Given the inherent complexities arising from many-body dynamics,it therefore seeks a technique that has efficient and diverse detection degrees of freedom to study the underlying physics.By combining high-power femtosecond lasers with real-or momentum-space photoemission electron microscopy(PEEM),imaging excited state phenomena from multiple perspectives,including time,real space,energy,momentum,and spin,can be conveniently achieved,making it a unique technique in studying physics out of equilibrium.In this context,we overview the working principle and technical advances of the PEEM apparatus and the related laser systems,and survey key excited-state phenomena probed through this surface-sensitive methodology,including the ultrafast dynamics of electrons,excitons,plasmons,spins,etc.,in materials ranging from bulk and nano-structured metals and semiconductors to low-dimensional quantum materials.Through this review,one can further envision that time-resolved PEEM will open new avenues for investigating a variety of classical and quantum phenomena in a multidimensional parameter space,offering unprecedented and comprehensive insights into important questions in the field of condensed matter physics.
基金supported by National Key R&D Program of China(grant no.2022YFC2404201)the Chinese Academy of Sciences Project for Young Scientists in Basic Research(grant no.YSBR067).
文摘Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution.
基金supported in part by the National Natural Science Foundation of China under Grant 62171187the Guangdong Basic and Applied Basic Research Foundation under Grant 2022A1515011476+1 种基金the Science and Technology Program of Guangzhou under Grant 201904010373the Key Program of Marine Economy Development (Six Marine Industries) Special Foundation of Department of Natural Resources of Guangdong Province (GDNRC [2020]009)。
文摘Wireless information and power transfer(WIPT) enables simultaneously communications and sustainable power supplement without the erection of power supply lines and the replacement operation of the batteries for the terminals. The application of WIPT to the underwater acoustic sensor networks(UWASNs) not only retains the long range communication capabilities, but also provides an auxiliary and convenient energy supplement way for the terminal sensors, and thus is a promising scheme to solve the energy-limited problem for the UWASNs. In this paper, we propose the integration of WIPT into the UWASNs and provide an overview on various enabling techniques for the WIPT based UWASNs(WIPT-UWASNs) as well as pointing out future research challenges and opportunities for WIPT-UWASNs.
文摘Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwide.GC is most frequent in males and is believed to arise from a series of premalignant lesions.The detection of GC at an early stage is crucial because early GC,which is an invasive stomach cancer confined to the mucosal or submucosal lining,may be curable with a reported 5-year survival rate of more than 90%.Advanced GC usually has a poor prognosis despite current treatment standards.The diagnostic efficacy of conventional endoscopy(with light endoscopy)is currently limited.Confocal laser endomicroscopy is a novel imaging technique that allows real-time in vivo histological examination of mucosal surfaces during endoscopy.Confocal laser endomicroscopy may be of great importance in the surveillance of precancerous gastric lesions and in the diagnosis of GC.In this editorial we commented on the article about this topic published by Lou et al in the recent issue of the World Journal of Clinical Cases.
基金supported by the National Natural Science Foundation of China(Grant No.61178086)Science and Technology Program of Guangzhou,China(Grant No.2012J4300138)Foundation for Distinguished Young Talents in South China Normal University,China.(Grant No.2012KJ010).
文摘We demonstrate the feasibility of simultancous multi-probe detection for an optcal-resolution photoacoustic microscopy(OR-PAM)system.OR-P AM has elicited the attention of biomedical imaging researchers because of its optical absorption contrast and high spatial resolution with great imaging depth.OR-PAM allows label-free and noninvasive imaging by maximizing the optical absorption of endogenous biomolecules.However,given the inadequate absoption of some biomolcules,detection sensitivity at the same incident intensity requires improvement.In this study,a modulated continuous wave with power density less than 3mW/cm^(2)(1/4 of the ANSI safety limit)excited the weak photoacoustic(PA)signals of biological cells.A microcavity traneducer is developed based on the bulk modulus of gas five orders of magnitude lower than that of solid;air pressure variation is inversely proportional to cavity volume at the same temperature increase.Considering that a PA wave expands in various directions,detecting PA signals from different positions and adding them together can increase detection sensitivity and signal-to-noise ratio.Therefore,we employ four detectors to acquire tiny PA signals simul-taneously.Experimental results show that the developed OR-PAM system allows the label-free imaging of cells with weak optical absorption.
基金Supported by Important Project of Science and Technology of Zhejiang Province(2008C12056)~~
文摘[Objective] The aim was to study the effects of different acoustic frequency of insect sound (IS) and insect-music mixed sound (MS) treatment on the growth of 6 kinds of vegetables.[Method] The insect acoustic group,insect-music mixed group and normal control group were designed to determine the related indices of 6 kinds of vegetables in unified management regularly.[Result] After different acoustic frequency treatment,besides soybean plant height,dry root weight of cabbage and greengrocery,there was significant difference of plant height,fresh weight and dry weight between the other vegetables and control.Under acoustic frequency treatment,the growth situations of six kinds of vegetables were better than control.In the growth period,acoustic frequency treatment could promote height growth (except soybean) and edible part yield.[Conclusion] Both of IS and MS could promote the plant growth,but their effects had difference.