期刊文献+
共找到67,565篇文章
< 1 2 250 >
每页显示 20 50 100
Surgical Management of Lumbar Spinal Canal Stenosis with Instrumentation at the Yaounde Central Hospital: Comparison of Unilateral versus Bilateral Pedicle Screw Fixation Combined with Transforaminal Lumbar Interbody Fusion
1
作者 Orlane Toto Ndome Nassourou Oumarou Haman +4 位作者 Dimitri Fogue Jean Bruno Ndoumou Ronaldo Fonju Anu Indira Baboke Vincent De Paul Djientcheu 《Open Journal of Modern Neurosurgery》 2024年第3期179-189,共11页
Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed co... Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed comparing the clinical effectiveness of unilateral versus bilateral fixation in the surgical management of lumbar spinal canal stenosis. Objective: Evaluate the impact on quality of life and clinical efficacy of unilateral spondylodesis compared to bilateral spondylodesis in the surgical management of lumbar spinal canal stenosis at the Yaounde Central Hospital. Methods: This was a retrospective descriptive cross-sectional study for a period of 4 years, from June 2015 to June 2019. It involved all patients operated for lumbar canal stenosis and who underwent spondylodesis or spinal fusion at the neurosurgery department of the Yaounde Central Hospital. Results: A total of 68 participants were recruited during our study period. 32 (47%) of the study population were in the 50 - 60 age group, with a mean age of 56.98 years ranging from 41 to 75 years. Females, housewives and farmers were the most affected. In our study, 72% of patients had unilateral spondylodesis and 28% had bilateral fusion. Preoperatively, 71% of patients had insurmountable pain, refractory to medical treatment. At 3 months postoperatively, 73.7% of patients with bilateral setup had moderate pain compared to 69% of those with unilateral setup. At 6 months postoperatively, 79% of patients with bilateral fusion had mild pain compared to 82% of patients with unilateral setup. At 1 year postoperatively, all patients had mild pain. Preoperatively, 66.2% of patients were unable to walk and 19.1% of patients were bedridden according to the Oswestry score. At 3 months postoperatively, 10.2% of patients with unilateral setup were unable to walk compared to 10.5% of patients with bilateral fixation, while 67.3% of patients with unilateral fixation had moderate disability compared to 52.6% of patients with bilateral fixation. At 6 months postoperatively, 51% of patients with unilateral setup had moderate disability compared to 47.4% of patients with bilateral fixation, while 42.9% of patients with unilateral fixation had mild disability compared to 42.1% of patients with bilateral fixation. At 1 year postoperatively, 81.6% of patients who underwent unilateral fixation had only mild disability compared to 73.7% of patients with bilateral fixation. Conclusion: The assessment of quality of life according to the set-up used shows similar results at 3 months, 6 months and 1 year, with no statistically significant differences. Single-sided pedicle screw fixation combined with transforaminal lumbar interbody fusion or mounting has the advantage of being faster, with less bleeding and is less expensive compared to bilateral fixation. 展开更多
关键词 Lumbar Spinal Canal STENOSIS instrumentation Surgery Quality of Life
下载PDF
A promising approach for quantifying focal stroke modeling and assessing stroke progression:optical resolution photoacoustic microscopy photothrombosis
2
作者 Xiao Liang Xingping Quan +6 位作者 Xiaorui Geng Yujing Huang Yonghua Zhao Lei Xi Zhen Yuan Ping Wang Bin Liu 《Neural Regeneration Research》 SCIE CAS 2025年第7期2029-2037,共9页
To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these me... To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes. 展开更多
关键词 AGE-DEPENDENT cerebral cortex ischemic stroke mouse model optical coherence tomography angiography photoacoustic microscopy PHOTOTHROMBOSIS vascular imaging
下载PDF
A New Electronic Instrumentation Approach for the Acquisition of Microscopic Blood Smear Images for the Automatic Diagnosis of Anemia
3
作者 Jerome Nango Alico Sié Ouattara Alain Clement 《Advances in Bioscience and Biotechnology》 2020年第6期237-255,共19页
Anemia is a blood abnormality that affects the quantity and quality of red blood cells in the human body. This sometimes banal sign spares no continent and no social stratum. This anomaly is generally appreciated thro... Anemia is a blood abnormality that affects the quantity and quality of red blood cells in the human body. This sometimes banal sign spares no continent and no social stratum. This anomaly is generally appreciated through biological analyzes of patients</span><span style="font-family:Verdana;">’</span><span style="font-family:Verdana;"> blood. These analyzes, which boil down to the knowledge of hemato-metric constants, cannot by themselves allow the characterization of certain forms of anemia in the sense that most anemia are related to the morphology and color of red blood cells. Our work in this paper is to perform blood smears on patients and perform a morphological and colorimetric analysis of red blood cells on these smears. This approach allowed us to highlight on each erythrocyte morphological and colorimetric descriptors to accurately identify the types of anemia by image processing methods. This identification is performed in an automated environment to allow pathologists to respond quickly to anemia-related emergencies and also improve the treatment to be conducted. This automation required the implementation of a new approach to electronic instrumentation and the acquisition of microscopic blood smear images for the automatic and rapid diagnosis of anemia. 展开更多
关键词 ANEMIA instrumentation ACQUISITION Automated Blood Smears Red Blood Cells Morphological Descriptors Colorimetric Descriptors Image Processing Diagnosis
下载PDF
Computerised tomography vs magnetic resonance imaging for modeling of patient-specific instrumentation in total knee arthroplasty 被引量:3
4
作者 Paul Stirling Rejith Valsalan Mannambeth +3 位作者 Agustin Soler Vineet Batta Rajeev Kumar Malhotra Yegappan Kalairajah 《World Journal of Orthopedics》 2015年第2期290-297,共8页
AIM: To summarise and compare currently available evidence regarding accuracy of pre-operative imaging, which is one of the key choices for surgeons contemplating patient-specific instrumentation(PSI) surgery.METHODS:... AIM: To summarise and compare currently available evidence regarding accuracy of pre-operative imaging, which is one of the key choices for surgeons contemplating patient-specific instrumentation(PSI) surgery.METHODS: The MEDLINE and EMBASE medical literature databases were searched, from January 1990 to December 2013, to identify relevant studies. The data from several clinical studies was assimilated to allow appreciation and comparison of the accuracy of each modality. The overall accuracy of each modality was calculated as proportion of outliers > 3% in the coronal plane of both computerised tomography(CT) or magnetic resonance imaging(MRI). RESULTS: Seven clinical studies matched our inclusion criteria for comparison and were included in our study for statistical analysis. Three of these reported series using MRI and four with CT. Overall percentage of outliers > 3% in patients with CT-based PSI systems was 12.5% vs 16.9% for MRI-based systems. These results were not statistically significant. CONCLUSION: Although many studies have been undertaken to determine the ideal pre-operative imaging modality, conclusions remain speculative in the absence of long term data. Ultimately, information regarding accuracy of CT and MRI will be the main determining factor. Increased accuracy of pre-operative imaging could result in longer-term savings, and reduced accumulated dose of radiation by eliminating the need for post-operative imaging and revision surgery. 展开更多
关键词 PATIENT-SPECIFIC instrumentation ARTHROPLASTY ALIGNMENT Accuracy COST-EFFECTIVENESS
下载PDF
Current concepts in total knee arthroplasty: Patient specific instrumentation 被引量:3
5
作者 Patrick Sadoghi 《World Journal of Orthopedics》 2015年第6期446-448,共3页
Patient specific instrumentation(PSI) in total knee arthroplasty(TKA) promises faster operation time(by using less instruments and individual cutting jigs), less blood loss, faster rehabilitation, better implant sizin... Patient specific instrumentation(PSI) in total knee arthroplasty(TKA) promises faster operation time(by using less instruments and individual cutting jigs), less blood loss, faster rehabilitation, better implant sizing and accuracy, superior overall outcome, and at the end- less costs. However, as evident for every new development, its superiority remains to be provenover the conventional systems. Whilst dissatisfaction is reported to be eminent in up to 30% of patients having undergone conventional TKA, it is unclear, whether PSI can address to these patients as a suitable option in the future. The author believes that the current evidence does not support superiority of PSI in TKA over conventional systems. However, future long-term level I and II studies might aid to show its cost-effectiveness stating same results, accuracy, and overall outcome with less operation time. 展开更多
关键词 Total KNEE ARTHROPLASTY PATIENT SPECIFIC instrumentation Accuracy Outcome analysis COSTEFFECTIVENESS
下载PDF
Evaluation of behaviors of earth and rockfill dams during construction and initial impounding using instrumentation data and numerical modeling 被引量:2
6
作者 Mohammad Rashidi S. Mohsen Haeri 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2017年第4期709-725,共17页
In this study,the behavior of Gavoshan dam was evaluated during construction and the first impounding.A two-dimensional(2D) numerical analysis was conducted based on a finite difference method on the largest cross-s... In this study,the behavior of Gavoshan dam was evaluated during construction and the first impounding.A two-dimensional(2D) numerical analysis was conducted based on a finite difference method on the largest cross-section of the dam using the results of instrument measurements and back analysis.These evaluations will be completed in the case that back analysis is carried out in order to control the degree of the accuracy and the level of confidence of the measured behavior since each of the measurements could be controlled by comparing it to the result obtained from the numerical model.Following that,by comparing the results of the numerical analysis with the measured values,it is indicated that there is a proper consistency between these two values.Moreover,it was observed that the dam performance was suitable regarding the induced pore water pressure,the pore water pressure ratio r;,settlement,induced stresses,arching degree,and hydraulic fracturing probability during the construction and initial impounding periods.The results demonstrated that the maximum settlement of the core was 238 cm at the end of construction.In the following 6 years after construction(initial impounding and exploitation period),the accumulative settlement of the dam was 270 cm.It is clear that 88% of the total settlement of the dam took place during dam construction.The reason is that the clay core was smashed in the wet side,i.e.the optimum moisture content.Whereas the average curving ratio was 0.64 during dam construction; at the end of the initial impounding,the maximum amount of curving ratio in the upstream was 0.81,and the minimum(critical) amount in the downstream was 0.52.It was also concluded that this dam is safe in comparison with the behaviors of other similar dams in the world. 展开更多
关键词 Earth and rockfill dams Initial impounding Numerical modeling instrumentation SETTLEMENT Pore pressure
下载PDF
Performance evaluation methods and instrumentation for mine ventilation fans 被引量:7
7
作者 LI Man WANG Xue-rong 《Mining Science and Technology》 EI CAS 2009年第6期819-823,共5页
Ventilation fans are one of the most important pieces of equipment in coal mines. Their performance plays an important role in the safety of staff and production. Given the actual requirements of coal mine production,... Ventilation fans are one of the most important pieces of equipment in coal mines. Their performance plays an important role in the safety of staff and production. Given the actual requirements of coal mine production,we instituted a research project on the measurement methods of key performance parameters such as wind pressure,amount of ventilation and power. At the end a virtual instrument for mine ventilation fans performance evaluation was developed using a USB interface. The practical performance and analytical results of our experiments show that it is feasible,reliable and effective to use the proposed instrumentation for mine ventilation performance evaluation. 展开更多
关键词 mine ventilation fan performance evaluation virtual instrument
下载PDF
Intra-operative computed tomography guided navigation for pediatric pelvic instrumentation: A technique guide 被引量:1
8
作者 Jason B Anari Patrick J Cahill +2 位作者 John M Flynn David A Spiegel Keith D Baldwin 《World Journal of Orthopedics》 2018年第10期185-189,共5页
Pelvic instrumentation for neuromuscular scoliosis has been part of neuromuscular scoliosis surgery since the era of the Luque Galveston construct. Unit Rod(Medtronic Sofamor-Danek, Nashville, TN) instrumentation brou... Pelvic instrumentation for neuromuscular scoliosis has been part of neuromuscular scoliosis surgery since the era of the Luque Galveston construct. Unit Rod(Medtronic Sofamor-Danek, Nashville, TN) instrumentation brought with it the concept of cantilever correction by placing the implants in the pelvis and then gradually bringing the rod to the spine by sequentially tightening the sublaminar wires, with the goal of creating a level pelvis over a straight spine. More recently surgeons have utilized pedicle screw constructs in which the corrective strategies have varied. Challenges with pelvic fixation using iliac screws linked to the spinal rod have led to the development of the S2-alariliac technique(S2 AI) in which the spinal rod connects to the pelvic screw. The screw is placed in the S2 ala, crosses the sacro-iliac joint and into the ilium through a large column of supra-acetabular bone. This column is the same area used for anterior inferior iliac spine external fixation frames used in trauma surgery. S2 AI screw placement can be technically difficult and can require experienced radiology technologists to provide the appropriate views. Additionally, although the technique was originally described being placed via freehand technique with intra-operative flouroscopy, the freehand technique suffers from the anatomic anomalies present in the pelvis in neuromuscular scoliosis. As such, we prefer to place them using intra-operative navigation for all pediatric spinal deformity cases. Below in detail we report our intra-operative technique and an illustrative case example. 展开更多
关键词 Posterior instrumentation PEDIATRIC Spinal DEFORMITY Image guidance TECHNIQUE
下载PDF
Recent advances in earthquake monitoring I:Ongoing revolution of seismic instrumentation 被引量:2
9
作者 Zefeng Li 《Earthquake Science》 2021年第2期177-188,共12页
Seismic networks have significantly improved in the last decade in terms of coverage density,data quality,and instrumental diversity.Moreover,revolutionary advances in ultra-dense seismic instruments,such as nodes and... Seismic networks have significantly improved in the last decade in terms of coverage density,data quality,and instrumental diversity.Moreover,revolutionary advances in ultra-dense seismic instruments,such as nodes and fiber-optic sensing technologies,have recently provided unprecedented high-resolution data for regional and local earthquake monitoring.Nodal arrays have characteristics such as easy installation and flexible apertures,but are limited in power efficiency and data storage and thus most suitable as temporary networks.Fiber-optic sensing techniques,including distributed acoustic sensing,can be operated in real time with an in-house power supply and connected data storage,thereby exhibiting the potential of becoming next-generation permanent networks.Fiber-optic sensing techniques offer a powerful way of filling the observation gap particularly in submarine environments.Despite these technological advancements,various challenges remain.First,the data characteristics of fiber-optic sensing are still unclear.Second,it is challenging to construct software infrastructures to store,transfer,visualize,and process large amount of seismic data.Finally,innovative detection methods are required to exploit the potential of numerous channels.With improved knowledge about data characteristics,enhanced software infrastructures,and suitable data processing techniques,these innovations in seismic instrumentation could profoundly impact observational seismology. 展开更多
关键词 earthquake monitoring seismic instrumentation dense array distributed acoustic sensing.
下载PDF
Cost-effectiveness of patient specific vs conventional instrumentation for total knee arthroplasty:A systematic review and meta-analysis 被引量:2
10
作者 Isobel M Dorling Lars Geenen +3 位作者 Marion J L F Heymans Jasper Most Bert Boonen Martijn G M Schotanus 《World Journal of Orthopedics》 2023年第6期458-470,共13页
BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness ... BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness when compared to conventional instrumentation(CI)for TKA.AIM To compare the cost and cost-effectiveness of PSI TKA compared to CI TKA.METHODS A literature search was performed in healthcare,economical healthcare,and medical databases(MEDLINE,EMBASE,CINAHL,Web of Science,Cochrane Library,EconLit).It was conducted in April 2021 and again in January 2022.Relevant literature included randomised controlled trials,retrospective studies,prospective studies,observational studies,and case control studies.All studies were assessed on methodological quality.Relevant outcomes included incremental cost-effectiveness ratio,quality-adjusted life years,total costs,imaging costs,production costs,sterilization associated costs,surgery duration costs and readmission rate costs.All eligible studies were assessed for risk of bias.Meta-analysis was performed for outcomes with sufficient data.RESULTS Thirty-two studies were included into the systematic review.Two were included in the metaanalysis.3994 PSI TKAs and 13267 CI TKAs were included in the sample size.The methodological quality of the included studies,based on Consensus on Health Economic Criteria-scores and risk of bias,ranged from average to good.PSI TKA costs less than CI TKA when considering mean operating room time and its associated costs and tray sterilization per patient case.PSI TKA costs more compared to CI TKA when considering imaging and production costs.Considering total costs per patient case,PSI TKA is more expensive in comparison to CI TKA.Meta-analysis comparing total costs for PSI TKA,and CI TKA showed a significant higher cost for PSI TKA.CONCLUSION Cost for PSI and CI TKA can differ when considering distinct aspects of their implementation.Total costs per patient case are increased for PSI TKA when compared to CI TKA. 展开更多
关键词 Total knee arthroplasty Patient specific instrumentation instrumentation for total knee arthroplasty COST-EFFECTIVENESS Systematic review
下载PDF
ANTERIOR SPINAL FUSION WITH TSRH INSTRUMENTATION FOR SCOLIOSIS 被引量:1
11
作者 沈建雄 赵宏 +5 位作者 邱贵兴 金今 叶启彬 林进 王以朋 翁习生 《Chinese Medical Sciences Journal》 CAS CSCD 2003年第1期41-45,共5页
Objective. To introduce a new spinal internal fixation system, Texas Scottish Rite Hospital (TSRH), and to investigate its early clinical outcomes.Methods. The preliminary clinical outcomes of 15 patients with thoraco... Objective. To introduce a new spinal internal fixation system, Texas Scottish Rite Hospital (TSRH), and to investigate its early clinical outcomes.Methods. The preliminary clinical outcomes of 15 patients with thoracolumbar or lumbar scoliosis treated by anterior spinal fusion with TSRH instrumentation were studied retrospectively. Fourteen patients were diagnosed as idiopathic scoliosis and 1 as neuromuscular scoliosis.Results. Preoperatively, the Cobb's angle on the coronal plane was 55. 8° (range 35° - 78°), and 14° postoperatively, with an average correction of 74. 8 %. The average unfused thoracical curve was 35. 9 ° preoperatively (range 26° - 51°) and 21. 8° (10°-42° ) postoperatively, with 40% correction. The sagittal curve of lumbar was kept physiologically, preoperative 27. 9° and postoperative 25. 7° respectively. The trunk shift was 13.4 mm (5 - 28mm) preoperatively and 3. 5 mm (0-7 mm) postoperatively. The averaged apic vertebra derivation was 47. 8 mm (21 - 69 mm) before operation and 10. 8 mm (3-20 mm) after operation. The distance of C7 to center sacrum vertical line (CSVL) was 19. 5 mm(16 - 42)preoperatively and 11. 3 mm (0-32 mm) postoperatively. The apical vertebra rotation was 3 degree in 15 patients preoperatively, and were improved to normal in 10 patients, 1 degree in 4 patients, and 2 degree in 1 patients postoperatively. None had neurological injury and infection. Only 1 patient complained a cool feeling in the low extremity of concave side, and the symptom vanished at 3-month followed up.Conclusion. If used appropriately, TSRH anterior spinal system is a good treatment for low thoracic or thoracic lumbar scoliosis. 展开更多
关键词 SCOLIOSIS anterior spinal fusion TSRH instrumentation
下载PDF
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION 被引量:1
12
作者 翁习生 仉建国 +6 位作者 邱贵兴 沈建雄 赵宏 金今 王以朋 田野 林进 《Chinese Medical Sciences Journal》 CAS CSCD 2001年第2期98-102,共5页
Objective. To evaluate the results of TSRH instrumentation in the correction of coronal, sagittal and rotational deformity of scoliosis. Methods. From January 1998 to December 1999, thirty- two consecutive patients (6... Objective. To evaluate the results of TSRH instrumentation in the correction of coronal, sagittal and rotational deformity of scoliosis. Methods. From January 1998 to December 1999, thirty- two consecutive patients (6 males, 26 females) with scoliosis underwent anterior or posterior spinal instrumentation and fusion using TSRH instrumentation. Of these cases, 21 were idiopathic scoliosis and 11 were congenital scoliosis. The average age at surgery was 16.4 years (range, 11~ 45 years). The mean Cobb angle at surgery was 71 .2 (range, 44~ 125 ) in the coronal plane, and 49.2 ( range, 16~ 67 ) in the sagittal plane. Rotational deformity (Nash- Moe) ranged from I to III degree. Preoperative apical translation averaged 4.8 cm (range, 3~ 9 cm). Results. The average follow- up duration was 13.3 months (range, 10~ 24 months).At the final follow- up, the mean Cobb angle in the coronal plane was 26. 6 (range, 10~ 73 ),with a 63.8% of improvement. Sagittal alignment was well maintained with a mean Cobb angle of 28 ( range, 10~ 45 ). The average correction of rotation of the apical vertebra was I degree. The average apical translation was 1.6 cm (range, 0.5~ 5.0 cm) representing a correction rate of 66,7% . Complication was noted in two cases with an incidence of 3.1% , one case had superficial infection and the other one had lower hook dislocation.There was no neurologic deficit and pseudoarthrodesis in this series. Conclusion. TSRH instrumentation is an effective and convenient three- dimensional correction system with a lower rate of complication, which can not only correct the coronal and rotational deformity, but maintain the sagittal alignment as well. 展开更多
关键词 SCOLIOSIS TSRH instrumentation treatment outcome
下载PDF
RESEARCH OF A NEW PORTABLE GC INSTRUMENTATION AND ITS APPLICATION IN BIOMEDICAL ENGINEERING 被引量:3
13
作者 Li Fucheng Li Zhiyi Pan Qi (College of Precision Instrumentation and photoelectron Engineering Tianjin University, Tianjin, 300072, China) 《Chinese Journal of Biomedical Engineering(English Edition)》 1997年第4期243-248,共6页
-A Portable gas chromatograPhy (GC) instrument is presented in this paper. In this GC instrument a new gaseous sampling device was used in place of conventional sampling valves.It has no quantitative tube or movable c... -A Portable gas chromatograPhy (GC) instrument is presented in this paper. In this GC instrument a new gaseous sampling device was used in place of conventional sampling valves.It has no quantitative tube or movable components in the sample Path. The sampling size si determined by time with a high precision,which is not sensitive to the sample temperature and pressure.Especially,the sample can not only inject into the column head,but also the carrier gas blow the column reversely and clean it.The portable GC instrument based on the sampling device can be used in enviromental and biomedical monitoring. 展开更多
关键词 GAS Chromatograpky Sampling DEVICE PORTABLE instrument.
下载PDF
A Systematic Approach for Instrumentation of a Mechatronic System 被引量:3
14
作者 Clarence W.DE SILVA 《Instrumentation》 2019年第1期116-136,共21页
This paper deals with instrumenting a mechatronic system,through the incorporation of suitable sensors,actuators,and other required hardware.Sensors(e.g.,semiconductor strain gauges,tachometers,RTD temperature sensors... This paper deals with instrumenting a mechatronic system,through the incorporation of suitable sensors,actuators,and other required hardware.Sensors(e.g.,semiconductor strain gauges,tachometers,RTD temperature sensors,cameras,piezoelectric accelerometers)are needed to measure(sense)unknown signals and parameters of a system and its environment.The information acquired in this manner is useful in operating or controlling the system,and also in process monitoring;experimental modeling(i.e.,model identification);product testing and qualification;product quality assessment;fault prediction,detection and diagnosis;warning generation;surveillance,and so on.Actuators(e.g.,stepper motors,solenoids,dc motors,hydraulic rams,pumps,heaters/coolers)are needed to"drive"a plant.Control actuators(e.g.,control valves)perform control actions,and in particular they drive control devices.Micro-electromechanical systems(MEMS)use microminiature sensors and actuators.MEMS sensors commonly use piezoelectric,capacitive,electromagnetic and piezoresistive principles.MEMS devices provide the benefits of small size and light weight(negligible loading errors),high speed(high bandwidth),and convenient mass-production(low cost).The process of instrumentation involves the identification of proper sensors,actuators,controllers,signal modification/interface hardware,and software with respect to their functions,operation,parameters,ratings,interaction with each other,so as to achieve the performance requirements of the overall system,and interfacing/integration/tuning of the selected devices into the system,for a given application.This paper presents the key steps of instrumenting a mechatronic system,in a somewhat general and systematic manner.Examples are described to illustrate several key procedures of instrumentation. 展开更多
关键词 instrumentation mechatronic systems sensors actuators SIGNAL MODIFICATION IMPEDANCE MATCHING system integration performance specification RATING parameters
下载PDF
Patient-specific instrumentation in total ankle arthroplasty 被引量:2
15
作者 Antonio Mazzotti Alberto Arceri +3 位作者 Simone Zielli Simone Bonelli Valentina Viglione Cesare Faldini 《World Journal of Orthopedics》 2022年第3期230-237,共8页
The recent increase in the adoption of total ankle arthroplasty(TAA)reflects the improvements in implant designs and surgical techniques,including the use of preoperative navigation system and patient-specific instrum... The recent increase in the adoption of total ankle arthroplasty(TAA)reflects the improvements in implant designs and surgical techniques,including the use of preoperative navigation system and patient-specific instrumentation(PSI),such as custom-made cutting guides.Cutting guides are customized with respect to each patient's anatomy based on preoperative ankle computed tomography scans,and they drive the saw intra-operatively to improve the accuracy of bone resection and implant positioning.Despite some promising results,the main queries in the literature are whether PSI improves the reliability of achieving neutral ankle alignment and more accurate implant sizing,whether it is actually superior over standard techniques,and whether it is cost effective.Moreover,the advantages of PSI in clinical outcomes are still theoretical because the current literature does not allow to confirm its superiority.The purpose of this review article is therefore to assess the current literature on PSI in TAA with regard to current implants with PSI,templating and preoperative planning strategies,alignment and sizing,clinical outcomes,cost analysis,and comparison with standard techniques. 展开更多
关键词 Total ankle arthroplasty Total ankle replacement Patient-specific instrumentation Ankle computer navigation system Preoperative navigation PROPHECY INFINITY INBONE II
下载PDF
Combination of Instrumented Nanoindentation and Scanning Probe Microscopy for Adequate Mechanical Surface Testing
16
作者 Enrico Tam Mikhail Petrzhik +1 位作者 Dmitry Shtansky Marie-Paule Delplancke-Ogletree 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2009年第1期63-68,共6页
The elastic indentation modulus and hardness of standard bulk materials and advanced thin films were determined by using the nanoindentation technique followed by the Oliver- Pharr post-treatment. After measurements w... The elastic indentation modulus and hardness of standard bulk materials and advanced thin films were determined by using the nanoindentation technique followed by the Oliver- Pharr post-treatment. After measurements with different loading/unloading schemes on chemically polished bulk titanium a substantial decrease of both modulus and hardness vs an increasing loading time was found. Then, hard nanostructured TiBN and TiCrBN thin films deposited by magnetron sputtering (using multiphase targets) on substrates of high roughness (sintered hard metal) and low roughness (silicon) were studied. Experimental modulus and hardness characterized by using two different nanoindenter tools were within the limits of standard deviation. However, a strong effect of roughness on the spread of the experimental values was observed and it was found that hardness and elastic indentation modulus obeyed a Gaussian distribution. The experimental data were discussed together with scanning probe microscopy (SPM) images of typical imprints taken after the nanoindentation tests and the local topographyls strong correlation with the results of nanoindentation was described. 展开更多
关键词 NANOINDENTATION Thin films COATINGS Scanning probe microscopy
下载PDF
The CCD instrument background of the SMILE SXI 被引量:2
17
作者 M.W.J.Hubbard O.Hetherington +6 位作者 D.J.Hall T.W.Buggey S.Parsons T.Arnold A.Holland C.Pagani S.Sembay 《Earth and Planetary Physics》 EI CSCD 2024年第1期15-24,共10页
The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrou... The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrounding radiation flux is high.The shutter door will close when passing below an altitude threshold to protect against trapped particles in the Earth’s Van Allen Belts.Therefore,two radiation environments can be approximated based on the shutter door position:open and closed.The instrument background for the CCDs(Charge-Coupled Devices)that form the focal plane array of the SXI were evaluated for the two environments.Due to the correlation of the space environment with the solar cycle,the solar minima and maxima,the background was also evaluated at these two extremes.The results demonstrated that the highest instrument background will occur during solar minima due to the main contributing source being Galactic Cosmic Rays(GCRs).It was also found that the open background was highest for solar minima and that the closed background was highest during solar maxima.This is due to the radiation shutter door acting as a scattering centre and the changes in the energy flux distribution of the GCRs between the two solar extremes. 展开更多
关键词 instrument background X-ray astronomy space radiation
下载PDF
Magnetically controlled growing instrumentation for early onset scoliosis: Caution needed when interpreting the literature
18
作者 Kenneth Aaron Shaw Justin M Hire +3 位作者 Scott Kim Dennis P Devito Michael L Schmitz Joshua S Murphy 《World Journal of Orthopedics》 2019年第11期394-403,共10页
BACKGROUND Magnetically controlled growing rods(MCGR) are a novel treatment option for early onset scoliosis(EOS). Although the complication profile with MCGR use has been reviewed, these reviews do not take into acco... BACKGROUND Magnetically controlled growing rods(MCGR) are a novel treatment option for early onset scoliosis(EOS). Although the complication profile with MCGR use has been reviewed, these reviews do not take into account important implants modifications, termed iterations, that were made due to early on postoperative complications is not well reported or understood.AIM To assess the effect of MCGR implant iterations on post-operative complications in EOS.METHODS A systematic review was performed to identify studies investigating MCGR specifically for the treatment of EOS, refined to those reporting the implant iteration, specifically the incorporation of the keeper plate to the implant design.Articles with mixed implant iteration usage were excluded. Complications following surgery were recorded as well as potential risk factors and compared between implant cohorts.RESULTS Although 20 articles were identified for inclusion, 5 included mixed implant iteration leaving a total of 271 patients identified through 15 clinical studies thatmet inclusion criteria. The average follow-up was 25.4-mo. Pre-keeper plate implants were utilized in 3 studies with a total of 49 patients. Overall, 115(42.4%)post-operative complications were identified, with 87% defined as major. The addition of the keeper plate significantly decreased the rate of post-operative complications per study(35.7% vs 80.6%, P = 0.036), and the rate of distraction failure(8.1% vs 40.8%, P = 0.02). Unplanned reoperation occurred in 69(26.7%)patients but was not different between implant iteration cohorts(25.5% without keeper plate vs 27.1% with keeper plate, P = 0.92).CONCLUSION MCGR for EOS has a cumulative complication rate of 42.4% but this is significantly reduced to 35.7% when reviewing only keeper-plate enabled implants. However, 25% of published articles included mixed implant iterations.Future studies should discern between implants iterations when reporting on the usage of MCGR for EOS. 展开更多
关键词 Complications Early ONSET SCOLIOSIS Magnetically controlled GROWING instrumentations KEEPER plate REOPERATION Systematic review
下载PDF
The cleaning efficiency of the root canal after different instrumentation technique and irrigation protocol:A SEM analysis 被引量:1
19
作者 Ferit Kocani Blerim Kamberi +2 位作者 Edmond Dragusha Shefqet Mrasori Fehim Haliti 《Open Journal of Stomatology》 2012年第2期69-76,共8页
Aim: The objective of this study was to evaluate the effectiveness of manual and ultrasonic instrumentation with varying irrigation protocols on removal of the smear layer from root canal walls. Methods: Forty extract... Aim: The objective of this study was to evaluate the effectiveness of manual and ultrasonic instrumentation with varying irrigation protocols on removal of the smear layer from root canal walls. Methods: Forty extracted single rooted human teeth stored in 0.5% saline were used. Periodontal soft tissues were removed followed by crown separation at the CEJ. All the teeth were randomly divided into two groups. Manually Instrumented Group 1 was irrigated with 5.25% NaOCl and 17% EDTA alternately, same as Ultrasonically Instrumented Group 2. The controls for both groups were irrigated with saline solution. Results: Ultrasonic instrumentation and the combined use of two different solutions (5.25% NaOCl and 17% EDTA) yielded better results on smear removal. Conclusions: Irrigation with 17% EDTA followed by 5.25% NaOCl was successful in complete removal of smear layer on cervical and middle thirds of the root canals. Ultrasonic instrumentation was slightly more successful on the apical one third of the root canals. 展开更多
关键词 Smear Layer instrumentation MANUAL ULTRASONIC CLEANING IRRIGATION
下载PDF
Radiological Evaluation of Spinal Instrumentation as Treatment for Adolescent Idiopathic Scoliosis, a Single Saudi Center 5-Year Experience
20
作者 Amir Monir Ali 《Open Journal of Radiology》 2018年第1期1-12,共12页
Aim of the Study: The aim of this work is to radiologically evaluate the postoperative outcomes of spinal instrumentation performed as a treatment for Adolescent Idiopathic Scoliosis (AIS) on 5-year follow up basis, a... Aim of the Study: The aim of this work is to radiologically evaluate the postoperative outcomes of spinal instrumentation performed as a treatment for Adolescent Idiopathic Scoliosis (AIS) on 5-year follow up basis, and to correlate with different clinical scenarios. Materials and Methods: One hundred (100) AIS consecutive patients treated with spinal instrumentation were included in this study. The study period was from 2012 to 2017. All patients had radiological evaluations including total spine x-rays, low dose CT scan using Orthopedic Metal Artifact Reduction (OMAR) software and MRI, after obtaining the informed consents and approval of the institution ethical board. Radiological evaluation included Cobb angle measurement assessed pre, postoperatively and at regular intervals within the 5-year period. Results: Of the 100 patients included, 24 were females and 76 were males. The average age at operation was 16.5 years. Sixty seven (67%) patients showed good correction and maintenance of the spinal curves where the mean Cobb angle was 68&deg;?preoperatively and 21&deg;postoperatively, representing a correction rate of 74%. Thirty three (33%) patients showed complications including postoperative infection (13), surgical revision (4), pseudarthrosis (3), neurological deficits (5), screw loosening (7) and complete hardware failure (1);in whom the preoperative mean Cobb angle was 56&deg;compared to the patients with no complications (p = 0.288). In males, there were postoperative complications in 27 out of 76 and in females 5 out of 24, (p = 0.027). The average duration of follow-up was 3.7 years for all cases. Conclusion: Five-year follow up of patients with AIS treated with spinal instrumentation demonstrates good improvement and maintenance of the corrected spinal curves in two thirds of patients, one third showed variable minor and major complications. Low dose CT scan with OMAR provided an effective modality for evaluation. 展开更多
关键词 AIS instrumentation RADIOLOGY Long-Term FOLLOW up
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部